hi.tech 34 35 The body of the tap is available in brass with a nickel-plating treatment with a chrome or gold finish; by 2013 a stainless steel body version will also be available. For versions without a compensator there is a stainless steel sleeve and a treated brass body, and with a plastic food-grade liner inside so that the drink is never in contact with the body of the nickel-plated brass tap. The sleeve will be available with a 5/8” thread or else ½” with a 7mm or 10mm hole inside (German version), and also with John Guest cartridges, the lengths are standard Celli: 35mm, 47mm or 65mm. All versions with a compensator will be compatible with the sleeve of the FC4 or Celtic range, those without a compensator will be compatible with the sleeve of the Celtic range. The design of this series of taps is protected by a patent application registration for a Celli S.p.A. model. fig. A Globus B satore che senza. Il corpo del rubinetto è disponibile in ottone con trattamento galvanico di nichelatura con finitura cromata o dorata; entro il 2013 sarà disponibile anche la versione con corpo in acciaio inox. Per le versioni senza compensatore è stato previsto il cannotto in acciaio inox ed il corpo rubinetto in ottone trattato, ma con al suo interno una camicia in materiale plastico alimentare in modo che la bevanda non sia mai in contatto con il corpo del rubinetto in ottone nichelato. Il canotto sarà disponibile con filetto da 5/8” oppure da ½” con foro interno da 7mm o da 10mm (versione Germania), ma anche con cartucce John Guest, le lunghezze sono standard Celli: 35mm, 47mm o 65mm. Tutte le versioni con compensatore saranno compatibili con il cannotto della serie FC4 o Celtic, quelle senza compensatore saranno compatibili col cannotto della serie Celtic. Il design di questa serie di rubinetti è protetto mediante una domanda di registrazione di un modello Celli S.p.A. globus taps rubinetti In the Lotus Plus and Alaska towers we have seen the possibility of keeping the beer lines cold right up to the tap. We believe this technology is extremely important for those who want to provide their customers with a quality product. As mentioned earlier, the benefits of the refrigerated taps are numerous: • When pulling the first beer no excessive head is formed • The temperature of the beer is always optimal • The proliferation of bacteria slows down For this reason we have developed a solution that would be suitable also for other towers. As we can see in the exploded drawing, it has to do with a brass heat exchanger that because it is welded to the recirculation pipe (water or glycol) it allows the cold to be transferred right up to the tap. The big news is that this system allows you to cool the tap without having any condensation on the body of the tower. As we can see in the photo below, the bushing fixed to the body of the tower by means of two front screws is isolated with a thermal cut. A patent application has been filed for this solution. The Cold Kit is available upon request on all the BRAHAuS, HAVANA, TuBE, AZuR, WAVE, ZENIT, MOON, ROMANTIC towers and also for the recent EOS T versions. Abbiamo visto nelle colonne Lotus Plus e Alaska, la possibilità di mantenere le linee birra refrigerate fino al rubinetto. Riteniamo questa tecnologia importantissima per chi è attento alla qualità del prodotto che offre ai propri clienti. Come già anticipato i vantaggi dei rubinetti refrigerati sono numerosi: • Al momento di spillare la prima birra erogata non si forma eccessiva schiuma • La temperatura della birra è sempre ottimale • Si rallenta la proliferazione batterica. Per questo motivo abbiamo sviluppato una soluzione che fosse adatta anche ad altre colonne. Come è possibile vedere nell’esploso, si tratta di uno scambiatore termico in ottone che essendo saldato con il tubo di ricircolo (acqua o glicole) permette il trasferimento di freddo fino al rubinetto. La grande novità è che questo sistema consente la refrigerazione del rubinetto evitando la condensazione del corpo della colonna. Come si può osservare nella foto sotto, infatti la boccola, fissata al corpo della colonna tramite due viti frontali, è isolata con taglio termico. Per questa soluzione è stata depositata una domanda di brevetto. Il Cold Kit è disponibile su richiesta su tutte le colonnine BRAHAuS, HAVANA, TuBE, AZuR, WAVE, ZENIT, MOON, ROMANTIC e anche per le recenti versioni EOS a T. NEw SOLUTIONS FOR REFRIGERATEd TAPS ON ST. STEEL ANd BRASS TOwERS NUOVE PROPOSTE PER REFRIGERAZIONE RUBINETTO PER COLONNE INOX E OTTONE coldkit FRONT VIEW ExCHANGER REAR VIEW ExCHANGER FRONTAL SCREWS FITTING CuTTING THERMAL IN PLASTIC MATERIAL CuTTING THERMAL IN PLASTIC MATERIAL FOAM PANEL FOR THERMAL INSuLATION BODY FOR FRONT FIxING IN ST.STEEL OR CROMED METAL SEAL, SLEEVE TAP BODY TOWER REAR VIEW OF HEAT ExCHANGER ASSEMBLY FOR COLD LIQuID RECIRCuLATION ROLLING HEAD TAP CONNECTION BRASS ExCHANGER COPPER PIPE FOR COLD LIQuID RECIRCuLATION AND THERMAL ExCHANGE PRODuCT LINE PIPE CuTTING THERMAL IN PLASTIC MATERIAL COLD ExCHANGER IN BRASS CuTTING THERMAL IN PLASTIC MATERIAL COPPER PIPE FOR RECIRCuLATION

