FLENDER gear units - Siemens

FLENDER gear units - Siemens FLENDER gear units - Siemens

13.07.2015 Views

Wärmegrenzleistungen Thermal Capacities Capacités thermiquesBauart B4.. Type B4.. Type B4..Größen 5 - 22 Sizes 5 - 22 Tailles 5 - 22 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 28.6 42.4 60 90.6 121 162 183 250 35190 P GA 27.9 41 58.6 87.9 118 155 167 175 188 240 256 339 355100 P GA 26.6 30.6 38.8 45.3 55.6 60.4 84.4 101 112 130 146 160 164 180 227 246 319 344112 P GA 25.6 29.9 37.4 44 53.5 59 80.4 97.6 107 126 139 151 157 169 216 232 309 322125 P GA 24.5 28.6 35.7 41.6 51 56 77 93.2 102 119 132 144 149 161 205 221 291 3133140 P GA 23.4 27.5 33.9 40.1 48.1 53.9 72.8 88.8 97.6 114 128 137 144 154 198 211 281 294160 P GA 21.5 26.3 30.9 38.2 44 51.3 66.4 85.1 92.4 110 121 132 136 148 187 203 265 284180 P GA 21.1 25.1 30.1 36.4 42.9 48.7 64.6 80.6 87.2 103 114 124 128 139 175 191 248 269200 P GA 20.4 23.1 29.9 33.2 42 44.6 63.2 73.6 85.2 98.5 112 117 126 132 174 179 240 251224 P GA 19 22.7 27.8 32.4 39.3 43.4 59.4 71.8 79.9 93.2 105 116 117 130 163 179 224 243250 P GA 18.5 21.8 26.9 32.1 37.9 42.5 57.5 70.1 77.3 90.6 102 108 114 122 158 168 217 227280 P GA 17.6 20.4 25.2 30 36.1 39.8 55 65.8 73 85.2 95 104 107 117 148 161 207 220315 P GA 16.5 19.8 23.6 28.8 33.9 38.4 51.3 63.7 69.6 82.4 89.7 98.5 101 110 140 153 193 210355 P GA 19 27.1 36.6 60.8 77.8 92.4 104 144 196400 P GA 17.7 25.4 34.5 56.7 74.1 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 30.5 45.1 63.5 94.9 125 165 183 248 33490 P GA 29.9 43.7 62.2 92.3 123 159 170 176 189 240 255 327 336100 P GA 28.5 32.7 41.4 48.2 59.1 64.1 88.9 106 117 135 150 163 167 182 228 247 311 330112 P GA 27.5 32 39.9 46.9 56.9 62.7 84.9 102 112 132 144 155 161 173 219 235 306 314125 P GA 26.3 30.6 38.2 44.4 54.4 59.7 81.5 98.4 108 125 138 149 154 166 210 226 291 309140 P GA 25.1 29.5 36.3 42.9 51.4 57.5 77.3 94.1 103 120 134 143 149 159 204 217 284 294160 P GA 23.1 28.2 33.2 41 47 54.9 70.7 90.4 97.8 116 127 138 142 155 194 210 271 288180 P GA 22.7 27 32.4 39 46 52.2 69 85.9 92.8 110 120 131 135 146 183 200 256 276200 P GA 21.9 24.9 32.1 35.7 45.1 47.8 67.7 78.7 91 105 119 125 134 140 183 189 251 261224 P GA 20.4 24.4 30 34.9 42.3 46.7 63.8 77 85.6 99.8 112 123 125 138 174 190 237 256250 P GA 20 23.5 29 34.6 40.8 45.8 61.9 75.4 83.1 97.4 109 116 122 131 169 180 232 243280 P GA 19 22 27.2 32.3 39 43 59.3 71 78.8 92 102 113 115 127 160 174 224 237315 P GA 17.8 21.4 25.5 31.1 36.6 41.5 55.4 68.7 75.2 89 96.9 106 109 119 152 165 209 227355 P GA 20.5 29.2 39.6 65.6 84 99.7 113 155 211400 P GA 19.1 27.4 37.3 61.2 80P GA (kW) Getriebe ohne Zusatzkühlung **)**) Werte gelten für:Einschaltdauer: 100 %Aufstellung in großer HalleHöhenlage bis 1000 mP GA (kW) Gear units without auxiliarycooling **)**) Values refer to:Operating cycle: 100 %Installation in a large hallAltitude up to 1000 mP GA (kW) Réducteurs sans refroidissementsupplémentaire **)**) Les valeurs sont valables pour:Durée d’utilisation: 100 %Implantation dans un grand hallAltitude jusqu’à 1000 m52 ·

