STUDIO MICROMOTOR<br />
3.3.2 - INSTRUCTIONS FOR USE<br />
3.3.2.1 - Startup<br />
With the appliance powered down for safety, fit the required tool into the<br />
handpiece.<br />
The appliance can now be powered up by means of main power switch<br />
(1). Start the handpiece motor by means of footpe<strong>da</strong>l (2) on the bench-top<br />
version (pe<strong>da</strong>l control (9) on the floor version).<br />
The direction of tool rotation can be inverted by means of reverse selector<br />
(6); when reverse mode is selected amber LED (10) will illuminate.<br />
Tool speed can be adjusted by means of slider control (7) on the benchtop<br />
model, or pe<strong>da</strong>l control (9) on the floor model.<br />
3.3.2.2 - Normal stopping and emergency stop procedures<br />
The motor can be stopped as follows:<br />
- by releasing footpe<strong>da</strong>l (2) (or control (9) on the floor model);<br />
- by setting main power switch (1) to OFF;<br />
- by unplugging the power cable from the electrical socket outlet.<br />
3.3.2.3 - Warnings<br />
In relation to the material being machined, use appropriate personal<br />
protection devices (facemask, gloves, safety glasses, etc.) and, if<br />
necessary, a suitable exhauster system.<br />
3.4 - MAINTENANCE<br />
All work on electrical components accessible only after removing the<br />
casing must be performed exclusively by properly authorized and trained<br />
personnel. Certain parts of the unit carrying <strong>da</strong>ngerously high voltages are<br />
accessible when the casing is removed, representing a source of <strong>da</strong>nger<br />
during maintenance work if performed when the appliance is powered up.<br />
3.4.1 - CLEANING<br />
The appliance does not require maintenance with the exception of<br />
cleaning; before cleaning the appliance disconnect it from the power<br />
supply.<br />
Special attention is required when cleaning the <strong>micromotor</strong> and cable (not<br />
autoclavable) and stand; these parts can be cleaned with denatured<br />
alcohol or proprietary sterilizing products. Do not sterilize the <strong>micromotor</strong><br />
using liquids that conduct electricity.<br />
<strong>Carlo</strong> de <strong>Giorgi</strong> GB - 9