13.07.2015 Views

LSB german_french_english 771076129 - Water Solutions

LSB german_french_english 771076129 - Water Solutions

LSB german_french_english 771076129 - Water Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation, Operation and Maintenance InstructionModel <strong>LSB</strong>11. Motor Operating InstructionsThe following instructions must be followedexactly, to guarantee the safety at theinstallation, at the operation and at themaintenance of the motor. All persons shouldbe directed to the present manual which areperforming these tasks. The neglect of theinstructions can cause the loss of theguarantee.Electrical connectionsMake sure that the rated voltage corresponds tothe supply voltage.Ground the pump before making any otherconnection.We recommend that a high sensitivitydifferential switch (30 mA) be installed as extraprotection against lethal electric shocks in theevent of faulty grounding.Connect the pump to the mains using a multiple-poleswitch or other device ensuring multiple-poledisconnection (interruption of all the supply wires) fromthe mains, with a contact separation of at least 3 mm.Remove the terminal board cover by first removing thescrews.Carry out the connections as indicated on the back ofthe terminal board cover, and as shown in fig. 3 - 4.The single-phase version has a built-in overloadprotection; the three-phase version must be equippedby the user with a magneto-thermal switch ormagnetic starter with overload and undervoltageprotection, a thermal relay and fuses installedupstream.The overload relay must be set to the motor currentrating. The thermal relay may be set to a current valueslightly lower than the full load value when the electricpump is definitely underloaded, but the thermaloverload protection must not be set to current valueshigher than the full load values.Fault finding chartPROBLEM PROBABLE CAUSE POSSIBLEREMEDIES1. The pump doesn’tstart2. Overloadprotection trips:– accidentalyA) No electricalpowerB) Blown fuses:B1 Becauseinadeguate (blowingcurrent too low)B2 Because themotor or the supplycable are damagedC) Overloadprotection previouslytrippedA) Momentary loss ofa phase– systematically C) Incorrect settingof the motor switchD) The pump’sdelivery is higher thanthe rated oneE) Dense and viscousliquidA) Supply electricalpowerB1 Replace fuseswith adequate onesB2 Repair the motoror replace the cableC)Reset theprotection (if it tripsagain see problem 2)C) Set to ratedcurrentD) Close the deliveryvalve until thecapacity returns tothe rated valueE) Determine theactual powerrequirements andreplace the motoraccordinglyChecking the rotation direction of electric pumpswith three-phase motors.The direction of rotation may be checked before thepump is filled with the liquid to be pumped, providedit is run for very short starts only.The pump must not be run until it is filled withliquid.Continuous dry running will damage themechanical seal beyond repair.If the direction of rotation is not anti-clockwise whenfacing the pump from the suction side interchange twosupply leads.<strong>LSB</strong> 100-<strong>english</strong> page 88 Revision 02Artikel Nr. <strong>771076129</strong> Ausgabe 01/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!