Wärmegrenzleistungen Thermal Capacities Capacités thermiquesBauart B4.. Type B4.. Type B4..Größen 5 - 22 Sizes 5 - 22 Tailles 5 - 22 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 31.7 46.9 66.1 98.6 130 171 189 256 34390 P GA 31.1 45.5 64.7 95.9 128 164 175 183 195 248 264 337 345100 P GA 29.6 34 43.1 50.2 61.5 66.7 92.4 110 121 140 156 169 173 188 236 255 321 339112 P GA 28.6 33.3 41.5 48.8 59.2 65.3 88.3 106 116 137 149 161 167 179 227 243 315 323125 P GA 27.4 31.8 39.7 46.2 56.6 62.1 84.8 102 112 130 143 155 159 172 218 234 300 318140 P GA 26.1 30.7 37.8 44.6 53.5 59.9 80.4 97.8 107 125 139 148 155 165 211 225 294 304160 P GA 24.1 29.4 34.5 42.7 49 57.2 73.6 94.1 101 121 132 143 147 160 202 218 281 298180 P GA 23.6 28.1 33.7 40.7 47.9 54.3 71.8 89.3 96.5 114 125 136 140 152 190 208 266 2863200 P GA 22.8 25.9 33.5 37.2 47 49.8 70.5 81.9 94.7 109 124 130 139 146 191 196 260 271224 P GA 21.3 25.4 31.2 36.4 44 48.6 66.5 80.2 89.1 104 117 128 130 144 181 198 246 266250 P GA 20.8 24.5 30.2 36 42.5 47.8 64.5 78.6 86.6 101 114 120 127 136 176 187 241 252280 P GA 19.8 22.9 28.4 33.7 40.6 44.8 61.8 74 82.1 95.9 106 117 120 132 167 182 233 247315 P GA 18.6 22.3 26.6 32.4 38.2 43.2 57.8 71.6 78.4 92.7 100 110 113 124 158 172 217 236355 P GA 21.3 30.4 41.2 68.4 87.6 103 117 162 220400 P GA 19.9 28.6 38.9 63.8 83.4 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 33 48.6 68.1 100 130 168 184 245 31290 P GA 32.3 47.2 66.8 97.9 129 163 173 178 190 239 253 311 311100 P GA 30.9 35.4 44.8 52 63.6 68.8 94.7 112 123 142 155 168 170 185 230 247 301 312112 P GA 29.8 34.7 43.2 50.6 61.4 67.5 90.7 109 118 139 150 161 165 177 223 238 300 302125 P GA 28.5 33.2 41.4 48 58.8 64.3 87.3 105 114 133 144 155 160 171 216 231 290 303140 P GA 27.3 32 39.4 46.5 55.6 62.2 83.1 100 109 128 141 150 156 166 212 224 288 294160 P GA 25.2 30.7 36.1 44.5 51 59.5 76.2 97.2 104 124 135 146 150 162 204 220 278 292180 P GA 24.7 29.4 35.2 42.5 50 56.6 74.6 92.6 99.8 118 129 140 143 155 194 211 266 285200 P GA 23.9 27.1 35 38.9 49.1 52 73.4 85.2 98.3 113 128 134 143 150 196 201 264 274224 P GA 22.3 26.7 32.7 38.1 46.1 50.9 69.5 83.7 92.9 108 121 133 135 149 187 205 253 273250 P GA 21.8 25.7 31.7 37.8 44.6 50.1 67.6 82.3 90.6 106 119 126 133 142 184 195 251 262280 P GA 20.9 24.1 29.8 35.4 42.7 47.1 65 77.7 86.3 100 112 123 126 139 175 191 245 260315 P GA 19.5 23.5 27.9 34.1 40.1 45.4 60.7 75.2 82.3 97.4 106 116 119 131 166 180 228 248355 P GA 22.4 32 43.3 71.8 92 109 123 170 231400 P GA 21 30 40.8 67 87.6P GA (kW) Getriebe ohne Zusatzkühlung **)**) Werte gelten für:Einschaltdauer: 100 %Aufstellung in großer HalleHöhenlage bis 1000 m · P GA (kW) Gear units without auxiliarycooling **)**) Values refer to:Operating cycle: 100 %Installation in a large hallAltitude up to 1000 mP GA (kW) Réducteurs sans refroidissementsupplémentaire **)**) Les valeurs sont valables pour:Durée d’utilisation: 100 %Implantation dans un grand hallAltitude jusqu’à 1000 m53

