EDK<strong>82</strong>MV222<br />

.ùlS<br />

Ä.ùlSä<br />

L<br />

Montageanleitung<br />

Mounting Instructions<br />

Instructions <strong>de</strong> montage<br />

<strong>82</strong>00 <strong>motec</strong><br />

0,55 <strong>kW</strong> ... 2,2 <strong>kW</strong>


2006 L<strong>en</strong>ze Drive Systems GmbH<br />

8.0 03/2006 TD03<br />

Les<strong>en</strong> Sie zuerst die Montageanleitung, bevor Sie mit <strong>de</strong>n<br />

Arbeit<strong>en</strong> beginn<strong>en</strong>!<br />

Beacht<strong>en</strong> Sie die <strong>en</strong>thalt<strong>en</strong><strong>en</strong> Sicherheitshinweise.<br />

Die Betriebsanleitung mit ausführlicher Information zum<br />

Frequ<strong>en</strong>zumrichter <strong>82</strong>00 <strong>motec</strong> könn<strong>en</strong> Sie bei Ihrem<br />

L<strong>en</strong>ze−Vertriebspartner bestell<strong>en</strong>.<br />

Read the Mounting Instructions before you start working!<br />

Please observe all safety information giv<strong>en</strong>.<br />

Detailed Operating Instructions for the <strong>82</strong>00 <strong>motec</strong> can be<br />

or<strong>de</strong>red directly <strong>fr</strong>om L<strong>en</strong>ze or L<strong>en</strong>ze repres<strong>en</strong>tatives.<br />

Lire att<strong>en</strong>tivem<strong>en</strong>t les instructions <strong>de</strong> montage avant toute<br />

opération !<br />

Respecter les consignes <strong>de</strong> sécurité.<br />

Les instructions <strong>de</strong> mise <strong>en</strong> service compr<strong>en</strong>ant une <strong>de</strong>scription<br />

complète du convertisseur <strong>de</strong> <strong>fr</strong>équ<strong>en</strong>ce <strong>82</strong>00 <strong>motec</strong> peuv<strong>en</strong>t<br />

être commandées auprès <strong>de</strong> votre ag<strong>en</strong>ce L<strong>en</strong>ze.


W2 U 2 V 2<br />

U1 V 1 W 1<br />

PE<br />

W2 U 2 V2<br />

U1 V1 W 1<br />

PE<br />

<strong>82</strong>00mot020<br />

<strong>82</strong>00mot021<br />

5<br />

5<br />

5<br />

<strong>82</strong>00mot136<br />

<strong>82</strong>00mot137<br />

<strong>82</strong>00mot165<br />

19<br />

21<br />

21<br />

<strong>82</strong>00mot139<br />

<strong>82</strong>00mot140<br />

<strong>82</strong>00mot141<br />

24<br />

29<br />

<strong>82</strong>00mot142<br />

<strong>82</strong>00mot143<br />

L1/L2/L3/PE<br />

31<br />

<strong>82</strong>00mot144<br />

<strong>82</strong>00 <strong>motec</strong><br />

33<br />

K14 K12 K11 X1<br />

<strong>82</strong>00mot145


Diese Dokum<strong>en</strong>tation ist gültig für Antriebsregler <strong>82</strong>00 <strong>motec</strong> ab <strong>de</strong>m Gerätestand<br />

E<strong>82</strong>MV xxx _ 4 B001 XX 1x 3x<br />

Typ<br />

551 = 550 W<br />

751 = 750 W<br />

152 = 1.5 <strong>kW</strong><br />

222 = <strong>2.2</strong> <strong>kW</strong><br />

4 = 400 V Hardwarestand Softwarestand<br />

l<br />

<strong>82</strong>00mot166<br />

Hinweis!<br />

Aktuelle Dokum<strong>en</strong>tation<strong>en</strong> und Software−Updates zu L<strong>en</strong>ze<br />

Produkt<strong>en</strong> fin<strong>de</strong>n Sie im Internet jeweils im Bereich "Downloads"<br />

unter<br />

http://www.L<strong>en</strong>ze.com


PS<br />

<br />

<br />

V<br />

%sh<br />

Lo<br />

PE<br />

U1 V 1 W1<br />

V2 U2 2 W<br />

Inbetriebnahme <strong>82</strong>00 <strong>motec</strong> ohne Funktionsmodul<br />

Der <strong>82</strong>00 <strong>motec</strong> ist nur funktionsfähig mit aufgesteckter<br />

FIF−Ab<strong>de</strong>ckkappe ! (Auslieferungszustand).<br />

– Ohne die FIF−Ab<strong>de</strong>ckkappe ist <strong>de</strong>r <strong>82</strong>00 <strong>motec</strong><br />

gesperrt (Keypad: ).<br />

Da <strong>de</strong>r <strong>82</strong>00 <strong>motec</strong> ohne Funktionsmodul keine<br />

Steuerklemm<strong>en</strong> hat, kann das Start<strong>en</strong> und Stopp<strong>en</strong><br />

währ<strong>en</strong>d <strong>de</strong>s Betriebs auch über Netzschalt<strong>en</strong> erfolg<strong>en</strong>.<br />

Die Funktion speichert bei Netzschalt<strong>en</strong> o<strong>de</strong>r<br />

Betriebsunterbrechung<strong>en</strong> <strong>de</strong>n Sollwert zum Zeitpunkt<br />

<strong>de</strong>r Unterbrechung. Nach Netzwie<strong>de</strong>rkehr läuft <strong>de</strong>r<br />

Antrieb selbsttätig wie<strong>de</strong>r an!<br />

W<strong>en</strong>n <strong>de</strong>r Antrieb in Schritt nicht anläuft (<br />

erlischt nicht), drück<strong>en</strong>, um <strong>de</strong>n <strong>82</strong>00 <strong>motec</strong><br />

<strong>fr</strong>eizugeb<strong>en</strong>.<br />

A<br />

<strong>82</strong>00mot146<br />

E<strong>82</strong>ZWLxxx<br />

L1/L2/L3/PE<br />

rpm<br />

°C<br />

8888888 8<br />

m A<br />

<br />

<br />

<br />

<br />

<br />

E<strong>82</strong>ZBB<br />

88888<br />

<br />

Hi Hz<br />

1 2<br />

<br />

<br />

0140<br />

3<br />

5000<br />

Hz<br />

AIF<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

0....+50 Hz<br />

<strong>82</strong>00mot170<br />

0....- 50 Hz<br />

Schritt Bemerkung siehe Kapitel<br />

<br />

<br />

<br />

Handterminal (<strong>en</strong>thält<br />

Keypad) mit <strong>motec</strong> verbin<strong>de</strong>n.<br />

Stecker <strong>de</strong>r Verbindungsleitung<br />

in die<br />

AIF−Schnittstelle am <strong>motec</strong><br />

steck<strong>en</strong>.<br />

Netzspannung<br />

zuschalt<strong>en</strong>.<br />

Selbstanlauf möglich!<br />

Handterminal und Verbindungsleitung sind nicht im Lieferumfang<br />

<strong>en</strong>thalt<strong>en</strong>.<br />

Der Antriebsregler ist nach ca. 1 Sekun<strong>de</strong> betriebsbereit.<br />

Keypad: <br />

Sollwert über die Funktion<br />

aktivier<strong>en</strong> <br />

vorgeb<strong>en</strong>.<br />

Rechtslauf erlischt. Der Antrieb läuft jetzt.<br />

Linkslauf Display zeigt Ausgangs<strong>fr</strong>equ<strong>en</strong>z.<br />

Störung<strong>en</strong> währ<strong>en</strong>d <strong>de</strong>r Inbetriebnahme o<strong>de</strong>r währ<strong>en</strong>d <strong>de</strong>s Betriebs?<br />

7


i<br />

Inhalt<br />

Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

L<strong>en</strong>ze−Antriebsregler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

Drehstrommaschin<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9<br />

Restgefahr<strong>en</strong>, Gestaltung <strong>de</strong>r Sicherheitshinweise . . . . . . . . . . . . . . . . . 13<br />

Technische Dat<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />

Norm<strong>en</strong> und Einsatzbedingung<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />

Allgemeine elektrische Dat<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

Abmessung<strong>en</strong>, Mechanische Ausführung . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

<strong>motec</strong> mit Motor o<strong>de</strong>r Getriebemotor . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

EMV−gerechte Verdrahtung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

Wandmontage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br />

Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br />

Vorbereitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

Motoranschluß . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24<br />

EMV−gerechte Verdrahtung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

Motormontage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

Vorbereitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br />

Motoranschluß . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

EMV−gerechte Verdrahtung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

Elektrische Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

Netzanschluß / Bremswi<strong>de</strong>rstand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31<br />

Anschluß Relaisausgang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

Montage Funktionsmodul (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

<strong>motec</strong> zusamm<strong>en</strong>bau<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

Inbetriebnahme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

Vor <strong>de</strong>m erst<strong>en</strong> Einschalt<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br />

Wahl <strong>de</strong>r richtig<strong>en</strong> Betriebsart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

Parametrierung mit <strong>de</strong>m Handterminal E<strong>82</strong>ZBB . . . . . . . . . . . . . . . . . . . 40<br />

Lineare U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

Vector−Regelung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme . . . . . . . . . . . . . . . . . . . . 48<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

Fehlverhalt<strong>en</strong> <strong>de</strong>s Antriebs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59<br />

Störungsmeldung<strong>en</strong>. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />

4<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

L<strong>en</strong>ze−Antriebsregler<br />

1<br />

Allgemeine Sicherheits− und Anw<strong>en</strong>dungshinweise für<br />

L<strong>en</strong>ze−Antriebsregler<br />

(gemäß Nie<strong>de</strong>rspannungsrichtlinie 73/23/EWG)<br />

Allgemein−1−<br />

L<strong>en</strong>ze−Antriebsregler (Frequ<strong>en</strong>zumrichter, Servo−Umrichter, Stromrichter)<br />

könn<strong>en</strong> währ<strong>en</strong>d <strong>de</strong>s Betriebs − ihrer Schutzart <strong>en</strong>tsprech<strong>en</strong>d − spannungsführ<strong>en</strong><strong>de</strong>,<br />

auch bewegliche o<strong>de</strong>r rotier<strong>en</strong><strong>de</strong> Teile hab<strong>en</strong>. Oberfläch<strong>en</strong> könn<strong>en</strong><br />

heiß sein.<br />

Bei unzulässigem Entfern<strong>en</strong> <strong>de</strong>r erfor<strong>de</strong>rlich<strong>en</strong> Ab<strong>de</strong>ckung, bei unsachgemäßem<br />

Einsatz, bei falscher Installation o<strong>de</strong>r Bedi<strong>en</strong>ung besteht die Gefahr<br />

von schwer<strong>en</strong> Person<strong>en</strong>− o<strong>de</strong>r Sachschä<strong>de</strong>n.<br />

Weitere Information<strong>en</strong> <strong>en</strong>tnehm<strong>en</strong> Sie <strong>de</strong>r Dokum<strong>en</strong>tation.<br />

Alle Arbeit<strong>en</strong> zum Transport, zur Installation, zur Inbetriebnahme und zur Instandhaltung<br />

darf nur qualifiziertes Fachpersonal ausführ<strong>en</strong> (IEC 364 bzw.<br />

CENELEC HD 384 o<strong>de</strong>r DIN VDE 0100 und IEC−Report 664 o<strong>de</strong>r DIN VDE<br />

0110 und nationale Unfallverhütungsvorschrift<strong>en</strong> beacht<strong>en</strong>).<br />

Qualifiziertes Fachpersonal im Sinne dieser grundsätzlich<strong>en</strong> Sicherheitshinweise<br />

sind Person<strong>en</strong>, die mit Aufstellung, Montage, Inbetriebsetzung und<br />

Betrieb <strong>de</strong>s Produkts vertraut sind und die über die ihrer Tätigkeit <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>n<br />

Qualifikation<strong>en</strong> verfüg<strong>en</strong>.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 5


1 Sicherheitshinweise<br />

L<strong>en</strong>ze−Antriebsregler<br />

Bestimmungsgemäße Verw<strong>en</strong>dung<br />

Antriebsregler sind Kompon<strong>en</strong>t<strong>en</strong>, die zum Einbau in elektrische Anlag<strong>en</strong><br />

o<strong>de</strong>r Maschin<strong>en</strong> bestimmt sind. Sie sind keine Haushaltsgeräte, son<strong>de</strong>rn als<br />

Kompon<strong>en</strong>t<strong>en</strong> ausschließlich für die Verw<strong>en</strong>dung zur gewerblich<strong>en</strong> Nutzung<br />

bzw. professionell<strong>en</strong> Nutzung im Sinne <strong>de</strong>r EN 61000−3−2 bestimmt. Die Dokum<strong>en</strong>tation<br />

<strong>en</strong>thält Hinweise zur Einhaltung <strong>de</strong>r Gr<strong>en</strong>zwerte nach<br />

EN 61000−3−2.<br />

Bei Einbau <strong>de</strong>r Antriebsregler in Maschin<strong>en</strong> ist die Inbetriebnahme (d. h. die<br />

Aufnahme <strong>de</strong>s bestimmungsgemäß<strong>en</strong> Betriebs) solange untersagt, bis festgestellt<br />

wur<strong>de</strong>, daß die Maschine <strong>de</strong>n Bestimmung<strong>en</strong> <strong>de</strong>r EG−Richtlinie<br />

98/37/EG (Maschin<strong>en</strong>richtlinie) <strong>en</strong>tspricht; EN 60204 beacht<strong>en</strong>.<br />

Die Inbetriebnahme (d. h. die Aufnahme <strong>de</strong>s bestimmungsgemäß<strong>en</strong> Betriebs)<br />

ist nur bei Einhaltung <strong>de</strong>r EMV−Richtlinie (89/336/EWG) erlaubt.<br />

Die Antriebsregler erfüll<strong>en</strong> die Anfor<strong>de</strong>rung<strong>en</strong> <strong>de</strong>r Nie<strong>de</strong>rspannungsrichtlinie<br />

73/23/EWG. Die harmonisiert<strong>en</strong> Norm<strong>en</strong> <strong>de</strong>r Reihe EN 50178/DIN VDE<br />

0160 wer<strong>de</strong>n für die Antriebsregler angew<strong>en</strong><strong>de</strong>t.<br />

Die technisch<strong>en</strong> Dat<strong>en</strong> und die Angab<strong>en</strong> zu Anschlußbedingung<strong>en</strong> <strong>en</strong>tnehm<strong>en</strong><br />

Sie <strong>de</strong>m Leistungsschild und <strong>de</strong>r Dokum<strong>en</strong>tation. Halt<strong>en</strong> Sie sie unbedingt<br />

ein.<br />

Warnung: Die Antriebsregler sind Produkte mit eingeschränkter Erhältlichkeit<br />

nach EN 61800−3. Diese Produkte könn<strong>en</strong> im Wohnbereich Funkstörung<strong>en</strong><br />

verursach<strong>en</strong>. In diesem Fall kann es für <strong>de</strong>n Betreiber erfor<strong>de</strong>rlich sein,<br />

<strong>en</strong>tsprech<strong>en</strong><strong>de</strong> Maßnahm<strong>en</strong> durchzuführ<strong>en</strong>.<br />

Transport, Einlagerung<br />

Beacht<strong>en</strong> Sie die Hinweise für Transport, Lagerung und sachgemäße Handhabung.<br />

Halt<strong>en</strong> Sie die klimatisch<strong>en</strong> Bedingung<strong>en</strong> nach EN 50178 ein.<br />

Aufstellung<br />

Sie müss<strong>en</strong> die Antriebsregler nach <strong>de</strong>n Vorschrift<strong>en</strong> <strong>de</strong>r zugehörig<strong>en</strong> Dokum<strong>en</strong>tation<br />

aufstell<strong>en</strong> und kühl<strong>en</strong>.<br />

Sorg<strong>en</strong> Sie für sorgfältige Handhabung und vermei<strong>de</strong>n Sie mechanische<br />

Überlastung. Verbieg<strong>en</strong> Sie bei Transport und Handhabung we<strong>de</strong>r Bauelem<strong>en</strong>te<br />

noch än<strong>de</strong>rn Sie Isolationsabstän<strong>de</strong>. Berühr<strong>en</strong> Sie keine elektronisch<strong>en</strong><br />

Bauelem<strong>en</strong>te und Kontakte.<br />

Antriebsregler <strong>en</strong>thalt<strong>en</strong> elektrostatisch gefähr<strong>de</strong>te Bauelem<strong>en</strong>te, die Sie<br />

durch unsachgemäße Handhabung leicht beschädig<strong>en</strong> könn<strong>en</strong>. Beschädig<strong>en</strong><br />

o<strong>de</strong>r zerstör<strong>en</strong> Sie keine elektrisch<strong>en</strong> Kompon<strong>en</strong>t<strong>en</strong>, da Sie dadurch<br />

Ihre Gesundheit gefähr<strong>de</strong>n könn<strong>en</strong>!<br />

6<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

L<strong>en</strong>ze−Antriebsregler<br />

Elektrischer Anschluß<br />

Beacht<strong>en</strong> Sie bei Arbeit<strong>en</strong> an unter Spannung steh<strong>en</strong><strong>de</strong>n Antriebsreglern<br />

die gelt<strong>en</strong><strong>de</strong>n national<strong>en</strong> Unfallverhütungsvorschrift<strong>en</strong> (z. B. VBG 4).<br />

Führ<strong>en</strong> Sie die elektrische Installation nach <strong>de</strong>n einschlägig<strong>en</strong> Vorschrift<strong>en</strong><br />

durch (z. B. Leitungsquerschnitte, Absicherung<strong>en</strong>, Schutzleiteranbindung).<br />

Zusätzliche Hinweise <strong>en</strong>thält die Dokum<strong>en</strong>tation.<br />

Die Dokum<strong>en</strong>tation <strong>en</strong>thält Hinweise für die EMV−gerechte Installation<br />

(Schirmung, Erdung, Anordnung von Filtern und Verlegung <strong>de</strong>r Leitung<strong>en</strong>).<br />

Beacht<strong>en</strong> Sie diese Hinweise eb<strong>en</strong>so bei CE−gek<strong>en</strong>nzeichnet<strong>en</strong> Antriebsreglern.<br />

Der Hersteller <strong>de</strong>r Anlage o<strong>de</strong>r Maschine ist verantwortlich für die<br />

Einhaltung <strong>de</strong>r durch die EMV−Gesetzgebung gefor<strong>de</strong>rt<strong>en</strong> Gr<strong>en</strong>zwerte.<br />

Betrieb<br />

Sie müss<strong>en</strong> Anlag<strong>en</strong> mit eingebaut<strong>en</strong> Antriebsreglern ggf. mit zusätzlich<strong>en</strong><br />

Überwachungs− und Schutzeinrichtung<strong>en</strong> gemäß <strong>de</strong>n jeweils gültig<strong>en</strong> Sicherheitsbestimmung<strong>en</strong><br />

ausrüst<strong>en</strong> (z. B. Gesetz über technische Arbeitsmittel,<br />

Unfallverhütungsvorschrift<strong>en</strong>). Sie dürf<strong>en</strong> die Antriebsregler an Ihre<br />

Anw<strong>en</strong>dung anpass<strong>en</strong>. Beacht<strong>en</strong> Sie dazu die Hinweise in <strong>de</strong>r Dokum<strong>en</strong>tation.<br />

Nach<strong>de</strong>m <strong>de</strong>r Antriebsregler von <strong>de</strong>r Versorgungsspannung getr<strong>en</strong>nt ist,<br />

dürf<strong>en</strong> Sie spannungsführ<strong>en</strong><strong>de</strong> Geräteteile und Leistungsanschlüsse nicht<br />

sofort berühr<strong>en</strong>, weil Kon<strong>de</strong>nsator<strong>en</strong> aufgela<strong>de</strong>n sein könn<strong>en</strong>. Beacht<strong>en</strong> Sie<br />

dazu die <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>n Hinweisschil<strong>de</strong>r auf <strong>de</strong>m Antriebsregler.<br />

Halt<strong>en</strong> Sie währ<strong>en</strong>d <strong>de</strong>s Betriebs alle Schutzab<strong>de</strong>ckung<strong>en</strong> und Tür<strong>en</strong> geschloss<strong>en</strong>.<br />

Hinweis für UL−approbierte Anlag<strong>en</strong> mit eingebaut<strong>en</strong> Antriebsreglern:<br />

UL warnings sind Hinweise, die nur für UL−Anlag<strong>en</strong> gelt<strong>en</strong>. Die Dokum<strong>en</strong>tation<br />

<strong>en</strong>thält spezielle Hinweise zu UL.<br />

Sicherer Halt−2−<br />

Die Variante V004 <strong>de</strong>r Antriebsregler 9300 und 9300 vector, die Variante x4x<br />

<strong>de</strong>r Antriebsregler <strong>82</strong>00 vector und die Achsmodule ECSxAxxx unterstütz<strong>en</strong><br />

die Funktion "Sicherer Halt", Schutz geg<strong>en</strong> unerwartet<strong>en</strong> Anlauf, nach <strong>de</strong>n<br />

Anfor<strong>de</strong>rung<strong>en</strong> von Anhang I Nr. 1.2.7 <strong>de</strong>r EG−Richtlinie "Maschin<strong>en</strong>"<br />

98/37/EG, DIN EN 954−1 Kategorie 3 und DIN EN 1037. Beacht<strong>en</strong> Sie unbedingt<br />

die Hinweise zur Funktion "Sicherer Halt" in <strong>de</strong>r Dokum<strong>en</strong>tation zu <strong>de</strong>n<br />

Variant<strong>en</strong>.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 7


1 Sicherheitshinweise<br />

L<strong>en</strong>ze−Antriebsregler<br />

Wartung und Instandhaltung<br />

Die Antriebsregler sind wartungs<strong>fr</strong>ei, w<strong>en</strong>n die vorgeschrieb<strong>en</strong><strong>en</strong> Einsatzbedingung<strong>en</strong><br />

eingehalt<strong>en</strong> wer<strong>de</strong>n.<br />

Bei verunreinigter Umgebungsluft könn<strong>en</strong> die Kühlfläch<strong>en</strong> <strong>de</strong>s Antriebsreglers<br />

verschmutz<strong>en</strong> o<strong>de</strong>r Kühlöffnung<strong>en</strong> verstopft wer<strong>de</strong>n. Bei dies<strong>en</strong> Betriebsbedingung<strong>en</strong><br />

<strong>de</strong>shalb regelmäßig die Kühlfläch<strong>en</strong> und Kühlöffnung<strong>en</strong><br />

reinig<strong>en</strong>. Dazu niemals scharfe o<strong>de</strong>r spitze Geg<strong>en</strong>stän<strong>de</strong> verw<strong>en</strong><strong>de</strong>n!<br />

Entsorgung<br />

Metalle und Kunststoffe zur Wie<strong>de</strong>rverwertung geb<strong>en</strong>. Bestückte Leiterplatt<strong>en</strong><br />

fachgerecht <strong>en</strong>tsorg<strong>en</strong>.<br />

Beacht<strong>en</strong> Sie unbedingt die produktspezifisch<strong>en</strong> Sicherheits− und Anw<strong>en</strong>dungshinweise<br />

in dieser Anleitung!<br />

8<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

Drehstrommaschin<strong>en</strong><br />

1<br />

Allgemeine Sicherheits− und Anw<strong>en</strong><strong>de</strong>rhinweise für L<strong>en</strong>ze−Motor<strong>en</strong><br />

(gemäß Nie<strong>de</strong>rspannungsrichtlinie 73/23/EWG)<br />

Allgemein<br />

Nie<strong>de</strong>rspannungsmaschin<strong>en</strong> hab<strong>en</strong> gefährliche, spannungsführ<strong>en</strong><strong>de</strong> und<br />

rotier<strong>en</strong><strong>de</strong> Teile sowie möglicherweise heiße Oberfläch<strong>en</strong>. Alle Arbeit<strong>en</strong> zu<br />

Transport, Anschluss, Inbetriebnahme und Instandhaltung sind von qualifiziertem,<br />

verantwortlichem Fachpersonal auszuführ<strong>en</strong> (EN 50110−1 (VDE<br />

0105−100); IEC 60364 beacht<strong>en</strong>). Unsachgemäßes Verhalt<strong>en</strong> kann schwere<br />

Person<strong>en</strong>− und Sachschä<strong>de</strong>n verursach<strong>en</strong>.<br />

Bei Synchronmaschin<strong>en</strong> wer<strong>de</strong>n bei dreh<strong>en</strong><strong>de</strong>r Maschine auch an <strong>de</strong>n off<strong>en</strong><strong>en</strong><br />

Klemm<strong>en</strong> Spannung<strong>en</strong> induziert.<br />

Bestimmungsgemäße Verw<strong>en</strong>dung<br />

Diese Nie<strong>de</strong>rspannungsmaschin<strong>en</strong> sind für gewerbliche Anlag<strong>en</strong> bestimmt.<br />

Sie <strong>en</strong>tsprech<strong>en</strong> <strong>de</strong>n harmonisiert<strong>en</strong> Norm<strong>en</strong> <strong>de</strong>r Reihe EN60034 (VDE<br />

O53O). Der Einsatz im Ex−Bereich ist verbot<strong>en</strong>, sofern nicht ausdrücklich<br />

hierfür vorgeseh<strong>en</strong> (Zusatzhinweise beacht<strong>en</strong>).<br />

Schutzart<strong>en</strong> IP23 nicht ohne beson<strong>de</strong>re Schutzmaßnahm<strong>en</strong> im Frei<strong>en</strong> verw<strong>en</strong><strong>de</strong>n.<br />

Luftgekühlte Ausführung<strong>en</strong> sind für Umgebungstemperatur<strong>en</strong> von<br />

−15 °C bzw. −10 °C bis +40 °C und Aufstellungshöh<strong>en</strong> 1000 m üNN bemess<strong>en</strong>,<br />

von −20 °C bis +40 °C ohne Bremse o<strong>de</strong>r mit Fe<strong>de</strong>rkraftbremse,<br />

unbelüftet o<strong>de</strong>r mit Eig<strong>en</strong>lüfter, von −15 °C bis +40 °C mit Perman<strong>en</strong>tmagnetbremse<br />

und von −10 °C bis +40 °C mit Fremdlüfter. Abweich<strong>en</strong><strong>de</strong> Angab<strong>en</strong><br />

auf <strong>de</strong>m Leistungsschild unbedingt beacht<strong>en</strong>. Die Bedingung<strong>en</strong> am<br />

Einsatzort müss<strong>en</strong> all<strong>en</strong> Leistungsschildangab<strong>en</strong> <strong>en</strong>tsprech<strong>en</strong>.<br />

Nie<strong>de</strong>rspannungsmaschin<strong>en</strong> sind Kompon<strong>en</strong>t<strong>en</strong> zum Einbau in Maschin<strong>en</strong><br />

im Sinne <strong>de</strong>r Maschin<strong>en</strong>richtlinie 98/37/EG. Die Inbetriebnahme ist solange<br />

untersagt, bis die Konformität <strong>de</strong>s Endprodukts mit dieser Richtlinie festgestellt<br />

ist (u. a. EN 60204−1 beacht<strong>en</strong>).<br />

Die eingebaut<strong>en</strong> Brems<strong>en</strong> sind keine Sicherheitsbrems<strong>en</strong>. Es ist nicht auszuschließ<strong>en</strong>,<br />

dass durch nicht zu beeinfluss<strong>en</strong><strong>de</strong> Störfaktor<strong>en</strong>, z. B. Öleintritt<br />

durch Versag<strong>en</strong> <strong>de</strong>s A−seitig<strong>en</strong> Well<strong>en</strong>dichtrings, eine Drehmom<strong>en</strong>treduzierung<br />

auftret<strong>en</strong> kann.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 9


1 Sicherheitshinweise<br />

Drehstrommaschin<strong>en</strong><br />

Transport, Einlagerung<br />

Nach <strong>de</strong>r Auslieferung festgestellte Beschädigung<strong>en</strong> <strong>de</strong>m Transportunternehm<strong>en</strong><br />

sofort mitteil<strong>en</strong>; die Inbetriebnahme ist ggf. auszuschließ<strong>en</strong>. Eingeschraubte<br />

Transportös<strong>en</strong> fest anzieh<strong>en</strong>. Sie sind für das Gewicht <strong>de</strong>r Nie<strong>de</strong>rspannungsmaschine<br />

ausgelegt, keine zusätzlich<strong>en</strong> Last<strong>en</strong> anbring<strong>en</strong>.<br />

W<strong>en</strong>n notw<strong>en</strong>dig, ausreich<strong>en</strong>d bemess<strong>en</strong>e Transportmittel (z. B. Seilführung<strong>en</strong>)<br />

verw<strong>en</strong><strong>de</strong>n.<br />

Vorhan<strong>de</strong>ne Transportsicherung<strong>en</strong> vor Inbetriebnahme <strong>en</strong>tfern<strong>en</strong>. Für weitere<br />

Transporte erneut verw<strong>en</strong><strong>de</strong>n. Wer<strong>de</strong>n Nie<strong>de</strong>rspannungsmaschin<strong>en</strong><br />

eingelagert, auf eine trock<strong>en</strong>e, staub<strong>fr</strong>eie und schwingungsarme<br />

(v eff 0.2 mm/s) Umgebung acht<strong>en</strong> (Lagerstillstandsschä<strong>de</strong>n). Vor Inbetriebnahme<br />

Isolationswi<strong>de</strong>rstand mess<strong>en</strong>. Bei Wert<strong>en</strong> 1 k je Volt Bemessungsspannung<br />

Wicklung trockn<strong>en</strong>.<br />

Aufstellung<br />

Auf plane Auflage, gute Fuß− bzw. Flanschbefestigung und g<strong>en</strong>aue Ausrichtung<br />

bei direkter Kupplung acht<strong>en</strong>. Aufbaubedingte Resonanz<strong>en</strong> mit <strong>de</strong>r<br />

Dreh<strong>fr</strong>equ<strong>en</strong>z und <strong>de</strong>r doppelt<strong>en</strong> Speise<strong>fr</strong>equ<strong>en</strong>z vermei<strong>de</strong>n. Läufer von<br />

Hand dreh<strong>en</strong>, auf ungewöhnliche Schleifgeräusche acht<strong>en</strong>. Drehrichtung im<br />

ungekuppelt<strong>en</strong> Zustand kontrollier<strong>en</strong> (Abschn. 5 beacht<strong>en</strong>).<br />

Riem<strong>en</strong>scheib<strong>en</strong> und Kupplung<strong>en</strong> nur mit geeignet<strong>en</strong> Vorrichtung<strong>en</strong> auf−<br />

bzw. abzieh<strong>en</strong> (Erwärm<strong>en</strong>!) und mit einem Berührschutz ab<strong>de</strong>ck<strong>en</strong>. Unzulässige<br />

Riem<strong>en</strong>spannung<strong>en</strong> vermei<strong>de</strong>n (Techn. Liste).<br />

Die Maschin<strong>en</strong> sind mit halber Passfe<strong>de</strong>r gewuchtet. Die Kupplung muss<br />

eb<strong>en</strong>falls mit halber Passfe<strong>de</strong>r gewuchtet sein. Übersteh<strong>en</strong><strong>de</strong>n, sichtbar<strong>en</strong><br />

Passfe<strong>de</strong>ranteil abarbeit<strong>en</strong>.<br />

Ev<strong>en</strong>tuell erfor<strong>de</strong>rliche Rohranschlüsse herstell<strong>en</strong>. Bauform<strong>en</strong> mit Well<strong>en</strong><strong>en</strong><strong>de</strong><br />

nach unt<strong>en</strong> bauseits mit einer Ab<strong>de</strong>ckung ausrüst<strong>en</strong>, die verhin<strong>de</strong>rt,<br />

dass Fremdkörper in <strong>de</strong>n Lüfter hineinfall<strong>en</strong>. Die Belüftung darf nicht behin<strong>de</strong>rt<br />

wer<strong>de</strong>n und die Abluft − auch b<strong>en</strong>achbarter Aggregate − nicht unmittelbar<br />

wie<strong>de</strong>r angesaugt wer<strong>de</strong>n.<br />

10<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

Drehstrommaschin<strong>en</strong><br />

Elektrischer Anschluss<br />

Alle Arbeit<strong>en</strong> dürf<strong>en</strong> nur von qualifiziertem Fachpersonal an <strong>de</strong>r stillsteh<strong>en</strong><strong>de</strong>n<br />

Nie<strong>de</strong>rspannungsmaschine im <strong>fr</strong>eigeschaltet<strong>en</strong> und geg<strong>en</strong> Wie<strong>de</strong>reinschalt<strong>en</strong><br />

gesichert<strong>en</strong> Zustand vorg<strong>en</strong>omm<strong>en</strong> wer<strong>de</strong>n. Das gilt auch für Hilfsstromkreise<br />

(z. B. Bremse, Geber, Fremdlüfter).<br />

Spannungs<strong>fr</strong>eiheit prüf<strong>en</strong>!<br />

Überschreit<strong>en</strong> <strong>de</strong>r Toleranz<strong>en</strong> in EN 60034−1; IEC 34 (VDE 0530−1) − Spannung<br />

±5 %, Frequ<strong>en</strong>z ±2 %, Kurv<strong>en</strong>form, Symmetrie − erhöht die Erwärmung<br />

und beeinflusst die elektromagnetische Verträglichkeit.<br />

Schaltungshinweise, Angab<strong>en</strong> auf <strong>de</strong>m Leistungsschild und Anschlussschema<br />

im Anschlusskast<strong>en</strong> beacht<strong>en</strong>.<br />

Der Anschluss muss so erfolg<strong>en</strong>, dass eine dauerhaft sichere, elektrische<br />

Verbindung au<strong>fr</strong>echt erhalt<strong>en</strong> wird (keine absteh<strong>en</strong><strong>de</strong>n Draht<strong>en</strong><strong>de</strong>n); zugeordnete<br />

Kabel<strong>en</strong>dbestückung verw<strong>en</strong><strong>de</strong>n. Sichere Schutzleiterverbindung<br />

herstell<strong>en</strong>. Steckverbin<strong>de</strong>r bis zum Anschlag festschraub<strong>en</strong>.<br />

Die kleinst<strong>en</strong> Luftabstän<strong>de</strong> dürf<strong>en</strong> zwisch<strong>en</strong> blank<strong>en</strong>, spannungsführ<strong>en</strong><strong>de</strong>n<br />

Teil<strong>en</strong> und geg<strong>en</strong> Er<strong>de</strong> folg<strong>en</strong><strong>de</strong> Werte nicht unterschreit<strong>en</strong>: 8 mm bei<br />

U N 550 V, 10 mm bei U N 725 V, 14 mm bei U N 1000 V.<br />

Der Anschlusskast<strong>en</strong> muss <strong>fr</strong>ei sein von Fremdkörpern, Schmutz und<br />

Feuchtigkeit. Nicht b<strong>en</strong>ötigte Kabeleinführungsöffnung<strong>en</strong> und <strong>de</strong>n Kast<strong>en</strong><br />

selbst staub− und wasserdicht verschließ<strong>en</strong>. Für <strong>de</strong>n Probebetrieb ohne Abtriebselem<strong>en</strong>te<br />

Passfe<strong>de</strong>r sichern. Bei Nie<strong>de</strong>rspannungsmaschin<strong>en</strong> mit<br />

Bremse vor <strong>de</strong>r Inbetriebnahme die einwand<strong>fr</strong>eie Funktion <strong>de</strong>r Bremse prüf<strong>en</strong>.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 11


1 Sicherheitshinweise<br />

Drehstrommaschin<strong>en</strong><br />

Betrieb<br />

Schwingstärk<strong>en</strong> v eff 3.5 mm/s (P N 15 <strong>kW</strong>) bzw. 4.5 mm/s (P N > 15 <strong>kW</strong>)<br />

sind in gekuppeltem Betrieb unbe<strong>de</strong>nklich. Bei Verän<strong>de</strong>rung<strong>en</strong> geg<strong>en</strong>über<br />

<strong>de</strong>m Normalbetrieb, z. B. erhöhte Temperatur<strong>en</strong>, Geräusche, Schwingung<strong>en</strong>,<br />

Ursache ermitteln, ggf. Rücksprache mit <strong>de</strong>m Hersteller. Im Zweifelsfall<br />

Nie<strong>de</strong>rspannungsmaschine abschalt<strong>en</strong>.<br />

Bei starkem Schmutzanfall Luftwege regelmäßig reinig<strong>en</strong>.<br />

Schutzeinrichtung<strong>en</strong> auch im Probebetrieb nicht außer Funktion setz<strong>en</strong>.<br />

Eingebaute Temperaturfühler sind kein Vollschutz <strong>de</strong>r Maschine, ggf. Maximalstrom<br />

begr<strong>en</strong>z<strong>en</strong>. Funktionsblockverschaltung mit Abschaltung nach<br />

einig<strong>en</strong> Sekun<strong>de</strong>n Betrieb mit I > I N vornehm<strong>en</strong>, insbeson<strong>de</strong>re bei Gefahr<br />

<strong>de</strong>s Blockier<strong>en</strong>s.<br />

Well<strong>en</strong>dichtringe und Wälzlager hab<strong>en</strong> eine begr<strong>en</strong>zte Leb<strong>en</strong>sdauer.<br />

