12.07.2015 Views

Say yes to solar power! - SAT Solar

Say yes to solar power! - SAT Solar

Say yes to solar power! - SAT Solar

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Mechanical dataCellConnectionTandem cell of amorphous (-Si) andmicrocrystalline (c-Si) silicon2 sub-modules in parallelDimensions 1,129 × 934 × 46 mm (1.05 m 2 )WeightConnection typeBypass diodes 1Electrical data18 kgCable with plug connec<strong>to</strong>r (MC-3)Initial valuesLimit valuesS<strong>to</strong>rage air humidity (relative) up <strong>to</strong> 90 %Operating temperature (cell) – 40 <strong>to</strong> + 90 °CS<strong>to</strong>rage temperature – 40 <strong>to</strong> + 90 °CMaximum system voltage 600 V DCMaximum mechanical load 2,400 N/m 2Over-current protection 4 ANominal valuesNA-953 (WQ) NA-901 (WQ) NA-851 (WQ) NA-953 (WQ) NA-901 (WQ) NA-851 (WQ)Maximum <strong>power</strong> P max 111.8 W p 105.9 W p 100 W p 95 W p 90 W p 85 W pThe reference image on the front page shows a 4.5 kWp system of Sharp.Open-circuit voltage V oc 66.3 66.6 65.0 65.3 65.2 63.8 VShort-circuit current I sc 2.37 2.20 2.20 2.30 2.11 2.11 AVoltage at point of maximum <strong>power</strong> V mpp 52.7 53.5 52.0 48.0 49.3 49.0 VCurrent at point of maximum <strong>power</strong> I mpp 2.12 1.98 1.92 1.98 1.83 1.74 AModule efficiency m 9.0 8.5 8.1 %NOCT 44 44 44 °CTemperature coefficient – open-circuit voltage V oc – 0.30 – 0.30 – 0.30 – 0.30 – 0.30 – 0.30 % / °CTemperature coefficient – short-circuit current l sc +0.070 +0.070 +0.070 +0.070 +0.070 +0.070 % / °CTemperature coefficient – <strong>power</strong> P max – 0.24 – 0.24 – 0.24 – 0.24 – 0.24 – 0.24 % / °CThe electrical data applies under standard test conditions (STCs): irradiation 1,000 W/m 2 with light spectrum AM 1.5 and a cell temperature of 25 °C. The rated electrical characteristics are subject <strong>to</strong> a manufacturing<strong>to</strong>lerance of ± 10%. NOCT conditions: irradiation of 800 W/m 2 , ambient temperature of 20 °C and wind speed of 1 m/sec.Characteristic curves NA-953 (WQ)ApplicationsCharacteristic curves: current / <strong>power</strong> vs. voltage(cell temperature: 25 °C)Current (A)2.52.01.51.00.50.01,000 (W/m 2 )800 (W/m 2 )600 (W/m 2 )400 (W/m 2 )200 (W/m 2 )10 20 30 40 50 60 70Voltage (V)Current vs. voltagePower vs. voltage100908070605040302010Power (W)Open-circuit voltage Isc, Voc, Pmax (%)Characteristic curves: open-circuit voltage /short-circuit current vs. irradiation(cell temperature: 25 °C)1201101009080706050403020100V ocI scP maxIrradiance (W/m 2 ),■ On-grid PV systems■ Off-grid PV systems■ On-roof PV systems■ Ground-mounted PV systemsPlease read our detailed installationmanual carefully before installing thepho<strong>to</strong>voltaic modules. The instructionsin the installation manual must alwaysbe observed (e.g. max. of 7 modulesin series, minus pole must be grounded,protection with blocking diodes/fuses).A genera<strong>to</strong>r box with approvedblocking diodes is available fromyour Sharp dealer.Exterior dimensionsNote93446238 ± 201005061,129Junction boxFrame <strong>Solar</strong> cellJunction boxPlug connec<strong>to</strong>r38 + − 151055ScrewSide sealFrameCross-section A-A’GlassPlastic<strong>Solar</strong> cellBack coverConnection cable55900 ± 30900 ± 30100Cross-section B-B’Technical data is subject <strong>to</strong> change without priornotice. Before using Sharp products, please requestthe latest data sheets from Sharp. Sharp acceptsno responsibility for damage <strong>to</strong> devices which havebeen equipped with Sharp products on the basis ofunverified information.The specifications may deviate slightly and are notguaranteed. Installation and operating instructionsare <strong>to</strong> be found in the corresponding handbooks, orcan be downloaded from www.sharp.eu.This module should not be directly connected <strong>to</strong>a load.Sharp Energy Solution Europea division of Sharp Electronics (Europe) GmbHSonninstrasse 3, 20097 Hamburg, GermanyTel: + 49 (0) 40 / 23 76 - 0 · Fax: + 49 (0) 40 / 23 76 - 21 93www.sharp.euLocal responsibility:Distribution byAustria<strong>Solar</strong>Info.at@sharp.euBenelux<strong>Solar</strong>Info.seb@sharp.euCentral & Eastern Europe<strong>Solar</strong>Info.scee@sharp.euDenmark<strong>Solar</strong>Info.dk@sharp.euFrance<strong>Solar</strong>Info.fr@sharp.euGermany<strong>Solar</strong>Info.de@sharp.eu <strong>SAT</strong> SOLAR AGLohstampfestr.11CH-8274 TägerwilenSwitzerlandTel: +41 716693750Fax: +41 716693751info@sat-<strong>solar</strong>.chwww.sat-<strong>solar</strong>.chScandinavia<strong>Solar</strong>Info.sen@sharp.euSpain & Portugal<strong>Solar</strong>Info.es@sharp.euSwitzerland<strong>Solar</strong>Info.ch@sharp.euUnited Kingdom<strong>Solar</strong>Info.uk@sharp.eu<strong>Solar</strong>NA_105_E0210

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!