– The insulation of the pipes must be resistant to temperatures until 155 °C. Install the detergent tank Figure 17 - Pos. 20 The tanks are to be installed in such a way that the lower level mirror of the detergent should not be more than 1.5 m under the machine floor and the upper level mirror should not be located above the machine floor. Exhaust system – Each appliance must be connected to a separate chimney. – The exhaust system must be designed according to the local rules and regulations after consulting the concerned chimney expert. Water supply Figure 17 - B and item 19 The water inlet is to be connected to the main water supply using an appropriate water hose. – The water supply must have a minimum output of 1300 l/h at minimum 0.1 MPa. – The water temperature must lie below 30 °C. Electrical connection Warning The highest allowed net impedance at the electrical connection point (refer to technical data) is not to be exceeded. Note Operating procedures create short term power sinkings. During unfavorable net conditions other devices might be disturbed. – For connection values, see technical data and type plate. – The electrical connections must be done by an electrician according to IEC 60364-1. – Current-carrying parts, cables and appliances in the working area must be installed in a defectless state and must be protected against water sprays. To avoid accidents due to electrical faults we recommend the use of sockets with a line-side current-limiting circuit breaker (max. 30 mA nominal tripping current). Firmly installed electrical connection Establish the electrical connection. A main switch that can be locked (figure 17 - item 6) is to be installed at a safe and easily accessible place to switch off the stationary high pressure cleaner. The contact opening of the main switch must be minimum 3 mm. Electrical connection with plug/ socket Install Cekon plug on the connection cable of the appliance. Insert Cekon plug into the socket. To switch off the stationary high pressure cleaner, the Cekon plug must be easily accessible so that it can be removed from the mains. The plug and coupling of the extension cable used must be watertight. Always fully unroll electrical cables from the cable drum. 38 English Initial startup The device is set in the factory as a natural gas device to gas type G 20 and as LPG device to G 31. While switching over natural gas devices to G 25 or other natural gases (see type plate) or the LPG device to G 30 or other LPGs (see type plate), the natural gas exhaust values in case of natural gas devices and the LPG exhaust values in case of LPG devices are to be set according to the service information. The enclosed empty type plate will be filled up with values of the new gas type that is set and will be fixed on the right side of the device in the address field. At the same time, the plate with the G 20 (natural gas device) details or G 31 (LPG device) details fitted at the factory must be removed. Check gas connection. Warning Risk of damage to the appliance on account of over-heating. Connect the siphon to the boiler floor and fill water. Fill the boiler via the chimney opening with 4 litres of water. Before using for the first time, cut off the tip of the lid of the oil tank on the water pump. Measures to be taken before start-up Figure 17 - Pos. 14 Connect the high pressure hose with the hand-spray gun and the spray pipe and connect it to the high pressure outlet of the appliance or the high pressure pipe network. Figure 13 Fasten the nozzle mouth-piece (b) with the union nut (a) on the spray pipe (d). Please ensure that the sealing ring (c) is cleanly positioned in the nut. b c a a b c d Anti-calcification measures Figure 14 Remove spring (c) from the lid support (b) of the softener tank (a). Fill the tank with Kaercher softener liquid RM 110 (Order no. 2.780-001). Danger Risk of electrical voltage! Setting may only be done by an electrician. Determining the hardness of tap water: – through the public water supply works, – using a hardness tester (order no. 6.768-004) Remove the appliance cover.
Open the switch box at the operating panel. Figure 15 Set the speed potentiometer (a) according to the water hardness. You can refer to the correct setting in the table. Example: For a water hardness of 15 °dH, set 6 on the value scale of the speed potentiometer. This results in a pause of 31 seconds, i.e. the solenoid valve will open briefly every 31 seconds. Water hardness (°dH) 5 10 15 20 25 Scale on the speed potentiometer 8 7 6 5 4,5 Pause (in seconds) 50 40 31 22 16 Adjusting the operations stand-by time The operations stand-by time is set on the larger plate on the left side-wall of the electrical cabinet. S2 8 7 6 5 4 3 2 1 min. max. Figure 16 The operations stand-by time is set in the factory to a minimum time of 2 minutes and can be increased to a maximum time of 8 minutes. a English 39
- Page 1: Register and win! www.kaercher.com!