Lagerung<strong>en</strong> mit Nachschmiereinrichtung bei lauf<strong>en</strong><strong>de</strong>r Nie<strong>de</strong>rspannungsmaschine<br />

nachfett<strong>en</strong>. Verseifungsart beacht<strong>en</strong>. W<strong>en</strong>n Fettaustrittsbohrung<strong>en</strong><br />

mit Stopf<strong>en</strong> verschloss<strong>en</strong> sind (IP54 Abtriebsseite; IP23 Abtriebs−und<br />

Nichtabtriebsseite), vor Inbetriebnahme Stopf<strong>en</strong> <strong>en</strong>tfern<strong>en</strong>. Bohrung<strong>en</strong> mit<br />

Fett verschließ<strong>en</strong>. Lagerwechsel bei Dauerschmierung (2Z−Lager) nach ca.<br />

10.000 h − 20.000 h, spätest<strong>en</strong>s jedoch nach 3 − 4 Jahr<strong>en</strong> bzw. nach Herstellerangab<strong>en</strong>.<br />

12<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

Restgefahr<strong>en</strong>, Gestaltung <strong>de</strong>r Sicherheitshinweise<br />

1<br />

Restgefahr<strong>en</strong><br />

Person<strong>en</strong>schutz<br />

Schalt<strong>en</strong> Sie vor Arbeitsbeginn / Öffn<strong>en</strong> <strong>de</strong>s Gerätes <strong>de</strong>n<br />

Antriebsregler spannungslos und wart<strong>en</strong> Sie min<strong>de</strong>st<strong>en</strong>s 3 Minut<strong>en</strong>,<br />

da nach <strong>de</strong>m Netzabschalt<strong>en</strong> die Leistungsklemm<strong>en</strong> U, V, W; BR0,<br />

BR1, BR2 und die Pins <strong>de</strong>r Schnittstelle FIF gefährliche Spannung<br />

führ<strong>en</strong>.<br />

– Überprüf<strong>en</strong> Sie nach <strong>de</strong>m Öffn<strong>en</strong> <strong>de</strong>s <strong>motec</strong>, ob die<br />

Leistungsklemm<strong>en</strong> L1, L2, L3; U, V, W; BR0, BR1, BR2, die<br />

Relaisausgänge K11, K12, K14 und die Pins <strong>de</strong>r Schnittstelle FIF<br />

spannungslos sind.<br />

– Auch bei vom Netz getr<strong>en</strong>ntem Antriebsregler könn<strong>en</strong> die<br />

Relaisausgänge K11, K12, K14 gefährliche Spannung führ<strong>en</strong>!<br />

W<strong>en</strong>n Sie die nicht drahtbruchsichere Funktion<br />

Drehrichtungsvorgabe" über das digitale Signal CW/CCW verw<strong>en</strong><strong>de</strong>n<br />

(C0007 = −0− ... −13−, C0410/3 255):<br />

– Bei Drahtbruch o<strong>de</strong>r bei Ausfall <strong>de</strong>r Steuerspannung kann <strong>de</strong>r<br />

Antrieb die Drehrichtung wechseln.<br />

W<strong>en</strong>n Sie die Funktion "Fangschaltung" (C0142 = −2−, −3−) bei<br />

Maschin<strong>en</strong> mit geringem Mass<strong>en</strong>trägheitsmom<strong>en</strong>t und geringer<br />

Reibung verw<strong>en</strong><strong>de</strong>n:<br />

– Nach Regler<strong>fr</strong>eigabe im Stillstand kann <strong>de</strong>r Motor kurzzeitig<br />

anlauf<strong>en</strong> o<strong>de</strong>r kurzzeitig die Drehrichtung wechseln.<br />

Der Kühlkörper <strong>de</strong>s <strong>motec</strong> hat eine Betriebstemperatur > 60 °C:<br />

– Hautkontakt mit <strong>de</strong>m Kühlkörper führt zu Verbr<strong>en</strong>nung<strong>en</strong>.<br />

Motorschutz<br />

Bei bestimmt<strong>en</strong> Einstellung<strong>en</strong> <strong>de</strong>r Antriebsregler kann <strong>de</strong>r<br />

angeschloss<strong>en</strong>e Motor überhitzt wer<strong>de</strong>n:<br />

– Z. B. längerer Betrieb <strong>de</strong>r Gleichstrombremse.<br />

– Längerer Betrieb eig<strong>en</strong>belüfteter Motor<strong>en</strong> bei klein<strong>en</strong> Drehzahl<strong>en</strong>.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 13


1 Sicherheitshinweise<br />

Restgefahr<strong>en</strong>, Gestaltung <strong>de</strong>r Sicherheitshinweise<br />

Schutz <strong>de</strong>r Maschine/Anlage<br />

Antriebe könn<strong>en</strong> gefährliche Überdrehzahl<strong>en</strong> erreich<strong>en</strong> (z. B.<br />

Einstellung hoher Ausgangs<strong>fr</strong>equ<strong>en</strong>z<strong>en</strong> bei dafür ungeeignet<strong>en</strong><br />

Motor<strong>en</strong> und Maschin<strong>en</strong>):<br />

– Die Antriebsregler biet<strong>en</strong> kein<strong>en</strong> Schutz geg<strong>en</strong> solche<br />

Betriebsbedingung<strong>en</strong>. Setz<strong>en</strong> Sie dafür zusätzliche Kompon<strong>en</strong>t<strong>en</strong><br />

ein.<br />

Schütze in <strong>de</strong>r Motorleitung nur bei gesperrtem Regler schalt<strong>en</strong>.<br />

Wer<strong>de</strong>n Schütze in <strong>de</strong>r Motorleitung bei <strong>fr</strong>eigegeb<strong>en</strong>em Regler geschaltet,<br />

– könn<strong>en</strong> Überwachungsfunktion<strong>en</strong> <strong>de</strong>s Antriebsreglers ansprech<strong>en</strong>.<br />

– kann <strong>de</strong>r Antriebsregler unter ungünstig<strong>en</strong> Betriebsbedingung<strong>en</strong><br />

zerstört wer<strong>de</strong>n.<br />

Warnings!<br />

The <strong>de</strong>vice has no overspeed protection.<br />

Must be provi<strong>de</strong>d with external or remote overload protection.<br />

Suitable for use on a circuit capable of <strong>de</strong>livering not more<br />

than 5000 rms symmetrical amperes, 240 V maximum (240 V<br />

<strong>de</strong>vices) or 500 V maximum (400/500 V <strong>de</strong>vices) resp.<br />

Circuit breakers (either inverse−time or instantaneous trip<br />

types) may be used in lieu of above fuses wh<strong>en</strong> it is shown<br />

that the let−through <strong>en</strong>ergy (I 2 t) and peak let−through curr<strong>en</strong>t<br />

(Ip) of the inverse−time curr<strong>en</strong>t−limiting circuit breaker will be<br />

less than that of the non−semiconductor type K5 fuses with<br />

which the drive has be<strong>en</strong> tested. An inverse−time circuit<br />

breaker may be used, sized upon the input rating of the drive,<br />

multiplied by 300 %.<br />

Use 60/75 °C or 75 °C copper wire only.<br />

If mounted on a motor the <strong>en</strong>vironm<strong>en</strong>tal rating tests for<br />

Type 4 and Type 12 shall be performed.<br />

14<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Sicherheitshinweise<br />

Restgefahr<strong>en</strong>, Gestaltung <strong>de</strong>r Sicherheitshinweise<br />

Gestaltung <strong>de</strong>r Sicherheitshinweise<br />

Alle Sicherheitshinweise in dieser Anleitung sind einheitlich aufgebaut:<br />

Piktogramm (k<strong>en</strong>nzeichnet die Art <strong>de</strong>r Gefahr)<br />

Signalwort! (k<strong>en</strong>nzeichnet die Schwere <strong>de</strong>r Gefahr)<br />

Hinweistext (beschreibt die Gefahr und gibt Hinweise, wie sie<br />

vermie<strong>de</strong>n wer<strong>de</strong>n kann)<br />

Piktogramm Signalwort Folg<strong>en</strong> bei Mißachtung<br />

Signalwort<br />

Be<strong>de</strong>utung<br />

<strong>de</strong>r Sicherheitshinweise<br />

Gefahr! Unmittelbar droh<strong>en</strong><strong>de</strong> Gefahr Tod o<strong>de</strong>r schwerste Verletzung<strong>en</strong><br />

für Person<strong>en</strong><br />

<br />

gefährliche elektrische<br />

Spannung<br />

<br />

allgemeine Gefahr<br />

<br />

<br />

Warnung!<br />

Vorsicht!<br />

Mögliche, sehr gefährliche Situation<br />

für Person<strong>en</strong><br />

Mögliche, gefährliche Situation<br />

für Person<strong>en</strong><br />

1<br />

Tod o<strong>de</strong>r schwerste Verletzung<strong>en</strong><br />

Leichte Verletzung<strong>en</strong><br />

Stop! Mögliche Sachschä<strong>de</strong>n Beschädigung <strong>de</strong>s Antriebssystems<br />

o<strong>de</strong>r seiner<br />

Umgebung<br />

Hinweis! Nützlicher Hinweis o<strong>de</strong>r Tipp<br />

W<strong>en</strong>n Sie ihn befolg<strong>en</strong>, erleichtern<br />

Sie sich die Handhabung <strong>de</strong>s<br />

Antriebssystems.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 15


2<br />

Technische Dat<strong>en</strong><br />

Norm<strong>en</strong> und Einsatzbedingung<strong>en</strong><br />

Konformität CE Nie<strong>de</strong>rspannungsrichtlinie (73/23/EWG)<br />

Approbation<strong>en</strong> UL 508C Un<strong>de</strong>rwriter Laboratories (File−No. E132659)<br />

Power Conversion Equipm<strong>en</strong>t<br />

Rüttelfestigkeit<br />

Beschleunigungsfest bis 2g (Germanischer Lloyd, allgemeine Bedingung<strong>en</strong>)<br />

Klimatische Bedingung<strong>en</strong> Klasse 3K3 nach EN 50178 (ohne Betauung, mittlere relative Feuchte 85 %)<br />

Zulässige Temperaturbereiche<br />

Transport −25 °C ... +70 °C<br />

Lagerung −25 °C ... +60 °C<br />

Betrieb −20 °C ... +60 °C<br />

über +40 °C Ausgangs−Bemessungsstrom um 2,5 %/°C reduzier<strong>en</strong><br />

Zulässige Aufstellungshöhe 0 ... 4000 m üNN<br />

über 1000 m üNN Ausgangs−Bemessungsstrom um 5 %/1000 m reduzier<strong>en</strong><br />

Einbaulag<strong>en</strong><br />

Je<strong>de</strong> Einbaulage und Einbau−Ausrichtung zulässig<br />

Einbau<strong>fr</strong>eiräume oberhalb 100 mm<br />

seitlich 100 mm<br />

16<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Technische Dat<strong>en</strong><br />

Allgemeine elektrische Dat<strong>en</strong><br />

2<br />

Allgemeine elektrische Dat<strong>en</strong><br />

EMV1.<br />

Einhaltung <strong>de</strong>r Anfor<strong>de</strong>rung<strong>en</strong> nach EN 61800−3/A11<br />

Störauss<strong>en</strong>dung Motormontage Einhaltung <strong>de</strong>r Gr<strong>en</strong>zwertklass<strong>en</strong> A und B nach<br />

EN 55011<br />

Wandmontage Einhaltung <strong>de</strong>r Gr<strong>en</strong>zwertklasse A nach<br />

EN 55011<br />

(bis 10 m geschirmte Motorleitung)<br />

Einhaltung <strong>de</strong>r Gr<strong>en</strong>zwertklasse B nach<br />

EN 55011<br />

(bis 1 m geschirmte Motorleitung)<br />

Ableitstrom geg<strong>en</strong> PE > 3.5 mA<br />

(nach EN 50178)<br />

Schutzart 2. IP 55<br />

ohne Schutzkappe auf <strong>de</strong>r AIF−Schnittstelle<br />

(NEMA 250 Typ 12)<br />

IP 65<br />

mit Schutzkappe auf <strong>de</strong>r AIF−Schnittstelle<br />

(NEMA 250 Typ 4)<br />

Schutzmaßnahm<strong>en</strong> geg<strong>en</strong> Kurzschluß, Erdschluß (erdschlußfest im Betrieb, eingeschränkt erdschlußfest<br />

beim Netzeinschalt<strong>en</strong>), Überspannung, Kipp<strong>en</strong> <strong>de</strong>s Motors, Motor−<br />

Übertemperatur (Eingang für Kaltleiter (PTC) o<strong>de</strong>r Thermokontakt (Öffner),<br />

I 2 t−Überwachung)<br />

Schutzisolierung von Steuerschaltkreis<strong>en</strong><br />

Betrieb an öff<strong>en</strong>tlich<strong>en</strong> Netz<strong>en</strong><br />

(Begr<strong>en</strong>zung von Oberschwingungsström<strong>en</strong><br />

nach<br />

EN 61000−3−2)<br />

Sichere Tr<strong>en</strong>nung vom Netz:<br />

Doppelte/verstärkte Isolierung nach EN 50178<br />

Gesamtleistung am Netz Einhaltung <strong>de</strong>r Anfor<strong>de</strong>rung<strong>en</strong> 1)<br />

0.25 <strong>kW</strong> ... 0.75 <strong>kW</strong> mit Netzdrossel<br />

> 1 <strong>kW</strong> ohne zusätzliche Maßnahm<strong>en</strong><br />

1) Die g<strong>en</strong>annt<strong>en</strong> Zusatzmaßnahm<strong>en</strong> bewirk<strong>en</strong>, daß alleinig die Antriebsregler die<br />

Anfor<strong>de</strong>rung<strong>en</strong> <strong>de</strong>r EN 61000−3−2 erfüll<strong>en</strong>. Die Einhaltung <strong>de</strong>r Anfor<strong>de</strong>rung<strong>en</strong> für die<br />

Maschine/Anlage liegt in <strong>de</strong>r Verantwortung <strong>de</strong>s Maschin<strong>en</strong>−/Anlag<strong>en</strong>herstellers!<br />

Betrieb mit Bemessungsleistung<br />

typische Motorleistung P N [KW] <strong>0.55</strong> 0.75 1.5 <strong>2.2</strong><br />

<strong>82</strong>00 <strong>motec</strong> Typ E<strong>82</strong>MV551_4B E<strong>82</strong>MV751_4B E<strong>82</strong>MV152_4B E<strong>82</strong>MV222_4B<br />

Netzspannungsbereich U N [V]<br />

3/PE AC; 320 V − 0 % ... 550 V + 0 %<br />

(45 Hz − 0 % ... 65 Hz + 0 %)<br />

Dat<strong>en</strong> für <strong>de</strong>n Betrieb an 3 PE AC 400 V 400 V 400 V 400 V<br />

Netz−Bemessungsstrom I N [A] 1.8 2.4 3.8 5.5<br />

Ausgangsstrom 8 kHz * I N8 [A] 1.8 2.4 3.9 5.6<br />

Max. zulässiger Ausgangsstrom<br />

für 60 s<br />

* Schalt<strong>fr</strong>equ<strong>en</strong>z <strong>de</strong>s Wechselrichters<br />

8 kHz * I max8 [A] 2.7 3.6 5.8 8.4<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 17


2<br />

Technische Dat<strong>en</strong><br />

Abmessung<strong>en</strong>, Mechanische Ausführung<br />

Abmessung<strong>en</strong><br />

c<br />

b<br />

a<br />

f<br />

d<br />

e<br />

<strong>82</strong>00mot001<br />

Typ a [mm] b [mm] c [mm] d [mm] e [mm] f [mm]<br />

E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Mechanische Ausführung<br />

156 151 135 202 15 26<br />

176 167 151 230 15 26<br />

Typ Verschraubung<strong>en</strong> Gewicht<br />

E<strong>82</strong>MV551_4B 2 × M25 (Gewin<strong>de</strong>länge 10 mm, ohne Geg<strong>en</strong>mutter)<br />

E<strong>82</strong>MV751_4B 4 × M16 (Gewin<strong>de</strong>länge 10 mm, ohne Geg<strong>en</strong>mutter)<br />

1 × M20 für Motorleitung bei Wandmontage (EMV−Kabelverschraubung,<br />

2.8 kg<br />

Gewin<strong>de</strong>länge 10 mm, mit Geg<strong>en</strong>mutter)<br />

E<strong>82</strong>MV152_4B 1 × M20 (Gewin<strong>de</strong>länge 10 mm, ohne Geg<strong>en</strong>mutter)<br />

E<strong>82</strong>MV222_4B 2 × M25 (Gewin<strong>de</strong>länge 10 mm, ohne Geg<strong>en</strong>mutter)<br />

4 × M16 (Gewin<strong>de</strong>länge 10 mm, ohne Geg<strong>en</strong>mutter)<br />

4.1 kg<br />

1 × M20 für Motorleitung bei Wandmontage (EMV−Kabelverschraubung,<br />

Gewin<strong>de</strong>länge 10 mm, mit Geg<strong>en</strong>mutter)<br />

18<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


<strong>motec</strong> mit Motor o<strong>de</strong>r Getriebemotor<br />

Montage<br />

3<br />

Gefahr!<br />

Alle Steuerklemm<strong>en</strong> sind nach <strong>de</strong>m Anschluß eines Kaltleiters<br />

(PTC) o<strong>de</strong>r eines Thermokontakts nur noch basisisoliert<br />

(einfache Tr<strong>en</strong>nstrecke).<br />

Berührsicherheit bei <strong>de</strong>fekter Tr<strong>en</strong>nstrecke ist nur durch<br />

externe Maßnahm<strong>en</strong> gewährleistet, z. B. doppelte Isolierung.<br />

1b<br />

1a<br />

1a<br />

Abb. 1<br />

X1<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

1a<br />

<strong>82</strong>00mot002<br />

31<br />

Motortemperatur−Überwachung mit C0119 aktivier<strong>en</strong> (z. B. C0119 = 1)!<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 19


3<br />

<strong>motec</strong> mit Motor o<strong>de</strong>r Getriebemotor<br />

EMV−gerechte Verdrahtung<br />

Bedingung<strong>en</strong> für störungs<strong>fr</strong>ei<strong>en</strong> Betrieb:<br />

<br />

<br />

<br />

Mit Ausnahme <strong>de</strong>r Netzleitung nur geschirmte Leitung<strong>en</strong> verw<strong>en</strong><strong>de</strong>n.<br />

Schirmung sorgfältig auf PE leg<strong>en</strong>.<br />

Motor− und Netz−Schutzleiter an getr<strong>en</strong>nte PE−Klemm<strong>en</strong> schraub<strong>en</strong>.<br />

Schirmauflage:<br />

1. Leitung vorbereit<strong>en</strong><br />

X1<br />

A<br />

B<br />

F<br />

2. Leitung durch Öse<br />

<strong>de</strong>s Schirmblechs<br />

führ<strong>en</strong> und Öse umbieg<strong>en</strong>.<br />

C<br />

D<br />

E<br />

3. Öse mit Schirmblech<br />

verschraub<strong>en</strong>.<br />

Die Abschirmung<br />

muß fest mit <strong>de</strong>m<br />

Schirmblech verbun<strong>de</strong>n<br />

sein.<br />

0.7 Nm<br />

6 lb-in<br />

<strong>82</strong>00mot101<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

PES<br />

Netzleitung L1, L2, L3, PE<br />

PE−Anschluß Netzleitung<br />

Geschirmte Steuerleitung<br />

Schirmauflage Steuerleitung (Schirm mit Schirmblech fest verschraub<strong>en</strong>)<br />

Funktionsmodul<br />

Pot<strong>en</strong>tial<strong>fr</strong>eie Klemme (z. B. Sternpunkt bei Sternschaltung <strong>de</strong>s Motors)<br />

Klemm<strong>en</strong>leiste Netzanschluß<br />

HF−Schirmabschluß durch großflächige Anbindung an PE<br />

20<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Wandmontage<br />

Lieferumfang<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Abb. 2<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Trägergehäuse<br />

1b Elektronikmodul<br />

2a Dichtung<br />

3 Distanz− und Wandplatte<br />

4a Verschlußplatte Wandmontage<br />

4b Schraub<strong>en</strong> Wandmontage<br />

5a Schirmblech<br />

5b Schraub<strong>en</strong> Schirmblech (zur Befestigung <strong>de</strong>r Schirmung am Schirmblech)<br />

X1 Klemm<strong>en</strong>leiste Netzanschluß, Relais, Bremswi<strong>de</strong>rstand<br />

X2 Klemm<strong>en</strong>leiste Motoranschluß, Kaltleiter (PTC) bzw. Thermokontakt (Öffner)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 21


3 Wandmontage<br />

Vorbereitung<br />

a<br />

c<br />

b<br />

3<br />

4a<br />

2a<br />

d<br />

1×M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 ×M25<br />

4 ×M16<br />

Abb. 3<br />

5.3 mm<br />

3 3<br />

A<br />

1 ×M20<br />

1a<br />

1a<br />

e<br />

3<br />

2a<br />

5a<br />

<strong>82</strong>00mot004<br />

1a<br />

4b<br />

3.4Nm<br />

30 lb-in<br />

Kabelverschraubung aus Metall für die Motorleitung (z. B. EMV−Kabelverschraubung)<br />

22<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Wandmontage<br />

Vorbereitung<br />

Distanz− und Wandplatte Bohrbild Abstand<br />

a [mm] b [mm] c [mm] d [mm] e [mm]<br />

85 152 61 120 26<br />

85 172 61 140 26<br />

3<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 23


3 Wandmontage<br />

Motoranschluß<br />

Gefahr!<br />

Alle Steuerklemm<strong>en</strong> sind nach <strong>de</strong>m Anschluß eines Kaltleiters<br />

(PTC) o<strong>de</strong>r eines Thermokontakts nur noch basisisoliert<br />

(einfache Tr<strong>en</strong>nstrecke).<br />

Berührsicherheit bei <strong>de</strong>fekter Tr<strong>en</strong>nstrecke ist nur durch<br />

externe Maßnahm<strong>en</strong> gewährleistet, z. B. doppelte Isolierung.<br />

X2 T1 T2 PE W V U<br />

X2<br />

T1 T2<br />

PE<br />

W V U<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

T1<br />

T2<br />

<br />

PE<br />

5.5 mm<br />

2.5 mm<br />

2<br />

AWG 12<br />

6mm<br />

X2<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

1a<br />

B<br />

A<br />

3.4 Nm<br />

30 lb-in<br />

Abb. 4<br />

3.4 Nm<br />

30 lb-in<br />

<strong>82</strong>00mot006<br />

1a<br />

<br />

Kapazitätsarme Motorleitung verw<strong>en</strong><strong>de</strong>n! (A<strong>de</strong>r/A<strong>de</strong>r 75 pF/m, A<strong>de</strong>r/Schirm 150 pF/m)<br />

Eine möglichst kurze Motorleitung wirkt sich positiv auf das Antriebsverhalt<strong>en</strong> aus!<br />

Leitungsquerschnitte U, V, W, PE:<br />

E<strong>82</strong>MV551_4B, E<strong>82</strong>MV751_4B 1 mm 2 (AWG 18), geschirmt<br />

E<strong>82</strong>MV222_4B, E<strong>82</strong>MV152_4B 1.5 mm 2 (AWG 16), geschirmt<br />

Für die Motortemperatur−Überwachung separate Leitung (geschirmt) zu X2/T1 und X2/T2 verleg<strong>en</strong>.<br />

Steuerleitung<strong>en</strong> und Netzleitung<strong>en</strong> von <strong>de</strong>r Motorleitung räumlich getr<strong>en</strong>nt verleg<strong>en</strong>!<br />

24<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


V<br />

Wandmontage<br />

Motoranschluß<br />

3<br />

X2<br />

T1<br />

T2 PE W<br />

U<br />

PES<br />

PES<br />

PES<br />

PE<br />

<br />

M<br />

3~<br />

PES<br />

PTC<br />

M<br />

3~<br />

31<br />

<strong>82</strong>00mot168<br />

PES HF−Schirmabschluß durch PE−Anbindung über Schirmauflage ( 26) bzw. Motor−EMV−Verschraubung.<br />

X2/T1, Anschlußklemm<strong>en</strong> Motortemperatur−Überwachung mit Kaltleiter (PTC) o<strong>de</strong>r Thermokontakt (Öffner).<br />

X2/T2 Motortemperatur−Überwachung mit C0119 aktivier<strong>en</strong> (z. B. C0119 = 1)!<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 25


3 Wandmontage<br />

EMV−gerechte Verdrahtung<br />

Bedingung<strong>en</strong> für störungs<strong>fr</strong>ei<strong>en</strong> Betrieb:<br />

<br />

<br />

<br />

<br />

A<br />

C<br />

F<br />

Außer <strong>de</strong>r Netzleitung nur geschirmte Leitung<strong>en</strong> verw<strong>en</strong><strong>de</strong>n.<br />

Schirmung sorgfältig auf PE leg<strong>en</strong>.<br />

Steuer− und Netzleitung räumlich getr<strong>en</strong>nt von Motorleitung verleg<strong>en</strong>!<br />

Motor− und Netz−Schutzleiter an getr<strong>en</strong>nte PE−Klemm<strong>en</strong> schraub<strong>en</strong>.<br />

D<br />

B<br />

E<br />

G<br />

X1<br />

J<br />

X2<br />

H<br />

I<br />

Schirmauflage:<br />

1. Leitung vorbereit<strong>en</strong><br />

2. Leitung durch Öse <strong>de</strong>s<br />

Schirmblechs führ<strong>en</strong><br />

und Öse umbieg<strong>en</strong>.<br />

3. Öse mit Schirmblech<br />

verschraub<strong>en</strong>. Die Abschirmung<br />

muß fest mit<br />

<strong>de</strong>m Schirmblech verbun<strong>de</strong>n<br />

sein.<br />

0.7 Nm<br />

6 lb-in<br />

Abb. 5<br />

<strong>82</strong>00mot100<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

X2<br />

PES<br />

26<br />

Netzleitung L1, L2, L3, PE<br />

PE−Anschluß Netzleitung<br />

Geschirmte Motorleitung (kapazitätsarme Motorleitung<strong>en</strong> verw<strong>en</strong><strong>de</strong>n)<br />

EMV−Kabelverschraubung für die Motorleitung<br />

PE−Anschluß Motorleitung<br />

Geschirmte Steuerleitung<br />

Schirmauflage Steuerleitung (Schirm mit Schirmblech fest verschraub<strong>en</strong>)<br />

PE−Anschluß Klemm<strong>en</strong>leiste X2<br />

Pot<strong>en</strong>tial<strong>fr</strong>eie Klemme (z. B. Sternpunkt bei Sternschaltung <strong>de</strong>s Motors)<br />

Funktionsmodul<br />

Klemm<strong>en</strong>leiste Netzanschluß<br />

Klemm<strong>en</strong>leiste Motoranschluß<br />

HF−Schirmabschluß durch großflächige Anbindung an PE<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Motormontage<br />

Lieferumfang<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Abb. 6<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Trägergehäuse<br />

1b Elektronikmodul<br />

2a Dichtung<br />

3 Distanz− und Wandplatte<br />

4a Verschlußplatte Wandmontage<br />

4b Schraub<strong>en</strong> Wandmontage<br />

5a Schirmblech<br />

5b Schraub<strong>en</strong> Schirmblech (zur Befestigung <strong>de</strong>r Schirmung am Schirmblech)<br />

X1 Klemm<strong>en</strong>leiste Netzanschluß, Relais, Bremswi<strong>de</strong>rstand<br />

X2 Klemm<strong>en</strong>leiste Motoranschluß, Kaltleiter (PTC) bzw. Thermokontakt (Öffner)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 27


3 Motormontage<br />

Vorbereitung<br />

<br />

68-73mm<br />

68-73mm<br />

3.4 Nm<br />

30 lb-in<br />

5mm<br />

<br />

<br />

5a<br />

1a<br />

Abb. 7<br />

2a<br />

<br />

3<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/<br />

E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

2a<br />

1a<br />

<strong>82</strong>00mot007<br />

Vorbereit<strong>en</strong><strong>de</strong> Arbeit<strong>en</strong> am Motor:<br />

Klemm<strong>en</strong>kast<strong>en</strong>dichtung und Motor−Klemmbrett <strong>en</strong>tfern<strong>en</strong>.<br />

Ggf. Motorleitung verlängern.<br />

Gehäusewanne auf Motor montier<strong>en</strong>:<br />

Die verw<strong>en</strong><strong>de</strong>te Befestigung muß die mechanische Verbindung dauerhaft gewährleist<strong>en</strong>, z. B. durch Einsatz<br />

von Fächerscheib<strong>en</strong> (DIN 6798).<br />

W<strong>en</strong>n Distanz erfor<strong>de</strong>rlich: (2a), (3) und Schraube 35 mm (DIN 7985) verw<strong>en</strong><strong>de</strong>n (ohne : nur Schraube<br />

20 mm (DIN 7985))<br />

Schutzart IP65 ist nur bei sorgfältiger Abdichtung gewährleistet.<br />

28<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


5.5 mm<br />

Motormontage<br />

Motoranschluß<br />

3<br />

Gefahr!<br />

Alle Steuerklemm<strong>en</strong> sind nach <strong>de</strong>m Anschluß eines Kaltleiters<br />

(PTC) o<strong>de</strong>r eines Thermokontakts nur noch basisisoliert<br />

(einfache Tr<strong>en</strong>nstrecke).<br />

Berührsicherheit bei <strong>de</strong>fekter Tr<strong>en</strong>nstrecke ist nur durch<br />

externe Maßnahm<strong>en</strong> gewährleistet, z. B. doppelte Isolierung.<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

W2 U2 V2<br />

2.5 mm<br />

2<br />

AWG 12<br />

X2<br />

T1<br />

T1 T2 PE W<br />

T2<br />

V<br />

U<br />

U1 V1 W1 PE<br />

6mm<br />

PE<br />

<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

X2<br />

Abb. 8<br />

3.4 Nm<br />

30 lb-in<br />

3.4 Nm<br />

30 lb-in<br />

1a<br />

T1 T2 PE W V U<br />

<strong>82</strong>00mot008<br />

1a<br />

X2/T1,<br />

X2/T2<br />

L<br />

Anschlußklemm<strong>en</strong> Motortemperatur−Überwachung mit Kaltleiter (PTC) o<strong>de</strong>r Thermokontakt (Öffner).<br />

Motortemperatur−Überwachung mit C0119 aktivier<strong>en</strong> (z. B. C0119 = 1)!<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 29


3 Motormontage<br />

EMV−gerechte Verdrahtung<br />

Bedingung<strong>en</strong> für störungs<strong>fr</strong>ei<strong>en</strong> Betrieb:<br />

<br />

<br />

<br />

Außer <strong>de</strong>r Netzleitung nur geschirmte Leitung<strong>en</strong> verw<strong>en</strong><strong>de</strong>n.<br />

Schirmung sorgfältig auf PE leg<strong>en</strong>.<br />

Motor− und Netz−Schutzleiter an getr<strong>en</strong>nte PE−Klemm<strong>en</strong> schraub<strong>en</strong>.<br />

Schirmauflage:<br />

1. Leitung vorbereit<strong>en</strong><br />

A<br />

B<br />

C<br />

X1<br />

X2<br />

F<br />

G<br />

2. Leitung durch Öse<br />

<strong>de</strong>s Schirmblechs<br />

führ<strong>en</strong> und Öse umbieg<strong>en</strong>.<br />

D<br />

E<br />

H<br />

3. Öse mit Schirmblech<br />

verschraub<strong>en</strong>.<br />

Die Abschirmung<br />

muß fest mit <strong>de</strong>m<br />

Schirmblech verbun<strong>de</strong>n<br />

sein.<br />

0.7 Nm<br />

6 lb-in<br />

Abb. 9<br />

<strong>82</strong>00mot101<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

X2<br />

PES<br />

30<br />

Netzleitung L1, L2, L3, PE<br />

PE−Anschluß Netzleitung<br />

PE−Anschluß Motor<br />

Geschirmte Steuerleitung<br />

Schirmauflage Steuerleitung (Schirm mit Schirmblech fest verschraub<strong>en</strong>)<br />

PE−Anschluß Klemm<strong>en</strong>leiste X2<br />

Pot<strong>en</strong>tial<strong>fr</strong>eie Klemme (z. B. Sternpunkt bei Sternschaltung <strong>de</strong>s Motors)<br />

Funktionsmodul<br />

Klemm<strong>en</strong>leiste Netzanschluß<br />

Klemm<strong>en</strong>leiste Motoranschluß<br />

HF−Schirmabschluß durch großflächige Anbindung an PE<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Elektrische Installation<br />

Netzanschluß / Bremswi<strong>de</strong>rstand<br />

4<br />

Stop!<br />

Der Ableitstrom geg<strong>en</strong> Er<strong>de</strong> (PE) ist > 3,5 mA. Nach EN 50178 ist<br />

eine Festinstallation erfor<strong>de</strong>rlich. Der PE−Anschluß muß nach<br />

EN 50178 ausgeführt sein.<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

5.5 mm<br />

PE<br />

L3 L2 L1 BR2 BR1 BR0 K14 K12 K11<br />

2.5 mm 2<br />

AWG 12<br />

6 mm<br />

K14 K12 K11<br />

33<br />

Abb. 10<br />

A<br />

BR2 BR1 BR0<br />

R B<br />

1a<br />

3.4 Nm<br />

30 lb-in<br />

3/PE AC 320...550V 45...65Hz<br />

L1<br />

L2<br />

L3<br />

PE<br />

F1<br />

K1<br />

<strong>82</strong>00mot009<br />

X1<br />

L3 L2<br />

L1<br />

<br />

R B = Bremswi<strong>de</strong>rstand (Zubehör)<br />

R B 450 (E<strong>82</strong>MV551/E<strong>82</strong>MV751)<br />

R B 200 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 31


4<br />

Elektrische Installation<br />

Netzanschluß / Bremswi<strong>de</strong>rstand<br />

Sicherung<strong>en</strong> und Leitungsquerschnitte<br />

Typ Netz Installation nach EN 60204−1 Installation nach UL 1) FI 2)<br />

L1, L2, L3, PE<br />

[mm 2 ]<br />

Schmelzsicherung<br />

Sicherungsautomat<br />

Schmelzsicherung<br />

L1, L2, L3, PE<br />

[AWG]<br />

E<strong>82</strong>MV551_4B<br />

M6 A B6 A 1 5 A 18<br />

E<strong>82</strong>MV751_4B 3/PE AC M6 A B6 A 1 5 A 18<br />

320 ... 550 V;<br />

E<strong>82</strong>MV152_4B M6 A B6 A 1 5 A 18<br />

45 ... 65 Hz<br />

E<strong>82</strong>MV222_4B M10 A B10 A 1.5 10 A 16<br />

1) Nur UL−approbierte Leitung<strong>en</strong>, Sicherung<strong>en</strong> und Sicherungshalter verw<strong>en</strong><strong>de</strong>n.<br />

UL−Sicherung: Spannung 500 ... 600 V, Auslösecharakteristik "H", "K5" o<strong>de</strong>r "CC"<br />

2) Pulsstroms<strong>en</strong>sitiver o<strong>de</strong>r allstroms<strong>en</strong>sitiver Fehlerstrom−Schutzschalter<br />

Nationale und regionale Vorschrift<strong>en</strong> beacht<strong>en</strong><br />

Beacht<strong>en</strong> Sie bei Einsatz von Fehlerstrom−Schutzschaltern:<br />

Fehlerstrom−Schutzschalter nur zwisch<strong>en</strong> speis<strong>en</strong><strong>de</strong>m Netz und<br />

Antriebsregler installier<strong>en</strong>.<br />

Fehlerstrom−Schutzschalter kann falsch auslös<strong>en</strong> durch<br />

– kapazitive Ausgleichsströme <strong>de</strong>r Leitungsschirme währ<strong>en</strong>d <strong>de</strong>s<br />

Betriebs (vor allem bei lang<strong>en</strong>, geschirmt<strong>en</strong> Motorleitung<strong>en</strong>),<br />

– gleichzeitiges Zuschalt<strong>en</strong> mehrerer Antriebsregler ans Netz.<br />

<strong>82</strong>00 <strong>motec</strong> in Parallelschaltung<br />

30 mA<br />

Erfor<strong>de</strong>rliches Netzschütz bei Anschluß von:<br />

Typ Netzstrom 1 <strong>motec</strong> 2 <strong>motec</strong> 3 <strong>motec</strong> 4 <strong>motec</strong> 5 <strong>motec</strong> 6 <strong>motec</strong><br />

E<strong>82</strong>MV551_4B 1.8 A<br />

E<strong>82</strong>MV751_4B 2.4 A 4 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1)<br />

E<strong>82</strong>MV152_4B 3.8 A 4 <strong>kW</strong> 2) 5.5 <strong>kW</strong> 2) 7.5 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2)<br />

E<strong>82</strong>MV222_4B 5.5 A<br />

Die Summe <strong>de</strong>r Netzströme darf max. 24 A betrag<strong>en</strong>!<br />

WICHTIG<br />

1) Netzschütz bestimmt durch <strong>de</strong>n Einschaltstrom.<br />

2) Netzschütz bei Betrieb mit Netzdrossel 1.5 mH/24 A (Best.−Nr. ELN3−0150H024) o<strong>de</strong>r<br />

Strombegr<strong>en</strong>zungsmodul E<strong>82</strong>ZJ004 (max. 20 A/Phase).<br />

Nationale und regionale Vorschrift<strong>en</strong> beacht<strong>en</strong><br />

32<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Elektrische Installation<br />

