12.07.2015 Views

Contra Corriente - FIBERPOOL

Contra Corriente - FIBERPOOL

Contra Corriente - FIBERPOOL

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CROSS-CURRENT EQUIPMENT HANDBOOK13- ELECTRICAL CONNECTIONSWARNINGIn general terms, the electrical installation will fully complywith the regulations and complementary Technicalprovisions applicable and will be performed by anauthorised installer.The supply will have neutral and earth wires.The mains voltage must correspond to that shown on thenameplate rating for the equipment.The cross section of the conductors used must be sufficientto withstand the load drawn by the unit withoutdeterioration.All metal parts of the unit which are not supposed to beunder current, but might do so accidentally and which areaccessible to people, must be electrically connected toearth.The electrical characteristics of the protection devices anttheir regulation must be in accordance with thoseapplicable to the motor to be protected and the envisagedconditions of operation. All the instructions given by themanufacturer must be followed (see motor nameplate).In the case of units with three-phase motors, theinterconnection bridges between the motor windings mustbe fitted in the right places.Entry and exit of conductors from the terminal box must bevia glands guaranteeing the absence of damp and dirt inthe box , which must also be fitted with a watertight seal.Conductors will have suitable terminals for connection tothe bushings.The hydro pneumatic panel must be installed in a dry place,above water level and at a distance not greater than 8m.from the start / stop switch on the front of the unit.The transparent pipe (nº2 fig.2) is to be connected to themicro switch located on the upper right-hand part of thepanel. It is very important to ensure that the transparentpipe has no bends in it. The hydro pneumatic panelconsists of:-1 thermal / magnetic circuit breaker.-1 contact switch.-1 pneumatic cut-out switch-1 operating fuse.All these items are to be installed in a water-tight plasticcabinet with degree of protection IP55.Note: For more information about installation, conservationand maintenance, etc. see the instructions manual for theuse and maintenance of the BC type pump included withthe unit.PANEL CIRCUIT DIAGRAMW V U L3 L2 L1 NWVUL3L2L1NW V UL3L2L1Nalimentaciónalimentationfeedingmotor 220v. IIIpotenciometropotentiomètrepotentiometeralimentaciónalimentationfeedingred /réseausupply system220v. IIIalimentaciónalimentationfeedingmotor 380v. IIIpotenciometropotentiomètrepotentiometeralimentaciónalimentationfeedingred /réseausupply system380v. IIIalimentaciónalimentationfeedingmotor 220v. IIpotenciometropotentiomètrepotentiometeralimentaciónalimentationfeedingred /réseausupply system220v. II20

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!