3.16 CASING REMOVAL.<br />

To facilitate boiler maintenance the casing can be<br />

completely removed as follows: (Fig. 3-4 / 3-5):<br />

1 Unhook the decorative frame (a) from the<br />

relative lower retainers.<br />

2 Remove the decorative frame (a) from the casing<br />

(c).<br />

Installation drawings key:<br />

a<br />

1<br />

Unmistakable component identification<br />

Sequential identification of the operation to perform<br />

1<br />

3<br />

3 Loosen the 2 front screws (b) for fixing the<br />

casing.<br />

4 Loosen the 2 lower screws (d) for fixing the<br />

casing.<br />

5 Pull the case towards yourself (c).<br />

6 Push the case (c) upwards at the same time to<br />

release it from the upper hooks.<br />

b<br />

2<br />

a<br />

b<br />

3<br />

c<br />

Fig. 3-4<br />