Anschluß Relaisausgang<br />

4<br />

<strong>82</strong>00 <strong>motec</strong><br />

X1<br />

K14 K12 K11 X1<br />

Abb. 11<br />

PES<br />

1a<br />

PES<br />

<strong>82</strong>00mot148<br />

Funktion<br />

Relaisstellung<br />

geschaltet<br />

Meldung<br />

(L<strong>en</strong>ze−Einstellung)<br />

X1/K11 Relaisausgang Öffner geöffnet TRIP<br />

X1/K12 Relais−Mittelkontakt<br />

X1/K14 Relaisausgang Schließer geschloss<strong>en</strong> TRIP<br />

PES HF−Schirmabschluß durch großflächige Anbindung an PE<br />

Technische Dat<strong>en</strong><br />

AC 250 V/3 A<br />

DC 24 V/2 A ... DC 240 V/0.22 A<br />

Hinweis!<br />

Für das Schalt<strong>en</strong> von Steuersignal<strong>en</strong> geschirmte Leitung<strong>en</strong><br />

verw<strong>en</strong><strong>de</strong>n und HF−Schirmabschluß durch PE−Anbindung<br />

herstell<strong>en</strong>.<br />

Für das Schalt<strong>en</strong> von Netzpot<strong>en</strong>tial<strong>en</strong> sind ungeschirmte<br />

Leitung<strong>en</strong> ausreich<strong>en</strong>d.<br />

Zum Schutz <strong>de</strong>r Relaiskontakte ist bei induktiver o<strong>de</strong>r<br />

kapazitver Last eine <strong>en</strong>tsprech<strong>en</strong><strong>de</strong> Schutzbeschaltung<br />

unbedingt notw<strong>en</strong>dig!<br />

Die Leb<strong>en</strong>sdauer <strong>de</strong>s Relais ist abhängig von <strong>de</strong>r Art <strong>de</strong>r<br />

Belastung (ohmsch, induktiv o<strong>de</strong>r kapazitiv) und <strong>de</strong>m Wert<br />

<strong>de</strong>r Schaltleistung.<br />

Die ausgegeb<strong>en</strong>e Meldung könn<strong>en</strong> Sie in <strong>de</strong>n Co<strong>de</strong>stell<strong>en</strong><br />

C0008 o<strong>de</strong>r C0415/1 än<strong>de</strong>rn.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 33


5<br />

Montage Funktionsmodul (Option)<br />

Stop!<br />

Steuerleitung<strong>en</strong> immer abschirm<strong>en</strong>, um Störeinkopplung<strong>en</strong> zu<br />

vermei<strong>de</strong>n!<br />

Die FIF−Ab<strong>de</strong>ckkappe am Elektronikmodul und die<br />

Schutzkappe <strong>de</strong>s Funktionsmoduls <strong>en</strong>tfern<strong>en</strong>. Sonst könn<strong>en</strong><br />

<strong>de</strong>r <strong>motec</strong> o<strong>de</strong>r das Funktionsmodul beschädigt wer<strong>de</strong>n.<br />

1<br />

klick<br />

2<br />

<br />

1a<br />

X3<br />

3<br />

<br />

4<br />

1a<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X3<br />

PES<br />

PES<br />

2<br />

1 mm<br />

AWG 18<br />

6mm<br />

<strong>82</strong>00mot147<br />

1b<br />

1. Funktionsmodul in die Halterung steck<strong>en</strong>.<br />

2. Schutzkappe <strong>de</strong>s Funktionsmoduls <strong>en</strong>tfern<strong>en</strong> und aufbewahr<strong>en</strong>.<br />

3. FIF−Ab<strong>de</strong>ckkappe <strong>en</strong>tfern<strong>en</strong> und aufbewahr<strong>en</strong>!<br />

4. Verdrahtung: siehe Montageanleitung <strong>de</strong>s Funktionsmoduls.<br />

34<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


<strong>motec</strong> zusamm<strong>en</strong>bau<strong>en</strong> 6<br />

<strong>motec</strong> mit Funktionsmodul<br />

Stop!<br />

Vor <strong>de</strong>m Zusamm<strong>en</strong>bau unbedingt Schutzkappe <strong>de</strong>s<br />

Funktionsmoduls und FIF−Ab<strong>de</strong>ckkappe <strong>en</strong>tfern<strong>en</strong> und<br />

aufbewahr<strong>en</strong>! Sonst kann <strong>de</strong>r <strong>motec</strong> beschädigt wer<strong>de</strong>n!<br />

Vor Inbetriebnahme mit <strong>de</strong>m Aufkleber , <strong>de</strong>r <strong>de</strong>m<br />

Funktionsmodul beiliegt, das <strong>motec</strong>−Typ<strong>en</strong>schild<br />

vervollständig<strong>en</strong>.<br />

<br />

<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

Standard-I/O<br />

S<br />

<strong>82</strong>00mot059<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 35


6<br />

<strong>motec</strong> zusamm<strong>en</strong>bau<strong>en</strong><br />

<strong>motec</strong> ohne Funktionsmodul<br />

Stop!<br />

FIF−Ab<strong>de</strong>ckkappe muß aufgesteckt sein. Der <strong>motec</strong> ist nur so<br />

funktionsfähig!<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

<strong>82</strong>00mot138<br />

36<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Vor <strong>de</strong>m erst<strong>en</strong> Einschalt<strong>en</strong><br />

7<br />

Hinweis!<br />

Halt<strong>en</strong> Sie die jeweilige Einschaltreih<strong>en</strong>folge ein.<br />

Bei Störung<strong>en</strong> währ<strong>en</strong>d <strong>de</strong>r Inbetriebnahme hilft Ihn<strong>en</strong> das<br />

Kapitel "Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong>".<br />

Um Person<strong>en</strong>schä<strong>de</strong>n o<strong>de</strong>r Sachschä<strong>de</strong>n zu vermei<strong>de</strong>n, überprüf<strong>en</strong><br />

Sie ...<br />

... vor <strong>de</strong>m Zuschalt<strong>en</strong> <strong>de</strong>r Netzspannung:<br />

Die Verdrahtung auf Vollständigkeit, Kurzschluß und Erdschluß<br />

Die Funktion "NOT−AUS" <strong>de</strong>r Gesamtanlage<br />

Die Schaltungsart <strong>de</strong>s Motors (Stern/Dreieck) muß an die<br />

Ausgangsspannung <strong>de</strong>s Antriebsreglers angepaßt sein.<br />

W<strong>en</strong>n kein Funktionsmodul verw<strong>en</strong><strong>de</strong>t wird, muß die<br />

FIF−Ab<strong>de</strong>ckkappe aufgesteckt sein (Lieferzustand).<br />

W<strong>en</strong>n die interne Spannungsquelle X3/20 z. B. <strong>de</strong>s Standard−I/O<br />

verw<strong>en</strong><strong>de</strong>t wird, müss<strong>en</strong> die Klemm<strong>en</strong> X3/7 und X3/39 gebrückt sein.<br />

... vor <strong>de</strong>r Regler<strong>fr</strong>eigabe die Einstellung <strong>de</strong>r wichtigst<strong>en</strong> Antriebsparameter:<br />

Sind die für Ihre Anw<strong>en</strong>dung relevant<strong>en</strong> Antriebsparameter richtig<br />

eingestellt?<br />

– Z. B. die Konfiguration <strong>de</strong>r analog<strong>en</strong> und digital<strong>en</strong> Eingänge und<br />

Ausgänge<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 37


7 Inbetriebnahme<br />

Wahl <strong>de</strong>r richtig<strong>en</strong> Betriebsart<br />

Über die Betriebsart wähl<strong>en</strong> Sie die Steuerungsart o<strong>de</strong>r Regelungsart <strong>de</strong>s<br />

Antriebsreglers aus. Sie könn<strong>en</strong> wähl<strong>en</strong> zwisch<strong>en</strong><br />

U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

Vectorregelung<br />

S<strong>en</strong>sorlose Drehmom<strong>en</strong>tregelung<br />

Wahl <strong>de</strong>r richtig<strong>en</strong> Betriebsart<br />

Die U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung ist die klassische Betriebsart für Standardanw<strong>en</strong>dung<strong>en</strong>.<br />

Mit <strong>de</strong>r Vector−Regelung erziel<strong>en</strong> Sie geg<strong>en</strong>über <strong>de</strong>r U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

verbesserte Antriebseig<strong>en</strong>schaft<strong>en</strong> durch:<br />

höheres Drehmom<strong>en</strong>t über <strong>de</strong>n gesamt<strong>en</strong> Drehzahlbereich<br />

höhere Drehzahlg<strong>en</strong>auigkeit und höhere Rundlaufgüte<br />

höher<strong>en</strong> Wirkungsgrad<br />

M<br />

<br />

<br />

M N<br />

n N<br />

n<br />

<br />

<br />

U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

Vector−Regelung<br />

<strong>82</strong>00vec524<br />

Empfohl<strong>en</strong>e Betriebsart<strong>en</strong> für Standardanw<strong>en</strong>dung<strong>en</strong><br />

Für Standardanw<strong>en</strong>dung<strong>en</strong> hilft Ihn<strong>en</strong> die folg<strong>en</strong><strong>de</strong> Tabelle, die richtige<br />

Betriebsart zu wähl<strong>en</strong>:<br />

38<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Wahl <strong>de</strong>r richtig<strong>en</strong> Betriebsart<br />

7<br />

Anw<strong>en</strong>dung<br />

Einzelantriebe<br />

Betriebsart<br />

Einstellung in C0014<br />

empfohl<strong>en</strong><br />

alternativ<br />

mit stark wechseln<strong>de</strong>n Last<strong>en</strong> 4 2<br />

mit Schweranlauf 4 2<br />

mit Drehzahlregelung (Drehzahlrückführung) 2 4<br />

mit hoher Dynamik (z. B. Positionier− und Zustellantriebe) 2 −<br />

mit Drehmom<strong>en</strong>t−Sollwert 5 −<br />

mit Drehmom<strong>en</strong>tbegr<strong>en</strong>zung (Leistungsregelung) 2 4<br />

Drehstrom−Reluktanzmotor<strong>en</strong> 2 −<br />

Drehstrom−Verschiebeankermotor<strong>en</strong> 2 −<br />

Drehstrommotor<strong>en</strong> mit fest zugeordneter Frequ<strong>en</strong>z−Spannungsk<strong>en</strong>nlinie 2 −<br />

Pump<strong>en</strong>− und Lüfterantriebe mit quadratischer Lastk<strong>en</strong>nlinie 3 2 o<strong>de</strong>r 4<br />

Grupp<strong>en</strong>antriebe<br />

(mehrere Motor<strong>en</strong> an einem Antriebsregler angeschloss<strong>en</strong>)<br />

gleiche Motor<strong>en</strong> und gleiche Last<strong>en</strong> 2 −<br />

unterschiedliche Motor<strong>en</strong> und/o<strong>de</strong>r wechseln<strong>de</strong> Last<strong>en</strong> 2 −<br />

C0014 = 2: lineare U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

C0014 = 3: quadratische U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

C0014 = 4: Vector−Regelung<br />

C0014 = 5: s<strong>en</strong>sorlose Drehmom<strong>en</strong>t−Regelung<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 39


7 Inbetriebnahme<br />

Parametrierung mit <strong>de</strong>m Handterminal E<strong>82</strong>ZBB<br />

Beschreibung<br />

Das Handterminal ist als Zubehör erhältlich. Das Handterminal besteht aus<br />

einer Gummi−Ummantelung in <strong>de</strong>r das Keypad E<strong>82</strong>ZBC montiert ist. Für <strong>de</strong>n<br />

Anschluß an <strong>de</strong>n Antriebsregler b<strong>en</strong>ötig<strong>en</strong> Sie eine separate Anschlußleitung<br />

Typ E<strong>82</strong>ZWL. Die vollständige Beschreibung <strong>de</strong>s Keypad fin<strong>de</strong>n Sie in<br />

<strong>de</strong>r Anleitung, die mit <strong>de</strong>m Keypad geliefert wird.<br />

Handterminal anschließ<strong>en</strong><br />

Sie könn<strong>en</strong> das Handterminal auch währ<strong>en</strong>d <strong>de</strong>s Betriebs mit <strong>de</strong>r Schnittstelle<br />

AIF <strong>de</strong>s Antriebsreglers verbin<strong>de</strong>n und wie<strong>de</strong>r davon tr<strong>en</strong>n<strong>en</strong>.<br />

Sobald das Keypad mit Spannung versorgt wird, führt es ein<strong>en</strong> Selbsttest<br />

aus. Das Keypad ist betriebsbereit, w<strong>en</strong>n es sich im Anzeigemodus befin<strong>de</strong>t.<br />

40<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Lineare U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

Die folg<strong>en</strong><strong>de</strong> Beschreibung gilt für <strong>de</strong>n Antriebsregler mit Funktionsmodul<br />

Standard−I/O und leistungszugeordnetem Drehstrom−Asynchronmotor.<br />

7<br />

1. Schliess<strong>en</strong> Sie das Keypad an<br />

2. Stell<strong>en</strong> Sie sicher, daß nach<br />

Netz−Einschalt<strong>en</strong> die Reglersperre<br />

aktiv ist<br />

3. Schalt<strong>en</strong> Sie das Netz ein<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Klemme X3/28 = LOW<br />

4. Nach ca. 2 s befin<strong>de</strong>t sich das<br />

Keypad im Anzeigemodus Disp"<br />

und zeigt die Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

<br />

PS 1<br />

<br />

(C0050) an<br />

000 000<br />

<br />

Hi<br />

Hz<br />

Lo<br />

0050<br />

misc002<br />

Das M<strong>en</strong>ü USEr ist aktiv<br />

5. Wechseln Sie in <strong>de</strong>n Modus , <br />

<br />

<br />

<br />

damit Sie die Grun<strong>de</strong>instellung<strong>en</strong><br />

<br />

für Ihr<strong>en</strong> Antrieb ausführ<strong>en</strong> könn<strong>en</strong><br />

000 000<br />

PS<br />

1 Im Display blinkt 0050<br />

<br />

0050<br />

Hi<br />

Hz<br />

Lo<br />

6. Pass<strong>en</strong> Sie Spannungsbereich/<br />

Strombereich für die analoge<br />

Sollwertvorgabe an (C0034)<br />

L<strong>en</strong>ze−Einstellung: −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

7. Pass<strong>en</strong> Sie die Klemm<strong>en</strong>konfiguration<br />

an die Verdrahtung an<br />

(C0007)<br />

L<strong>en</strong>ze−Einstellung: −0−, d. h.<br />

E1: JOG1/3 Auswahl Festsollwerte<br />

E2: JOG2/3<br />

E3: DCB Gleichstrombremse<br />

E4: CW/CCW Rechtslauf/Linkslauf<br />

8. Stell<strong>en</strong> Sie die minimale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

ein (C0010)<br />

L<strong>en</strong>ze−Einstellung: 0.00 Hz<br />

<br />

<br />

<br />

<br />

<br />

<br />

[f]<br />

C0011<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

DIP−Schalter auf <strong>de</strong>m<br />

Standard−I/O auf <strong>de</strong>n<br />

gleich<strong>en</strong> Bereich einstell<strong>en</strong><br />

(siehe Montageanleitung<br />

<strong>de</strong>s Standard−I/O)<br />

9. Stell<strong>en</strong> Sie die maximale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

ein (C0011)<br />

L<strong>en</strong>ze−Einstellung: 50.00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 41


7 Inbetriebnahme<br />

Lineare U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

10. Stell<strong>en</strong> Sie die Hochlaufzeit T ir<br />

ein (C0012)<br />

L<strong>en</strong>ze−Einstellung: 5.00 s<br />

11. Stell<strong>en</strong> Sie die Ablaufzeit T if ein<br />

(C0013)<br />

L<strong>en</strong>ze−Einstellung: 5.00 s<br />

12. Stell<strong>en</strong> Sie die U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z<br />

ein (C0015)<br />

L<strong>en</strong>ze−Einstellung: 50.00 Hz<br />

13. Stell<strong>en</strong> Sie die U min −Anhebung<br />

ein (C0016)<br />

L<strong>en</strong>ze−Einstellung: hängt ab vom<br />

Antriebsreglertyp<br />

14. W<strong>en</strong>n Sie weitere Einstellung<strong>en</strong><br />

vornehm<strong>en</strong> woll<strong>en</strong>, müss<strong>en</strong> Sie<br />

in das M<strong>en</strong>ü ALL wechseln<br />

15. Wechseln Sie in das M<strong>en</strong>ü ALL<br />

A Prüf<strong>en</strong> Sie die Einstellung für<br />

die Lüfterüberwachung in <strong>de</strong>r<br />

Co<strong>de</strong>stelle C0608:<br />

– für <strong>82</strong>00 <strong>motec</strong> 0.25...0.37<br />

<strong>kW</strong> u. <strong>0.55</strong>...<strong>2.2</strong> <strong>kW</strong>:<br />

C0608 = 0 ! (Werkseinstellung)<br />

– für <strong>82</strong>00 <strong>motec</strong> 3...7.5 <strong>kW</strong>:<br />

C0608 =1 o<strong>de</strong>r C0608 = 2!<br />

Stop!<br />

Funktion unbedingt bei<br />

<strong>de</strong>r Inbetriebnahme aktivier<strong>en</strong>!<br />

Der Antriebsregler<br />

kann sonst durch<br />

Überhitzung zerstört<br />

wer<strong>de</strong>n!<br />

– alle an<strong>de</strong>r<strong>en</strong> Antriebsregler:<br />

B0 <br />

+ <br />

B<br />

B <br />

<br />

U out<br />

100%<br />

U min<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

0<br />

0 C0015<br />

Z. B. Fest<strong>fr</strong>equ<strong>en</strong>z<strong>en</strong> (JOG) (C0037,<br />

C0038, C0039) o<strong>de</strong>r Motortemperatur−Überwachung<br />

(C0119) aktivier<strong>en</strong><br />

f<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = gewünschte Hochlaufzeit<br />

T if<br />

Н Н t if<br />

C0011<br />

f 2<br />

f 1<br />

t if = gewünschte Ablaufzeit<br />

Die L<strong>en</strong>ze−Einstellung ist<br />

für alle gängig<strong>en</strong> Anw<strong>en</strong>dung<strong>en</strong><br />

geeignet<br />

C0608 = 0 ! (Werkseinstellung)<br />

B Stell<strong>en</strong> Sie ggf. weitere Funktion<strong>en</strong><br />

über Co<strong>de</strong>stell<strong>en</strong> ein.<br />

W<strong>en</strong>n Sie alle Einstellung<strong>en</strong> abgeschloss<strong>en</strong> hab<strong>en</strong>:<br />

16. Sollwert vorgeb<strong>en</strong> Z. B. über Pot<strong>en</strong>tiometer an <strong>de</strong>n<br />

Klemm<strong>en</strong> 7, 8, 9<br />

17. Regler <strong>fr</strong>eigeb<strong>en</strong><br />

X3<br />

Klemme X3/28 = HIGH<br />

20 28 misc002<br />

18. Der Antrieb läuft jetzt. W<strong>en</strong>n <strong>de</strong>r Antrieb nicht<br />

anläuft, zusätzlich <br />

drück<strong>en</strong><br />

42<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Vector−Regelung<br />

Die folg<strong>en</strong><strong>de</strong> Beschreibung gilt für <strong>de</strong>n Antriebsregler mit Funktionsmodul<br />

Standard−I/O und leistungszugeordnetem Drehstrom−Asynchronmotor.<br />

7<br />

1. Schliess<strong>en</strong> Sie das Keypad an<br />

2. Stell<strong>en</strong> Sie sicher, daß nach<br />

Netz−Einschalt<strong>en</strong> die Reglersperre<br />

aktiv ist<br />

3. Schalt<strong>en</strong> Sie das Netz ein<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Klemme X3/28 = LOW<br />

4. Nach ca. 2 s befin<strong>de</strong>t sich das<br />

Keypad im Anzeigemodus Disp"<br />

und zeigt die Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

<br />

PS 1<br />

<br />

(C0050) an<br />

000 000<br />

<br />

Hi<br />

Hz<br />

Lo<br />

0050<br />

misc002<br />

Das M<strong>en</strong>ü USEr ist aktiv<br />

5. Wechseln Sie in das M<strong>en</strong>ü ALL<br />

6. Wechseln Sie in <strong>de</strong>n Modus , <br />

<br />

<br />

<br />

<br />

damit Sie die Grun<strong>de</strong>instellung<strong>en</strong><br />

<br />

für Ihr<strong>en</strong> Antrieb ausführ<strong>en</strong> könn<strong>en</strong><br />

000 000<br />

PS 1 Im Display blinkt 0050<br />

<br />

0050<br />

Hi<br />

Hz<br />

Lo<br />

7. Pass<strong>en</strong> Sie die Klemm<strong>en</strong>konfiguration<br />

an die Verdrahtung an<br />

(C0007)<br />

L<strong>en</strong>ze−Einstellung: −0−, d. h.<br />

E1: JOG1/3 Auswahl Festsollwerte<br />

E2: JOG2/3<br />

E3: DCB Gleichstrombremse<br />

E4: CW/CCW Rechtslauf/Linkslauf<br />

8. Stell<strong>en</strong> Sie die minimale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

ein (C0010)<br />

L<strong>en</strong>ze−Einstellung: 0.00 Hz<br />

<br />

<br />

<br />

[f]<br />

C0011<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

9. Stell<strong>en</strong> Sie die maximale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

ein (C0011)<br />

L<strong>en</strong>ze−Einstellung: 50.00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

10. Stell<strong>en</strong> Sie die Hochlaufzeit T ir<br />

ein (C0012)<br />

L<strong>en</strong>ze−Einstellung: 5.00 s<br />

11. Stell<strong>en</strong> Sie die Ablaufzeit T if ein<br />

(C0013)<br />

L<strong>en</strong>ze−Einstellung: 5.00 s<br />

B0 <br />

+ <br />

B<br />

B <br />

<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = gewünschte Hochlaufzeit<br />

T if<br />

Н Н t if<br />

C0011<br />

f 2<br />

f 1<br />

t if = gewünschte Ablaufzeit<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 43


7 Inbetriebnahme<br />

Vector−Regelung<br />

12. Stell<strong>en</strong> Sie die Betriebsart "Vector−Regelung"<br />

ein (C0014 = 4)<br />

L<strong>en</strong>ze−Einstellung: lineare<br />

U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung (C0014<br />

= 2)<br />

13. Pass<strong>en</strong> Sie Spannungsbereich/<br />

Strombereich für die analoge<br />

Sollwertvorgabe an (C0034)<br />

L<strong>en</strong>ze−Einstellung: −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

<br />

<br />

<br />

<br />

SHPRG M<strong>en</strong>u<br />

Co<strong>de</strong><br />

001400<br />

Para<br />

Vector-Ctrl<br />

4<br />

9371BC008<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

DIP−Schalter auf <strong>de</strong>m<br />

Standard−I/O auf <strong>de</strong>n<br />

gleich<strong>en</strong> Bereich einstell<strong>en</strong><br />

(siehe Montageanleitung<br />

<strong>de</strong>s Standard−I/O)<br />

14. Geb<strong>en</strong> Sie die Motordat<strong>en</strong> ein Siehe Motor−Typ<strong>en</strong>schild<br />

A Motor−Bemessungsdrehzahl<br />

(C0087)<br />

L<strong>en</strong>ze−Einstellung: 1390 rpm<br />

B Motor−Bemessungsstrom<br />

(C0088)<br />

L<strong>en</strong>ze−Einstellung: geräteabhängig<br />

Wert für die gewählte<br />

Motor−Schaltungsart<br />

(Stern/Dreieck) eintrag<strong>en</strong>!<br />

C Motor−Bemessungs<strong>fr</strong>equ<strong>en</strong>z<br />

(C0089)<br />

L<strong>en</strong>ze−Einstellung: 50 Hz<br />

D<br />

E<br />

Motor−Bemessungsspannung<br />

(C0090)<br />

L<strong>en</strong>ze−Einstellung: geräteabhängig<br />

Motor−cos (C0091)<br />

L<strong>en</strong>ze−Einstellung: geräteabhängig<br />

Wert für die gewählte<br />

Motor−Schaltungsart<br />

(Stern/Dreieck) eintrag<strong>en</strong>!<br />

44<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


15. Start<strong>en</strong> Sie die Motorparameter−<br />

I<strong>de</strong>ntifizierung (C0148)<br />

A Sicherstell<strong>en</strong>, daß <strong>de</strong>r Regler<br />

gesperrt ist<br />

<br />

B C0148 = 1 einstell<strong>en</strong> drück<strong>en</strong><br />

C<br />

D<br />

Regler <strong>fr</strong>eigeb<strong>en</strong><br />

W<strong>en</strong>n nach ca. 30 s das Segm<strong>en</strong>t<br />

wie<strong>de</strong>r aktiv ist, Regler<br />

wie<strong>de</strong>r sperr<strong>en</strong>.<br />

Inbetriebnahme<br />

Vector−Regelung<br />

X3<br />

20 28<br />

misc001<br />

7<br />

Nur bei kaltem Motor<br />

durchführ<strong>en</strong>!<br />

Klemme X3/28 = LOW<br />

X3 Klemme X3/28 =<br />

20 28 misc002 HIGH<br />

Die I<strong>de</strong>ntifizierung<br />

startet:<br />

– Das Segm<strong>en</strong>t <br />

erlischt<br />

– Der Motor wird bestromt<br />

und pfeift"<br />

leise.<br />

– Der Motor dreht<br />

sich nicht!<br />

X3<br />

Klemme X3/28 =<br />

20 28<br />

misc001<br />

LOW<br />

Die I<strong>de</strong>ntifizierung ist<br />

be<strong>en</strong><strong>de</strong>t.<br />

Berechnet und gespeichert<br />

wur<strong>de</strong>n:<br />

– U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z<br />

(C0015)<br />

– Schlupfkomp<strong>en</strong>sation<br />

(C0021)<br />

– Motor−Stän<strong>de</strong>rinduktivität<br />

(C0092)<br />

Gemess<strong>en</strong> und gespeichert<br />

wur<strong>de</strong>:<br />

– Motor−Stän<strong>de</strong>rwi<strong>de</strong>rstand<br />

(C0084) =<br />

Gesamtwi<strong>de</strong>rstand<br />

von Motorleitung<br />

und Motor<br />

<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 45


7 Inbetriebnahme<br />

Vector−Regelung<br />

16. Stell<strong>en</strong> Sie ggf. weitere Parameter<br />

ein<br />

17. Wechseln Sie in das M<strong>en</strong>ü ALL<br />

A Prüf<strong>en</strong> Sie die Einstellung für<br />

die Lüfterüberwachung in <strong>de</strong>r<br />

Co<strong>de</strong>stelle C0608:<br />

– für <strong>82</strong>00 <strong>motec</strong> 0.25...0.37<br />

<strong>kW</strong> u. <strong>0.55</strong>...<strong>2.2</strong> <strong>kW</strong>:<br />

C0608 = 0 ! (Werkseinstellung)<br />

– für <strong>82</strong>00 <strong>motec</strong> 3...7.5 <strong>kW</strong>:<br />

C0608 =1 o<strong>de</strong>r C0608 = 2!<br />

Stop!<br />

Funktion unbedingt bei<br />

<strong>de</strong>r Inbetriebnahme aktivier<strong>en</strong>!<br />

Der Antriebsregler<br />

kann sonst durch<br />

Überhitzung zerstört<br />

wer<strong>de</strong>n!<br />

– alle an<strong>de</strong>r<strong>en</strong> Antriebsregler:<br />

Z. B. Fest<strong>fr</strong>equ<strong>en</strong>z<strong>en</strong> (JOG) (C0037,<br />

C0038, C0039 o<strong>de</strong>r Motortemperatur−Überwachung<br />

aktivier<strong>en</strong> (C0119)<br />

C0608 = 0 ! (Werkseinstellung)<br />

B Stell<strong>en</strong> Sie ggf. weitere Funktion<strong>en</strong><br />

über Co<strong>de</strong>stell<strong>en</strong> ein.<br />

W<strong>en</strong>n Sie alle Einstellung<strong>en</strong> abgeschloss<strong>en</strong> hab<strong>en</strong>:<br />

18. Sollwert vorgeb<strong>en</strong> Z. B. über Pot<strong>en</strong>tiometer an <strong>de</strong>n<br />

Klemm<strong>en</strong> 7, 8, 9<br />

19. Regler <strong>fr</strong>eigeb<strong>en</strong><br />

X3<br />

Klemme X3/28 = HIGH<br />

20 28 misc002<br />

20. Der Antrieb läuft jetzt. W<strong>en</strong>n <strong>de</strong>r Antrieb nicht<br />

anläuft, zusätzlich <br />

drück<strong>en</strong><br />

46<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Vector−Regelung<br />

Vectorregelung optimier<strong>en</strong><br />

Die Vectorregelung ist nach <strong>de</strong>r Motorparameter−I<strong>de</strong>ntifizierung in <strong>de</strong>r Regel<br />

ohne weitere Maßnahm<strong>en</strong> betriebsfähig. Sie müss<strong>en</strong> die Vectorregelung nur<br />

bei folg<strong>en</strong><strong>de</strong>m Antriebsverhalt<strong>en</strong> optimier<strong>en</strong>:−3−<br />

Antriebsverhalt<strong>en</strong><br />

Rauher Motorlauf und Motorstrom (C0054) > 60 %<br />

Motor−Bemessungsstrom im Maschin<strong>en</strong>leerlauf (stationärer<br />

Betrieb)<br />

Zu geringes Drehmom<strong>en</strong>t bei Frequ<strong>en</strong>z<strong>en</strong> f <<br />

5 Hz (Anlaufmom<strong>en</strong>t)<br />

Mangeln<strong>de</strong> Drehzahlkonstanz bei hoher Belastung<br />

(Sollwert und Motor−Drehzahl sind nicht mehr proportional)<br />

Fehlermeldung<strong>en</strong> OC1, OC3, OC4 o<strong>de</strong>r OC5 bei Hochlaufzeit<strong>en</strong><br />

(C0012) < 1 s (Antriebsregler kann <strong>de</strong>n dynamisch<strong>en</strong><br />

Vorgäng<strong>en</strong> nicht mehr folg<strong>en</strong>)<br />

7<br />

Abhilfe<br />

1. Motorinduktivität (C0092) um 10 % verringern<br />

2. Motorstrom in C0054 prüf<strong>en</strong><br />

3. Ist <strong>de</strong>r Motorstrom (C0054) > 50 % Motor−Bemessungsstrom:<br />

– C0092 weiter verringern, bis <strong>de</strong>r Motorstrom<br />

ca. 50 % <strong>de</strong>s Motor−Bemessungsstroms beträgt<br />

– C0092 max. um 20 % verringern!<br />

– Beacht<strong>en</strong> Sie: W<strong>en</strong>n Sie C0092 verringern,<br />

nimmt das Drehmom<strong>en</strong>t ab!<br />

Motorwi<strong>de</strong>rstand (C0084) vergrößern o<strong>de</strong>r Motorinduktivität<br />

(C0092) vergrößern<br />

Schlupfkomp<strong>en</strong>sation (C0021) vergrößern<br />

Überkomp<strong>en</strong>sation macht <strong>de</strong>n Antrieb instabil!<br />

Nachstellzeit <strong>de</strong>s I max −Reglers (C0078) verän<strong>de</strong>rn:<br />

C0078 verringern = I max −Regler wird schneller (dynamischer)<br />

C0078 vergrößern = I max −Regler wird langsamer<br />

("weicher")<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 47


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

Hinweis!<br />

Die folg<strong>en</strong><strong>de</strong> Tabelle beschreibt ausführlich die in <strong>de</strong>n<br />

Inbetriebnahme−Beispiel<strong>en</strong> g<strong>en</strong>annt<strong>en</strong> Co<strong>de</strong>s!<br />

Än<strong>de</strong>rn Sie keine Co<strong>de</strong>s, <strong>de</strong>r<strong>en</strong> Be<strong>de</strong>utung Sie nicht k<strong>en</strong>n<strong>en</strong>!<br />

Sie fin<strong>de</strong>n alle Co<strong>de</strong>s ausführlich beschrieb<strong>en</strong> im<br />

Systemhandbuch.<br />

So les<strong>en</strong> Sie die Co<strong>de</strong>tabelle<br />

Spalte Abkürzung Be<strong>de</strong>utung<br />

Co<strong>de</strong> Cxxxx Co<strong>de</strong> Cxxxx Parameterwert <strong>de</strong>s Co<strong>de</strong> kann in je<strong>de</strong>m<br />

1 Subco<strong>de</strong> 1 von Parametersatz unterschiedlich <strong>de</strong>finiert<br />

Cxxxx<br />

sein<br />

<br />

2 Subco<strong>de</strong> 2 von Parameterwert wird sofort übernomm<strong>en</strong><br />

Cxxxx<br />

(ONLINE)<br />

* Parameterwert <strong>de</strong>s Co<strong>de</strong> ist in all<strong>en</strong> Parametersätz<strong>en</strong> gleich<br />

Keypad E<strong>82</strong>ZBC Geän<strong>de</strong>rter Parameter <strong>de</strong>s Co<strong>de</strong> o<strong>de</strong>r Subco<strong>de</strong><br />

wird nach Drück<strong>en</strong> von übernomm<strong>en</strong><br />

Keypad XT<br />

EMZ9371BC<br />

Geän<strong>de</strong>rter Parameter <strong>de</strong>s Co<strong>de</strong> o<strong>de</strong>r Subco<strong>de</strong><br />

wird nach Drück<strong>en</strong> von übernomm<strong>en</strong><br />

Keypad E<strong>82</strong>ZBC Geän<strong>de</strong>rter Parameter <strong>de</strong>s Co<strong>de</strong> o<strong>de</strong>r Subco<strong>de</strong><br />

wird nach Drück<strong>en</strong> von übernomm<strong>en</strong>,<br />

w<strong>en</strong>n <strong>de</strong>r Regler gesperrt ist<br />

Keypad XT<br />

EMZ9371BC<br />

Geän<strong>de</strong>rter Parameter <strong>de</strong>s Co<strong>de</strong> o<strong>de</strong>r Subco<strong>de</strong><br />

wird nach Drück<strong>en</strong> von übernomm<strong>en</strong>,<br />

w<strong>en</strong>n <strong>de</strong>r Regler gesperrt ist<br />

(A)<br />

Co<strong>de</strong>, Subco<strong>de</strong> o<strong>de</strong>r Auswahl nur verfügbar bei Betrieb mit Application−I/O<br />

uSEr<br />

Co<strong>de</strong> ist in <strong>de</strong>r L<strong>en</strong>ze−Einstellung im USER−M<strong>en</strong>ü <strong>en</strong>thalt<strong>en</strong><br />

Bezeichnung<br />

Bezeichnung <strong>de</strong>s Co<strong>de</strong><br />

L<strong>en</strong>ze<br />

L<strong>en</strong>ze−Einstellung (Wert bei Auslieferung o<strong>de</strong>r nach Wie<strong>de</strong>rherstell<strong>en</strong><br />

<strong>de</strong>s Lieferzustands mit C0002)<br />

<br />

Die Spalte "WICHTIG" <strong>en</strong>thält weitere Information<br />

Auswahl 1 {%} 99 min. Wert {Einheit} max. Wert<br />

WICHTIG − Kurze, wichtige Erläuterung<strong>en</strong><br />

48<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

7<br />

Co<strong>de</strong> Einstellmöglichkeit<strong>en</strong> WICHTIG<br />

Nr. Bezeichnung L<strong>en</strong>ze Auswahl<br />

C0002 Parameter-<br />

0 0 Bereit PAR1 ... PAR4:<br />

*<br />

<br />

satzverwal-<br />

tung<br />

Parametersätze <strong>de</strong>s Antriebsreglers<br />

uSEr −4−<br />

PAR1 ... PAR4 <strong>en</strong>thalt<strong>en</strong><br />

auch die Parameter für die<br />

Funktionsmodule Standard−<br />

I/O, Application−I/O, AS−interface,<br />

Systembus (CAN)<br />

FPAR1:<br />

Modulspezifischer Parametersatz<br />

<strong>de</strong>r Feldbus−Funktionsmodule<br />

INTERBUS, PRO-<br />

FIBUS−DP, LECOM−B, DeviceNet/CANop<strong>en</strong><br />

FPAR1 wird im Funktionsmodul<br />

gespeichert<br />

C0002<br />

*<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

Lieferzustand<br />

wie<strong>de</strong>rherstell<strong>en</strong><br />

Parametersätze<br />

mit<br />

Keypad übertrag<strong>en</strong><br />

1 L<strong>en</strong>ze−Einstellung PAR1 Lieferzustand wie<strong>de</strong>rherstell<strong>en</strong><br />

2 L<strong>en</strong>ze−Einstellung PAR2<br />

im gewählt<strong>en</strong> Parametersatz<br />

3 L<strong>en</strong>ze−Einstellung PAR3<br />

4 L<strong>en</strong>ze−Einstellung PAR4<br />

31 L<strong>en</strong>ze−Einstellung FPAR1 Lieferzustand wie<strong>de</strong>rherstell<strong>en</strong><br />

im Feldbus−Funktionsmodul<br />

61 L<strong>en</strong>ze−Einstellung PAR1 +<br />

FPAR1<br />

62 L<strong>en</strong>ze−Einstellung PAR2 +<br />

FPAR1<br />

63 L<strong>en</strong>ze−Einstellung PAR3 +<br />

FPAR1<br />

64 L<strong>en</strong>ze−Einstellung PAR4 +<br />

FPAR1<br />

Keypad Antriebsregler<br />

70 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

10 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Lieferzustand wie<strong>de</strong>rherstell<strong>en</strong><br />

im gewählt<strong>en</strong> Parametersatz<br />

<strong>de</strong>s Antriebsreglers und im<br />

Feldbus−Funktionsmodul<br />

Mit <strong>de</strong>m Keypad könn<strong>en</strong> Sie<br />

die Parametersätze zu an<strong>de</strong>r<strong>en</strong><br />

Antriebsreglern übertrag<strong>en</strong>.<br />

Währ<strong>en</strong>d <strong>de</strong>r Übertragung ist<br />

<strong>de</strong>r Zugriff auf die Parameter<br />

über an<strong>de</strong>re Kanäle gesperrt!<br />

Alle verfügbar<strong>en</strong> Parametersätze<br />

(PAR1 ... PAR4, ggf.<br />

FPAR1) mit <strong>de</strong>n <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>n<br />