Wärmegrenzleistungen Thermal Capacities Capacités thermiquesBauart B4.. Type B4.. Type B4..Größen 5 - 22 Sizes 5 - 22 Tailles 5 - 22 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 28.6 42.4 60 90.6 121 162 183 250 35190 P GA 27.9 41 58.6 87.9 118 155 167 175 188 240 256 339 355100 P GA 26.6 30.6 38.8 45.3 55.6 60.4 84.4 101 112 130 146 160 164 180 227 246 319 344112 P GA 25.6 29.9 37.4 44 53.5 59 80.4 97.6 107 126 139 151 157 169 216 232 309 322125 P GA 24.5 28.6 35.7 41.6 51 56 77 93.2 102 119 132 144 149 161 205 221 291 3133140 P GA 23.4 27.5 33.9 40.1 48.1 53.9 72.8 88.8 97.6 114 128 137 144 154 198 211 281 294160 P GA 21.5 26.3 30.9 38.2 44 51.3 66.4 85.1 92.4 110 121 132 136 148 187 203 265 284180 P GA 21.1 25.1 30.1 36.4 42.9 48.7 64.6 80.6 87.2 103 114 124 128 139 175 191 248 269200 P GA 20.4 23.1 29.9 33.2 42 44.6 63.2 73.6 85.2 98.5 112 117 126 132 174 179 240 251224 P GA 19 22.7 27.8 32.4 39.3 43.4 59.4 71.8 79.9 93.2 105 116 117 130 163 179 224 243250 P GA 18.5 21.8 26.9 32.1 37.9 42.5 57.5 70.1 77.3 90.6 102 108 114 122 158 168 217 227280 P GA 17.6 20.4 25.2 30 36.1 39.8 55 65.8 73 85.2 95 104 107 117 148 161 207 220315 P GA 16.5 19.8 23.6 28.8 33.9 38.4 51.3 63.7 69.6 82.4 89.7 98.5 101 110 140 153 193 210355 P GA 19 27.1 36.6 60.8 77.8 92.4 104 144 196400 P GA 17.7 25.4 34.5 56.7 74.1 Wärmegrenzleistungen P G (kW) / Thermal capacities P G (kW) / Capacités thermiques P G (kW)Getriebegrößen / Gear unit sizes / Tailles réducteursi N5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2280 P GA 30.5 45.1 63.5 94.9 125 165 183 248 33490 P GA 29.9 43.7 62.2 92.3 123 159 170 176 189 240 255 327 336100 P GA 28.5 32.7 41.4 48.2 59.1 64.1 88.9 106 117 135 150 163 167 182 228 247 311 330112 P GA 27.5 32 39.9 46.9 56.9 62.7 84.9 102 112 132 144 155 161 173 219 235 306 314125 P GA 26.3 30.6 38.2 44.4 54.4 59.7 81.5 98.4 108 125 138 149 154 166 210 226 291 309140 P GA 25.1 29.5 36.3 42.9 51.4 57.5 77.3 94.1 103 120 134 143 149 159 204 217 284 294160 P GA 23.1 28.2 33.2 41 47 54.9 70.7 90.4 97.8 116 127 138 142 155 194 210 271 288180 P GA 22.7 27 32.4 39 46 52.2 69 85.9 92.8 110 120 131 135 146 183 200 256 276200 P GA 21.9 24.9 32.1 35.7 45.1 47.8 67.7 78.7 91 105 119 125 134 140 183 189 251 261224 P GA 20.4 24.4 30 34.9 42.3 46.7 63.8 77 85.6 99.8 112 123 125 138 174 190 237 256250 P GA 20 23.5 29 34.6 40.8 45.8 61.9 75.4 83.1 97.4 109 116 122 131 169 180 232 243280 P GA 19 22 27.2 32.3 39 43 59.3 71 78.8 92 102 113 115 127 160 174 224 237315 P GA 17.8 21.4 25.5 31.1 36.6 41.5 55.4 68.7 75.2 89 96.9 106 109 119 152 165 209 227355 P GA 20.5 29.2 39.6 65.6 84 99.7 113 155 211400 P GA 19.1 27.4 37.3 61.2 80P GA (kW) Getriebe ohne Zusatzkühlung **)**) Werte gelten für:Einschaltdauer: 100 %Aufstellung in großer HalleHöhenlage bis 1000 mP GA (kW) Gear <strong>units</strong> without auxiliarycooling **)**) Values refer to:Operating cycle: 100 %Installation in a large hallAltitude up to 1000 mP GA (kW) Réducteurs sans refroidissementsupplémentaire **)**) Les valeurs sont valables pour:Durée d’utilisation: 100 %Implantation dans un grand hallAltitude jusqu’à 1000 m52 ·

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!