hi.tech<br />

34 35<br />

The body of the tap is available in brass with a nickel-plating<br />

treatment with a chrome or gold finish; by 2013 a stainless<br />

steel body version will also be available.<br />

For versions without a compensator there is a stainless steel<br />

sleeve and a treated brass body, and with a plastic food-grade<br />

liner inside so that the drink is never in contact<br />

with the body of the nickel-plated brass tap.<br />

The sleeve will be available with a 5/8” thread or else ½”<br />

with a 7mm or 10mm hole inside (German version), and also<br />

with John Guest cartridges, the lengths are standard <strong>Celli</strong>:<br />

35mm, 47mm or 65mm.<br />

All versions with a compensator will be compatible with the<br />

sleeve of the FC4 or Celtic range, those without a compensator<br />

will be compatible with the sleeve of the Celtic range.<br />

The design of this series of taps is protected by a patent<br />

application registration for a <strong>Celli</strong> S.p.A. model.<br />

fig. A<br />

Globus B<br />

satore che senza.<br />

Il corpo del rubinetto è disponibile in ottone<br />

con trattamento galvanico di nichelatura con<br />

finitura cromata o dorata; entro il 2013 sarà<br />

disponibile anche la versione con corpo in acciaio<br />

inox.<br />

Per le versioni senza compensatore è stato<br />

previsto il cannotto in acciaio inox ed il corpo<br />

rubinetto in ottone trattato, ma con al suo interno<br />

una camicia in materiale plastico alimentare<br />

in modo che la bevanda non sia mai in contatto<br />

con il corpo del rubinetto in ottone nichelato.<br />

Il canotto sarà disponibile con filetto da 5/8”<br />

oppure da ½” con foro interno da 7mm o da<br />

10mm (versione Germania), ma anche con cartucce<br />

John Guest, le lunghezze sono standard<br />

<strong>Celli</strong>: 35mm, 47mm o 65mm.<br />

Tutte le versioni con compensatore saranno<br />

compatibili con il cannotto della serie FC4 o<br />

Celtic, quelle senza compensatore saranno<br />

compatibili col cannotto della serie Celtic.<br />

Il design di questa serie di rubinetti è protetto<br />

mediante una domanda di registrazione di un<br />

modello <strong>Celli</strong> S.p.A.<br />

globus<br />

taps rubinetti<br />

In the Lotus Plus and Alaska towers we have<br />

seen the possibility of keeping the beer lines cold<br />

right up to the tap. We believe this technology is extremely<br />

important for those who want to provide their<br />

customers with a quality product.<br />

As mentioned earlier, the benefits of the refrigerated<br />

taps are numerous:<br />

• When pulling the first beer no excessive head is formed<br />

• The temperature of the beer is always optimal<br />

• The proliferation of bacteria slows down<br />

For this reason we have developed a solution that<br />

would be suitable also for other towers.<br />

As we can see in the exploded drawing, it has to do<br />

with a brass heat exchanger that because it is welded<br />