Dat<strong>en</strong> <strong>de</strong>s Keypad überschreib<strong>en</strong><br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 49


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

Co<strong>de</strong><br />

Nr.<br />

C0002<br />

*<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

Bezeichnung<br />

Parametersätze<br />

mit<br />

Keypad übertrag<strong>en</strong><br />

Einstellmöglichkeit<strong>en</strong><br />

L<strong>en</strong>ze<br />

Auswahl<br />

Keypad PAR1 (+ FPAR1)<br />

71 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

11 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Keypad PAR2 (+ FPAR1)<br />

72 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

12 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Keypad PAR3 (+ FPAR1)<br />

73 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

13 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Keypad PAR4 (+ FPAR1)<br />

74 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

14 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Antriebsregler Keypad<br />

80 mit Funktionsmodul Application−I/O,<br />

INTERBUS, PROFIBUS−DP, LECOM−<br />

B, DeviceNet/CANop<strong>en</strong><br />

20 mit all<strong>en</strong> an<strong>de</strong>r<strong>en</strong> Funktionsmodul<strong>en</strong><br />

Keypad Funktionsmodul<br />

40 nur mit Funktionsmodul INTERBUS,<br />

PROFIBUS−DP, LECOM−B, Device-<br />

Net/CANop<strong>en</strong><br />

Funktionsmodul Keypad<br />

50 nur mit Funktionsmodul INTERBUS,<br />

PROFIBUS−DP, LECOM−B, Device-<br />

Net/CANop<strong>en</strong><br />

WICHTIG<br />

Gewählt<strong>en</strong> Parametersatz und<br />

ggf. FPAR1 mit <strong>de</strong>n <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>n<br />

Dat<strong>en</strong> <strong>de</strong>s Keypad<br />

überschreib<strong>en</strong><br />

Alle verfügbar<strong>en</strong> Parametersätze<br />

(PAR1 ... PAR4, ggf.<br />

FPAR1) in das Keypad kopier<strong>en</strong><br />

Nur <strong>de</strong>n modulspezifisch<strong>en</strong> Parametersatz<br />

FPAR1 mit <strong>de</strong>n Dat<strong>en</strong><br />

<strong>de</strong>s Keypad überschreib<strong>en</strong><br />

Nur <strong>de</strong>n modulspezifisch<strong>en</strong> Parametersatz<br />

FPAR1 in das<br />

Keypad kopier<strong>en</strong><br />

50<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

7<br />

Co<strong>de</strong><br />

Nr.<br />

C0002<br />

*<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

C0002<br />

*<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

C0003<br />

*<br />

<br />

Bezeichnung<br />

eig<strong>en</strong>e<br />

Grun<strong>de</strong>instellung<br />

speichern<br />

eig<strong>en</strong>e<br />

Grun<strong>de</strong>instellung<br />

la<strong>de</strong>n/<br />

kopier<strong>en</strong><br />

Parameter<br />

nichtflüchtig<br />

speichern<br />

Einstellmöglichkeit<strong>en</strong><br />

WICHTIG<br />

L<strong>en</strong>ze Auswahl<br />

9 PAR1 eig<strong>en</strong>e Grun<strong>de</strong>instellung Sie könn<strong>en</strong> für die Parameter<br />

<strong>de</strong>s Antriebsreglers eine eig<strong>en</strong>e<br />

Grun<strong>de</strong>instellung speichern<br />

(z. B. <strong>de</strong>n Lieferzustand Ihrer<br />

Maschine):<br />

1. Sicherstell<strong>en</strong>, daß Parametersatz<br />

1 aktiv ist<br />

2. Regler sperr<strong>en</strong><br />

3. C0003 = 3 setz<strong>en</strong>, bestätig<strong>en</strong><br />

mit <br />

4. C0002 = 9 setz<strong>en</strong>, bestätig<strong>en</strong><br />

mit , die eig<strong>en</strong>e<br />

Grun<strong>de</strong>instellung ist gespeichert<br />

5. C0003 = 1 setz<strong>en</strong>, bestätig<strong>en</strong><br />

mit <br />

6. Regler <strong>fr</strong>eigeb<strong>en</strong><br />

Sie könn<strong>en</strong> mit dieser Funktion<br />

auch einfach PAR1 in die Parametersätze<br />

PAR2 ... PAR4 kopier<strong>en</strong><br />

5 eig<strong>en</strong>e Grun<strong>de</strong>instellung PAR1 Eig<strong>en</strong>e Grun<strong>de</strong>instellung wie<strong>de</strong>rherstell<strong>en</strong><br />

6 eig<strong>en</strong>e Grun<strong>de</strong>instellung PAR2<br />

im gewählt<strong>en</strong> Pa-<br />

rametersatz<br />

7 eig<strong>en</strong>e Grun<strong>de</strong>instellung PAR3<br />

8 eig<strong>en</strong>e Grun<strong>de</strong>instellung PAR4<br />

1 0 Parameter nicht im EEPROM speichern<br />

1 Parameter immer im EEPROM speichern<br />

3 eig<strong>en</strong>e Grun<strong>de</strong>instellung im<br />

EEPROM speichern<br />

Dat<strong>en</strong>verlust nach Netzausschalt<strong>en</strong><br />

Nach je<strong>de</strong>m Netzeinschalt<strong>en</strong><br />

aktiv<br />

Zyklisches Än<strong>de</strong>rn von Parametern<br />

über Busmodul ist<br />

nicht erlaubt<br />

Anschließ<strong>en</strong>d mit C0002 = 9<br />

Parametersatz 1 als eig<strong>en</strong>e<br />

Grun<strong>de</strong>instellung speichern<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 51


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

Co<strong>de</strong><br />

Nr.<br />

C0007<br />

<br />

uSEr<br />

C0007<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

Bezeichnung<br />

Feste Konfiguration<br />

digitale<br />

Eingänge<br />

Einstellmöglichkeit<strong>en</strong><br />

WICHTIG<br />

L<strong>en</strong>ze Auswahl<br />

Än<strong>de</strong>rung von C0007 wird in<br />

<strong>de</strong>n <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>n Subco<strong>de</strong><br />

von C0410 kopiert.<br />

Freie Konfiguration in C0410<br />

setzt C0007 = 255!<br />

0 E4 E3 E2 E1 CW/CCW = Rechtslauf/<br />

0 CW/ DCB JOG2/3 JOG1/3 Linkslauf<br />

CCW<br />

DCB = Gleichstrombremse<br />

1 CW/ PAR JOG2/3 JOG1/3 QSP = Quickstop<br />

CCW<br />

PAR = Parametersatz umschalt<strong>en</strong><br />

(PAR1 PAR2)<br />

2 CW/ QSP JOG2/3 JOG1/3<br />

CCW<br />

– PAR1 = LOW,<br />

3 CW/ PAR DCB JOG1/3<br />

PAR2 = HIGH<br />

CCW<br />

– Die Klemme muß in PAR1<br />

4 CW/ QSP PAR JOG1/3<br />

CCW<br />

und in PAR2 mit <strong>de</strong>r<br />

Funktion "PAR" belegt<br />

5 CW/ DCB TRIP− JOG1/3<br />

sein.<br />

CCW<br />

Set<br />

– Konfiguration<strong>en</strong> mit<br />

6 CW/ PAR TRIP− JOG1/3<br />

CCW<br />

Set<br />

"PAR" nur verw<strong>en</strong><strong>de</strong>n,<br />

w<strong>en</strong>n C0988 = 0<br />

7 CW/<br />

CCW<br />

8 CW/<br />

CCW<br />

9 CW/<br />

CCW<br />

10 CW/<br />

CCW<br />

11 CW/<br />

CCW<br />

12 CW/<br />

CCW<br />

13 CW/<br />

CCW<br />

14 CCW/<br />

QSP<br />

15 CCW/<br />

QSP<br />

16 CCW/<br />

QSP<br />

17 CCW/<br />

QSP<br />

18 CCW/<br />

QSP<br />

19 CCW/<br />

QSP<br />

PAR DCB TRIP−<br />

Set<br />

QSP PAR TRIP−<br />

Set<br />

QSP TRIP− JOG1/3<br />

Set<br />

TRIP− UP DOWN<br />

Set<br />

<br />

TRIP−Set = externer Fehler<br />

E4 E3<br />

DCB<br />

E2<br />

UP<br />

E1<br />

DOWN<br />

Auswahl Festsollwerte<br />

JOG1/3 JOG2/3<br />

PAR UP DOWN LOW LOW<br />

HIGH LOW<br />

QSP UP DOWN LOW HIGH<br />

HIGH HIGH<br />

CW/QSP DCB JOG1/3<br />

CW/QSP PAR JOG1/3<br />

CW/QSP JOG2/3 JOG1/3<br />

CW/QSP PAR DCB<br />

CW/QSP PAR TRIP−<br />

Set<br />

CW/QSP DCB TRIP−<br />

Set<br />

aktiv<br />

C0046<br />

JOG1<br />

JOG2<br />

JOG3<br />

52<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

7<br />

Co<strong>de</strong><br />

Nr.<br />

C0007<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

C0007<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

Bezeichnung<br />

Einstellmöglichkeit<strong>en</strong><br />

WICHTIG<br />

L<strong>en</strong>ze Auswahl<br />

E4 E3 E2 E1 UP/DOWN = Motorpoti−<br />

20 CCW/ CW/QSP TRIP− JOG1/3 Funktion<strong>en</strong><br />

QSP<br />

Set<br />

H/Re = Hand/Remote−Umschaltung<br />

21 CCW/ CW/QSP UP DOWN<br />

QSP<br />

PCTRL1−I−OFF = I−Anteil<br />

22 CCW/ CW/QSP UP JOG1/3 Prozeßregler ausschalt<strong>en</strong><br />

QSP<br />

DFIN1−ON = Digitaler Frequ<strong>en</strong>zeingang<br />

23 H/Re CW/ UP DOWN<br />

0 ... 10 kHz<br />

CCW<br />

PCTRL1−OFF = Prozeßregler<br />

24 H/Re PAR UP DOWN ausschalt<strong>en</strong><br />

25 H/Re DCB UP DOWN<br />

26 H/Re JOG1/3 UP DOWN<br />

27 H/Re TRIP− UP DOWN<br />

Set<br />

28 JOG2/3 JOG1/3 PCTRL1<br />

−I−OFF<br />

29 JOG2/3 DCB PCTRL1<br />

−I−OFF<br />

30 JOG2/3 QSP PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

E4 E3 E2 E1<br />

31 DCB QSP PCTRL1<br />

−I−OFF<br />

32 TRIP−<br />

Set<br />

QSP<br />

PCTRL1<br />

−I−OFF<br />

33 QSP PAR PCTRL1<br />

−I−OFF<br />

34 CW/QSP CCW/<br />

QSP<br />

PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

35 JOG2/3 JOG1/3 PAR DFIN1−O<br />

N<br />

36 DCB QSP PAR DFIN1−O<br />

N<br />

37 JOG1/3 QSP PAR DFIN1−O<br />

N<br />

38 JOG1/3 PAR TRIP−<br />

Set<br />

39 JOG2/3 JOG1/3 TRIP−<br />

Set<br />

40 JOG1/3 QSP TRIP−<br />

Set<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 53


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

Co<strong>de</strong><br />

Nr.<br />

C0007<br />

<br />

uSEr<br />

(Forts.<br />

)<br />

C0010<br />

uSEr<br />

C0011<br />

uSEr<br />

C0012<br />

uSEr<br />

C0013<br />

uSEr<br />

Bezeichnung<br />

minimale<br />

Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

maximale<br />

Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

Hochlaufzeit<br />

Hauptsollwert<br />

Ablaufzeit<br />

Hauptsollwert<br />

Einstellmöglichkeit<strong>en</strong><br />

L<strong>en</strong>ze Auswahl<br />

E4 E3 E2 E1<br />

41 JOG1/3 DCB TRIP−<br />

Set<br />

42 QSP DCB TRIP−<br />

Set<br />

43 CW/<br />

CCW<br />

QSP<br />

TRIP−<br />

Set<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

44 UP DOWN PAR DFIN1−O<br />

N<br />

45 CW/<br />

CCW<br />

QSP PAR DFIN1−O<br />

N<br />

46 H/Re PAR QSP JOG1/3<br />

47 CW/QSP CCW/ H/Re JOG1/3<br />

QSP<br />

48 PCTRL1<br />

− OFF<br />

DCB PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

49 PCTRL1<br />

− OFF<br />

50 PCTRL1<br />

− OFF<br />

JOG1/3 QSP DFIN1−O<br />

N<br />

JOG1/3<br />

PCTRL1<br />

−I−OFF<br />

51 DCB PAR PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

WICHTIG<br />

255 In C0410 wur<strong>de</strong> <strong>fr</strong>ei konfiguriert Nur Anzeige<br />

C0007 nicht än<strong>de</strong>rn, da Einstellung<strong>en</strong><br />

in C0410 verlor<strong>en</strong>geh<strong>en</strong><br />

könn<strong>en</strong><br />

0.00 0.00<br />

14.5 Hz<br />

50.00 7.50<br />

87 Hz<br />

{0.02<br />

Hz}<br />

{0.02<br />

Hz}<br />

5.00 0.00 {0.02<br />

s}<br />

5.00 0.00 {0.02<br />

s}<br />

650.00 C0010 nicht wirksam bei bipolarer<br />

Sollwertvorgabe<br />

(−10 V ... + 10 V)<br />

C0010 begr<strong>en</strong>zt nur <strong>de</strong>n<br />

Analogeingang 1<br />

650.00 Drehzahlstellbereich 1 : 6<br />

für L<strong>en</strong>ze−Getriebemotor<strong>en</strong>:<br />

Bei Betrieb mit L<strong>en</strong>ze−Getriebemotor<strong>en</strong><br />

unbedingt einstell<strong>en</strong>.<br />

1300.00 Bezug: Frequ<strong>en</strong>zän<strong>de</strong>rung 0 Hz<br />

... C0011<br />

Zusatzsollwert C0220<br />

Über Digitalsignale aktivierbare<br />

Hochlaufzeit<strong>en</strong> <br />

C0101<br />

1300.00 Bezug: Frequ<strong>en</strong>zän<strong>de</strong>rung<br />

C0011 ... 0 Hz<br />

Zusatzsollwert C0221<br />

Über Digitalsignale aktivierbare<br />

Ablaufzeit<strong>en</strong> C0103<br />

54<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

7<br />

Co<strong>de</strong><br />

Nr.<br />

C0014<br />

<br />

C0015<br />

uSEr<br />

C0016<br />

uSEr<br />

C0034<br />

*<br />

<br />

uSEr<br />

Einstellmöglichkeit<strong>en</strong><br />

Bezeichnung L<strong>en</strong>ze Auswahl<br />

Betriebsart 2 2 U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung U ~ f<br />

(lineare K<strong>en</strong>nlinie mit konstanter<br />

U min −Anhebung)<br />

U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z<br />

U min −Anhebung<br />

Bereich Sollwertvorgabe<br />

Standard–I/O<br />

(X3/8)<br />

−5−<br />

3 U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung U ~ f 2<br />

(quadratische K<strong>en</strong>nlinie mit konstanter<br />

U min −Anhebung)<br />

WICHTIG<br />

<br />

<br />

Inbetriebnahme ohne I<strong>de</strong>ntifizierung<br />

<strong>de</strong>r Motorparameter<br />

möglich<br />

Vorteil <strong>de</strong>r I<strong>de</strong>ntifizierung<br />

mit C0148:<br />

– Verbesserter Rundlauf bei<br />

klein<strong>en</strong> Drehzahl<strong>en</strong><br />

– U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z (C0015)<br />

und Schlupf (C0021)<br />

wer<strong>de</strong>n berechnet und<br />

gespeichert. Sie müss<strong>en</strong><br />

nicht eingegeb<strong>en</strong> wer<strong>de</strong>n<br />

4 Vectorregelung Beim erstmalig<strong>en</strong> Anwähl<strong>en</strong><br />

5 S<strong>en</strong>sorlose Drehmom<strong>en</strong>tregelung<br />

die Motordat<strong>en</strong> eingeb<strong>en</strong> und<br />

mit Drehzahlklammerung<br />

mit C0148 die Motorparameter<br />

i<strong>de</strong>ntifizier<strong>en</strong><br />

Drehmom<strong>en</strong>tsollwert über<br />

C0412/6<br />

Die Inbetriebnahme ist sonst<br />

nicht möglich<br />

Drehzahlklammerung über Sollwert<br />

1 (NSET1−N1), w<strong>en</strong>n<br />

C0412/1 belegt, sonst über Maximal<strong>fr</strong>equ<strong>en</strong>z<br />

(C0011)<br />

50.00 7.50 {0.02<br />

Hz}<br />

0.00 {0.01<br />

%}<br />

960.00 C0015 wird bei <strong>de</strong>r Motorparameter−I<strong>de</strong>ntifizierung<br />

mit C0148 berechnet und<br />

gespeichert.<br />

Die Einstellung gilt für alle<br />

zugelass<strong>en</strong><strong>en</strong> Netzspannung<strong>en</strong><br />

40.00 geräteabhängig<br />

Einstellung gilt für alle zugelass<strong>en</strong><strong>en</strong><br />

Netzspannung<strong>en</strong><br />

Schalterstellung <strong>de</strong>s Funktionsmoduls<br />

beacht<strong>en</strong>!<br />

0 0 Spannung unipolar 0 ... 5 V / 0 ...<br />

10 V<br />

Strom 0 ... 20 mA<br />

1 Strom 4 ... 20 mA Drehrichtungsumkehr nur mit<br />

digitalem Signal möglich.<br />

2 Spannung bipolar −10 V ... +10 V Minimale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

(C0010) nicht wirksam<br />

Offset und Verstärkung individuell<br />

abgleich<strong>en</strong><br />

3 Strom 4 ... 20 mA drahtbruchüberwacht<br />

TRIP Sd5, w<strong>en</strong>n I < 4 mA<br />

Drehrichtungsumkehr nur mit<br />

digitalem Signal möglich.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 55


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

Co<strong>de</strong><br />

Nr.<br />

C0034<br />

*<br />

<br />

(A)<br />

uSEr<br />

Bezeichnung<br />

Bereich Sollwertvorgabe<br />

Application−<br />

I/O<br />

Einstellmöglichkeit<strong>en</strong><br />

L<strong>en</strong>ze<br />

Auswahl<br />

WICHTIG<br />

Jumperstellung <strong>de</strong>s Funktionsmoduls<br />

beacht<strong>en</strong>!<br />

1 X3/1U, X3/1I 0 0 Spannung unipolar 0 ... 5 V / 0 ...<br />

10 V<br />

2 X3/2U, X3/2I 1 Spannung bipolar −10 V ... +10 V Minimale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

(C0010) nicht wirksam<br />

2 Strom 0 ... 20 mA<br />

3 Strom 4 ... 20 mA Drehrichtungsumkehr nur mit<br />

digitalem Signal möglich.<br />

C0037 JOG1 20.00 −650.00 {0.02<br />

Hz}<br />

C0038 JOG2 30.00 −650.00 {0.02<br />

Hz}<br />

C0039 JOG3 40.00 −650.00 {0.02<br />

Hz}<br />

C0050<br />

*<br />

uSEr<br />

C0087<br />

C0088<br />

C0089<br />

C0090<br />

4 Strom 4 ... 20 mA drahtbruchüberwacht<br />

Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

(MCTRL1−NO<br />

UT)<br />

Motor−Bemessungsdrehzahl<br />

Motor−Bemessungsstrom<br />

Motor−Bemessungs<strong>fr</strong>equ<strong>en</strong>z<br />

Motor−Bemessungsspannung<br />

Drehrichtungsumkehr nur mit<br />

digitalem Signal möglich.<br />

TRIP Sd5 bei I < 4 mA<br />

650.00 JOG = Festsollwert<br />

Zusätzliche Festsollwerte <br />

650.00 C0440<br />

650.00<br />

−650.00 {Hz} 650.00 Nur Anzeige: Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

ohne Schlupfkomp<strong>en</strong>sation<br />

300 {1 rpm} 16000 geräteabhängig<br />

0.0 {0.1 A} 650.0 geräteabhängig<br />

0.0 ... 2.0 x Ausgangsn<strong>en</strong>nstrom<br />

<strong>de</strong>s Antriebsreglers<br />

50 10 {1 Hz} 960<br />

50 {1 V} 500 230 V bei 230 V Antriebsreglern,<br />

400 V bei 400 V Antriebsreglern<br />

C0091 Motor cos ϕ 0.40 {0.1} 1.0 geräteabhängig<br />

56<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

7<br />

Co<strong>de</strong><br />

Nr.<br />

C0119<br />

<br />

−6−<br />

C0140<br />

*<br />

C0148<br />

*<br />

<br />

Einstellmöglichkeit<strong>en</strong><br />

Motorparameter<br />

i<strong>de</strong>ntifizier<strong>en</strong><br />

Bezeichnung L<strong>en</strong>ze Auswahl<br />

Konfiguration 0 0 PTC−Eingang inaktiv<br />

Motortemperatur−Überwachung<br />

1 PTC−Eingang aktiv,<br />

(PTC−Eingang)<br />

/ Erd-<br />

TRIP erfolgt<br />

schlußerk<strong>en</strong>-<br />

2 PTC−Eingang ak-<br />

nung<br />

tiv,<br />

Warnung erfolgt<br />

3 PTC−Eingang inaktiv<br />

4 PTC−Eingang aktiv,<br />

TRIP erfolgt<br />

5 PTC−Eingang aktiv,<br />

Warnung erfolgt<br />

Additiver Frequ<strong>en</strong>zsollwert<br />

0.00 −650.00 {0.02<br />

Hz}<br />

(NSET1−NADD<br />

)<br />

Erdschlußerk<strong>en</strong>nung<br />

aktiv<br />

Erdschlußerk<strong>en</strong>nung<br />

inaktiv<br />

WICHTIG<br />

Signalausgabe konfigurier<strong>en</strong><br />

in C0415<br />

Bei Einsatz mehrerer Parametersätze<br />

muss die Überwachung<br />

für je<strong>de</strong>n Parametersatz<br />

getr<strong>en</strong>nt eingestellt<br />

wer<strong>de</strong>n.<br />

Erdschlußerk<strong>en</strong>nung <strong>de</strong>aktivier<strong>en</strong>,<br />

w<strong>en</strong>n die Erdschlußerk<strong>en</strong>nung<br />

unbeabsichtigt<br />

ausgelöst wird.<br />

Bei aktivierter Erdschlußerk<strong>en</strong>nung<br />

läuft <strong>de</strong>r Motor<br />

nach Regler<strong>fr</strong>eigabe um ca.<br />

40 ms verzögert an.<br />

650.00 Vorgabe über Funktion <br />

<strong>de</strong>s Keypad o<strong>de</strong>r Parameterkanal<br />

Wirkt additiv auf <strong>de</strong>n Hauptsollwert<br />

Wert wird bei Netzschalt<strong>en</strong><br />

o<strong>de</strong>r bei Abzieh<strong>en</strong> <strong>de</strong>s Keypad<br />

gespeichert<br />

0 0 Bereit Nur bei kaltem Motor durchführ<strong>en</strong>!<br />

1. Regler sperr<strong>en</strong>, wart<strong>en</strong> bis<br />

Antrieb steht<br />

2. In C0087, C0088, C0089,<br />

1 I<strong>de</strong>ntifizierung start<strong>en</strong><br />

U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z (C0015),<br />

Schlupfkomp<strong>en</strong>sation (C0021)<br />

und Motor−Stän<strong>de</strong>rinduktivität<br />

(C0092) wer<strong>de</strong>n berechnet und<br />

gespeichert<br />

Der Motor−Stän<strong>de</strong>rwi<strong>de</strong>rstand<br />

(C0084) = Gesamtwi<strong>de</strong>rstand<br />

von Motorleitung und Motor wird<br />

gemess<strong>en</strong> und gespeichert<br />

C0090, C0091 die korrekt<strong>en</strong><br />

Werte vom Motor−Typ<strong>en</strong>schild<br />

eingeb<strong>en</strong><br />

3. C0148 = 1 setz<strong>en</strong>, mit <br />

bestätig<strong>en</strong><br />

4. Regler <strong>fr</strong>eigeb<strong>en</strong>:<br />

Die I<strong>de</strong>ntifizierung<br />

– startet, erlischt<br />

– <strong>de</strong>r Motor "pfeift" leise,<br />

dreht sich aber nicht!<br />

– dauert ca. 30 s<br />

– ist be<strong>en</strong><strong>de</strong>t, w<strong>en</strong>n <br />

wie<strong>de</strong>r leuchtet<br />

5. Regler sperr<strong>en</strong><br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 57


7 Inbetriebnahme<br />

Die wichtigst<strong>en</strong> Co<strong>de</strong>s für die Inbetriebnahme<br />

C0608<br />

*<br />

Co<strong>de</strong><br />

Einstellmöglichkeit<strong>en</strong><br />

WICHTIG<br />

Nr. Bezeichnung L<strong>en</strong>ze Auswahl<br />

C0517<br />

*<br />

<br />

User−M<strong>en</strong>ü Nach Netzschalt<strong>en</strong> o<strong>de</strong>r in<br />

<strong>de</strong>r Funktion wird <strong>de</strong>r<br />

Co<strong>de</strong> aus C0517/1 angezeigt.<br />

1 Speicher 1 50 C0050 Ausgangs<strong>fr</strong>equ<strong>en</strong>z (MCTRL1−NOUT) Das User−M<strong>en</strong>ü <strong>en</strong>thält in<br />

2 Speicher 2 34 C0034 Bereich analoge Sollwertvorgabe<br />

<strong>de</strong>r L<strong>en</strong>ze−Einstellung die<br />

wichtigst<strong>en</strong> Co<strong>de</strong>s für die<br />

3 Speicher 3 7 C0007 Feste Konfiguration digitale Eingangssignale<br />

Inbetriebnahme <strong>de</strong>r Betriebsart<br />

"U/f−K<strong>en</strong>nlini<strong>en</strong>steuerung<br />

mit linearer K<strong>en</strong>nlinie"<br />

4 Speicher 4 10 C0010 Minimale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

Bei aktivem Paßwortschutz<br />

5 Speicher 5 11 C0011 Maximale Ausgangs<strong>fr</strong>equ<strong>en</strong>z<br />

sind nur die in C0517 eingetrag<strong>en</strong><strong>en</strong><br />

Co<strong>de</strong>s <strong>fr</strong>ei zugänglich<br />

6 Speicher 6 12 C0012 Hochlaufzeit Hauptsollwert<br />

7 Speicher 7 13 C0013 Ablaufzeit Hauptsollwert<br />

Unter <strong>de</strong>n Subco<strong>de</strong>s die<br />

Nummern <strong>de</strong>r gewünscht<strong>en</strong><br />

8 Speicher 8 15 C0015 U/f−N<strong>en</strong>n<strong>fr</strong>equ<strong>en</strong>z<br />

Co<strong>de</strong>s eintrag<strong>en</strong><br />

9 Speicher 9 16 C0016 U min −Anhebung<br />

Co<strong>de</strong>s, die nur zusamm<strong>en</strong><br />

mit Application−I/O aktiv<br />

10 Speicher 10 2 C0002 Parametersatz−Transfer<br />

sind, könn<strong>en</strong> nicht eingetrag<strong>en</strong><br />

wer<strong>de</strong>n!<br />

Lüfterüberwachung<br />

0 0 inaktiv <strong>82</strong>00 <strong>motec</strong> 3 ... 7,5 <strong>kW</strong>:<br />

Funktion unbedingt bei <strong>de</strong>r Inbetriebnahme<br />

aktivier<strong>en</strong>! Der<br />

1 TRIP−Fehlermeldung<br />

Antriebsregler kann sonst<br />

durch Überhitzung zerstört<br />

wer<strong>de</strong>n.<br />

2 Warnung<br />

Alle an<strong>de</strong>r<strong>en</strong> Antriebsregler:<br />

Unbedingt C0608 = 0 einstell<strong>en</strong>.<br />

58<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Fehlverhalt<strong>en</strong> <strong>de</strong>s Antriebs<br />

8<br />

Fehlverhalt<strong>en</strong> Ursache Abhilfe<br />

Motor dreht nicht<br />

Zwisch<strong>en</strong>kreisspannung zu niedrig<br />

(Rote LED blinkt im 0.4 s Takt;<br />

Anzeige Keypad: LU)<br />

Netzspannung prüf<strong>en</strong><br />

Antriebsregler gesperrt<br />

(Grüne LED blinkt, Anzeige Keypad:<br />

)<br />

Automatischer Start gesperrt (C0142 =<br />

0 o<strong>de</strong>r 2)<br />

Gleichstrombremsung (DCB) aktiv<br />

Mechanische Motorbremse ist nicht gelöst<br />

Quickstop (QSP) aktiv (Anzeige Keypad:<br />

)<br />

Sollwert = 0<br />

JOG−Sollwert aktiviert und JOG−Frequ<strong>en</strong>z<br />

= 0<br />

Störung aktiv<br />

Falscher Parametersatz aktiv<br />

Betriebsart C0014 = −4−, −5− eingestellt,<br />

aber keine Motorparameter−I<strong>de</strong>ntifizierung<br />

durchgeführt<br />

Belegung mehrerer, sich ausschließ<strong>en</strong><strong>de</strong>r<br />

Funktion<strong>en</strong> mit einer Signalquelle in<br />

C0410<br />

Reglersperre aufheb<strong>en</strong>, Reglersperre<br />

kann über mehrere<br />

Quell<strong>en</strong> gesetzt sein<br />

LOW−HIGH−Flanke an X3/28<br />

Evtl. Startbedingung (C0142)<br />

korrigier<strong>en</strong><br />

Gleichstrombremse <strong>de</strong>aktivier<strong>en</strong><br />

Mechanische Motorbremse<br />

manuell o<strong>de</strong>r elektrisch lös<strong>en</strong><br />

Quickstop aufheb<strong>en</strong><br />

Sollwert vorgeb<strong>en</strong><br />

JOG−Sollwert vorgeb<strong>en</strong><br />

(C0037 ... C0039)<br />

Störung beseitig<strong>en</strong><br />

Auf richtig<strong>en</strong> Parametersatz<br />

über Klemme umschalt<strong>en</strong><br />

Motorparameter i<strong>de</strong>ntifizier<strong>en</strong><br />

(C0148)<br />

Konfiguration in C0410 korrigier<strong>en</strong><br />

Interne Spannungsquelle X3/20 verw<strong>en</strong><strong>de</strong>t<br />

Klemm<strong>en</strong> brück<strong>en</strong><br />

bei <strong>de</strong>n Funktionsmodul<strong>en</strong> Stan-<br />

dard−I/O, INTERBUS, PROFIBUS−DP o<strong>de</strong>r<br />

LECOM−B (RS485):<br />

Brücke zwisch<strong>en</strong> X3/7 und X3/39 fehlt<br />

Motor dreht ungleichmäßig Motorleitung <strong>de</strong>fekt Motorleitung prüf<strong>en</strong><br />

Maximalstrom zu gering eingestellt<br />

(C0022, C0023)<br />

Motor unter− bzw. übererregt<br />

C0084, C0087, C0088, C0089, C0090,<br />

C0091 und/o<strong>de</strong>r C0092 nicht an die<br />

Motordat<strong>en</strong> angepaßt<br />

Einstellung<strong>en</strong> an die Anw<strong>en</strong>dung<br />

anpass<strong>en</strong><br />

Parametrierung kontrollier<strong>en</strong><br />

(C0015, C0016, C0014)<br />

Manuell anpass<strong>en</strong> o<strong>de</strong>r Motorparameter<br />

i<strong>de</strong>ntifizier<strong>en</strong><br />

(C0148)<br />

Motor nimmt zuviel Strom auf Einstellung von C0016 zu groß gewählt Einstellung korrigier<strong>en</strong><br />

Einstellung von C0015 zu klein gewählt Einstellung korrigier<strong>en</strong><br />

C0084, C0087, C0088, C0089, C0090,<br />

C0091 und/o<strong>de</strong>r C0092 nicht an die<br />

Motordat<strong>en</strong> angepaßt<br />

Manuell anpass<strong>en</strong> o<strong>de</strong>r Motorparameter<br />

i<strong>de</strong>ntifizier<strong>en</strong><br />

(C0148)<br />

Motor dreht, Sollwerte sind 0"<br />

Mit <strong>de</strong>r Funktion <strong>de</strong>s Keypad<br />

wur<strong>de</strong> ein Sollwert vorgegeb<strong>en</strong><br />

Sollwert auf "0" setz<strong>en</strong> mit<br />

C0140 = 0<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 59


8<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Fehlverhalt<strong>en</strong> <strong>de</strong>s Antriebs<br />

Fehlverhalt<strong>en</strong><br />

Motorparameter−I<strong>de</strong>ntifizierung<br />

bricht ab mit Fehler LP1<br />

Antriebsverhalt<strong>en</strong> bei Vector−Regelung<br />

nicht zu<strong>fr</strong>ie<strong>de</strong>nstell<strong>en</strong>d<br />

Einbruch <strong>de</strong>s Drehmom<strong>en</strong>ts im<br />

Feldschwächbereich<br />

Kipp<strong>en</strong> <strong>de</strong>s Motors bei Betrieb im<br />

Feldschwächbereich<br />

Ursache<br />

Abhilfe<br />

Motor ist zu klein im Verhältnis zur Geräte−N<strong>en</strong>nleistung<br />

Gleichstrombremse (DCB) über Klemme<br />

aktiv<br />

verschie<strong>de</strong>ne<br />

Vector−Regelung optimier<strong>en</strong><br />

( 47)<br />

verschie<strong>de</strong>ne<br />

Rücksprache mit L<strong>en</strong>ze<br />

60<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


PS<br />

<br />

<br />

<br />

m<br />

Hi<br />

Hz V A<br />

Lo<br />

%sh<br />

rpm Ω°C<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

8<br />

LED’s am Antriebsregler (Statusanzeige)<br />

LED −7−<br />

rot <br />

grün <br />

Betriebszustand<br />

aus ein Antriebsregler <strong>fr</strong>eigegeb<strong>en</strong><br />

ein ein Netz eingeschaltet und automatischer<br />

Start gesperrt<br />

aus blinkt langsam Antriebsregler gesperrt<br />

aus blinkt schnell Motorparameter−I<strong>de</strong>ntifizierung wird<br />

durchgeführt<br />

blinkt schnell aus Unterspannungsabschaltung<br />

blinkt langsam aus Störung aktiv, Kontrolle in C0161<br />

<br />

<br />

1<br />

8888888 8<br />

88888<br />

<br />

<br />

<br />

<br />

<br />

<br />

2<br />

<br />

<br />

<br />

01 61 000 1<br />

880Hr<br />

<br />

<br />

<br />

PS<br />

Hi<br />

Lo<br />

<br />

m<br />

Hz V A<br />

%sh<br />

rpm Ω°C<br />

3<br />

X3<br />

20 28<br />

5<br />

OFF<br />

4 6 ON<br />

<strong>82</strong>mot355<br />

So setz<strong>en</strong> Sie <strong>de</strong>n Antriebsregler zurück, w<strong>en</strong>n eine Störung auftritt (TRIP−<br />

Reset):<br />

1. Währ<strong>en</strong>d <strong>de</strong>s Betriebs Keypad auf die AIF−Schnittstelle aufsteck<strong>en</strong>.<br />

2. Fehlermeldung <strong>de</strong>r Keypad−Anzeige ables<strong>en</strong> und notier<strong>en</strong>.<br />

3. Antriebsregler sperr<strong>en</strong>.<br />

4. Antriebsregler vom Netz tr<strong>en</strong>n<strong>en</strong>.<br />

5. Fehleranalyse durchführ<strong>en</strong> und Fehler beseitig<strong>en</strong>.<br />

6. Antriebsregler erneut einschalt<strong>en</strong>.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 61


8<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

Störungsmeldung<strong>en</strong> am Keypad o<strong>de</strong>r im Parametrierprogramm<br />