- Page 4 and 5: - BImSchV: Verordnung zur Durchfüh
- Page 6 and 7: Gefahr Verletzungsgefahr! Gerät, Z
- Page 8 and 9: Verschmutzung - Reinigungsmittel er
- Page 10 and 11: Minimale Wassersäule, Siphon Zulas
- Page 12 and 13: Mit dem zuständigen Kärcher-Verka
- Page 14 and 15: Störung Mögliche Ursache Behebung
- Page 16 and 17: ! - Die Heizeinrichtung des Geräte
- Page 18 and 19: - Die Isolation der Rohrleitung mus
- Page 20 and 21: Bild 17 20 Deutsch Installationsmat
- Page 22 and 23: Hiermit erklären wir, dass die nac
- Page 24 and 25: The work station is located at the
- Page 26 and 27: Danger Risk of injury! Device, tube
- Page 28 and 29: Dirt Nozzle Spray an- Part no. Pres
- Page 30 and 31: Connectiing piece DN 40 (HTR) 40 (H
- Page 32 and 33: You can enter into a maintenance co
- Page 34 and 35: Fault Possible cause Remedy of whom
- Page 36 and 37: ! - The heating appliance of the ma
- Page 40 and 41: Figure 17 40 English Installation m
- Page 42 and 43: We hereby declare that the machine
- Page 44 and 45: - Seul des monteurs du SAV Kärcher
- Page 46 and 47: Danger Risque de blessure ! L'appar
- Page 48 and 49: Salissure Buse Angle de projection
- Page 50 and 51: Raccordement DN 40 (HTR) 40 (HTR) 4
- Page 52 and 53: Un contrat de maintenance pour l'ap
- Page 54 and 55: Panne Eventuelle cause Remède Par
- Page 56 and 57: ! - Le dispositif de chauffage de l
- Page 58 and 59: - L'isolation du tuyautage doit êt
- Page 60 and 61: Figure 17 60 Français Matériel d'
- Page 62 and 63: Nous certifions par la présente qu
- Page 64 and 65: - DIN 13384-1: calcoli delle dimens
- Page 66 and 67: Pericolo Rischio di lesioni! L' app
- Page 68 and 69: Sporco Ugello Angolo di spruzzo HDS
- Page 70 and 71: Scarico condensa (max.) l/h 4 (medi
- Page 72 and 73: E' possibile stipulare un contratto
- Page 74 and 75: Guasto Possibile causa Rimedio Adde
- Page 76 and 77: ! - Il dispositivo di riscaldamento
- Page 78 and 79: Montare il contenitore del detergen
- Page 80 and 81: Fig. 17 80 Italiano Materiale per l
- Page 82 and 83: Con la presente si dichiara che la
- Page 84 and 85: - DVGW werkbladen: G260, G600, G670
- Page 86 and 87: Gevaar Verwondingsgevaar! Apparaat,
Open the switch box at the operating panel.<br />
Figure 15<br />
Set the speed potentiometer (a) according to the water hardness.<br />
You can refer to the correct setting in the table.<br />
Example:<br />
For a water hardness of 15 °dH, set 6 on the value scale of the<br />
speed potentiometer. This results in a pause of 31 seconds, i.e.<br />
the solenoid valve will open briefly every 31 seconds.<br />
Water hardness (°dH) 5 10 15 20 25<br />
Scale on the speed potentiometer<br />
8 7 6 5 4,5<br />
Pause (in seconds) 50 40 31 22 <strong>16</strong><br />
Adjusting the operations stand-by time<br />
The operations stand-by time is set on the larger plate on the left<br />
side-wall of the electrical cabinet.<br />
S2<br />
8 7 6 5 4 3 2 1<br />
min. max.<br />
Figure <strong>16</strong><br />
The operations stand-by time is set in the factory to a minimum<br />
time of 2 minutes and can be increased to a maximum time of 8<br />
minutes.<br />