to the recirculation pipe (water or glycol) it allows the<br />

cold to be transferred right up to the tap. The big news<br />

is that this system allows you to cool the tap without<br />

having any condensation on the body of the tower. As<br />

we can see in the photo below, the bushing fixed to<br />

the body of the tower by means of two front screws is<br />

isolated with a thermal cut.<br />

A patent application has been filed for this solution.<br />

The Cold Kit is available upon request on all the<br />

BRAHAuS, HAVANA, TuBE, AZuR, WAVE, ZENIT, MOON,<br />

ROMANTIC towers and also for the recent EOS T versions.<br />

Abbiamo visto nelle colonne Lotus Plus e Alaska,<br />

la possibilità di mantenere le linee birra refrigerate<br />

fino al rubinetto. Riteniamo questa tecnologia importantissima<br />

per chi è attento alla qualità del prodotto<br />

che offre ai propri clienti.<br />

Come già anticipato i vantaggi dei rubinetti refrigerati<br />

sono numerosi:<br />

• Al momento di spillare la prima birra erogata non si<br />

forma eccessiva schiuma<br />

• La temperatura della birra è sempre ottimale<br />

• Si rallenta la proliferazione batterica.<br />

Per questo motivo abbiamo sviluppato una soluzione<br />

che fosse adatta anche ad altre colonne.<br />

Come è possibile vedere nell’esploso, si tratta di uno<br />

scambiatore termico in ottone che essendo saldato<br />

con il tubo di ricircolo (acqua o glicole) permette il trasferimento<br />

di freddo fino al rubinetto. La grande novità<br />

è che questo sistema consente la refrigerazione del<br />

rubinetto evitando la condensazione del corpo della<br />

colonna. Come si può osservare nella foto sotto, infatti<br />

la boccola, fissata al corpo della colonna tramite due<br />

viti frontali, è isolata con taglio termico.<br />

Per questa soluzione è stata depositata una domanda<br />

di brevetto.<br />

Il Cold Kit è disponibile su richiesta su tutte le colonnine<br />

BRAHAuS, HAVANA, TuBE, AZuR, WAVE, ZENIT, MOON,<br />

ROMANTIC e anche per le recenti versioni EOS a T.<br />

NEw SOLUTIONS FOR REFRIGERATEd<br />

TAPS ON ST. STEEL ANd BRASS TOwERS<br />

NUOVE PROPOSTE<br />

PER REFRIGERAZIONE RUBINETTO<br />

PER COLONNE INOX E OTTONE<br />

coldkit<br />

FRONT VIEW ExCHANGER REAR VIEW ExCHANGER<br />

FRONTAL<br />

SCREWS<br />

FITTING<br />

CuTTING THERMAL<br />

IN PLASTIC MATERIAL<br />

CuTTING THERMAL IN<br />

PLASTIC MATERIAL<br />

FOAM PANEL FOR<br />

THERMAL INSuLATION<br />

BODY FOR FRONT FIxING IN<br />

ST.STEEL OR CROMED METAL SEAL, SLEEVE TAP<br />

BODY TOWER<br />

REAR VIEW OF<br />

HEAT ExCHANGER<br />

ASSEMBLY<br />

FOR COLD LIQuID<br />

RECIRCuLATION<br />

ROLLING HEAD TAP CONNECTION<br />

BRASS ExCHANGER<br />

COPPER PIPE FOR COLD LIQuID<br />

RECIRCuLATION AND THERMAL<br />

ExCHANGE<br />

PRODuCT LINE PIPE<br />

CuTTING THERMAL IN PLASTIC MATERIAL<br />

COLD ExCHANGER IN BRASS<br />

CuTTING THERMAL IN PLASTIC MATERIAL<br />

COPPER PIPE FOR RECIRCuLATION