Global Drive Control<br />

Keypad PC 1) Störung Ursache Abhilfe<br />

noer 0 keine Störung − −<br />

ccr<br />

<br />

ce0<br />

<br />

ce1<br />

<br />

ce2<br />

<br />

ce3<br />

<br />

ce4<br />

<br />

ce5<br />

<br />

71 Systemstörung starke Störeinkopplung<strong>en</strong> auf<br />

Steuerleitung<strong>en</strong><br />

Masse− o<strong>de</strong>r Erdschleif<strong>en</strong> in<br />

<strong>de</strong>r Verdrahtung<br />

61 Kommunikationsfehler<br />

an AIF<br />

(konfigurierbar in<br />

C0126)<br />

62 Kommunikationsfehler<br />

an CAN−IN1<br />

bei Sync−Steuerung<br />

63 Kommunikationsfehler<br />

an CAN−IN2<br />

64 Kommunikationsfehler<br />

an CAN−IN1<br />

bei Ereignis− bzw.<br />

Zeitsteuerung<br />

65 BUS−OFF<br />

(viele Kommunikationsfehler<br />

aufgetret<strong>en</strong>)<br />

66 CAN Time−Out<br />

(konfigurierbar in<br />

C0126)<br />

Übertragung von Steuerbefehl<strong>en</strong><br />

über AIF ist gestört<br />

CAN−IN1−Objekt empfängt fehlerhafte<br />

Dat<strong>en</strong> o<strong>de</strong>r Kommunikation<br />

ist unterbroch<strong>en</strong><br />

CAN−IN2−Objekt empfängt fehlerhafte<br />

Dat<strong>en</strong> o<strong>de</strong>r Kommunikation<br />

ist unterbroch<strong>en</strong><br />

CAN−IN1−Objekt empfängt fehlerhafte<br />

Dat<strong>en</strong> o<strong>de</strong>r Kommunikation<br />

ist unterbroch<strong>en</strong><br />

Antriebsregler hat zu viele fehlerhafte<br />

Telegramme über Systembus<br />

empfang<strong>en</strong> und sich<br />

vom Bus abgekoppelt<br />

Bei Fernparametrierung über<br />

Systembus (C0370):<br />

Slave antwortet nicht. Kommunikations−Überwachungszeit<br />

überschritt<strong>en</strong><br />

Bei Betrieb mit Application−I/O:<br />

Parametersatz−Umschaltung<br />

falsch parametriert<br />

Bei Betrieb mit Modul auf FIF:<br />

Interner Fehler<br />

Steuerleitung abgeschirmt verleg<strong>en</strong><br />

Kommunikationsmodul fest in das<br />

Handterminal steck<strong>en</strong><br />

Steckverbindung Busmodul<br />

FIF prüf<strong>en</strong><br />

S<strong>en</strong><strong>de</strong>r überprüf<strong>en</strong><br />

evtl. Überwachungszeit in<br />

C0357/1 erhöh<strong>en</strong><br />

Steckverbindung Busmodul<br />

FIF prüf<strong>en</strong><br />

S<strong>en</strong><strong>de</strong>r überprüf<strong>en</strong><br />

evtl. Überwachungszeit in<br />

C0357/2 erhöh<strong>en</strong><br />

Steckverbindung Busmodul <br />

FIF prüf<strong>en</strong><br />

S<strong>en</strong><strong>de</strong>r überprüf<strong>en</strong><br />

evtl. Überwachungszeit in<br />

C0357/3 erhöh<strong>en</strong><br />

Prüf<strong>en</strong>, ob Busabschluß vorhan<strong>de</strong>n<br />

Schirmauflage <strong>de</strong>r Leitung<strong>en</strong><br />

prüf<strong>en</strong><br />

PE−Anbindung prüf<strong>en</strong><br />

Busbelastung prüf<strong>en</strong>, ggf.<br />

Baud−Rate reduzier<strong>en</strong><br />

Verdrahtung <strong>de</strong>s Systembus<br />

prüf<strong>en</strong><br />

Systembus−Konfiguration prüf<strong>en</strong><br />

In all<strong>en</strong> Parametersätz<strong>en</strong> muß das<br />

Signal "Parametersatz umschalt<strong>en</strong>"<br />

(C0410/13, C0410/14) mit<br />

<strong>de</strong>r gleich<strong>en</strong> Quelle verknüpft sein<br />

Rücksprache mit L<strong>en</strong>ze erfor<strong>de</strong>rlich<br />

62<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

8<br />

Keypad<br />

ce6<br />

<br />

ce7<br />

<br />

EEr<br />

<br />

ErP0<br />

...<br />

ErP19<br />

<br />

FAn1<br />

<br />

PC 1)<br />

Störung<br />

67 Funktionsmodul<br />

Systembus (CAN)<br />

auf FIF ist im Zustand<br />

"Warnung"<br />

o<strong>de</strong>r "BUS−OFF"<br />

(konfigurierbar in<br />

C0126)<br />

68 Kommunikationsfehler<br />

bei Fernparametrierung<br />

über<br />

Systembus<br />

(C0370)<br />

(konfigurierbar in<br />

C0126)<br />

91 Externe Störung<br />

(TRIP−SET)<br />

−<br />

Kommunikationsabbruch<br />

zwisch<strong>en</strong><br />

Keypad und<br />

Grundgerät<br />

Ursache<br />

Abhilfe<br />

CAN Controller mel<strong>de</strong>t Zustand Prüf<strong>en</strong>, ob Busabschluß vorhan<strong>de</strong>n<br />

"Warnung" o<strong>de</strong>r "BUS−OFF"<br />

Schirmauflage <strong>de</strong>r Leitung<strong>en</strong><br />

prüf<strong>en</strong><br />

PE−Anbindung prüf<strong>en</strong><br />

Busbelastung prüf<strong>en</strong>, ggf.<br />

Baud−Rate reduzier<strong>en</strong><br />

Teilnehmer antwortet nicht Prüf<strong>en</strong>, ob Busabschluß vorhan<strong>de</strong>n<br />

o<strong>de</strong>r ist nicht vorhan<strong>de</strong>n<br />

Schirmauflage <strong>de</strong>r Leitung<strong>en</strong><br />

prüf<strong>en</strong><br />

PE−Anbindung prüf<strong>en</strong><br />

Busbelastung prüf<strong>en</strong>, ggf.<br />

Baud−Rate reduzier<strong>en</strong><br />

Bei Betrieb mit Application−I/O:<br />

Parametersatz−Umschaltung<br />

falsch parametriert<br />

Ein mit <strong>de</strong>r Funktion TRIP−Set<br />

belegtes digitales Signal ist<br />

aktiviert<br />

verschie<strong>de</strong>ne<br />

95 Lüfterbaugruppe<br />

E<strong>82</strong>ZMV<br />

(nur <strong>82</strong>00 <strong>motec</strong><br />

3 ... 7,5 <strong>kW</strong>)<br />

Lüfterbaugruppe <strong>de</strong>fekt<br />

FAn1 − TRIP o<strong>de</strong>r Warnung<br />

konfigurierschloss<strong>en</strong><br />

Lüfterbaugruppe nicht angebar<br />

in C0608<br />

H05<br />

<br />

id1<br />

<br />

LP1<br />

<br />

In all<strong>en</strong> Parametersätz<strong>en</strong> muß das<br />

Signal "Parametersatz umschalt<strong>en</strong>"<br />

(C0410/13, C0410/14) mit<br />

<strong>de</strong>r gleich<strong>en</strong> Quelle verknüpft sein<br />

Extern<strong>en</strong> Geber überprüf<strong>en</strong><br />

Rücksprache mit L<strong>en</strong>ze erfor<strong>de</strong>rlich<br />

Lüfterbaugruppe tausch<strong>en</strong><br />

Lüfterbaugruppe anschließ<strong>en</strong><br />

Verdrahtung prüf<strong>en</strong><br />

105 Interne Störung Rücksprache mit L<strong>en</strong>ze erfor<strong>de</strong>rlich<br />

140 Fehlerhafte Parameter−I<strong>de</strong>ntifizierung<br />

32 Fehler in Motorphase<br />

(Anzeige, w<strong>en</strong>n<br />

C0597 = 1)<br />

LP1 1<strong>82</strong> Fehler in Motorphase<br />

(Anzeige, w<strong>en</strong>n<br />

C0597 = 2)<br />

Motor nicht angeschloss<strong>en</strong><br />

Motor anschließ<strong>en</strong><br />

Ausfall einer/mehrerer Motorphas<strong>en</strong><br />

Motorzuleitung<strong>en</strong> prüf<strong>en</strong><br />

U min −Anhebung prüf<strong>en</strong>,<br />

Zu geringer Motorstrom Motor mit <strong>en</strong>tsprech<strong>en</strong><strong>de</strong>r Leistung<br />

anschließ<strong>en</strong> o<strong>de</strong>r mit<br />

C0599 Motor anpass<strong>en</strong><br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 63


8<br />

Keypad<br />

LU<br />

<br />

OC1<br />

<br />

OC2<br />

<br />

OC3<br />

<br />

OC4<br />

<br />

OC5<br />

<br />

OC6<br />

<br />

OH<br />

<br />

OH<br />

<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

PC 1)<br />

−<br />

Störung<br />

Zwisch<strong>en</strong>kreis−Unterspannung<br />

Ursache<br />

Netzspannung zu niedrig<br />

Spannung im DC−Verbund zu<br />

niedrig<br />

400 V−Antriebsregler an 240<br />

V−Netz angeschloss<strong>en</strong><br />

Abhilfe<br />

Netzspannung prüf<strong>en</strong><br />

Versorgungsmodul prüf<strong>en</strong><br />

Antriebsregler an richtige Netzspannung<br />

anschließ<strong>en</strong><br />

11 Kurzschluß Kurzschluß Kurzschlußursache such<strong>en</strong>;<br />

Motorleitung prüf<strong>en</strong><br />

Bremswi<strong>de</strong>rstand und Leitung<br />

zum Bremswi<strong>de</strong>rstand prüf<strong>en</strong><br />

Kapazitiver La<strong>de</strong>strom <strong>de</strong>r Motorleitung<br />

zu hoch<br />

12 Erdschluß Eine Motorphase hat Erdkontakt<br />

13 Überlast Antriebsregler<br />

im Hochlauf<br />

o<strong>de</strong>r Kurzschluß<br />

14 Überlast Antriebsregler<br />

im Ablauf<br />

15 Überlast Antriebsregler<br />

im stationär<strong>en</strong><br />

Betrieb<br />

16 Überlast Motor<br />

(I 2 x t − Überlast)<br />

50 Kühlkörpertemperatur<br />

> +85 °C<br />

−<br />

Kühlkörpertemperatur<br />

> +80 °C<br />

Kapazitiver La<strong>de</strong>strom <strong>de</strong>r Motorleitung<br />

zu hoch<br />

Zu kurz eingestellte Hochlaufzeit<br />

(C0012)<br />

Defekte Motorleitung<br />

Windungsschluß im Motor<br />

Zu kurz eingestellte Ablaufzeit<br />

(C0013)<br />

Häufige und zu lange Überlast<br />

Motor thermisch überlastet<br />

durch z. B.<br />

Kürzere/kapazitätsärmere Motorleitung<br />

verw<strong>en</strong><strong>de</strong>n<br />

Motor überprüf<strong>en</strong>; Motorleitung<br />

prüf<strong>en</strong><br />

Kürzere/kapazitätsärmere Motorleitung<br />

verw<strong>en</strong><strong>de</strong>n<br />

Erdschlußerk<strong>en</strong>nung zu Prüfzwekk<strong>en</strong><br />

<strong>de</strong>aktivier<strong>en</strong><br />

Hochlaufzeit verlängern<br />

Antriebsauslegung prüf<strong>en</strong><br />

Verdrahtung überprüf<strong>en</strong><br />

Motor überprüf<strong>en</strong><br />

Ablaufzeit verlängern<br />

Auslegung <strong>de</strong>s extern<strong>en</strong><br />

Bremswi<strong>de</strong>rstands prüf<strong>en</strong><br />

Antriebsauslegung prüf<strong>en</strong><br />

unzulässig<strong>en</strong> Dauerstrom Antriebsauslegung prüf<strong>en</strong><br />

häufige o<strong>de</strong>r zu lange Beschleunigungsvorgänge<br />

Einstellung von C0120 prüf<strong>en</strong><br />

Umgebungstemperatur zu<br />

hoch<br />

Kühlkörper stark verschmutzt<br />

Unzulässig hohe Ströme o<strong>de</strong>r<br />

häufige und zu lange Beschleunigungsvorgänge<br />

Antriebsregler abkühl<strong>en</strong> lass<strong>en</strong><br />

und für eine bessere Belüftung<br />

sorg<strong>en</strong><br />

Kühlkörper reinig<strong>en</strong><br />

Antriebsauslegung überprüf<strong>en</strong><br />

Last überprüf<strong>en</strong>, ggf. schwergängige,<br />

<strong>de</strong>fekte Lager auswechseln<br />

64<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

8<br />

Keypad<br />

OH3<br />

<br />

OH4<br />

<br />

PC 1)<br />

Störung<br />

53 PTC−Überwachung<br />

(TRIP)<br />

(Anzeige, w<strong>en</strong>n<br />

C0119 = 1 o<strong>de</strong>r 4)<br />

54 Übertemperatur<br />

Antriebsregler<br />

OH51 203 PTC−Überwachung<br />

(Anzeige, w<strong>en</strong>n<br />

C0119 = 2 o<strong>de</strong>r 5)<br />

OU<br />

<br />

OUE<br />

<br />

Pr<br />

<br />

Pr1<br />

<br />

Pr2<br />

<br />

Pr3<br />

<br />

Pr4<br />

<br />

−<br />

Zwisch<strong>en</strong>kreis−<br />

Überspannung<br />

(Meldung o<strong>de</strong>r<br />

TRIP konfigurierbar<br />

in C0310)<br />

Ursache<br />

Motor zu warm durch unzulässig<br />

hohe Ströme o<strong>de</strong>r häufige<br />

und zu lange Beschleunigungsvorgänge<br />

Abhilfe<br />

Antriebsauslegung prüf<strong>en</strong><br />

Kein PTC angeschloss<strong>en</strong> PTC anschließ<strong>en</strong> o<strong>de</strong>r Überwachung<br />

abschalt<strong>en</strong><br />

Inn<strong>en</strong>raum <strong>de</strong>s Antriebsreglers Belastung <strong>de</strong>s Antriebsreglers<br />

zu warm<br />

s<strong>en</strong>k<strong>en</strong><br />

Kühlung verbessern<br />

Lüfter im Antriebsregler prüf<strong>en</strong><br />

Motor zu warm durch unzulässig<br />

hohe Ströme o<strong>de</strong>r häufige<br />

und zu lange Beschleunigungsvorgänge<br />

Kein PTC angeschloss<strong>en</strong><br />

Netzspannung zu hoch<br />

Antriebsauslegung prüf<strong>en</strong><br />

PTC anschließ<strong>en</strong> o<strong>de</strong>r Überwachung<br />

abschalt<strong>en</strong><br />

Versorgungsspannung kontrollier<strong>en</strong><br />

22 Bremsbetrieb Ablaufzeit<strong>en</strong> verlängern<br />

<br />

75 Parameter−Übertragung<br />

mit <strong>de</strong>m<br />

Keypad fehlerhaft<br />

72 PAR1 mit <strong>de</strong>m<br />

Keypad falsch<br />

übertrag<strong>en</strong><br />

73 PAR2 mit <strong>de</strong>m<br />

Keypad falsch<br />

übertrag<strong>en</strong><br />

77 PAR3 mit <strong>de</strong>m<br />

Keypad falsch<br />

übertrag<strong>en</strong><br />

78 PAR4 mit <strong>de</strong>m<br />

Keypad falsch<br />

übertrag<strong>en</strong><br />

Schleich<strong>en</strong><strong>de</strong>r Erdschluß auf<br />

<strong>de</strong>r Motorseite<br />

Alle Parametersätze sind <strong>de</strong>fekt<br />

Parametersatz 1 ist <strong>de</strong>fekt<br />

Parametersatz 2 ist <strong>de</strong>fekt<br />

Parametersatz 3 ist <strong>de</strong>fekt<br />

Parametersatz 4 ist <strong>de</strong>fekt<br />

Bei Betrieb mit externem<br />

Bremswi<strong>de</strong>rstand:<br />

– Dim<strong>en</strong>sionierung, Anschluß<br />

und Zuleitung <strong>de</strong>s Bremswi<strong>de</strong>rstands<br />

prüf<strong>en</strong><br />

– Ablaufzeit<strong>en</strong> verlängern<br />

Motorzuleitung und Motor auf Erdschluß<br />

prüf<strong>en</strong> (Motor vom Umrichter<br />

tr<strong>en</strong>n<strong>en</strong>)<br />

Vor Regler<strong>fr</strong>eigabe unbedingt <strong>de</strong>n<br />

Dat<strong>en</strong>transfer wie<strong>de</strong>rhol<strong>en</strong> o<strong>de</strong>r<br />

die L<strong>en</strong>ze−Einstellung la<strong>de</strong>n<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 65


8<br />

Keypad<br />

Pr5<br />

<br />

Pt5<br />

<br />

rSt<br />

<br />

sd5<br />

<br />

sd7<br />

<br />

Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

PC 1)<br />

Störung<br />

Ursache<br />

Abhilfe<br />

79 Interne Störung EEPROM <strong>de</strong>fekt Rücksprache mit L<strong>en</strong>ze erfor<strong>de</strong>rlich<br />

81 Zeitfehler bei Parametersatz−<br />

Transfer<br />

76 Fehler bei Auto−<br />

TRIP−Reset<br />

85 Drahtbruch Analogeingang<br />

1<br />

87 Drahtbruch Analogeingang<br />

2<br />

Dat<strong>en</strong>fluß vom Keypad o<strong>de</strong>r<br />

vom PC unterbroch<strong>en</strong>, z. B.<br />

Keypad wur<strong>de</strong> währ<strong>en</strong>d <strong>de</strong>r<br />

Dat<strong>en</strong>übertragung abgezog<strong>en</strong><br />

Mehr als 8 Fehlermeldung<strong>en</strong><br />

in 10 Minut<strong>en</strong><br />

Strom am Analogeingang<br />

< 4 mA bei Sollwertbereich<br />

4 ... 20 mA<br />

Vor Regler<strong>fr</strong>eigabe unbedingt <strong>de</strong>n<br />

Dat<strong>en</strong>transfer wie<strong>de</strong>rhol<strong>en</strong> o<strong>de</strong>r<br />

L<strong>en</strong>ze−Einstellung la<strong>de</strong>n.<br />

Abhängig von <strong>de</strong>r Fehlermeldung<br />

Stromkreis am Analogeingang<br />

schließ<strong>en</strong><br />

1) LECOM−Fehlernummer, Anzeige im Parametrierprogramm Global Drive Control (GDC)<br />

66<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Störung<strong>en</strong> erk<strong>en</strong>n<strong>en</strong> und beseitig<strong>en</strong><br />

Störungsmeldung<strong>en</strong><br />

8<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 67


This docum<strong>en</strong>tation is only valid for <strong>82</strong>00 <strong>motec</strong> inverters as of version<br />

E<strong>82</strong>MV xxx _ 4 B001 XX 1x 3x<br />

Type<br />

551 = 550 W<br />

751 = 750 W<br />

152 = 1.5 <strong>kW</strong><br />

222 = <strong>2.2</strong> <strong>kW</strong><br />

4 = 400 V Hardware version Software version<br />

l<br />

<strong>82</strong>00mot166<br />

Note!<br />

Curr<strong>en</strong>t docum<strong>en</strong>tation and software updates for L<strong>en</strong>ze<br />

products can be found on the internet in the "Downloads" area<br />

un<strong>de</strong>r<br />

http://www.L<strong>en</strong>ze.com


PS<br />

<br />

<br />

V<br />

%sh<br />

Lo<br />

PE<br />

U1 V 1 W1<br />

V2 U2 2 W<br />

Commissioning of the <strong>82</strong>00 <strong>motec</strong> without function module<br />

<br />

<br />

<br />

<br />

The <strong>82</strong>00 <strong>motec</strong> can only be used wh<strong>en</strong> the FIF<br />

cover is mounted! (Delivery status).<br />

– If the FIF cover is not mounted, the <strong>82</strong>00 <strong>motec</strong><br />

will be inhibited (keypad: ).<br />

Since the <strong>82</strong>00 <strong>motec</strong> does not provi<strong>de</strong> any control<br />

terminals wh<strong>en</strong> the function module is not attached,<br />

starting and stopping during operation is possible by<br />

switching the mains.<br />

Function stores the setpoint at the time wh<strong>en</strong><br />

operation is interrupted by switching the mains or<br />

mains failures. The drive restarts automatically as<br />

soon as the mains connection is built up again.<br />

If the drive does not start at step ( is not<br />

off), press to <strong>en</strong>able the <strong>82</strong>00 <strong>motec</strong>.<br />

A<br />

<strong>82</strong>00mot146<br />

E<strong>82</strong>ZWLxxx<br />

L1/L2/L3/PE<br />

rpm<br />

°C<br />

8888888 8<br />

m A<br />

<br />

<br />

<br />

<br />

<br />

E<strong>82</strong>ZBB<br />

88888<br />

<br />

Hi Hz<br />

1 2<br />

<br />

<br />

0140<br />

3<br />

5000<br />

Hz<br />

AIF<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

0....+50 Hz<br />

<strong>82</strong>00mot170<br />

0....- 50 Hz<br />

Step Note see chapter<br />

<br />

<br />

<br />

Connect the hand<br />

terminal (with keypad)<br />

with the <strong>motec</strong>. Plug the<br />

connector of the cable<br />

into the AIF interface at<br />

the <strong>motec</strong>.<br />

Switch on the mains<br />

voltage.<br />

Self start possible!<br />

Hand terminal and connection cable are not inclu<strong>de</strong>d in the<br />

<strong>de</strong>livery package.<br />

The controller is ready for operation after approx. 1<br />

second.<br />

Keypad: <br />

Select the setpoint via activate <br />

the function .<br />

CW rotation is off. The drive should be<br />

running now.<br />

CCW rotation Display indicates output <strong>fr</strong>equ<strong>en</strong>cy.<br />

Any faults or errors during commissioning or operation?<br />

7


i<br />

Cont<strong>en</strong>ts<br />

Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

L<strong>en</strong>ze controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

Three−phase AC machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74<br />

Residual hazards, layout of safety instructions . . . . . . . . . . . . . . . . . . . . 77<br />

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

Standards and application conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 80<br />

G<strong>en</strong>eral electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81<br />

Dim<strong>en</strong>sions, mechanical <strong>de</strong>sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <strong>82</strong><br />

<strong>motec</strong> with motor or geared motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83<br />

Wiring according to EMC requirem<strong>en</strong>ts . . . . . . . . . . . . . . . . . . . . . . . . . 84<br />

Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85<br />

Delivery package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85<br />

Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86<br />

Motor connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88<br />

Wiring according to EMC requirem<strong>en</strong>ts . . . . . . . . . . . . . . . . . . . . . . . . . 90<br />

Motor mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91<br />

Delivery package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91<br />

Preparations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />

Motor connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

Wiring according to EMC requirem<strong>en</strong>ts . . . . . . . . . . . . . . . . . . . . . . . . . 94<br />

Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

Mains connection / brake resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95<br />

Relay output connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97<br />

Function module mounting (optionally) . . . . . . . . . . . . . . . . . . . . . . . . . 98<br />

<strong>motec</strong> assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99<br />

Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101<br />

Before switching on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101<br />

Selection of the correct operating mo<strong>de</strong> . . . . . . . . . . . . . . . . . . . . . . . . 102<br />

Parameter setting with the E<strong>82</strong>ZBB diagnosis terminal . . . . . . . . . . . . . . 104<br />

Linear V/f−characteristic control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105<br />

Vector control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107<br />

The most important co<strong>de</strong>s for commissioning . . . . . . . . . . . . . . . . . . . . 112<br />

Fault <strong>de</strong>tection and elimination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

Faulty drive behaviour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

Fault messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125<br />

70<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Safety instructions<br />

L<strong>en</strong>ze controllers<br />

1<br />

G<strong>en</strong>eral safety and application notes for L<strong>en</strong>ze controllers<br />

(According to: Low−Voltage Directive 73/23/EEC)<br />

G<strong>en</strong>eral<br />

L<strong>en</strong>ze controllers (<strong>fr</strong>equ<strong>en</strong>cy inverters, servo inverters, DC controllers) can<br />

inclu<strong>de</strong> live and rotating parts − <strong>de</strong>p<strong>en</strong>ding on their type of protection − during<br />

operation. Surfaces can be hot.<br />

Non−authorized removal of the required cover, inappropriate use, incorrect<br />

installation or operation, creates the risk of severe injury to persons or<br />

damage to material assets.<br />

For more <strong>de</strong>tailed information please see the docum<strong>en</strong>tation.<br />

All operations concerning transport, installation, and commissioning as well<br />

as maint<strong>en</strong>ance must be carried out by qualified, skilled personnel (IEC 364<br />

or CENELEC HD 384 or DIN VDE 0100 and IEC report 664 or DIN VDE 0110<br />

and national regulations for the prev<strong>en</strong>tion of acci<strong>de</strong>nts must be observed).<br />

According to this basic safety information qualified skilled personnel are<br />

persons who are familiar with the installation, assembly, commissioning,<br />

and operation of the product and who have the qualifications necessary for<br />

their occupation.<br />

Application as directed<br />

Drive controllers are compon<strong>en</strong>ts which are <strong>de</strong>signed for installation in<br />

electrical systems or machinery. They are not to be used as household<br />

appliances. They are int<strong>en</strong><strong>de</strong>d exclusively for professional and commercial<br />

purposes according to EN 61000−3−2. This docum<strong>en</strong>tation inclu<strong>de</strong>s<br />

information about the compliance with the limit values to EN 61000−3−2.<br />

Wh<strong>en</strong> installing the drive controllers in machines, commissioning (i.e.<br />

starting of operation as directed) is prohibited until it is prov<strong>en</strong> that the<br />

machine complies with the regulations of the EC Directive 98/37/EC<br />

(Machinery Directive); EN 60204 must be observed.<br />

Commissioning (i.e. starting of operation as directed) is only allowed wh<strong>en</strong><br />

there is compliance with the EMC Directive (89/336/EEC).<br />

The drive controllers meet the requirem<strong>en</strong>ts of the Low−Voltage Directive<br />

73/23/EEC. The harmonised standards of the series<br />

EN 50178/DIN VDE 0160 apply to the controllers.<br />

The technical data and information on the connection conditions must be<br />

obtained <strong>fr</strong>om the nameplate and the docum<strong>en</strong>tation. They must be<br />

observed in any case.<br />

Warning: The availability of controllers is restricted according to<br />

EN 61800−3. These products can cause radio interfer<strong>en</strong>ces in resi<strong>de</strong>ntial<br />

areas. In this case, special measures are required.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 71


1<br />

Safety instructions<br />

L<strong>en</strong>ze controllers<br />

Transport, storage<br />

Please observe the notes on transport, storage and appropriate handling.<br />

Observe the climatic conditions according to EN 50178.<br />

Installation<br />

The controllers must be installed and cooled according to the regulations<br />

giv<strong>en</strong> in the docum<strong>en</strong>tation.<br />

Ensure proper handling and avoid mechanical stress. Do not b<strong>en</strong>d any<br />

compon<strong>en</strong>ts and do not change any insulation distances during transport<br />

or handling. Do not touch any electronic compon<strong>en</strong>ts and contacts.<br />

Controllers contain electrostatically s<strong>en</strong>sitive compon<strong>en</strong>ts which can easily<br />

be damaged by inappropriate handling. Do not damage or <strong>de</strong>stroy any<br />

electrical compon<strong>en</strong>ts since this might <strong>en</strong>danger your health!<br />

Electrical connection<br />

Wh<strong>en</strong> working on live drive controllers, the applicable national regulations<br />

for the prev<strong>en</strong>tion of acci<strong>de</strong>nts (e.g. VBG 4) must be observed.<br />

The electrical installation must be carried out according to the appropriate<br />

regulations (e.g. cable cross−sections, fuses, PE connection). Additional<br />

information can be obtained <strong>fr</strong>om the docum<strong>en</strong>tation.<br />

The docum<strong>en</strong>tation contains information about installation in compliance<br />

with EMC (shielding, earthing, filters and cables). These notes must also be<br />

observed for CE−marked controllers. The manufacturer of the system or<br />

machine is responsible for the compliance with the required limit values<br />

<strong>de</strong>man<strong>de</strong>d by the EMC legislation.<br />

Operation<br />

If necessary, systems including controllers must be equipped with<br />

additional monitoring and protection <strong>de</strong>vices according to the<br />

corresponding standards (e.g. law on technical equipm<strong>en</strong>t, regulations for<br />

the prev<strong>en</strong>tion of acci<strong>de</strong>nts, etc.). If necessary, adapt the controllers to your<br />

application. Please observe the corresponding information giv<strong>en</strong> in the<br />

Instructions.<br />

After the controller has be<strong>en</strong> disconnected <strong>fr</strong>om the supply voltage, live<br />

compon<strong>en</strong>ts and power connection must not be touched immediately since<br />

capacitors could be charged. Please observe the corresponding notes on<br />

the controller.<br />

All covers and doors must be closed during operation.<br />

Note for UL−approved systems with integrated controllers: UL warnings<br />

are notes which apply to UL systems. The docum<strong>en</strong>tation contains special<br />

information about UL.<br />

72<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Safety instructions<br />

L<strong>en</strong>ze controllers<br />

Safe standstill −8−<br />

Variant V004 of the controller series 9300 and 9300 vector, variant x4x of the<br />

controller series <strong>82</strong>00 vector and axis module ECSxAxxx support the<br />

function "Safe standstill", protection against unint<strong>en</strong>tional restart,<br />

according to the requirem<strong>en</strong>ts of App<strong>en</strong>dix I, No. 1.2.7 of the EC Directive<br />

"Machinery" 98/37/EC, DIN EN 954−1 category 3 and DIN EN 1037. It is<br />

absolutely necessary to observe the information about the function "Safe<br />

standstill" in the corresponding docum<strong>en</strong>tation and instructions.<br />

Maint<strong>en</strong>ance and service<br />

The controllers do not require any maint<strong>en</strong>ance, if the application conditions<br />

prescribed are observed.<br />

In operating areas with polluted ambi<strong>en</strong>t air, the cooling surfaces of the<br />

controller can get dirty or the cooling op<strong>en</strong>ings can block. Un<strong>de</strong>r these<br />

conditons a regular cleaning of the cooling surfaces and cooling op<strong>en</strong>ings<br />

is ess<strong>en</strong>tial. Do not use sharp or pointed objects for this purpose!<br />

Disposal<br />

Recycle metals and plastics. Dispose of printed circuit board assemblies<br />

according to the state of the art.<br />

The product−specific safety and application notes in these Instructions<br />

must also be observed!<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 73


1<br />

Safety instructions<br />

Three−phase AC machines<br />

G<strong>en</strong>eral safety and application notes for L<strong>en</strong>ze motors<br />

(to: Low−Voltage Directive 73/23/EEC)<br />

G<strong>en</strong>eral<br />

Low−voltage machines have dangerous, live and rotating parts as well as<br />

possibly hot surfaces. All operations serving transport, connection,<br />

commissioning and maint<strong>en</strong>ance are to be carried out by qualified, skilled<br />

personnel (observe EN 50110−1 (VDE 0105−100); IEC 60364). Improper<br />

handling may cause severe injury to persons or damage to material assets.<br />

Synchronous machines induce voltages at op<strong>en</strong> terminals during operation.<br />

Application as directed<br />

These low−voltage machines are int<strong>en</strong><strong>de</strong>d for industrial and commercial<br />

installations. They comply with the harmonized standards of the EN60034<br />

(VDE O53O) series. Their use in hazardous areas is prohibited unless they<br />

are expressly int<strong>en</strong><strong>de</strong>d for such use (follow additional instructions).<br />

Degrees of protection IP23 are only int<strong>en</strong><strong>de</strong>d for outdoor use wh<strong>en</strong><br />

applying special protective measures. Air−cooled <strong>de</strong>signs are rated for<br />

ambi<strong>en</strong>t temperatures <strong>fr</strong>om −15 °C and −10 °C to +40 °C and altitu<strong>de</strong>s 1000<br />

m a.m.s.l., <strong>fr</strong>om −20 °C to +40 °C without brake or with spring−operated<br />

brake, non−v<strong>en</strong>tilated or with integral fan, <strong>fr</strong>om −15 °C to +40 °C with<br />

perman<strong>en</strong>t magnet brake and <strong>fr</strong>om −10 °C to +40 °C with separate fan.<br />

Check indications on the nameplate and if they are differ<strong>en</strong>t, observe them.<br />

The conditions on site must correspond to all nameplate data.<br />

Low−voltage machines are compon<strong>en</strong>ts for the installation into machines as<br />

<strong>de</strong>fined in the Machinery Directive 98/37/EC. Commissioning is prohibited<br />

until the conformity of the <strong>en</strong>d product with this Directive has be<strong>en</strong><br />

established (follow a.o. EN 60204−1).<br />

The integrated brakes cannot be used as safety brakes. It cannot be<br />

guaranteed that factors which cannot be influ<strong>en</strong>ced, such as oil ingression<br />

because of a <strong>de</strong>fective A−si<strong>de</strong> shaft seal, do not cause a torque reduction.<br />

Transport, storage<br />

The forwar<strong>de</strong>r must be informed directly after receipt of the goods about all<br />

damages or <strong>de</strong>fici<strong>en</strong>cies; if necessary, commissioning must be stopped.<br />

Tight<strong>en</strong> screwed−in ring bolts before transport. They are <strong>de</strong>signed for the<br />

weight of the low−voltage machine, do not apply extra loads. If necessary,<br />

use suitable and a<strong>de</strong>quately dim<strong>en</strong>sioned means of transport (e.g. rope<br />

gui<strong>de</strong>s).<br />

Remove the shipping braces before commissioning. Reuse them for further<br />

transports. For storage of low−voltage machines <strong>en</strong>sure a dry, dust−<strong>fr</strong>ee and<br />

low−vibration (v rms 0.2 mm/s) <strong>en</strong>vironm<strong>en</strong>t (damage while being stored).<br />

Measure the insulation resistance before commissioning. If the values are <br />

1 k per volt of rated voltage, dry the winding.<br />

74<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Safety instructions<br />

Three−phase AC machines<br />

Installation<br />

Ensure an ev<strong>en</strong> surface, solid foot or flange mounting and exact alignm<strong>en</strong>t<br />

if a direct clutch is connected. Avoid resonances with the rotational<br />

<strong>fr</strong>equ<strong>en</strong>cy and double mains <strong>fr</strong>equ<strong>en</strong>cy which may be caused during<br />

assembly. Turn rotor by hand, list<strong>en</strong> for unusual slipping noises. Check the<br />

direction of rotation wh<strong>en</strong> the clutch is not active (observe section 5).<br />

Use appropriate tools to mount or remove belt pulleys and clutches (heat<br />

g<strong>en</strong>eration!) and cover them with a touch guard. Impermissible belt t<strong>en</strong>sions<br />

must be avoi<strong>de</strong>d (technical list).<br />

The machines are half−key balanced. The clutch must be half−key balanced,<br />

too. The visible outstanding part of the key must be removed.<br />

If required, provi<strong>de</strong> pipe connections. Designs with shaft <strong>en</strong>d at bottom must<br />

be protected with a cover which prev<strong>en</strong>ts the ingression of foreign particles<br />

into the fan. Free circulation of the cooling air must be <strong>en</strong>sured. The exhaust<br />

air − also the exhaust air of other machines next to the drive system − must<br />

not be tak<strong>en</strong> in again immediately.<br />

Electrical connection<br />

All operations must only be carried out by qualified and skilled personnel<br />

wh<strong>en</strong> the low−voltage machine is at standstill and wh<strong>en</strong> the machine is<br />

<strong>de</strong>−<strong>en</strong>ergized and protected against unint<strong>en</strong>tional restart. This also applies<br />

to auxiliary circuits (e.g. brake, <strong>en</strong>co<strong>de</strong>r, separate fan).<br />

Check safe isolation <strong>fr</strong>om the supply!<br />

If the tolerances in EN 60034−1; IEC 34 (VDE 0530−1) − voltage ±5 %,<br />

<strong>fr</strong>equ<strong>en</strong>cy ±2 %, wave form, symmetry − are excee<strong>de</strong>d, more heat will be<br />

g<strong>en</strong>erated and the electromagnetic compatibility will be influ<strong>en</strong>ced.<br />

Observe the indications on the nameplate, operating notes, and the<br />

connection diagram in the terminal box.<br />

The connection must <strong>en</strong>sure a continuous and safe electrical supply (no<br />

loose wire <strong>en</strong>ds); use appropriate cable terminals. The connection to the PE<br />

conductor must be safe. The plug−in connector must be bolt tightly (to stop).<br />

The clearances betwe<strong>en</strong> blank, live parts and earth must not fall below 8 mm<br />

at V r 550 V, 10 mm at V r 725 V, 14 mm at V r 1000 V.<br />

The terminal box must be clean and dry; foreign particles, dirt and moisture<br />

disturb operation. All unused cable <strong>en</strong>tries and the box itself must be sealed<br />

against dust and water. For the trial run without output elem<strong>en</strong>ts, lock the<br />

key. Check brake operation before commissioning of low−voltage machines<br />

with brakes.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 75


1<br />

Safety instructions<br />

Three−phase AC machines<br />

Operation<br />

Vibration severities v rms 3.5 mm/s (P r 15 <strong>kW</strong>) and 4.5 mm/s (P r > 15 <strong>kW</strong>)<br />

are acceptable wh<strong>en</strong> the clutch is activated. If <strong>de</strong>viations <strong>fr</strong>om normal<br />

operation occur, e.g. increased temperatures, noises, vibrations, find the<br />

cause and, if necessary, contact the manufacturer. Switch off the machine<br />

in problematic situations.<br />

If the drive is exposed to dirt, clean it regularly.<br />

Do not switch off the protection <strong>de</strong>vices, not ev<strong>en</strong> for trial runs.<br />

