Technische Daten<br />

<strong>HDS</strong> 9/<strong>16</strong>-4<br />

<strong>ST</strong> <strong>Gas</strong>,<br />

1.251-103<br />

<strong>HDS</strong> 9/<strong>16</strong>-4<br />

<strong>ST</strong> <strong>Gas</strong><br />

<strong>LPG</strong>, 1.251-<br />

104<br />

<strong>HDS</strong> 9/<strong>16</strong>-4<br />

<strong>ST</strong> <strong>Gas</strong><br />

<strong>LPG</strong>, 1.251-<br />

107<br />

<strong>HDS</strong> 9/<strong>16</strong>-4<br />

<strong>ST</strong> <strong>Gas</strong><br />

<strong>LPG</strong>, 1.251-<br />

107 +<br />

2.641-915<br />

<strong>HDS</strong> <strong>12</strong>/<strong>14</strong>-<br />

4 <strong>ST</strong> <strong>Gas</strong>,<br />

1.251-105<br />

<strong>HDS</strong> <strong>12</strong>/<strong>14</strong>-<br />

4 <strong>ST</strong> <strong>Gas</strong><br />

<strong>LPG</strong>, 1.251-<br />

106<br />

Leistungsdaten<br />

Arbeitsdruck Wasser (mit Standarddü- MPa (bar)<br />

se)<br />

<strong>16</strong> (<strong>16</strong>0) <strong>16</strong> (<strong>16</strong>0) <strong>16</strong> (<strong>16</strong>0) <strong>16</strong> (<strong>16</strong>0) <strong>14</strong> (<strong>14</strong>0) <strong>14</strong> (<strong>14</strong>0)<br />

Max. Arbeitsdruck Dampfbetrieb (mit<br />

Dampfdüse)<br />

MPa (bar) 3,2 (32) 3,2 (32) 3,2 (32) 3,2 (32) 3,2 (32) 3,2 (32)<br />

Teile-Nr. Dampfdüse 4.766-023 4.766-023 4.766-023 4.766-023 4.766-023 4.766-023<br />

Max. Betriebsüberdruck (Sicherheitsventil)<br />

MPa (bar) 17,5 (175) 17,5 (175) 17,5 (175) 17,5 (175) 17,5 (175) 17,5 (175)<br />

Fördermenge Wasser (stufenlos re- l/h (l/min) 500-960 500-960 500-960 500-960 600-<strong>12</strong>00 600-<strong>12</strong>00<br />

gelbar)<br />

(8,3-<strong>16</strong>) (8,3-<strong>16</strong>) (8,3-<strong>16</strong>) (8,3-<strong>16</strong>) (10-20) (10-20)<br />

Reinigungsmittelansaugung (stufenlos l/h (l/min)<br />

regelbar)<br />

Wasseranschluss<br />

0-50 (0-0,8) 0-50 (0-0,8) 0-50 (0-0,8) 0-50 (0-0,8) 0-60 (0-1) 0-60 (0-1)<br />

Zulaufmenge (min.) l/h (l/min) 1100 (18,3) 1100 (18,3) 1100 (18,3) 1100 (18,3) 1300 (21,7) 1300 (21,7)<br />

Zulaufdruck (min.) MPa (bar) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1) 0,1 (1)<br />

Zulaufdruck (max.)<br />

Elektrischer Anschluss<br />

MPa (bar) 0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6) 0,6 (6)<br />

Stromart 3N~ 3N~ 3N~ 3N~ 3N~ 3N~<br />

Frequenz Hz 50 50 60 60 50 50<br />

Spannung V 380-420 380-420 230 440 380-420 380-420<br />

Anschlussleistung kW 6,4 6,4 6,0 6,0 7,5 7,5<br />

Elektrische Absicherung (träge) A <strong>16</strong> <strong>16</strong> <strong>16</strong> <strong>16</strong> 20 20<br />

Maximal zulässige Netzimpedanz Ohm (0,381+j (0,381+j (0,381+j (0,381+j (0,381+j (0,381+j<br />

0,238) 0,238) 0,238) 0,238) 0,238) 0,238)<br />

Elektrozuleitung mm2 Temperatur<br />

5 x 2,5 5 x 2,5 5 x 2,5 5 x 2,5 5 x 2,5 5 x 2,5<br />

Zulauftemperatur (max.) °C 30 30 30 30 30 30<br />

Max. Arbeitstemperatur Heißwasser °C 98 98 98 98 98 98<br />

Max. Temperatur Sicherheitsthermostat<br />

°C 110 110 110 110 110 110<br />

Temperaturerhöhung bei max. Wasserdurchsatz<br />

°C 60-65 60-65 60-65 60-65 60-65 60-65<br />

Heizleistung brutto kW 75 75 75 75 95 95<br />

Kaminzug<br />

<strong>Gas</strong>-Anschlusswerte<br />

kPa 0,01-0,04 0,01-0,04 0,01-0,04 0,01-0,04 0,01-0,04 0,01-0,04<br />

Erdgas E (G 20) m3 /h 7,2 -- -- -- 9,8 --<br />

Erdgas LL (G 25) m3 /h 8,2 -- -- -- 11,4 --<br />

Nennanschlussdruck (Erdgas) kPa 1,8-3 -- -- -- 1,8-3 --<br />

Propan kg/h -- 5,7 5,7 5,7 -- 7,2<br />

Nennanschlussdruck (Propan)<br />

Umweltdaten<br />

kPa -- 5-6 5-6 5-6 -- 5-6<br />

Normnutzungsgrad % 97 97 97 97 97 97<br />

Normemissionsfaktor NOX (Erdgas G<br />

25)<br />

mg/kWh < 40 -- -- -- < 40 --<br />

Normemissionsfaktor CO (Erdgas G<br />

25)<br />

Werte zur Schornsteinbemessung<br />

mg/kWh < 40 -- -- -- < 40 --<br />

Überdruckeignung (min.) kPa 0,05 0,05 0,05 0,05 0,05 0,05<br />

Zugbedarf kPa 0 0 0 0 0 0<br />

Abgasmassenstrom - Volllast kg/h 130 130 130 130 <strong>16</strong>6 <strong>16</strong>6<br />

CO2 (Erdgas) % 9,5 -- -- -- 9,5 --<br />

CO2 (Propan) % -- <strong>12</strong> <strong>12</strong> <strong>12</strong> -- <strong>12</strong><br />

Abgastemperatur max./min. °C 190/150 190/150 190/150 190/150 170/130 170/130<br />

Verbrennungsluft/Luftzufuhr<br />

Kondensatablass<br />

Max. Länge: 10 m mit zwei 90° Bögen (Mindestdurchmesser 100 mm). Nach örtlichen Vorschriften<br />

aus dem Aufstellungsraum oder Frischluft von außen.<br />

Kondensatablass (max.) l/h 4 (über Si- 4 (über Si- 4 (über Si- 4 (über Si- 4 (über Si- 4 (über Siphon<br />

in Kaphon in Kaphon in Kaphon in Kaphon in Kaphon in Kanalisation)nalisation)nalisation)nalisation)nalisation)nalisation)<br />

Anschluss DN 40 (HTR) 40 (HTR) 40 (HTR) 40 (HTR) 40 (HTR) 40 (HTR)<br />