12.07.2015 Views

Finish 270 Finish 250 - WAGNER-Group

Finish 270 Finish 250 - WAGNER-Group

Finish 270 Finish 250 - WAGNER-Group

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Finish</strong> <strong>270</strong> / <strong>250</strong>GBCleaning the unitThe container must be earthed in case ofcoating materials which contain solvents.Wipe down unit externally with a cloth which has been immersedin a suitable cleaning agent.8.2 SuCTION fIlTERCaution! Do not pump or spray in containerwith small opening (bunghole)!See safty regulations.Clean filters always ensure maximum volume,constant spray pressure and problem-freefunctioning of the unit.5. Fill up hopper with suitable cleaning agent.6. Open relief valvevalve position (circulation)7. Pump suitable cleaning agent in the circuit for several minutes.with cleaning ring (TopClean) step 8 up to 128. Switch reverser knob into a horizontal position.The cleaning agent will flow around the circumference ofthe inner hopper wall and will clean it in some minutes,depending of the fouling9. Switch reverser knob into the upright position.Cleaning agent is flowing directly into the hopperDo not switch the reverser knob at the cleaningring into the horizontal position whenthe pump is load with coating material. Thedevider holes can be plugged.Than the cleaning work of cleaning ring isreduced, and it will take more time up to thecleaning ring has cleaned themself.10. Close relief valve,valve position (spraying)11. Pump the remaining cleaning agent from the hopper,high-pressure hose and the spray gun into an open container12. Open relief valvevalve position (circulation)13. Switch off unit8.1 ClEANING ThE uNIT fROm ThE OuTSIDEFirst unplug the power plug from the outlet.Danger of short-circuits caused by wateringression! Never spray down the unit withhigh-pressure or high-pressure steam cleaners.Do not put the high-pressure hose into solvents.Use only a wet cloth to wipe down theoutside of the hose.suction tubeUnit with suction system1. Unscrew the filter (Item 1) from the suction tube.2. Clean or replace the filter.Carry out cleaning with a hard brush and a correspondingcleaning agent.8.3 hIGh-pRESSuRE fIlTER1. Open relief valvevalve position (circulation) - Switch the unit off.2. Open the high-pressure filter and clean the filter insert. Todo so:3. Unscrew the filter housing (1) by hand.4. Remove the filter insert (2) and pull out the bearing spring(3).5. Clean all the parts with the corresponding cleaning agent.If compressed air is available – blow through the filter insertand bearing spring.6. When mounting the filter ensure that the bearing ring (4)in the filter insert is positioned correctly and check the O-ring at the filter housing for damage.7. Screw on the filter housing by hand until it stops (a highertightening force only impedes later dismantling).215l hopperUnit with hopper1. Release screws with a screwdriver (Item 2).2. Lift and remove filter disk with a screwdriver3. Clean or replace the filter disk.Carry out cleaning with a hard brush and a correspondingcleaning agent.43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!