Integrated temperature s<strong>en</strong>sors do not provi<strong>de</strong> full protection. If necessary,<br />

limit the maximum curr<strong>en</strong>t. Connect the function blocks such that the<br />

machine switches off after several seconds of operation at I > I r , especially<br />

if blocking may occur.<br />

Shaft seals and bearings have a limited service life.<br />

Regrease the bearings using the relubrication facility while the low−voltage<br />

machine is running. Observe the saponification number. If the grease drain<br />

hole is sealed with a plug (IP54 driv<strong>en</strong> <strong>en</strong>d; IP23 driv<strong>en</strong> <strong>en</strong>d and non−driv<strong>en</strong><br />

<strong>en</strong>d), remove the plug before commissioning. Seal the bore holes with<br />

grease. Replace the prelubricated bearings (2Z bearings) after approx.<br />

10,000 h − 20,000 h, at the latest however after 3 − 4 years. Observe the<br />

manufacturer’s instructions.<br />

76<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Safety instructions<br />

Residual hazards, layout of safety instructions<br />

1<br />

Residual hazards<br />

Protection of persons<br />

Disconnect the controller before you start working on it/op<strong>en</strong> it and<br />

wait for at least 3 minutes since the power terminals U, V, W; BR0,<br />

BR1, BR2 and pins of the FIF interface remain live for this time.<br />

– After you have op<strong>en</strong>ed the <strong>motec</strong> check whether the power<br />

terminals L1, L2, L3; U, V, W; BR0, BR1, BR2, relay outputs K11,<br />

K12, K14 and pins of the FIF interface are not live any more.<br />

– Ev<strong>en</strong> if the controller is disconnected <strong>fr</strong>om the mains, the relay<br />

outputs K11, K12, K14 can carry dangerous voltage!<br />

<br />

If you use the not op<strong>en</strong>−circuit protected function Selection of<br />

direction of rotation" via the digital signal CW/CCW (C0007 = −0− ...<br />

−13−, C0410/3 255):<br />

– In the ev<strong>en</strong>t of an op<strong>en</strong> circuit or failure of the control voltage, the<br />

drive can change its direction of rotation.<br />

<br />

If you use the function "Flying−restart circuit" (C0142 = −2−, −3−) with<br />

machines with a low mom<strong>en</strong>t of inertia and a minimum <strong>fr</strong>iction:<br />

– After controller <strong>en</strong>able in standstill, the motor can start for a short<br />

time or change its direction of rotation for a short time.<br />

<br />

The <strong>motec</strong> heatsink temperature is > 60 °C:<br />

– Direct skin contact with the heatsink results in burnings.<br />

Motor protection<br />

Dep<strong>en</strong>ding on the controller settings, the connected motor can be<br />

overheated:<br />

– For instance, longer DC−braking operations.<br />

– Longer operation of self−v<strong>en</strong>tilated motors at low speed.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 77


1<br />

Safety instructions<br />

Residual hazards, layout of safety instructions<br />

Controller/system protection<br />

<br />

<br />

Drives can reach dangerous overspeeds (e.g. setting of<br />

inappropriately high field <strong>fr</strong>equ<strong>en</strong>cies):<br />

– The controllers do not offer any protection against these operating<br />

conditions. For this, use additional compon<strong>en</strong>ts.<br />

Contactors in the motor cable Switching with inhibited controller<br />

only.<br />

If contactors in the motor cable are switched with the controller <strong>en</strong>abled,<br />

– monitoring functions of the controller can be activated.<br />

– the controller can be <strong>de</strong>stroyed un<strong>de</strong>r unfavourable operating<br />

conditions.<br />

Warnings!<br />

The <strong>de</strong>vice has no overspeed protection.<br />

Must be provi<strong>de</strong>d with external or remote overload protection.<br />

Suitable for use on a circuit capable of <strong>de</strong>livering not more<br />

than 5000 rms symmetrical amperes, 240 V maximum (240 V<br />

<strong>de</strong>vices) or 500 V maximum (400/500 V <strong>de</strong>vices) resp.<br />

Circuit breakers (either inverse−time or instantaneous trip<br />

types) may be used in lieu of above fuses wh<strong>en</strong> it is shown<br />

that the let−through <strong>en</strong>ergy (I 2 t) and peak let−through curr<strong>en</strong>t<br />

(Ip) of the inverse−time curr<strong>en</strong>t−limiting circuit breaker will be<br />

less than that of the non−semiconductor type K5 fuses with<br />

which the drive has be<strong>en</strong> tested. An inverse−time circuit<br />

breaker may be used, sized upon the input rating of the drive,<br />

multiplied by 300 %.<br />

Use 60/75 °C or 75 °C copper wire only.<br />

If mounted on a motor the <strong>en</strong>vironm<strong>en</strong>tal rating tests for<br />

Type 4 and Type 12 shall be performed.<br />

78<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Safety instructions<br />

Residual hazards, layout of safety instructions<br />

Layout of the safety instructions<br />

All safety information giv<strong>en</strong> in these Instructions has the same layout:<br />

Pictograph (indicates the type of danger)<br />

Signal word! (indicates the severity of danger)<br />

Note (<strong>de</strong>scribes the danger and explains how to avoid it)<br />

Pictograph Signal word Possible consequ<strong>en</strong>ces if<br />

the safety information is<br />

Signal word<br />

Meaning<br />

disregar<strong>de</strong>d<br />

<br />

Dangerous electrical<br />

voltage<br />

<br />

G<strong>en</strong>eral danger<br />

<br />

<br />

Danger! Imp<strong>en</strong>ding danger for persons Death or most severe<br />

injuries<br />

Warning!<br />

Caution!<br />

Possible, very dangerous<br />

situation for persons<br />

Possible, dangerous situation<br />

for persons<br />

Death or most severe<br />

injuries<br />

Injuries<br />

1<br />

Stop! Possible material damage Damage of the drive<br />

system or its surroundings<br />

Note! Useful note or tip<br />

If you observe it, handling of the<br />

drive system will be easier.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 79


2<br />

Technical data<br />

Standards and application conditions<br />

Conformity CE Low−Voltage Directive (73/23/EEC)<br />

Approvals UL 508C Un<strong>de</strong>rwriter Laboratories (File−No. E132659)<br />

Power Conversion Equipm<strong>en</strong>t<br />

Vibration resistance Acceleration resistant up to 2g (Germanischer Lloyd, g<strong>en</strong>eral conditions)<br />

Climatic conditions Class 3K3 to EN 50178 (without con<strong>de</strong>nsation, average relative humidity 85<br />

%)<br />

Permissible<br />

transport −25 °C ... +70 °C<br />

temperature ranges<br />

storage −25 °C ... +60 °C<br />

operation −20 °C ... +60 °C<br />

reduce the rated output curr<strong>en</strong>t by 2.5%/°C above +40 °C<br />

Permissible installation<br />

height<br />

Mounting positions<br />

Freee space above 100 mm<br />

to the 100 mm<br />

si<strong>de</strong>s<br />

0 ... 4000 m amsl<br />

reduce the rated output curr<strong>en</strong>t by 5%/1000 m above 1000 m amsl<br />

Any mouning position is possible<br />

80<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Technical data<br />

G<strong>en</strong>eral electrical data<br />

2<br />

G<strong>en</strong>eral technical data<br />

EMC7.<br />

Compliance with EN 61800−3/A11<br />

Noise emission Motor mounting Compliance with limit value classes A and B to<br />

EN 55011<br />

Wall mounting Compliance with limit value class A to EN<br />

55011<br />

(up to 10 m shiel<strong>de</strong>d motor cable)<br />

Compliance with limit value class B to EN<br />

55011<br />

(up to 1 m shiel<strong>de</strong>d motor cable)<br />

Discharge curr<strong>en</strong>t to PE > 3.5 mA<br />

(to EN 50178)<br />

Enclosure8. IP 55<br />

without protection cover over AIF interface<br />

(NEMA 250 Type 12)<br />

IP 65<br />

with protection cover over AIF interface<br />

(NEMA 250 Type 4)<br />

Protection measures against Short circuit, earth fault (earth−fault protected during operation, limited<br />

earth−fault protection during power up), overvoltage, motor stalling, motor<br />

overtemperature (input for PTC thermistor or thermostat (NC contact), I 2 t<br />

monitoring)<br />

Insulation of control circuits Safe mains disconnection:<br />

Double/reinforced insulation to EN 50178<br />

Operation at public mains<br />

(limitation of harmonic<br />

curr<strong>en</strong>ts according to EN<br />

61000−3−2)<br />

Total power connected Compliance with the requirem<strong>en</strong>ts 1)<br />

to the mains<br />

0.25 <strong>kW</strong> ... 0.75 <strong>kW</strong> With mains choke<br />

> 1 <strong>kW</strong> without additional measures<br />

1) The additional measures <strong>de</strong>scribed only <strong>en</strong>sure that the controllers meet the requirem<strong>en</strong>ts<br />

of the EN 61000−3−2. The machine/system manufacturer is responsible for the compliance<br />

with the regulations of the machine!<br />

Operation at rated power<br />

Typical motor power P r [KW] <strong>0.55</strong> 0.75 1.5 <strong>2.2</strong><br />

<strong>82</strong>00 <strong>motec</strong> Type E<strong>82</strong>MV551_4B E<strong>82</strong>MV751_4B E<strong>82</strong>MV152_4B E<strong>82</strong>MV222_4B<br />

Mains voltage range<br />

V r [V]<br />

3/PE AC; 320 V − 0 % ... 550 V + 0 %<br />

(45 Hz − 0 % ... 65 Hz + 0 %)<br />

Data for operation with 3 PE AC 400 V 400 V 400 V 400 V<br />

Rated mains curr<strong>en</strong>t I r [A] 1.8 2.4 3.8 5.5<br />

Output curr<strong>en</strong>t 8 kHz * I r8 [A] 1.8 2.4 3.9 5.6<br />

Max. permissible output<br />

curr<strong>en</strong>t for 60 s<br />

* Inverter chopper <strong>fr</strong>equ<strong>en</strong>cy<br />

8 kHz * I max8 [A] 2.7 3.6 5.8 8.4<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 81


2<br />

Technical data<br />

Dim<strong>en</strong>sions, mechanical <strong>de</strong>sign<br />

Dim<strong>en</strong>sions<br />

c<br />

b<br />

a<br />

f<br />

d<br />

e<br />

<strong>82</strong>00mot001<br />

Type a [mm] b [mm] c [mm] d [mm] e [mm] f [mm]<br />

E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Mechanical <strong>de</strong>sign<br />

156 151 135 202 15 26<br />

176 167 151 230 15 26<br />

Type Cable connections Weight<br />

E<strong>82</strong>MV551_4B 2 M25 (thread l<strong>en</strong>gth 10 mm, without counter nut)<br />

E<strong>82</strong>MV751_4B 4 M16 (thread l<strong>en</strong>gth 10 mm, without counter nut)<br />

1 M20 for motor cables for wall mounting (EMC cable connection,<br />

2.8 kg<br />

thread l<strong>en</strong>gth 10 mm, with counter nut)<br />

E<strong>82</strong>MV152_4B 1 M20 (thread l<strong>en</strong>gth 10 mm, without counter nut)<br />

E<strong>82</strong>MV222_4B 2 M25 (thread l<strong>en</strong>gth 10 mm, without counter nut)<br />

4 M16 (thread l<strong>en</strong>gth 10 mm, without counter nut)<br />

4.1 kg<br />

1 M20 for motor cables for wall mounting (EMC cable connection,<br />

thread l<strong>en</strong>gth 10 mm, with counter nut)<br />

<strong>82</strong><br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


<strong>motec</strong> with motor or geared motor<br />

Mounting<br />

3<br />

Danger!<br />

After the connection of a PTC thermistor or thermal contact<br />

all control terminals only have a basic insulation (single<br />

insulating distance).<br />

Protection against contact in the ev<strong>en</strong>t of a <strong>de</strong>fective<br />

insulating distance can only be <strong>en</strong>sured by external measures<br />

(e.g. double insulation).<br />

1b<br />

1a<br />

1a<br />

Fig. 12<br />

X1<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

1a<br />

<strong>82</strong>00mot002<br />

95<br />

Activate motor temperature monitoring with C0119 (e. g. C0119 = 1)!<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 83


3<br />

<strong>motec</strong> with motor or geared motor<br />

Wiring according to EMC requirem<strong>en</strong>ts<br />

Conditions for trouble−<strong>fr</strong>ee operation:<br />

<br />

<br />

<br />

Except for the mains cable, use shiel<strong>de</strong>d cables only.<br />

The shield must be carefully connected to PE.<br />

Connect motor and mains PE conductors to separate PE terminals.<br />

X1<br />

Shield connection<br />

1. Prepare cable<br />

A<br />

B<br />

F<br />

2. Route the cable<br />

through the eyebolt<br />

of the shield and<br />

b<strong>en</strong>d the eyebolt.<br />

C<br />

D<br />

E<br />

3. Tight<strong>en</strong> the screw.<br />

The shield must be<br />

tightly connected to<br />

the shield sheet.<br />

0.7 Nm<br />

6 lb-in<br />

<strong>82</strong>00mot101<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

PES<br />

Mains cable L1, L2, L3, PE<br />

PE connection − mains cable<br />

Shiel<strong>de</strong>d control cable<br />

Shield connection for control cable (screw shield to shield sheet)<br />

Function module<br />

Isolated terminal (e. g. star point for motor star connection)<br />

Terminal strip − mains connection<br />

HF shield connection by connecting the shield with a surface as large as possible to PE<br />

84<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Wall mounting<br />

Delivery package<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Fig. 13<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Carrier housing<br />

1b Electronic module<br />

2a Gasket<br />

3 Distance and wall mounting board<br />

4a Wall mounting cover<br />

4b Wall mounting screws<br />

5a Shield sheet<br />

5b Shield sheet screws (for mounting the shield to the sheet)<br />

X1 Terminal strip mains connection, relay, brake resistor<br />

X2 Terminal strip motor connection, PTC thermistor or thermal contact (NC contact)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 85


3<br />

Wall mounting<br />

Preparations<br />

a<br />

c<br />

b<br />

3<br />

4a<br />

2a<br />

d<br />

1 ×M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 ×M25<br />

4 ×M16<br />

Fig. 14<br />

5.3 mm<br />

3 3<br />

A<br />

1 ×M20<br />

1a<br />

1a<br />

e<br />

3<br />

2a<br />

5a<br />

<strong>82</strong>00mot004<br />

1a<br />

4b<br />

3.4Nm<br />

30 lb-in<br />

Cable connection of metal for the motor cable (e. g. EMC cable connection)<br />

86<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Wall mounting<br />

Preparations<br />

Distance and wall mounting board Drilling pattern Distance<br />

a [mm] b [mm] c [mm] d [mm] e [mm]<br />

85 152 61 120 26<br />

85 172 61 140 26<br />

3<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 87


3<br />

Wall mounting<br />

Motor connection<br />

Danger!<br />

After the connection of a PTC thermistor or thermal contact<br />

all control terminals only have a basic insulation (single<br />

insulating distance).<br />

Protection against contact in the ev<strong>en</strong>t of a <strong>de</strong>fective<br />

insulating distance can only be <strong>en</strong>sured by external measures<br />

(e.g. double insulation).<br />

X2 T1 T2 PE W V U<br />

X2<br />

T1 T2<br />

PE<br />

W V U<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

T1<br />

T2<br />

<br />

PE<br />

5.5 mm<br />

2.5 mm<br />

2<br />

AWG 12<br />

6mm<br />

X2<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

1a<br />

B<br />

A<br />

3.4 Nm<br />

30 lb-in<br />

Fig. 15<br />

3.4 Nm<br />

30 lb-in<br />

<strong>82</strong>00mot006<br />

1a<br />

<br />

Use low−capacity motor cables! (Core/core 75 pF/m, core/shield 150 pF/m)<br />

Use short motor cables if possible!<br />

Cable cross−sections U, V, W, PE:<br />

E<strong>82</strong>MV551_4B, E<strong>82</strong>MV751_4B 1 mm 2 (AWG 18), shiel<strong>de</strong>d<br />

E<strong>82</strong>MV222_4B, E<strong>82</strong>MV152_4B 1.5 mm 2 (AWG 16), shiel<strong>de</strong>d<br />

Route a separate cable (shiel<strong>de</strong>d) to X2/T1 and X2/T2 for the motor temperature monitoring.<br />

Route the control and mains cables separately <strong>fr</strong>om the motor cable!<br />

88<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


V<br />

Wall mounting<br />

Motor connection<br />

3<br />

X2<br />

T1<br />

T2 PE W<br />

U<br />

PES<br />

PES<br />

PES<br />

PE<br />

<br />

M<br />

3~<br />

PES<br />

PTC<br />

M<br />

3~<br />

95<br />

<strong>82</strong>00mot168<br />

PES HF shield connection by PE connection to the shield ( 90 ) or motor EMC connection.<br />

X2/T1, Connection terminals motor temperature monitoring with PTC thermistor or thermal contact (NC<br />

X2/T2 contact).<br />

Activate motor temperature monitoring with C0119 (e. g. C0119 = 1)!<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 89


3<br />

Wall mounting<br />

Wiring according to EMC requirem<strong>en</strong>ts<br />

Conditions for trouble−<strong>fr</strong>ee operation:<br />

<br />

<br />

<br />

<br />

A<br />

C<br />

F<br />

Except for the mains cable, use shiel<strong>de</strong>d cables only.<br />

The shield must be carefully connected to PE.<br />

Separate control and mains cables <strong>fr</strong>om motor cable!<br />

Connect motor and mains PE conductors to separate PE terminals.<br />

D<br />

B<br />

E<br />

G<br />

X1<br />

J<br />

X2<br />

H<br />

I<br />

Shield connection<br />

1. Prepare cable<br />

2. Route the cable through<br />

the eyebolt of the shield<br />

and b<strong>en</strong>d the eyebolt.<br />

3. Tight<strong>en</strong> the screw. The<br />

shield must be tightly<br />

connected to the shield<br />

sheet.<br />

0.7 Nm<br />

6 lb-in<br />

Fig. 16<br />

<strong>82</strong>00mot100<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

X2<br />

PES<br />

90<br />

Mains cable L1, L2, L3, PE<br />

PE connection − mains cable<br />

Use shiel<strong>de</strong>d motor cable (use low capacity motor cables)<br />

EMC cable connection for motor cables<br />

PE connection − motor cable<br />

Shiel<strong>de</strong>d control cable<br />

Shield connection for control cable (screw shield to shield sheet)<br />

PE connection − terminal strip X2<br />

Isolated terminal (e.g. star point for motor star connection)<br />

Function module<br />

Terminal strip − mains connection<br />

Terminal strip − motor connection<br />

HF shield connection by connecting the shield with a surface as large as possible to PE<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Motor mounting<br />

Delivery package<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Fig. 17<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Carrier housing<br />

1b Electronic module<br />

2a Gasket<br />

3 Distance and wall mounting board<br />

4a Wall mounting cover<br />

4b Wall mounting screws<br />

5a Shield sheet<br />

5b Shield sheet screws (for mounting the shield to the sheet)<br />

X1 Terminal strip mains connection, relay, brake resistor<br />

X2 Terminal strip motor connection, PTC thermistor or thermal contact (NC contact)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 91


3<br />

Motor mounting<br />

Preparations<br />

<br />

68-73mm<br />

68-73mm<br />

3.4 Nm<br />

30 lb-in<br />

5mm<br />

<br />

<br />

5a<br />

1a<br />

Fig. 18<br />

2a<br />

<br />

3<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/<br />

E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

2a<br />

1a<br />

<strong>82</strong>00mot007<br />

Preparing the motor:<br />

Terminal box seal and motor terminal board must be removed.<br />

If necessary, ext<strong>en</strong>d the motor cable.<br />

Mount the housing base to the motor:<br />

The mounting and fixing must <strong>en</strong>sure a perman<strong>en</strong>tly tight mechanical connection. (DIN 6798).<br />

If distance required: Use (2a), (3) and screw 35mm (DIN 7985) (without : only screw 20 mm (DIN<br />

7985))<br />

Perfect sealing is required to <strong>en</strong>sure <strong>en</strong>closure IP65.<br />

92<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


5.5 mm<br />

Motor mounting<br />

Motor connection<br />

3<br />

Danger!<br />

After the connection of a PTC thermistor or thermal contact<br />

all control terminals only have a basic insulation (single<br />

insulating distance).<br />

Protection against contact in the ev<strong>en</strong>t of a <strong>de</strong>fective<br />

insulating distance can only be <strong>en</strong>sured by external measures<br />

(e.g. double insulation).<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

W2 U2 V2<br />

2.5 mm<br />

2<br />

AWG 12<br />

X2<br />

T1<br />

T1 T2 PE W<br />

T2<br />

V<br />

U<br />

U1 V1 W1 PE<br />

6mm<br />

PE<br />

<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

X2<br />

Fig. 19<br />

3.4 Nm<br />

30 lb-in<br />

3.4 Nm<br />

30 lb-in<br />

1a<br />

T1 T2 PE W V U<br />

<strong>82</strong>00mot008<br />

1a<br />

X2/T1,<br />

X2/T2<br />

Connection terminals motor temperature monitoring with PTC thermistor or thermal contact (NC<br />

contact).<br />

Activate motor temperature monitoring with C0119 (e. g. C0119 = 1)!<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 93


3<br />

Motor mounting<br />

Wiring according to EMC requirem<strong>en</strong>ts<br />

Conditions for trouble−<strong>fr</strong>ee operation:<br />

<br />

<br />

<br />

Except for the mains cable, use shiel<strong>de</strong>d cables only.<br />

The shield must be carefully connected to PE.<br />

Connect motor and mains PE conductors to separate PE terminals.<br />

A<br />

B<br />

C<br />

X1<br />

X2<br />

F<br />

G<br />

Shield connection<br />

1. Prepare cable<br />

2. Route the cable<br />

through the eyebolt<br />

of the shield and<br />

b<strong>en</strong>d the eyebolt.<br />

D<br />

E<br />

H<br />

3. Tight<strong>en</strong> the screw.<br />

The shield must be<br />

tightly connected to<br />

the shield sheet.<br />

0.7 Nm<br />

6 lb-in<br />

Fig. 20<br />

<strong>82</strong>00mot101<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

X2<br />

PES<br />

Mains cable L1, L2, L3, PE<br />

PE connection − mains cable<br />

PE connection − motor<br />

Shiel<strong>de</strong>d control cable<br />

Shield connection for control cable (screw shield to shield sheet)<br />

PE connection − terminal strip X2<br />

Isolated terminal (e.g. star point for motor star connection)<br />

Function module<br />

Terminal strip − mains connection<br />

Terminal strip − motor connection<br />

HF shield connection by connecting the shield with a surface as large as possible to PE<br />

94<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Electrical installation<br />

Mains connection / brake resistor<br />

4<br />

Stop!<br />

Discharge curr<strong>en</strong>t against earth 3.5 mA. According to<br />

EN 50178 perman<strong>en</strong>t fixed installation is required. The PE<br />

connection must be carried out in accordance with EN 50178.<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

5.5 mm<br />

PE<br />

L3 L2 L1 BR2 BR1 BR0 K14 K12 K11<br />

2.5 mm 2<br />

AWG 12<br />

6 mm<br />

K14 K12 K11<br />

97<br />

Fig. 21<br />

A<br />

BR2 BR1 BR0<br />

R B<br />

1a<br />

3.4 Nm<br />

30 lb-in<br />

3/PE AC 320...550V 45...65Hz<br />

L1<br />

L2<br />

L3<br />

PE<br />

F1<br />

K1<br />

<strong>82</strong>00mot009<br />

X1<br />

L3 L2<br />

L1<br />

<br />

R B = Brake resistor (accessories)<br />

R B 450 (E<strong>82</strong>MV551/E<strong>82</strong>MV751)<br />

R B 200 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 95


4<br />

Electrical installation<br />

Mains connection / brake resistor<br />

Fuses and cable cross−sections<br />

Type mains Installation to EN 60204−1 Installation to UL 1) FI 2)<br />

Fuse E.l.c.b. L1, L2, L3, PE<br />

[mm 2 ]<br />

Fuse<br />

L1, L2, L3, PE<br />

[AWG]<br />

E<strong>82</strong>MV551_4B<br />

M6 A B6 A 1 5 A 18<br />

E<strong>82</strong>MV751_4B 3/PE AC M6 A B6 A 1 5 A 18<br />

320 ... 550 V;<br />

E<strong>82</strong>MV152_4B M6 A B6 A 1 5 A 18<br />

45 ... 65 Hz<br />

E<strong>82</strong>MV222_4B M10 A B10 A 1.5 10 A 16<br />

30 mA<br />

1) Use UL−approved cables, fuses and fuse hol<strong>de</strong>rs only.<br />

UL fuse: 500 ... 600 V, tripping characteristic "H", "K5" or "CC"<br />

2) Pulse−curr<strong>en</strong>t or universal−curr<strong>en</strong>t s<strong>en</strong>sitive earth leakage circuit breaker<br />

Observe national and regional regulations<br />

Please observe the following wh<strong>en</strong> using e.l.c.bs.:<br />

E.l.c.bs must only be installed betwe<strong>en</strong> mains supply and controller.<br />

Earth leakage circuit breakers can be activated although not required<br />

by<br />

– capacitive leakage curr<strong>en</strong>ts of the cable shields during operation<br />

(especially with long, shiel<strong>de</strong>d motor cables),<br />

– simultaneous connection of several controllers to the mains supply.<br />

<strong>82</strong>00 <strong>motec</strong> in parallel connection<br />

Type<br />

E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Mains<br />

curr<strong>en</strong>t<br />

1.8 A<br />

2.4 A<br />

3.8 A<br />

5.5 A<br />

Mains contactor required for connection of:<br />

1 <strong>motec</strong> 2 <strong>motec</strong> 3 <strong>motec</strong> 4 <strong>motec</strong> 5 <strong>motec</strong> 6 <strong>motec</strong><br />

4 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1)<br />

4 <strong>kW</strong> 2) 5.5 <strong>kW</strong> 2) 7.5 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2)<br />

The sum of mains curr<strong>en</strong>ts must not exceed 23mA!<br />

1) Mains contactor <strong>de</strong>termined by inrush curr<strong>en</strong>ts.<br />

IMPORTANT<br />

2) Mains contactor for operation with mains choke 1.5 mH/24 A (or<strong>de</strong>r No.<br />

ELN3−0150H024) or curr<strong>en</strong>t limitation module E<strong>82</strong>ZJ004 (max. 20 A/phase).<br />

Observe national and regional regulations<br />

96<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Electrical installation<br />

Relay output connection<br />

4<br />

<strong>82</strong>00 <strong>motec</strong><br />

X1<br />

K14 K12 K11 X1<br />

Fig. 22<br />

PES<br />

1a<br />

PES<br />

<strong>82</strong>00mot148<br />

Function<br />

Relay position<br />

set<br />

Message<br />

(L<strong>en</strong>ze setting)<br />

Technical data<br />

X1/K11 NC contact relay output op<strong>en</strong> TRIP<br />

AC 250 V/3 A<br />

X1/K12 Relay middle contact<br />

DC 24 V/2 A ... DC 240 V/0.22 A<br />

X1/K14 NO contact relay output closed TRIP<br />

PES HF scre<strong>en</strong> termination by PE connection with a surface as large as possible<br />

Note!<br />

For switching the control signals use shiel<strong>de</strong>d cables and<br />

establish an HF shield termination by PE connection.<br />

For mains pot<strong>en</strong>tial switching unshiel<strong>de</strong>d cables are<br />

suffici<strong>en</strong>t.<br />

With inductive or capacitive loads a corresponding protective<br />

circuit is required in or<strong>de</strong>r to protect the relay contacts!<br />

The service life of the relay <strong>de</strong>p<strong>en</strong>ds on the type of load<br />

(ohmic, inductive or capacitive) and the value of the switching<br />

capacity.<br />

The output message can be changed un<strong>de</strong>r C0008 or<br />

C0415/1.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 97


5<br />

Function module mounting (optionally)<br />

Stop!<br />

Shield control cables to avoid interfer<strong>en</strong>ces!<br />

Remove the FIF cover <strong>fr</strong>om the electronic module and the<br />

protection cover <strong>fr</strong>om the function module. Otherwise, the<br />

<strong>motec</strong> or the function module can be damaged.<br />

1<br />

klick<br />

2<br />

<br />

1a<br />

X3<br />

3<br />

<br />

4<br />

1a<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X3<br />

PES<br />

PES<br />

2<br />

1 mm<br />

AWG 18<br />

6mm<br />

<strong>82</strong>00mot147<br />

1b<br />

1. Fix the function module.<br />

2. Remove and keep the protection cover of the function module.<br />

3. Remove and keep the FIF cover !<br />

4. Wiring: see Mounting Instructions for the function module.<br />

98<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


<strong>motec</strong> assembly 6<br />

<strong>motec</strong> with function module<br />

Stop!<br />

Remove and keep the protection cover of the function<br />

module and the FIF cover before assembly! Otherwise,<br />

the <strong>motec</strong> can be damaged!<br />

Complete the <strong>motec</strong> nameplate with the sticker , which is<br />

<strong>de</strong>livered toegether with the function module, before<br />

commissioning.<br />

<br />

<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

Standard-I/O<br />

S<br />

<strong>82</strong>00mot059<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 99


<strong>motec</strong> without function module<br />

6 <strong>motec</strong> assembly<br />

Stop!<br />

FIF protection cover must be plugged on. Otherwise, the<br />

<strong>motec</strong> will not be ready for operation!<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 L<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

<strong>82</strong>00mot138<br />

100


Commissioning<br />

Before switching on<br />

7<br />

Note!<br />

Do not change the switch−on sequ<strong>en</strong>ce.<br />

In the ev<strong>en</strong>t of an error during commissioning please see the<br />

chapter "Fault <strong>de</strong>tection and elimination".<br />

Check the following to avoid damage to persons or material...<br />

...before the mains voltage is connected:<br />

Wiring for complet<strong>en</strong>ess, short circuit and earth fault<br />

"Emerg<strong>en</strong>cy−off" function of system<br />

Motor connection (star/<strong>de</strong>lta) must be adapted to output voltage of<br />

controller.<br />

If you do not use a function module <strong>en</strong>sure that the FIF cover is<br />

mounted properly (as <strong>de</strong>livered).<br />

If the internal voltage supply is connected, for instance, to X3/20 of<br />

the standard−I/O, terminals X3/7 and X3/39 must be bridged.<br />

... the most important drive parameter settings before the controller is<br />

<strong>en</strong>abled:<br />

Are the drive parameters relevant for your application set correctly?<br />

– e. g. configuration of analog and digital inputs and outputs<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 101


7 Commissioning<br />

Selection of the correct operating mo<strong>de</strong><br />

The control mo<strong>de</strong> of the controller can be selected via the operating mo<strong>de</strong>.<br />

You can select betwe<strong>en</strong><br />

V/f characteristic control<br />

Vector control<br />

S<strong>en</strong>sorless torque control<br />

Selection of the correct operating mo<strong>de</strong><br />

V/f characteristic control is the classic operating mo<strong>de</strong> for standard<br />

applications.<br />

The vector control provi<strong>de</strong>s better control features than the V/f characteristic<br />

control because of:<br />

a higher torque over the whole speed range<br />

higher speed accuracy and smooth running features<br />

higher effici<strong>en</strong>cy<br />

M<br />

<br />

<br />

M N<br />

n N<br />

n<br />

<br />

<br />

V/f characteristic control<br />

Vector control<br />

<strong>82</strong>00vec524<br />

Operating mo<strong>de</strong>s recomm<strong>en</strong><strong>de</strong>d for standard applications<br />

The following table helps you to find the correct operating mo<strong>de</strong> for standard<br />

applications:<br />

102<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

Selection of the correct operating mo<strong>de</strong><br />

7<br />

Application<br />

Single drives<br />

Operating mo<strong>de</strong><br />

Setting in C0014<br />

recomm<strong>en</strong><strong>de</strong>d<br />

alternatively<br />

with extremely alternating loads 4 2<br />

with heavy start conditions 4 2<br />

with speed control (speed feedback) 2 4<br />

with high dynamic response (e. g. positioning and infeed drives) 2 −<br />

with torque setpoint 5 −<br />

with torque limitation (power control) 2 4<br />

Three−phase AC reluctance motors 2 −<br />

Three−phase sliding rotor motors 2 −<br />

Three phase motors with assigned <strong>fr</strong>equ<strong>en</strong>cy−voltage characteristic 2 −<br />

Pump and fan drives with square−law load characteristic 3 2 or 4<br />

Group drives<br />

(several motors connected to controller)<br />

i<strong>de</strong>ntical motors and i<strong>de</strong>ntical loads 2 −<br />

differ<strong>en</strong>t motors and/or changing loads 2 −<br />

C0014 = 2: linear V/f characteristic control<br />

C0014 = 3: square−law V/F characteristic control<br />

C0014 = 4: vector control<br />

C0014 = 5: s<strong>en</strong>sorless torque control<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 103


7 Commissioning<br />

Parameter setting with the E<strong>82</strong>ZBB diagnosis terminal<br />

Description<br />

The diagnosis terminal is available as accessories. It consists of a rubber<br />

housing in which the E<strong>82</strong>ZBC keypad is mounted. For connecting it to the<br />

controller, a separate E<strong>82</strong>ZWL connection cable is required. A complete<br />

<strong>de</strong>scription of the keypad is inclu<strong>de</strong>d in the Instructions supplied together<br />

with the keypad.<br />

Connecting the diagnosis terminal<br />

Ev<strong>en</strong> during operation it is possible to connect the diagnosis terminal to the<br />

AIF interface of the controller and disconnect it again.<br />

As soon as the keypad is supplied with voltage, it carries out a self−test. The<br />

keypad is ready for operation, wh<strong>en</strong> it is in display mo<strong>de</strong>.<br />

104<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

Linear V/f−characteristic control<br />

The following instructions apply to controllers equipped with a standard−I/O<br />

function module and a three−phase AC motor which has be<strong>en</strong> selected<br />

accordingly.<br />

7<br />

1. Connect the keypad<br />

2. Ensure that controller inhibit is<br />

active after mains connection<br />

3. Switch on the mains<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Terminal X3/28 = LOW<br />

4. The keypad is in "Disp" mo<strong>de</strong><br />

after approx. 2 s and indicates<br />

the output <strong>fr</strong>equ<strong>en</strong>cy (C0050)<br />

<br />

PS 1<br />

<br />

<br />

0050<br />

Hi<br />

Lo<br />

000 000<br />

Hz<br />

misc002<br />

The m<strong>en</strong>u USEr is active<br />

5. Change to the mo<strong>de</strong> to <br />

<br />

<br />

<br />

configure the basic settings for<br />

<br />

your drive 000 000<br />

PS<br />

<br />

1<br />

<br />

0050<br />

Hi<br />

Hz<br />

Lo<br />

Blinking on the display:<br />

0050<br />

6. Adapt the voltage/curr<strong>en</strong>t range<br />

for the analog setpoint selection<br />

(C0034)<br />

L<strong>en</strong>ze setting: −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

Set the DIP switch on the<br />

standard I/O to the same<br />

range (see Mounting<br />

Instructions for the<br />

standard I/O)<br />

7. Adapt the terminal configuration<br />

to the wiring (C0007)<br />

L<strong>en</strong>ze setting: −0−, i. e.<br />

E1: JOG1/3 fixed setpoint<br />

selection<br />

E2: JOG2/3<br />

E3: DCB DC brake<br />

E4: CW/CCW rotation<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

8. Set the minimum output<br />

<strong>fr</strong>equ<strong>en</strong>cy (C0010)<br />

L<strong>en</strong>ze setting: 0.00 Hz<br />

[f]<br />

C0011<br />

9. Set the maximum output<br />

<strong>fr</strong>equ<strong>en</strong>cy (C0011)<br />

L<strong>en</strong>ze setting: 50.00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 105


7 Commissioning<br />

Linear V/f−characteristic control<br />

10. Set the acceleration time T ir<br />

(C0012)<br />

L<strong>en</strong>ze setting: 5.00 s<br />

11. Set the <strong>de</strong>celeration time T if<br />

(C0013)<br />

L<strong>en</strong>ze setting: 5.00 s<br />

12. Set the V/f−rated <strong>fr</strong>equ<strong>en</strong>cy<br />

(C0015)<br />

L<strong>en</strong>ze setting: 50.00 Hz<br />

B0 <br />

+ <br />

B<br />

B <br />

<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

V out<br />

100%<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = acceleration time<br />

wanted<br />

T if<br />

Н Н t if<br />

C0011<br />

f 2<br />

f 1<br />

t if = <strong>de</strong>celeration time<br />

wanted<br />

13. Set the V min boost (C0016)<br />

L<strong>en</strong>ze setting: Dep<strong>en</strong>ding on the<br />

controller type<br />

14. If you want to change the<br />

settings, please go to the m<strong>en</strong>u<br />

ALL<br />

V min<br />

0<br />

0 C0015<br />

Activate e.g. JOG <strong>fr</strong>equ<strong>en</strong>cies<br />

(C0037, C0038, C0039) or motor<br />

temperature monitoring (C0119)<br />

15. Go to the m<strong>en</strong>u ALL<br />

A Check the fan monitoring<br />

setting un<strong>de</strong>r co<strong>de</strong> C0608:<br />

– for <strong>82</strong>00 <strong>motec</strong> 0.25...0.37<br />

<strong>kW</strong> and <strong>0.55</strong>...<strong>2.2</strong> <strong>kW</strong>:<br />

