<strong>FIBERPOOL</strong> INTERNACIONALThe control panel should be installed by an authorisedtechnician. Power supply must be protected by adifferential and a magnetothermic.IP 54TEMPERATURE: from 5º to 70ºCAcceptable Voltage Fluctuation: +/- 10%Feed cables and cables going to the electric pump need to beof a 1,5mm2 section and with an insulation material of 1000V.Connections to the terminals must be made with pre-insulatedconnectors.The motorized valves must be earthed. To change a fuse,MAKE SURE THAT ELECTRICITY SUPPLY IS CUT OFF,unscrew the top screws, remove the cover, and pull the fusebox from the top, which should leave you with the cover in yourhand and the fuse inside. Take it out, change it and do exactlythe same operation in reverse. All work in the control panel,except changing the fuse, should be carried out by anauthorized technician, otherwise all rights and guaranteeswould become void.CONNECTIONS220V AC 50/60 Hz.............Programme connectionELEC……………………….Switch free of powerPRES……………………….Pressure switch connectionBOMBA……………………..Pumps switchAL VAL……………………...Feed valve supplyVALV1………………………Connection valve 1VALV2………………………Connection valve 2VALV3………………………Connection valve 3VALV4………………………Connection valve 4VALV5…………………….. .Connection valve 5O……………………………..Valve openCOM…………………………Valves commonC…………………………… ..Valve closedLAVADO…………………….Washing time programme, filter 1ENJUAGUE…………………Rinse time programmeCAMBIO……………………..Valve positioning time programmeWARNING: If the equipment is used for any other purposethan these specified by the manufacturer, the equipmentmay be subject to a loss of warranty.Every 6 months, check for tightness all the connections. Theinstallation must comply with norms of II category. The supplycables to the equipment must be installed in a way so thatsafety is maintained and no damage is caused to theinsulation. This programmer is specially designed for groups of5 motorized filtration valves.An anchoring device such as a packing gland must be used inorder to prevent twisting and traction in the cable.Ponent, 2-4-6 P.I. Sant Pere Molanta08799 Olèrdola, BARCELONAMOD: P.P.A.P. 220V II7380 v III 50/60HZ CorrienteCorriente equipo: 0.3 APotencia max.: 3hp (220V II) y 5.5hp(380V III)Nº de serie: FBP-00001CHARACTERISTICS- Programmer feed 220V II- Valve feed, as required- Valves switch power, 4A- Protection fuse for the plate 5 x 20, class F 100mA- Possibility of programming the valves with different timing- Pumps stopped while the valves are functioning- If there is a tension failure or if tension is cut off, when thetension will be restored, the valves will be in a filtering positionFUNCTIONINGThe washing cycles can be started by :- External contact of the pressure switch- Manual switch- Weekly time setting8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!