C0608 = 0! (<strong>de</strong>fault setting)<br />

– for <strong>82</strong>00 <strong>motec</strong> 3...7.5 <strong>kW</strong>:<br />

C0608 =1 or C0608 = 2!<br />

Stop!<br />

Function must be<br />

activated during<br />

commissioning!<br />

Otherwise, the<br />

controller may be<br />

<strong>de</strong>stroyed through<br />

overheating!<br />

– for all other controllers:<br />

C0608 = 0 ! (<strong>de</strong>fault<br />

setting)<br />

B Select additional functions via<br />

co<strong>de</strong>s, if necessary.<br />

Wh<strong>en</strong> all settings are complete:<br />

16. Select the setpoint E.g. via pot<strong>en</strong>tiometer at<br />

terminals 7, 8, 9<br />

17. Enable the controller<br />

X3<br />

20 28<br />

f<br />

misc002<br />

The L<strong>en</strong>ze setting is<br />

suitable for all common<br />

applications<br />

Terminal X3/28 = HIGH<br />

18. The drive should now be running. If the drive does not<br />

start, press in<br />

addition<br />

106<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

Vector control<br />

The following instructions apply to controllers equipped with a standard−I/O<br />

function module and a three−phase AC motor which has be<strong>en</strong> selected<br />

accordingly.<br />

7<br />

1. Connect the keypad<br />

2. Ensure that controller inhibit is<br />

active after mains connection<br />

3. Switch on the mains<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Terminal X3/28 = LOW<br />

4. The keypad is in "Disp" mo<strong>de</strong><br />

after approx. 2 s and indicates<br />

the output <strong>fr</strong>equ<strong>en</strong>cy (C0050)<br />

<br />

PS 1<br />

<br />

<br />

0050<br />

Hi<br />

Lo<br />

000 000<br />

Hz<br />

misc002<br />

The m<strong>en</strong>u USEr is active<br />

5. Go to the m<strong>en</strong>u ALL<br />

6. Change to the mo<strong>de</strong> to<br />

<br />

<br />

<br />

<br />

<br />

configure the basic settings for<br />

<br />

your drive<br />

000 000<br />

PS 1<br />

<br />

0050<br />

Hi<br />

Hz<br />

Lo<br />

Blinking on the display:<br />

0050<br />

7. Adapt the terminal configuration<br />

to the wiring (C0007)<br />

L<strong>en</strong>ze setting: −0−, i. e.<br />

E1: JOG1/3 fixed setpoint<br />

selection<br />

E2: JOG2/3<br />

E3: DCB DC brake<br />

E4: CW/CCW rotation<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

8. Set the minimum output<br />

<strong>fr</strong>equ<strong>en</strong>cy (C0010)<br />

L<strong>en</strong>ze setting: 0.00 Hz<br />

[f]<br />

C0011<br />

9. Set the maximum output<br />

<strong>fr</strong>equ<strong>en</strong>cy (C0011)<br />

L<strong>en</strong>ze setting: 50.00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

10. Set the acceleration time T ir<br />

(C0012)<br />

L<strong>en</strong>ze setting: 5.00 s<br />

B0 <br />

+ <br />

B<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = acceleration time<br />

wanted<br />

11. Set the <strong>de</strong>celeration time T if<br />

(C0013)<br />

L<strong>en</strong>ze setting: 5.00 s<br />

B <br />

<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

T Н Н t C0011<br />

if if f 2<br />

f 1<br />

t if = <strong>de</strong>celeration time<br />

wanted<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 107


7 Commissioning<br />

Vector control<br />

12. Activate the control mo<strong>de</strong> "vector<br />

control" (C0014 = 4)<br />

L<strong>en</strong>ze setting: Linear V/f<br />

characteristic control (C0014 =<br />

2)<br />

13. Adapt the voltage/curr<strong>en</strong>t range<br />

for the analog setpoint selection<br />

(C0034)<br />

L<strong>en</strong>ze setting: −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

<br />

<br />

<br />

<br />

SHPRG M<strong>en</strong>u<br />

Co<strong>de</strong><br />

001400<br />

Para<br />

Vector-Ctrl<br />

4<br />

9371BC008<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

Set the DIP switch on the<br />

standard I/O to the same<br />

range (see Mounting<br />

Instructions for the<br />

standard I/O)<br />

14. Enter the motor data See motor nameplate<br />

A Rated motor speed (C0087)<br />

L<strong>en</strong>ze setting: 1390 rpm<br />

B Rated motor curr<strong>en</strong>t (C0088)<br />

L<strong>en</strong>ze setting: Dep<strong>en</strong>ding on the<br />

controller<br />

Enter the value for the<br />

motor connection type<br />

(star/<strong>de</strong>lta) selected!<br />

C Rated motor <strong>fr</strong>equ<strong>en</strong>cy (C0089)<br />

L<strong>en</strong>ze setting: 50 Hz<br />

D<br />

E<br />

Rated motor voltage (C0090)<br />

L<strong>en</strong>ze setting: Dep<strong>en</strong>ding on the<br />

controller<br />

Motor−cos (C0091)<br />

L<strong>en</strong>ze setting: Dep<strong>en</strong>ding on the<br />

controller<br />

Enter the value for the<br />

motor connection type<br />

(star/<strong>de</strong>lta) selected!<br />

108<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


15. Start the motor parameter<br />

i<strong>de</strong>ntification (C0148)<br />

A Ensure that the controller is<br />

inhibited<br />

<br />

Commissioning<br />

Vector control<br />

X3<br />

20 28<br />

B Set C0148 = 1 Press in addition<br />

C<br />

D<br />

Enable the controller<br />

If the segm<strong>en</strong>t becomes<br />

active after approx. 30 s, inhibit<br />

the controller once again.<br />

misc001<br />

7<br />

Only wh<strong>en</strong> the motor is<br />

cold!<br />

Terminal X3/28 = LOW<br />

X3 Terminal X3/28 =<br />

20 28 misc002 HIGH<br />

The i<strong>de</strong>ntification<br />

starts:<br />

– The segm<strong>en</strong>t <br />

is off<br />

– The motor<br />

consumes curr<strong>en</strong>t<br />

and makes a<br />

high−pitched"<br />

tone.<br />

– The motor does not<br />

rotate!<br />

X3<br />

Terminal X3/28 =<br />

20 28<br />

misc001<br />

LOW<br />

I<strong>de</strong>ntification is<br />

completed.<br />

Calculated and<br />

stored:<br />

– V/f rated <strong>fr</strong>equ<strong>en</strong>cy<br />

(C0015)<br />

– Slip comp<strong>en</strong>sation<br />

(C0021)<br />

– Motor stator<br />

inductance (C0092)<br />

Measured and stored:<br />

– Motor stator<br />

resistance (C0084)<br />

= Total resistance<br />

of motor cable and<br />

motor<br />

<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 109


7 Commissioning<br />

Vector control<br />

16. If necessary, select more<br />

parameters<br />

Activate e.g. JOG <strong>fr</strong>equ<strong>en</strong>cies<br />

(C0037, C0038, C0039) or motor<br />

temperature monitoring (C0119)<br />

17. Go to the m<strong>en</strong>u ALL<br />

A Check the fan monitoring<br />

setting un<strong>de</strong>r co<strong>de</strong> C0608:<br />

– for <strong>82</strong>00 <strong>motec</strong> 0.25...0.37<br />

<strong>kW</strong> and <strong>0.55</strong>...<strong>2.2</strong> <strong>kW</strong>:<br />

C0608 = 0! (<strong>de</strong>fault setting)<br />

– for <strong>82</strong>00 <strong>motec</strong> 3...7.5 <strong>kW</strong>:<br />

C0608 =1 or C0608 = 2!<br />

Stop!<br />

Function must be<br />

activated during<br />

commissioning!<br />

Otherwise, the<br />

controller may be<br />

<strong>de</strong>stroyed through<br />

overheating!<br />

– for all other controllers:<br />

C0608 = 0 ! (<strong>de</strong>fault<br />

setting)<br />

B Select additional functions via<br />

co<strong>de</strong>s, if necessary.<br />

Wh<strong>en</strong> all settings are complete:<br />

18. Select the setpoint E.g. via pot<strong>en</strong>tiometer at<br />

terminals 7, 8, 9<br />

19. Enable the controller<br />

X3<br />

20 28<br />

misc002<br />

Terminal X3/28 = HIGH<br />

20. The drive should now be running. If the drive does not<br />

start, press in<br />

addition<br />

110<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

Vector control<br />

Optimising the vector control<br />

In g<strong>en</strong>eral, the vector control is ready for operation after the motor<br />

parameters have be<strong>en</strong> i<strong>de</strong>ntified. Vector control must only be optimised for<br />

the following drive performance: −9−<br />

Drive performance<br />

Rough motor run and motor curr<strong>en</strong>t (C0054) > 60 %<br />

rated motor curr<strong>en</strong>t in idle running (stationary<br />

operation)<br />

Torque too low for <strong>fr</strong>equ<strong>en</strong>cies f < 5 Hz (starting<br />

torque)<br />

Poor constant speed at high loads (setpoint and motor<br />

speed are not proportional).<br />

7<br />

Remedy<br />

1. Reduction of motor inductance (C0092) by 10 %<br />

2. Check of motor curr<strong>en</strong>t un<strong>de</strong>r C0054<br />

3. If the motor curr<strong>en</strong>t (C0054) > 50 % of the rated<br />

motor curr<strong>en</strong>t:<br />

– C0092 must be reduced until the motor curr<strong>en</strong>t<br />

amounts to 50 % of the rated motor curr<strong>en</strong>t<br />

– Reduce C0092 by max. 20 %!<br />

– Note: If you reduce C0092 the torque will<br />

<strong>de</strong>crease!<br />

Increase of motor resistance (C0084) or increase of<br />

motor inductance (C0092)<br />

Increase of slip comp<strong>en</strong>sation (C0021)<br />

Overcomp<strong>en</strong>sation results in drive instability!<br />

Error messages OC1, OC3, OC4 or OC5 during<br />

acceleration times (C0012) < 1 s (drive controller is no<br />

Change readjustm<strong>en</strong>t time of the I max controller<br />

(C0078):<br />

longer able to follow the dynamic processes)<br />

Reduction of C0078 = I max controller becomes<br />

quicker (more dynamic)<br />

Increase of C0078 = I max controller becomes<br />

slower ("smoother")<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 111


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Note!<br />

The following table <strong>de</strong>scribes in <strong>de</strong>tail the co<strong>de</strong>s m<strong>en</strong>tioned in<br />

the examples for commissioning!<br />

Do not change co<strong>de</strong>s, the meaning of which is unknown to<br />

you! All co<strong>de</strong>s are <strong>de</strong>scribed in <strong>de</strong>tail in the System Manual.<br />

How to read the co<strong>de</strong> table<br />

Column Abbreviation Meaning<br />

Co<strong>de</strong> Cxxxx Co<strong>de</strong> Cxxxx The parameter value of a co<strong>de</strong> can be<br />

differ<strong>en</strong>t in every parameter set.<br />

1 Subco<strong>de</strong> 1 of Cxxxx<br />

Parameter value accepted immediately<br />

2 Subco<strong>de</strong> 2 of Cxxxx (ONLINE)<br />

* Parameter value of the co<strong>de</strong> is the same in all parameter sets<br />

Keypad E<strong>82</strong>ZBC Changed parameters will be accepted after<br />

pressing <br />

Keypad XT<br />

EMZ9371BC<br />

Changed parameters will be accepted after<br />

pressing <br />

Keypad E<strong>82</strong>ZBC Changed parameters will be accepted after<br />

pressing if the controller is inhibited<br />

Keypad XT<br />

EMZ9371BC<br />

Changed parameters will be accepted after<br />

pressing if the controller is inhibited<br />

(A)<br />

Co<strong>de</strong>, subco<strong>de</strong> or selection are only available wh<strong>en</strong> using an<br />

Application−I/O<br />

uSEr<br />

With L<strong>en</strong>ze setting the co<strong>de</strong> is available in the USER−m<strong>en</strong>u<br />

Name<br />

Name of the co<strong>de</strong><br />

L<strong>en</strong>ze L<strong>en</strong>ze setting (<strong>de</strong>fault setting/value set un<strong>de</strong>r C0002)<br />

<br />

Further information can be obtained <strong>fr</strong>om "IMPORTANT"<br />

Selection 1 {%} 99 Min. value {unit} Max. value<br />

IMPORTANT − Brief, important explanations<br />

112<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

7<br />

Co<strong>de</strong> Possible settings IMPORTANT<br />

No. Name L<strong>en</strong>ze Selection<br />

C0002 Parameter set 0 0 Ready PAR1 ... PAR4:<br />

*<br />

<br />

managem<strong>en</strong>t<br />

−10−<br />

Parameter sets of the<br />

controller<br />

uSEr<br />

PAR1 ... PAR4 also contain<br />

parameters for<br />

Standard−I/O,<br />

Application−I/O, AS interface<br />

or system bus (CAN)<br />

FPAR1:<br />

Module−specific parameter<br />

set of the fieldbus function<br />

modules INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

FPAR1 is saved in the<br />

function module<br />

Restorage of 1 L<strong>en</strong>ze setting PAR1 Restorage of factory setting in<br />

<strong>de</strong>fault<br />

the selected parameter set<br />

2<br />

setting<br />

L<strong>en</strong>ze setting PAR2<br />

3 L<strong>en</strong>ze setting PAR3<br />

4 L<strong>en</strong>ze setting PAR4<br />

31 L<strong>en</strong>ze setting FPAR1 Restorage of <strong>de</strong>fault setting in<br />

the fieldbus function module<br />

61 L<strong>en</strong>ze setting PAR1 + FPAR1 Restorage of <strong>de</strong>fault setting in<br />

62 L<strong>en</strong>ze setting PAR2 + FPAR1<br />

the selected parameter set of<br />

the controller and the fieldbus<br />

63 L<strong>en</strong>ze setting PAR3 + FPAR1 function module<br />

64 L<strong>en</strong>ze setting PAR4 + FPAR1<br />

C0002<br />

*<br />

<br />

uSEr<br />

(cont.)<br />

Parameter set<br />

transfer using<br />

the keypad<br />

Keypad Controller<br />

70 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

10 With all other function modules<br />

Use the keypad to transfer<br />

parameter sets to other<br />

controllers.<br />

During transfer the<br />

parameters cannot be<br />

accessed via other channels!<br />

All available parameter sets<br />

(PAR1 ... PAR4, and FPAR1) are<br />

overwritt<strong>en</strong> with the<br />

corresponding keypad data<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 113


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Co<strong>de</strong><br />

No.<br />

C0002<br />

*<br />

<br />

uSEr<br />

(cont.)<br />

Name<br />

Parameter set<br />

transfer using<br />

the keypad<br />

Possible settings<br />

L<strong>en</strong>ze<br />

Selection<br />

Keypad PAR1 (+ FPAR1)<br />

71 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

11 With all other function modules<br />

Keypad PAR2 (+ FPAR1)<br />

72 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

12 With all other function modules<br />

Keypad PAR3 (+ FPAR1)<br />

73 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

13 With all other function modules<br />

Keypad PAR4 (+ FPAR1)<br />

74 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

14 With all other function modules<br />

Controller Keypad<br />

80 With function module<br />

Application−I/O, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

20 With all other function modules<br />

Keypad Function module<br />

40 Only with function module<br />

INTERBUS, PROFIBUS−DP,<br />

LECOM−B, DeviceNet/CANop<strong>en</strong><br />

Function module Keypad<br />

50 Only with function module<br />

INTERBUS, PROFIBUS−DP,<br />

LECOM−B, DeviceNet/CANop<strong>en</strong><br />

IMPORTANT<br />

Overwrite selected parameter<br />

set and, if necessary, FPAR1<br />

with the corresponding keypad<br />

data<br />

All available parameter sets<br />

(PAR1 ... PAR4, and FPAR1) are<br />

copied to the keypad<br />

Overwrite the module−specific<br />

parameter set FPAR1 only<br />

Copy the module−specific<br />

parameter set FPAR1 only<br />

114<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

7<br />

Co<strong>de</strong><br />

No.<br />

C0002<br />

*<br />

<br />

uSEr<br />

(cont.)<br />

C0002<br />

*<br />

<br />

uSEr<br />

(cont.)<br />

C0003<br />

*<br />

<br />

Name<br />

Saving of<br />

own settings<br />

Loading/copyi<br />

ng of your<br />

own basic<br />

settings<br />

Non−volatile<br />

parameter<br />

saving<br />

Possible settings<br />

IMPORTANT<br />

L<strong>en</strong>ze Selection<br />

9 PAR1 Own settings You can save your own basic<br />

settings for a controller (e.g.<br />

machine <strong>de</strong>livery status):<br />

1. Ensure that parameter set 1<br />

is active<br />

2. Controller inhibit<br />

3. Set C0003 = 3,<br />

acknowledge with <br />

4. Set C0002 = 9,<br />

acknowledge with , to<br />

save your own basic<br />

settings<br />

5. Set C0003 = 1,<br />

acknowledge with <br />

6. Enable the controller.<br />

Using this function, PAR1 can<br />

be copied to parameter sets<br />

PAR2 ... PAR4<br />

5 Own settings PAR1 Restorage of own basic setting<br />

6 Own settings PAR2<br />

in the selected parameter set<br />

7 Own settings PAR3<br />

8 Own settings PAR4<br />

1 0 Parameter not saved in EEPROM Data loss after mains<br />

disconnection<br />

1 Parameter always saved in EEPROM Active after every mains<br />

connection<br />

Cyclic parameter changes<br />

via bus module are not<br />

allowed.<br />

3 Own settings saved in EEPROM The parameter set 1 saved as<br />

own basic setting with C0002<br />

= 9<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 115


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Co<strong>de</strong><br />

No.<br />

C0007<br />

<br />

uSEr<br />

C0007<br />

<br />

uSEr<br />

(cont.)<br />

Name<br />

Fixed<br />

configuration<br />

of digital<br />

inputs<br />

Possible settings<br />

IMPORTANT<br />

L<strong>en</strong>ze Selection<br />

Change un<strong>de</strong>r C0007 will be<br />

copied to the corresponding<br />

subco<strong>de</strong> of C0410. Free<br />

configuration un<strong>de</strong>r C0410<br />

sets C0007 = 255!<br />

0 E4 E3 E2 E1 CW/CCW = CW<br />

0 CW/CC DCB JOG2/3 JOG1/3 rotation/CCW rotation<br />

W<br />

DCB = DC−injection brake<br />

1 CW/CC PAR JOG2/3 JOG1/3 QSP = Quick stop<br />

W<br />

PAR = Parameter set<br />

2 CW/CC QSP JOG2/3 JOG1/3 changeover (PAR1 <br />

W<br />

PAR2)<br />

3 CW/CC PAR DCB JOG1/3<br />

– PAR1 = LOW, PAR2 =<br />

W<br />

HIGH<br />

4 CW/CC QSP PAR JOG1/3<br />

W<br />

– The terminal must be<br />

assigned to the function<br />

5 CW/CC DCB TRIP set JOG1/3<br />

"PAR" in PAR1 and PAR2.<br />

W<br />

– Configurations with "PAR"<br />

j6 CW/CC PAR TRIP set JOG1/3<br />

W<br />

are only allowed if C0988<br />

= 0<br />

7 CW/CC<br />

W<br />

PAR DCB TRIP set<br />

<br />

TRIP set = external fault<br />

8 CW/CC QSP PAR TRIP set<br />

W<br />

9 CW/CC QSP TRIP set JOG1/3<br />

W<br />

10 CW/CC<br />

W<br />

TRIP set UP DOWN<br />

E4 E3 E2 E1 Selection of<br />

11 CW/CC DCB UP DOWN fixed setpoints<br />

W<br />

JOG1/3 JOG2/3<br />

12 CW/CC PAR UP DOWN LOW LOW<br />

W<br />

HIGH LOW<br />

13 CW/CC QSP UP DOWN LOW HIGH<br />

W<br />

HIGH HIGH<br />

14 CCW/QS CW/QSP DCB JOG1/3<br />

P<br />

15 CCW/QS CW/QSP PAR JOG1/3<br />

P<br />

16 CCW/QS CW/QSP JOG2/3 JOG1/3<br />

P<br />

17 CCW/QS CW/QSP PAR DCB<br />

P<br />

18 CCW/QS CW/QSP PAR TRIP set<br />

P<br />

19 CCW/QS CW/QSP DCB TRIP set<br />

P<br />

active<br />

C0046<br />

JOG1<br />

JOG2<br />

JOG3<br />

116<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

7<br />

Co<strong>de</strong><br />

No.<br />

C0007<br />

<br />

uSEr<br />

(cont.)<br />

C0007<br />

<br />

uSEr<br />

(cont.)<br />

Name<br />

Possible settings<br />

IMPORTANT<br />

L<strong>en</strong>ze Selection<br />

E4 E3 E2 E1 UP/DOWN = Motor<br />

20 CCW/QS CW/QSP TRIP set JOG1/3 pot<strong>en</strong>tiometer functions<br />

P<br />

H/Re = Hand/remote<br />

21 CCW/QS CW/QSP UP DOWN changeover<br />

P<br />

PCTRL1−I−OFF = Switch−off<br />

22 CCW/QS CW/QSP UP JOG1/3 process controller I<br />

P<br />

compon<strong>en</strong>t<br />

23 M/Re CW/CC UP DOWN DFIN1−ON = Digital<br />

W<br />

<strong>fr</strong>equ<strong>en</strong>cy input 0 ... 10 kHz<br />

24 M/Re PAR UP DOWN PCTRL1−OFF = Switch off<br />

25 M/Re DCB UP DOWN process controller<br />

26 M/Re JOG1/3 UP DOWN<br />

27 M/Re TRIP set UP DOWN<br />

28 JOG2/3 JOG1/3 PCTRL1<br />

−I−OFF<br />

29 JOG2/3 DCB PCTRL1<br />

−I−OFF<br />

30 JOG2/3 QSP PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

E4 E3 E2 E1<br />

31 DCB QSP PCTRL1<br />

−I−OFF<br />

32 TRIP set QSP PCTRL1<br />

−I−OFF<br />

33 QSP PAR PCTRL1<br />

−I−OFF<br />

34 CW/QSP CCW/QS<br />

P<br />

PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

35 JOG2/3 JOG1/3 PAR DFIN1−O<br />

N<br />

36 DCB QSP PAR DFIN1−O<br />

N<br />

37 JOG1/3 QSP PAR DFIN1−O<br />

N<br />

38 JOG1/3 PAR TRIP set DFIN1−O<br />

N<br />

39 JOG2/3 JOG1/3 TRIP set DFIN1−O<br />

N<br />

40 JOG1/3 QSP TRIP set DFIN1−O<br />

N<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 117


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Co<strong>de</strong><br />

No.<br />

C0007<br />

<br />

uSEr<br />

(cont.)<br />

C0010<br />

uSEr<br />

C0011<br />

uSEr<br />

C0012<br />

uSEr<br />

Name<br />

Minimum<br />

output<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

Maximum<br />

output<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

Acceleration<br />

time main<br />

setpoint<br />

Possible settings<br />

L<strong>en</strong>ze Selection<br />

E4 E3 E2 E1<br />

41 JOG1/3 DCB TRIP set DFIN1−O<br />

N<br />

42 QSP DCB TRIP set DFIN1−O<br />

N<br />

43 CW/CC<br />

W<br />

QSP TRIP set DFIN1−O<br />

N<br />

44 UP DOWN PAR DFIN1−O<br />

N<br />

45 CW/CC<br />

W<br />

QSP PAR DFIN1−O<br />

N<br />

46 M/Re PAR QSP JOG1/3<br />

47 CW/QSP CCW/QS M/Re JOG1/3<br />

P<br />

48 PCTRL1<br />

− OFF<br />

DCB PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

49 PCTRL1<br />

− OFF<br />

50 PCTRL1<br />

− OFF<br />

JOG1/3 QSP DFIN1−O<br />

N<br />

JOG1/3<br />

PCTRL1<br />

−I−OFF<br />

51 DCB PAR PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

IMPORTANT<br />

255 Free configuration un<strong>de</strong>r C0410 Only display<br />

Do not change C0007 since<br />

settings un<strong>de</strong>r C0410 can be<br />

lost<br />

0.00 0.00<br />

14.5 Hz<br />

50.00 7.50<br />

87 Hz<br />

{0.02<br />

Hz}<br />

{0.02<br />

Hz}<br />

5.00 0.00 {0.02<br />

s}<br />

650.00 C0010 is not effective with<br />

bipolar setpoint selection<br />

(−10 V ... + 10 V)<br />

C0010 only <strong>de</strong>fines the<br />

analog input 1<br />

650.00 Speed setting range 1 : 6<br />

for L<strong>en</strong>ze geared motors:<br />

Setting absolutely required<br />

for operation with L<strong>en</strong>ze<br />

geared motors.<br />

1300.00 Refer<strong>en</strong>ce: <strong>fr</strong>equ<strong>en</strong>cy change 0<br />

Hz ... C0011<br />

Additional setpoint <br />

C0220<br />

Acceleration times can be<br />

activated via digital signals<br />

C0101<br />

118<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

7<br />

Co<strong>de</strong><br />

No.<br />

C0013<br />

uSEr<br />

C0014<br />

<br />

C0015<br />

uSEr<br />

C0016<br />

uSEr<br />

Name<br />

Deceleration<br />

time main<br />

setpoint<br />

Operating<br />

mo<strong>de</strong><br />

V/f rated<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

Possible settings<br />

L<strong>en</strong>ze Selection<br />

5.00 0.00 {0.02<br />

s}<br />

2 2 V/f characteristic control V ~ f<br />

(Linear characteristic with constant<br />

V min boost)<br />

3 V/f characteristic control V ~ f 2<br />

(Square−law characteristic with<br />

constant V min boost)<br />

IMPORTANT<br />

1300.00 Refer<strong>en</strong>ce: <strong>fr</strong>equ<strong>en</strong>cy change<br />

C0011 ... 0 Hz<br />

Additional setpoint <br />

C0221<br />

Deceleration times to be<br />

activated via digital signals<br />

C0103<br />

<br />

<br />

Commissioning without<br />

motor parameter<br />

i<strong>de</strong>ntification possible<br />

B<strong>en</strong>efit of i<strong>de</strong>ntification with<br />

C0148:<br />

– Improved smooth running<br />

at low speed<br />

– V/f rated <strong>fr</strong>equ<strong>en</strong>cy<br />

(C0015) and slip (C0021)<br />

are calculated and stored.<br />

They do not have to be<br />

<strong>en</strong>tered<br />

4 Vector control For initial selection <strong>en</strong>ter the<br />

5 S<strong>en</strong>sorless torque control with<br />

motor data and i<strong>de</strong>ntify the<br />

speed limitation<br />

motor parameters with<br />

C0148<br />

Torque setpoint via C0412/6<br />

Otherwise commissioning is<br />

Speed limitation via setpoint 1<br />

not possible<br />

(NSET1−N1), if C0412/1 is<br />

assigned, if not via max.<br />

<strong>fr</strong>equ<strong>en</strong>cy (C0011)<br />

50.00 7.50 {0.02<br />

Hz}<br />

V min boost 0.00 {0.01<br />

%}<br />

960.00 C0015 is calculated and<br />

stored un<strong>de</strong>r C0148 wh<strong>en</strong><br />

the motor parameters are<br />

i<strong>de</strong>ntified<br />

Settings applies to all<br />

possible mains voltages<br />

40.00 Dep<strong>en</strong>ding on the controller<br />

Setting applies to all mains<br />

voltages permitted<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 119


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Co<strong>de</strong><br />

No.<br />

C0034<br />

*<br />

<br />

uSEr<br />

C0034<br />

*<br />

<br />

(A)<br />

uSEr<br />

Name<br />

Setpoint<br />

selection<br />

range<br />

Standard–I/O<br />

(X3/8)<br />

−11−<br />

Setpoint<br />

selection<br />

range<br />

Application<br />

I/O<br />

Possible settings<br />

IMPORTANT<br />

L<strong>en</strong>ze Selection<br />

Observe the switch position of<br />

the function module!<br />

0 0 Unipolar voltage 0 ... 5 V / 0 ... 10 V<br />

Curr<strong>en</strong>t 0 ... 20 mA<br />

1 Curr<strong>en</strong>t 4 ... 20 mA Changing the direction of<br />

rotation is only possible with a<br />

digital signal.<br />

2 Bipolar voltage −10 V ... +10 V Minimum output <strong>fr</strong>equ<strong>en</strong>cy<br />

(C0010) not effective<br />

Individual adjustm<strong>en</strong>t of<br />

offset and gain<br />

3 Curr<strong>en</strong>t 4 ... 20 mA op<strong>en</strong>−circuit<br />

monitored<br />

TRIP Sd5, if I < 4 mA<br />

Changing the direction of<br />

rotation is only possible with a<br />

digital signal.<br />

Observe the jumper setting of<br />

the function module!<br />

1 X3/1U, X3/1I 0 0 Unipolar voltage 0 ... 5 V / 0 ... 10 V<br />

2 X3/2U, X3/2I 1 Bipolar voltage −10 V ... +10 V Minimum output <strong>fr</strong>equ<strong>en</strong>cy<br />

(C0010) not effective<br />

2 Curr<strong>en</strong>t 0 ... 20 mA<br />

3 Curr<strong>en</strong>t 4 ... 20 mA Changing the direction of<br />

rotation is only possible with a<br />

digital signal.<br />

4 Curr<strong>en</strong>t 4 ... 20 mA op<strong>en</strong>−circuit<br />

monitored<br />

C0037 JOG1 20.00 −650.00 {0.02<br />

Hz}<br />

C0038 JOG2 30.00 −650.00 {0.02<br />

Hz}<br />

C0039 JOG3 40.00 −650.00 {0.02<br />

Hz}<br />

C0050<br />

*<br />

uSEr<br />

C0087<br />

Output<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

(MCTRL1−NO<br />

UT)<br />

Rated motor<br />

speed<br />

Changing the direction of<br />

rotation is only possible with a<br />

digital signal.<br />

TRIP Sd5 if I < 4 mA<br />

650.00 JOG = Setpoint<br />

Additional JOG <strong>fr</strong>equ<strong>en</strong>cies <br />

650.00 C0440<br />

650.00<br />

−650.00 {Hz} 650.00 Only display: Output <strong>fr</strong>equ<strong>en</strong>cy<br />

without slip comp<strong>en</strong>sation<br />

300 {1 rpm} 16000 Dep<strong>en</strong>ding on the controller<br />

120<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

7<br />

Co<strong>de</strong><br />

No.<br />

C0088<br />

C0089<br />

C0090<br />

Name<br />

Rated motor<br />

curr<strong>en</strong>t<br />

Rated motor<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

Rated motor<br />

voltage<br />

Possible settings<br />

IMPORTANT<br />

L<strong>en</strong>ze Selection<br />

0.0 {0.1 A} 650.0 Dep<strong>en</strong>ding on the controller<br />

0.0 ... 2.0 x rated output<br />

curr<strong>en</strong>t of the controller<br />

50 10 {1 Hz} 960<br />

50 {1 V} 500 230 V with 230 V controllers,<br />

400 V with 400 V controllers<br />

C0091 Motor cos ϕ 0.40 {0.1} 1.0 Dep<strong>en</strong>ding on the controller<br />

C0119<br />

<br />

−12−<br />

C0140<br />

*<br />

Configuration<br />

of motor<br />

temperature<br />

monitoring<br />

(PTC input) /<br />

earth fault<br />

<strong>de</strong>tection<br />

Additive<br />

<strong>fr</strong>equ<strong>en</strong>cy<br />

setpoint<br />

(NSET1−NADD<br />

)<br />

0 0 PTC input not<br />

active<br />

1 PTC input active,<br />

TRIP set<br />

2 PTC input active,<br />

Warning set<br />

3 PTC input not<br />

active<br />

4 PTC input active,<br />

TRIP set<br />

5 PTC input active,<br />

Warning set<br />

0.00 −650.00 {0.02<br />

Hz}<br />

Earth fault<br />

<strong>de</strong>tection active<br />

Earth fault<br />

<strong>de</strong>tection<br />

Signal output configuration<br />

un<strong>de</strong>r C0415<br />

If several parameter sets<br />

are used, the monitoring<br />

must be separately adjusted<br />

for each parameter set.<br />

Deactivate the earth fault<br />

<strong>de</strong>tection, if it has be<strong>en</strong><br />

activated unint<strong>en</strong>tionally.<br />

If the earth fault <strong>de</strong>tection is<br />

active, the motor starts after<br />

controller <strong>en</strong>able with a<br />

<strong>de</strong>lay of approx.40 ms.<br />

650.00 Selection via function <br />

of the keypad or the<br />

parameter channel<br />

Is ad<strong>de</strong>d to main setpoint<br />

Value is stored wh<strong>en</strong><br />

switching the mains or<br />

removing the keypad<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 121


7 Commissioning<br />

The most important co<strong>de</strong>s for commissioning<br />

Co<strong>de</strong><br />

No.<br />

C0148<br />

*<br />

<br />

C0517<br />

*<br />

<br />

C0608<br />

*<br />

Name<br />

Motor<br />

parameter<br />

i<strong>de</strong>ntification<br />

Possible settings<br />

L<strong>en</strong>ze<br />

Selection<br />

IMPORTANT<br />

0 0 Ready Only wh<strong>en</strong> the motor is cold!<br />

1. Inhibit controller, wait until<br />

drive is in standstill<br />

2. Enter the correct motor data<br />

un<strong>de</strong>r C0087, C0088,<br />

1 Start i<strong>de</strong>ntification<br />

V/f−rated <strong>fr</strong>equ<strong>en</strong>cy (C0015), slip<br />

comp<strong>en</strong>sation (C0021) and<br />

motor stator inductivity (C0092)<br />

are calculated and saved.<br />

The motor stator resistance<br />

(C0084) = total resistance of<br />

motor cable and motor is<br />

measured and saved<br />

C0089, C0090, C0091 (see<br />

motor nameplate).<br />

3. C0148 = set 1 by <br />

4. Enable controller<br />

The i<strong>de</strong>ntification<br />

– starts, gets out<br />

– the motor makes a<br />

high−pitched tone, but<br />

does not rotate!<br />

– takes approx. 30 s<br />

– is completed wh<strong>en</strong> is<br />

on again<br />

5. Controller inhibit<br />

User m<strong>en</strong>u After mains switching or<br />

wh<strong>en</strong> using the function<br />

the co<strong>de</strong> <strong>fr</strong>om C0517/1<br />

will be displayed.<br />

1 Memory 1 50 C0050 Output <strong>fr</strong>equ<strong>en</strong>cy (MCTRL1−NOUT)<br />

2 Memory 2 34 C0034 Analog setpoint selection range<br />

3 Memory 3 7 C0007 Fixed configuration − digital input<br />

signals<br />

4 Memory 4 10 C0010 Minimum output <strong>fr</strong>equ<strong>en</strong>cy<br />

5 Memory 5 11 C0011 Maximum output <strong>fr</strong>equ<strong>en</strong>cy<br />

6 Memory 6 12 C0012 Acceleration time main setpoint<br />

7 Memory 7 13 C0013 Deceleration time main setpoint<br />

8 Memory 8 15 C0015 V/f rated <strong>fr</strong>equ<strong>en</strong>cy<br />

9 Memory 9 16 C0016 U min boost<br />

10 Memory 10 2 C0002 Parameter set transfer<br />

Fan<br />

monitoring<br />

<br />

<br />

In L<strong>en</strong>ze setting, the user<br />

m<strong>en</strong>u contains the most<br />

important co<strong>de</strong>s for setting<br />

up the control mo<strong>de</strong> "V/f<br />

characteristic control with<br />

linear characteristic"<br />

Wh<strong>en</strong> the password<br />

protection is activated, only<br />

the co<strong>de</strong>s <strong>en</strong>tered un<strong>de</strong>r<br />

C0517 are <strong>fr</strong>eely accessible.<br />

Enter the required co<strong>de</strong><br />

numbers in the subco<strong>de</strong>s.<br />

Co<strong>de</strong>s, which are only active<br />

wh<strong>en</strong> being used together<br />

with an Application−I/O,<br />

cannot be <strong>en</strong>tered!<br />

0 0 Not active <strong>82</strong>00 <strong>motec</strong> 3 ... 7.5 <strong>kW</strong>:<br />

Function must be activated<br />

during commissioning!<br />

1 TRIP error message<br />

Otherwise, the controller may<br />

be <strong>de</strong>stroyed through<br />

overheating.<br />

2 Warning<br />

For all other controllers:<br />

It is ess<strong>en</strong>tial to set C0608 = 0.<br />

122<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Fault <strong>de</strong>tection and elimination<br />

Faulty drive behaviour<br />

8<br />

Fault Cause Remedy<br />

Motor does not rotate<br />

DC−bus voltage too low<br />

(Red LED is blinking every 0.4 s;<br />

keypad display LU)<br />

Check mains voltage<br />

Controller inhibited<br />

(Gre<strong>en</strong> LED is blinking, keypad display:<br />

)<br />

Automatic start inhibited<br />

(C0142 = 0 or 2)<br />

Remove the controller inhibit,<br />

controller inhibit can be set<br />

through several sources<br />

LOW−HIGH signal at X3/28<br />

If necessary, correct start<br />

condition (C0142)<br />

DC injection brake active (DCB) Deactivate DC injection brake<br />

Mechanical motor brake is not released Manual or electrical release of<br />

mechanical motor brake<br />

Quick stop (QSP) active (keypad display: Remove quick stop<br />

)<br />

Setpoint = 0<br />

Setpoint selection<br />

JOG setpoint activated and JOG<br />

<strong>fr</strong>equ<strong>en</strong>cy = 0<br />

JOG setpoint selection<br />

(C0037 ... C0039)<br />

Active fault<br />

Eliminate fault<br />

Wrong parameter set active<br />

Change to correct parameter<br />

set via terminal<br />

Control mo<strong>de</strong> C0014 = −4−, −5−, but no<br />

motor parameter i<strong>de</strong>ntification<br />

Motor parameter i<strong>de</strong>ntification<br />

(C0148)<br />

Un<strong>de</strong>r C0410 several functions which Correct configuration in C0410<br />

exclu<strong>de</strong> each other, are assigned to the<br />

same signal source.<br />

Use internal voltage source X3/20 for Bridge terminals<br />

function modules Standard I/O,<br />

INTERBUS, PROFIBUS−DP or LECOM−B<br />

(RS485):<br />

Bridge betwe<strong>en</strong> X3/7 and X3/39 is<br />

missing<br />

Motor does not rotate smoothly Defective motor cable Check motor cable<br />

Maximum curr<strong>en</strong>t set too low (C0022, Adaptation to the application<br />

C0023)<br />

Motor un<strong>de</strong>rexcited or overexcited Check parameter setting<br />

(C0015, C0016, C0014)<br />

Curr<strong>en</strong>t consumption of motor<br />

too high<br />

Motor rotates, setpoints are 0"<br />

C0084, C0087, C0088, C0089, C0090,<br />

C0091 and/or C0092 are not adapted to<br />

the motor data<br />

Manual adaptation or<br />

i<strong>de</strong>ntification of motor<br />

parameters (C0148)<br />

Setting of C0016 too high<br />

Correct setting<br />

Setting of C0015 too low<br />

Correct setting<br />

C0084, C0087, C0088, C0089, C0090, Manual adaptation or<br />

C0091 and/or C0092 are not adapted to i<strong>de</strong>ntification of motor<br />

the motor data<br />

parameters (C0148)<br />

With the function of the keypad a<br />

setpoint has be<strong>en</strong> selected.<br />

Set the setpoint to "0" by<br />

C0140 = 0<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 123


8<br />

Fault <strong>de</strong>tection and elimination<br />

Faulty drive behaviour<br />

Fault<br />

Motor parameter i<strong>de</strong>ntification<br />

stops with error LP1<br />

Unacceptable drive response<br />

with vector control<br />

Torque dip in the field weak<strong>en</strong>ing<br />

range<br />

Stalling of the motor wh<strong>en</strong><br />

operating in the field weak<strong>en</strong>ing<br />

range<br />

Cause<br />

Remedy<br />

Motor too small compared with rated<br />

power<br />

DC brake active via terminal<br />

various Vector control optimisation (<br />

111)<br />

various<br />

Contact L<strong>en</strong>ze<br />

124<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


PS<br />

<br />

<br />

<br />

m<br />

Hi<br />

Hz V A<br />

Lo<br />

%sh<br />

rpm Ω°C<br />

Fault <strong>de</strong>tection and elimination<br />

Fault messages<br />

8<br />

LED’s at the drive controller (status display)<br />

LED −13−<br />

red <br />

gre<strong>en</strong> <br />

Operating status<br />

off on Controller <strong>en</strong>abled<br />

on on Mains switched on and automatic start<br />

inhibited<br />

off slowly blinking Controller inhibited<br />

off fast blinking Motor parameter i<strong>de</strong>ntification<br />

fast blinking off Un<strong>de</strong>rvoltage switch−off<br />

slowly blinking off Fault active, check un<strong>de</strong>r C0161<br />

<br />

<br />

1<br />

8888888 8<br />

88888<br />

<br />

<br />

<br />

<br />

<br />

<br />

2<br />

<br />

<br />

<br />

01 61 000 1<br />

880Hr<br />

<br />

<br />

<br />

PS<br />

Hi<br />

Lo<br />

<br />

m<br />

Hz V A<br />

%sh<br />

rpm Ω°C<br />

3<br />

X3<br />

20 28<br />

5<br />

OFF<br />

4 6 ON<br />

L<br />

<strong>82</strong>mot355<br />

Reset the drive controller in this way, if a fault occurs (TRIP−Reset):<br />

1. Plug the keypad onto the AIF interface during operation.<br />

2. Read and take down fault message of the keypad display.<br />

3. Inhibit controller.<br />

4. Separate controller <strong>fr</strong>om the mains.<br />

5. Carry out a fault analysis and eliminate the faults.<br />

6. Restart the controller.<br />

Error messages at the keypad or in the parameter setting program<br />

Global Drive Control<br />

Keypad PC 1) Error Cause Remedy<br />

noer 0 No fault − −<br />

ccr<br />

<br />

71 System fault Strong interfer<strong>en</strong>ces on control Shield control cables<br />

cables<br />

Ground or earth loops in the<br />

wiring<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 125


8<br />

Keypad<br />

ce0<br />

<br />

ce1<br />

<br />

ce2<br />

<br />

ce3<br />

<br />

ce4<br />

<br />

ce5<br />

<br />

ce6<br />

<br />

Fault <strong>de</strong>tection and elimination<br />

Fault messages<br />

PC 1) Error<br />

61 Communication<br />

fault to AIF<br />

(configurable in<br />

C0126)<br />

62 Communication<br />

fault to CAN−IN1<br />

with Sync control<br />

63 Communication<br />

error to CAN−IN2<br />

64 Communication<br />

error to CAN−IN1<br />

with ev<strong>en</strong>t or time<br />

control<br />

65 BUS−OFF<br />

(many<br />

communication<br />

faults occurred)<br />

66 CAN Time−Out<br />

(configurable in<br />

C0126)<br />

67 Function module<br />

system bus (CAN)<br />

on FIF has set<br />

"Warning" or<br />

"BUS−OFF"<br />

(configurable in<br />

C0126)<br />

Cause<br />

Faulty transmission of control<br />

commands via AIF<br />

CAN−IN1 object receives faulty<br />

data or communication is<br />

interrupted<br />

CAN−IN2 object receives faulty<br />

data or communication is<br />

interrupted<br />

CAN−IN1 object receives faulty<br />

data or communication is<br />

interrupted<br />

Controller has received too<br />

many incorrect telegrams via<br />

the system bus and has be<strong>en</strong><br />

disconnected<br />

For remote parameter setting<br />

via system bus (C0370):<br />

Slave does not answer.<br />

Communication monitoring<br />

time excee<strong>de</strong>d.<br />

For operation with application<br />

I/O:<br />

Faulty parameter setting of<br />

parameter set changeover<br />

For operation with module in<br />

FIF:<br />

Internal fault<br />

CAN controller sets "Warning"<br />

or "BUS OFF"<br />

Remedy<br />

Insert the communication module<br />

into the hand terminal<br />

Plug−in connection − bus<br />

module Check FIF<br />

Check transmitter<br />

Increase monitoring time un<strong>de</strong>r<br />

C0357/1 if necessary<br />

Plug−in connection − bus<br />

module Check FIF<br />

Check transmitter<br />

Increase monitoring time un<strong>de</strong>r<br />

C0357/2 if necessary<br />

Plug−in connection − bus<br />

module Check FIF<br />

Check transmitter<br />

Increase monitoring time un<strong>de</strong>r<br />

C0357/3 if necessary<br />

Check whether bus terminator<br />

available<br />

Check scre<strong>en</strong> contact of the<br />

cables<br />

Check PE connection<br />

Check bus load, if necessary,<br />

reduce the baud rate<br />

Check system bus wiring<br />

Check system bus<br />

configuration<br />

In all parameter sets the signal<br />

"parameter set changeover"<br />

(C0410/13, C0410/14) must be<br />

combined with the same source<br />

Contact L<strong>en</strong>ze<br />

Check whether bus terminator<br />

available<br />

Check scre<strong>en</strong> contact of the<br />

cables<br />

Check PE connection<br />

Check bus load, if necessary,<br />

reduce the baud rate<br />

126<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Keypad<br />

ce7<br />

<br />

EEr<br />

<br />

ErP0<br />

...<br />

ErP19<br />

<br />

FAn1<br />

<br />

Fault <strong>de</strong>tection and elimination<br />

Fault messages<br />

PC 1) Error<br />

Cause<br />

68 Communication Participant does respond or is<br />

fault during not available<br />

remote parameter<br />

setting via system<br />

bus (C0370)<br />

(configurable in<br />

C0126)<br />

91 External fault<br />

(TRIP−SET)<br />

−<br />

Communication<br />

abort betwe<strong>en</strong><br />

keypad and basic<br />

<strong>de</strong>vice<br />

For operation with application<br />

I/O:<br />

Faulty parameter setting of<br />

parameter set changeover<br />

A digital input assigned to the<br />

TRIP−Set function has be<strong>en</strong><br />

activated.<br />

Various<br />

8<br />

Remedy<br />

Check whether bus terminator<br />

available<br />

Check scre<strong>en</strong> contact of the<br />

cables<br />

Check PE connection<br />

Check bus load, if necessary,<br />

reduce the baud rate<br />

In all parameter sets the signal<br />

"parameter set changeover"<br />

(C0410/13, C0410/14) must be<br />

combined with the same source<br />

Check external <strong>en</strong>co<strong>de</strong>r<br />

Contact L<strong>en</strong>ze<br />

95 E<strong>82</strong>ZMV fan Fan module is <strong>de</strong>fect Replace fan module<br />

module (only <strong>82</strong>00<br />

<strong>motec</strong><br />

FAn1 −<br />

3 ... 7,5 <strong>kW</strong>)<br />

TRIP or warning Fan module is not connected Connect fan module<br />

configurable un<strong>de</strong>r<br />

Check wiring<br />

C0608<br />

H05<br />

<br />

105 Internal fault Contact L<strong>en</strong>ze<br />

id1<br />

<br />

LP1<br />

<br />

140 Faulty parameter<br />

i<strong>de</strong>ntification<br />

32 Fault in motor<br />

phase<br />

(is displayed if<br />

C0597 = 1)<br />

LP1 1<strong>82</strong> Fault in motor<br />

phase<br />

(is displayed if<br />

C0597 = 2)<br />

LU<br />

<br />

OC1<br />

<br />

Motor not connected<br />

Failure of one/several<br />

motor phase(s)<br />

Motor curr<strong>en</strong>t too low<br />

Connect motor<br />

Check motor cables<br />

Check V min boost<br />

Connect motor to<br />

corresponding power or adapt<br />

the motor un<strong>de</strong>r C0599.<br />

− DC−bus Mains voltage too low Check mains voltage<br />

un<strong>de</strong>rvoltage DC−bus voltage too low Check supply module<br />

400 V controller connected to<br />

240 V mains<br />

Connect controller to the<br />

appropriate mains voltage<br />

11 Short circuit Short circuit Find reason for short circuit;<br />

check motor cable<br />

Check braking resistor and<br />

cable for braking resistor<br />

Excessive capacitive charging<br />

curr<strong>en</strong>t of the motor cable<br />

Use shorter motor cables with<br />

lower charging curr<strong>en</strong>t<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 127


8<br />

Keypad<br />

OC2<br />

<br />

OC3<br />

<br />

OC4<br />

<br />

OC5<br />

<br />

OC6<br />

<br />

OH<br />

<br />

OH<br />

<br />

OH3<br />

<br />

OH4<br />

<br />

Fault <strong>de</strong>tection and elimination<br />

Fault messages<br />

PC 1) Error<br />

Cause<br />

Remedy<br />

12 Earth fault Groun<strong>de</strong>d motor phase Check motor, check motor cable<br />

Excessive capacitive charging Use shorter motor cables with<br />

curr<strong>en</strong>t of the motor cable lower charging curr<strong>en</strong>t<br />

Deactivate earth−fault <strong>de</strong>tection for<br />

testing purposes<br />

13 Overload inverter<br />

during<br />

acceleration or<br />

short circuit<br />

14 Overload controller<br />

during<br />

<strong>de</strong>celeration<br />

15 Controller overload<br />

in stationary<br />

operation<br />

16 Motor overload<br />

(I 2 x t overload)<br />

50 Heatsink<br />

temperature<br />

> +85 °C<br />

− Heatsink<br />

temperature<br />

> +80 °C<br />

53 PTC monitoring<br />

(TRIP)<br />

(is displayed if<br />

C0119 = 1 or 4)<br />

54 Controller<br />

overtemperature<br />

OH51 203 PTC monitoring<br />

(is displayed if<br />

C0119 = 2 or 5)<br />

Acceleration time too short<br />

(C0012)<br />

Defective motor cable<br />

Interturn fault in the motor<br />

Deceleration time set too short<br />

(C0013)<br />

Frequ<strong>en</strong>t and long overload<br />

Motor is thermally overloa<strong>de</strong>d,<br />

for instance, because of<br />

impermissible continuous<br />

curr<strong>en</strong>t<br />

<strong>fr</strong>equ<strong>en</strong>t or too long<br />

acceleration processes<br />

Ambi<strong>en</strong>t temperature too high<br />

Increase acceleration time<br />

Check drive selection<br />

Check wiring<br />

Check motor<br />

Increase <strong>de</strong>celeration time<br />

Check size of external brake<br />

resistor<br />

Check drive selection<br />

<br />

<br />

Check drive selection<br />

Check setting of C0120<br />

Allow controller to cool and <strong>en</strong>sure<br />

better v<strong>en</strong>tilation<br />

Heatsink very dirty<br />

Clean heatsink<br />

Impermissibly high curr<strong>en</strong>ts or Check drive selection<br />

too <strong>fr</strong>equ<strong>en</strong>t and too long<br />

acceleration<br />

Check load, if necessary,<br />

replace <strong>de</strong>fective bearings<br />

Motor too hot because of Check drive selection<br />

excessive curr<strong>en</strong>ts or <strong>fr</strong>equ<strong>en</strong>t<br />

and too long accelerations<br />

PTC not connected<br />

Connect PTC or switch off<br />

monitoring<br />

Controller too hot insi<strong>de</strong> Reduce controller load<br />

Improve cooling<br />

Check fan in the controller<br />

Motor too hot because of Check drive selection<br />

excessive curr<strong>en</strong>ts or <strong>fr</strong>equ<strong>en</strong>t<br />

and too long accelerations<br />

PTC not connected<br />

Connect PTC or switch off<br />

monitoring<br />

128<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Keypad<br />

OU<br />

<br />

OUE<br />

<br />

Pr<br />

<br />

Pr1<br />

<br />

Pr2<br />

<br />

Pr3<br />

<br />

Pr4<br />

<br />

Pr5<br />

<br />

Pt5<br />

<br />

rSt<br />

<br />

sd5<br />

<br />

sd7<br />

<br />

Fault <strong>de</strong>tection and elimination<br />

Fault messages<br />

PC 1) Error<br />

Cause<br />

Remedy<br />

− DC−bus Mains voltage too high Check voltage supply<br />

overvoltage<br />

22 (Warning or TRIP Braking operation Prolong <strong>de</strong>celeration times.<br />

configurable un<strong>de</strong>r<br />

Operation with external brake<br />

C0310)<br />

resistor:<br />

– Check dim<strong>en</strong>sioning,<br />

connection and cable of the<br />

brake resistor.<br />

– Increase the <strong>de</strong>celeration<br />

times<br />

75 Faulty parameter<br />

transfer wh<strong>en</strong><br />

using the keypad<br />

72 Wrong PAR1<br />

transfer wh<strong>en</strong><br />

using the keypad.<br />

73 Wrong PAR2<br />

transfer wh<strong>en</strong><br />

using the keypad.<br />

77 Wrong PAR3<br />

transfer wh<strong>en</strong><br />

using the keypad.<br />

78 Wrong PAR4<br />

transfer wh<strong>en</strong><br />

using the keypad.<br />

Earth leakage on the motor<br />

si<strong>de</strong><br />

All parameter sets are<br />

<strong>de</strong>fective<br />

PAR1 is <strong>de</strong>fective.<br />

PAR2 is <strong>de</strong>fective.<br />

PAR3 is <strong>de</strong>fective<br />

PAR4 is <strong>de</strong>fective<br />

79 Internal fault EEPROM is <strong>de</strong>fective Contact L<strong>en</strong>ze<br />

81 Time fault during<br />

parameter set<br />

transfer<br />

76 Faulty auto−TRIP<br />

reset<br />

85 Wire breakage<br />

analog input 1<br />

87 Wire breakage<br />

analog input 2<br />

Data flow <strong>fr</strong>om keypad or PC<br />

interrupted, e. g. keypad was<br />

disconnected during transfer<br />

More than 8 fault messages in<br />

10 minutes<br />

Curr<strong>en</strong>t at analog input < 4<br />

mA at setpoint range<br />

4 ... 20 mA<br />

8<br />

Check motor cable and motor for<br />

earth fault (disconnect motor <strong>fr</strong>om<br />

inverter)<br />

It is absolutely necessary to repeat<br />

the data transfer or load the L<strong>en</strong>ze<br />

setting before <strong>en</strong>abling the<br />

controller.<br />

It is absolutely necessary to repeat<br />

the data transfer or load the L<strong>en</strong>ze<br />

setting before <strong>en</strong>abling the<br />

controller.<br />

Dep<strong>en</strong>ds on the error message<br />

Close circuit at analog input<br />

1) LECOM−fault number, display in parameter setting program Global Drive Control (GDC)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 129


Ce fascicule s’applique aux convertisseurs <strong>82</strong>00 <strong>motec</strong> <strong>de</strong>s versions suivantes<br />

E<strong>82</strong>MV xxx _ 4 B001 XX 1x 3x<br />

Type<br />

551 = 550 W<br />

751 = 750 W<br />

152 = 1.5 <strong>kW</strong><br />

222 = <strong>2.2</strong> <strong>kW</strong><br />

4 = 400 V Version du matériel Version du<br />

logiciel<br />

l<br />

<strong>82</strong>00mot166<br />

Remarque importante !<br />

Les mises à jours <strong>de</strong> logiciels et les docum<strong>en</strong>tations réc<strong>en</strong>tes<br />

relatives aux produits L<strong>en</strong>ze sont disponibles dans la zone<br />

"Downloads" (téléchargem<strong>en</strong>t) du site internet :<br />

http://www.L<strong>en</strong>ze.com


PS<br />

<br />

<br />

V<br />

%sh<br />

Lo<br />

PE<br />

U1 V 1 W1<br />

V2 U2 2 W<br />

Mise <strong>en</strong> service du <strong>82</strong>00 <strong>motec</strong> sans module <strong>de</strong> fonction<br />

<br />

<br />

<br />

<br />

Le <strong>82</strong>00 <strong>motec</strong> ne peut fonctionner que si le capot<br />

<strong>de</strong> protection FIF est <strong>en</strong>fiché (état à la livraison) !<br />

– En abs<strong>en</strong>ce du capot <strong>de</strong> protection FIF, le <strong>82</strong>00<br />

<strong>motec</strong> est bloqué (clavier : ).<br />

Sans module <strong>de</strong> fonction, le <strong>82</strong>00 <strong>motec</strong> ne dispose<br />

pas <strong>de</strong> bornier <strong>de</strong> comman<strong>de</strong>. Le démarrage et<br />

l’arrêt peuv<strong>en</strong>t alors être réalisés par<br />

coupure/branchem<strong>en</strong>t réseau.<br />

La fonction permet <strong>de</strong> sauvegar<strong>de</strong>r la consigne<br />

au mom<strong>en</strong>t <strong>de</strong> l’interruption <strong>en</strong> cas <strong>de</strong> coupure<br />

réseau ou d’interruptions <strong>de</strong> fonctionnem<strong>en</strong>t.<br />

L’<strong>en</strong>traînem<strong>en</strong>t redémarre automatiquem<strong>en</strong>t dès la<br />

mise sous t<strong>en</strong>sion !<br />

Si l’<strong>en</strong>traînem<strong>en</strong>t ne démarre pas au point ( <br />

n’est pas éteint), appuyer sur afin <strong>de</strong><br />

débloquer le <strong>82</strong>00 <strong>motec</strong>.<br />

A<br />

<strong>82</strong>00mot146<br />

E<strong>82</strong>ZWLxxx<br />

L1/L2/L3/PE<br />

rpm<br />

°C<br />

8888888 8<br />

m A<br />

<br />

<br />

<br />

<br />

<br />

E<strong>82</strong>ZBB<br />

88888<br />

<br />

Hi Hz<br />

1 2<br />

<br />

<br />

0140<br />

3<br />

5000<br />

Hz<br />

AIF<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

0....+50 Hz<br />

<strong>82</strong>00mot170<br />

0....- 50 Hz<br />

Etape Remarque Voir chapitre<br />

<br />

<br />

<br />

Relier le clavier <strong>de</strong><br />

comman<strong>de</strong> avec boîtier<br />

au <strong>motec</strong>. Enficher le<br />

connecteur <strong>de</strong> câble dans<br />

l’interface AIF du <strong>motec</strong>.<br />

Brancher la t<strong>en</strong>sion<br />

réseau.<br />

Démarrage automatique<br />

possible !<br />

Régler la consigne via la<br />

fonction .<br />

Le clavier <strong>de</strong> comman<strong>de</strong> avec boîtier déporté et le câble <strong>de</strong><br />

liaison ne sont pas compris dans l’équipem<strong>en</strong>t standard.<br />

Le variateur est prêt à fonctionner après <strong>en</strong>v. 1 s.<br />

Clavier <strong>de</strong> comman<strong>de</strong> : <br />

Activer .<br />

S<strong>en</strong>s horaire<br />

S<strong>en</strong>s antihoraire<br />

<br />

Problèmes <strong>de</strong> mise <strong>en</strong> service ou défauts <strong>de</strong> fonctionnem<strong>en</strong>t ?<br />

est éteint. L’<strong>en</strong>traînem<strong>en</strong>t peut<br />

tourner.<br />

La <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie est affichée.<br />

7


i<br />

Sommaire<br />

Consignes <strong>de</strong> sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133<br />

Machines à courant triphasé . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

Dangers résiduels, prés<strong>en</strong>tation <strong>de</strong>s consignes <strong>de</strong> sécurité . . . . . . . . . . . 142<br />

Spécifications techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

Normes et conditions ambiantes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145<br />

Caractéristiques électriques générales . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

Encombrem<strong>en</strong>ts, conception mécanique . . . . . . . . . . . . . . . . . . . . . . . . 147<br />

<strong>motec</strong> avec moteur ou motoréducteur . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

Montage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148<br />

Câblage conforme CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150<br />

Montage au mur/sur le bâti <strong>de</strong> la machine . . . . . . . . . . . . . . . . . . . . . . . 151<br />

Equipem<strong>en</strong>t livré . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151<br />

Préparatifs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />

Raccor<strong>de</strong>m<strong>en</strong>t moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154<br />

Câblage conforme CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156<br />

Montage sur le moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

Equipem<strong>en</strong>t livré . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157<br />

Préparatifs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158<br />

Raccor<strong>de</strong>m<strong>en</strong>t moteur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

Câblage conforme CEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160<br />

Installation électrique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162<br />

Raccor<strong>de</strong>m<strong>en</strong>t réseau/résistance <strong>de</strong> <strong>fr</strong>einage . . . . . . . . . . . . . . . . . . . . . 162<br />

Raccor<strong>de</strong>m<strong>en</strong>t sortie relais . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164<br />

Montage module <strong>de</strong> fonction (option) . . . . . . . . . . . . . . . . . . . . . . . . . . . 165<br />

Assemblage du <strong>motec</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166<br />

Mise <strong>en</strong> service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

Avant la première mise <strong>en</strong> service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168<br />

Sélection du mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t adapté . . . . . . . . . . . . . . . . . . . . 169<br />

Paramétrage à l’ai<strong>de</strong> du clavier <strong>de</strong> comman<strong>de</strong> E<strong>82</strong>ZBB . . . . . . . . . . . . . . 171<br />

Fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe linéaire . . . . . . . . . . . . . . . . . . . . . . 172<br />

Contrôle vectoriel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service . . . . . . . . . . . . . . . . . . . . . . . 180<br />

Détection et élimination <strong>de</strong>s défauts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192<br />

Anomalie <strong>de</strong> fonctionnem<strong>en</strong>t <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t . . . . . . . . . . . . . . . . . . . 192<br />

Messages <strong>de</strong> défaut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194<br />

132<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

1<br />

Instructions générales <strong>de</strong> sécurité et d’utilisation<br />

(conformes à la directive Basse T<strong>en</strong>sion 73/23/CEE)<br />

Généralités<br />

Selon leur <strong>de</strong>gré <strong>de</strong> protection, les variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

(convertisseurs <strong>de</strong> <strong>fr</strong>équ<strong>en</strong>ce, servovariateurs, variateurs <strong>de</strong> vitesse CC)<br />

peuv<strong>en</strong>t avoir, p<strong>en</strong>dant leur fonctionnem<strong>en</strong>t, <strong>de</strong>s parties accessibles sous<br />

t<strong>en</strong>sion, év<strong>en</strong>tuellem<strong>en</strong>t <strong>en</strong> mouvem<strong>en</strong>t ou <strong>en</strong> rotation. Les surfaces<br />

peuv<strong>en</strong>t aussi être brûlantes.<br />

La suppression non autorisée <strong>de</strong>s protections prescrites, un usage non<br />

conforme à la fonction, une installation défectueuse ou une manoeuvre<br />

erronée peuv<strong>en</strong>t <strong>en</strong>traîner <strong>de</strong>s dommages corporels et matériels graves.<br />

Pour obt<strong>en</strong>ir <strong>de</strong>s informations complém<strong>en</strong>taires, consulter la<br />

docum<strong>en</strong>tation.<br />

Tous travaux relatifs au transport, à l’installation, à la mise <strong>en</strong> service et à la<br />

maint<strong>en</strong>ance doiv<strong>en</strong>t être exécutés par du personnel qualifié et habilité (voir<br />

CEI 364 ou CENELEC HD 384 ou DIN VDE 0100 et CEI 664 ou<br />

DIN VDE 0110, ainsi que les prescriptions nationales <strong>de</strong> prév<strong>en</strong>tion<br />

d’acci<strong>de</strong>nts).<br />

Au s<strong>en</strong>s <strong>de</strong>s prés<strong>en</strong>tes instructions <strong>de</strong> sécurité générales, on <strong>en</strong>t<strong>en</strong>d par<br />

personnel qualifié <strong>de</strong>s personnes compét<strong>en</strong>tes <strong>en</strong> matière d’installation, <strong>de</strong><br />

montage, <strong>de</strong> mise <strong>en</strong> service et <strong>de</strong> fonctionnem<strong>en</strong>t du produit et possédant<br />

les qualifications correspondant à leurs activités.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 133


1<br />

Consignes <strong>de</strong> sécurité<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

Utilisation conforme à l’application<br />

Les variateurs <strong>de</strong> vitesse sont <strong>de</strong>s composants <strong>de</strong>stinés à être incorporés<br />

dans <strong>de</strong>s installations ou machines électriques. Ils ne constitu<strong>en</strong>t pas <strong>de</strong>s<br />

appareils domestiques, mais <strong>de</strong>s élém<strong>en</strong>ts à usage industriel et<br />

professionnel au s<strong>en</strong>s <strong>de</strong> la norme EN 61000−3−2. Cette docum<strong>en</strong>tation<br />

conti<strong>en</strong>t <strong>de</strong>s indications au sujet du respect <strong>de</strong>s valeurs limites selon<br />

EN 61000−3−2.<br />

Lorsque les variateurs <strong>de</strong> vitesse sont incorporés dans une machine, leur<br />

mise <strong>en</strong> service (c’est−à−dire leur mise <strong>en</strong> fonctionnem<strong>en</strong>t conformém<strong>en</strong>t à<br />

leur fonction) est interdite tant que la conformité <strong>de</strong> la machine avec les<br />

dispositions <strong>de</strong> la directive 98/37/CE (directive sur les machines) n’a pas été<br />

vérifiée ; respecter la norme EN 60204.<br />

Leur mise <strong>en</strong> service (c’est−à−dire leur mise <strong>en</strong> fonctionnem<strong>en</strong>t<br />

conformém<strong>en</strong>t à leur fonction) n’est admise que si les dispositions <strong>de</strong> la<br />

directive sur la compatibilité électromagnétique (89/336/CEE) sont<br />

respectées.<br />

Les variateurs <strong>de</strong> vitesse répon<strong>de</strong>nt aux exig<strong>en</strong>ces <strong>de</strong> la directive Basse<br />

T<strong>en</strong>sion 73/23/CEE. Les normes harmonisées série EN 50178/DIN VDE<br />

0160 sont appliquées aux variateurs <strong>de</strong> vitesse.<br />

Les caractéristiques techniques et les indications relatives aux conditions<br />

<strong>de</strong> raccor<strong>de</strong>m<strong>en</strong>t selon la plaque signalétique et la docum<strong>en</strong>tation doiv<strong>en</strong>t<br />

obligatoirem<strong>en</strong>t être respectées.<br />

Att<strong>en</strong>tion ! Les variateurs <strong>de</strong> vitesse sont <strong>de</strong>s produits <strong>de</strong> commerce à<br />

disponibilité restreinte selon EN 61800−3. Dans un <strong>en</strong>vironnem<strong>en</strong>t<br />

rési<strong>de</strong>ntiel, ces produits risqu<strong>en</strong>t <strong>de</strong> provoquer <strong>de</strong>s interfér<strong>en</strong>ces radio.<br />

Dans ce cas, il peut s’avérer nécessaire <strong>de</strong> mettre <strong>en</strong> œuvre <strong>de</strong>s mesures<br />

appropriées.<br />

Transport, stockage<br />

Les indications relatives au transport, au stockage et au maniem<strong>en</strong>t<br />

approprié doiv<strong>en</strong>t être respectées.<br />

Les conditions climatiques selon EN 50178 doiv<strong>en</strong>t être respectées.<br />

134<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

Installation<br />

L’installation et le re<strong>fr</strong>oidissem<strong>en</strong>t <strong>de</strong>s variateurs <strong>de</strong> vitesse doiv<strong>en</strong>t<br />

répondre aux prescriptions <strong>de</strong> la docum<strong>en</strong>tation fournie avec le produit.<br />

Manipuler avec précaution et éviter toute contrainte mécanique. Lors du<br />

transport et <strong>de</strong> la manut<strong>en</strong>tion, veiller à ne pas déformer les composants ou<br />

modifier les distances d’isolem<strong>en</strong>t. Ne pas toucher les composants<br />

électroniques et les contacts électriques.<br />

Les variateurs <strong>de</strong> vitesse comport<strong>en</strong>t <strong>de</strong>s pièces s<strong>en</strong>sibles aux contraintes<br />

électrostatiques et facilem<strong>en</strong>t <strong>en</strong>dommageables par un maniem<strong>en</strong>t<br />

inadéquat. Ne pas <strong>en</strong>dommager ou détruire <strong>de</strong>s composants électroniques<br />

sous risque <strong>de</strong> nuire à la santé !<br />

Raccor<strong>de</strong>m<strong>en</strong>t électrique<br />

Lorsque <strong>de</strong>s travaux sont effectués sur le variateur <strong>de</strong> vitesse sous t<strong>en</strong>sion,<br />

les prescriptions nationales <strong>en</strong> vigueur pour la prév<strong>en</strong>tion d’acci<strong>de</strong>nts<br />

doiv<strong>en</strong>t être respectées (par exemple VBG 4).<br />

L’installation électrique doit être exécutée <strong>en</strong> conformité avec les<br />

prescriptions proposées (par exemple sections <strong>de</strong>s conducteurs,<br />

protection par coupe−circuit à fusibles, raccor<strong>de</strong>m<strong>en</strong>t du conducteur <strong>de</strong><br />

protection). Des r<strong>en</strong>seignem<strong>en</strong>ts plus détaillés figur<strong>en</strong>t dans la<br />

docum<strong>en</strong>tation.<br />

Les indications concernant une installation conforme aux exig<strong>en</strong>ces <strong>de</strong><br />

compatibilité électromagnétique, tels que blindage, mise à la terre,<br />

prés<strong>en</strong>ce <strong>de</strong> filtres et pose adéquate <strong>de</strong>s câbles et conducteurs, figur<strong>en</strong>t<br />

dans la docum<strong>en</strong>tation qui accompagne les variateurs <strong>de</strong> vitesse. Ces<br />

indications doiv<strong>en</strong>t égalem<strong>en</strong>t être respectées pour les variateurs avec<br />

marquage CE. Le respect <strong>de</strong>s valeurs limites imposées par la législation sur<br />

la CEM relève <strong>de</strong> la responsabilité du constructeur <strong>de</strong> l’installation ou <strong>de</strong> la<br />

machine.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 135


1<br />

Consignes <strong>de</strong> sécurité<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

Fonctionnem<strong>en</strong>t<br />

Les installations dans lesquelles sont incorporés <strong>de</strong>s variateurs <strong>de</strong> vitesse<br />

doiv<strong>en</strong>t être équipées <strong>de</strong> dispositifs <strong>de</strong> protection et <strong>de</strong> surveillance<br />

supplém<strong>en</strong>taires prévus par les prescriptions <strong>de</strong> sécurité appropriées <strong>en</strong><br />

vigueur, telles que la loi sur le matériel technique, les prescriptions pour la<br />

prév<strong>en</strong>tion d’acci<strong>de</strong>nts, etc. Il est possible qu’il faille adapter les variateurs<br />

<strong>de</strong> vitesse. Respecter les indications à ce sujet figurant dans la<br />

docum<strong>en</strong>tation.<br />

Après coupure <strong>de</strong> l’alim<strong>en</strong>tation du variateur, ne pas toucher<br />

immédiatem<strong>en</strong>t aux élém<strong>en</strong>ts conducteurs et aux borniers <strong>de</strong> puissance<br />

précé<strong>de</strong>mm<strong>en</strong>t sous t<strong>en</strong>sion, <strong>en</strong> raison <strong>de</strong>s con<strong>de</strong>nsateurs év<strong>en</strong>tuellem<strong>en</strong>t<br />

chargés. A ce sujet, t<strong>en</strong>ir compte <strong>de</strong>s informations indiquées sur les<br />

variateurs <strong>de</strong> vitesse.<br />

P<strong>en</strong>dant le fonctionnem<strong>en</strong>t, les capots <strong>de</strong> protection et portes doiv<strong>en</strong>t rester<br />

fermés.<br />

Remarque concernant les installations homologuées UL fonctionnant<br />

avec variateurs <strong>de</strong> vitesse : les instructions "UL warnings" sont <strong>de</strong>s<br />

indications uniquem<strong>en</strong>t applicables aux installations UL. Cette notice<br />

compr<strong>en</strong>d <strong>de</strong>s indications spéciales au sujet <strong>de</strong> la norme UL.<br />

Arrêt sécurisé −14−<br />

La variante V004 <strong>de</strong>s variateurs <strong>de</strong> vitesse 9300 et 9300 vector, la variante<br />

x4x <strong>de</strong>s variateurs <strong>de</strong> vitesse <strong>82</strong>00 vector et les modules d’axe ECSxAxxx<br />

intègr<strong>en</strong>t la fonction "arrêt sécurisé" qui assure la protection contre un<br />

démarrage incontrôlé selon l’annexe I n° 1.2.7 <strong>de</strong> la directive CE relative aux<br />

machines 98/37/CE, DIN EN 954−1 catégorie 3 et DIN EN 1037. Respecter<br />

impérativem<strong>en</strong>t toutes les indications concernant la fonction "arrêt<br />

sécurisé" figurant dans cette docum<strong>en</strong>tation.<br />

Entreti<strong>en</strong> et maint<strong>en</strong>ance<br />

Les variateurs ne nécessit<strong>en</strong>t aucun <strong>en</strong>treti<strong>en</strong> à condition <strong>de</strong> respecter les<br />

conditions d’utilisation prescrites.<br />

Dans <strong>de</strong>s ambiances poussiéreuses, il se peut que les surfaces <strong>de</strong><br />

re<strong>fr</strong>oidissem<strong>en</strong>t du variateur soi<strong>en</strong>t salies ou que les grilles d’aération soi<strong>en</strong>t<br />

bouchées. Il convi<strong>en</strong>t <strong>de</strong> procé<strong>de</strong>r à un nettoyage régulier <strong>de</strong>s surfaces <strong>de</strong><br />

re<strong>fr</strong>oidissem<strong>en</strong>t et <strong>de</strong>s grilles d’aération. Pour le nettoyage, ne pas utiliser<br />

d’objets pointus ou tranchants !<br />

136<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Variateurs <strong>de</strong> vitesse L<strong>en</strong>ze<br />

Traitem<strong>en</strong>t <strong>de</strong>s déchets<br />

Les métaux et les matières plastiques sont recyclables. Les cartes<br />

électroniques sont à évacuer selon un traitem<strong>en</strong>t spécifique.<br />

T<strong>en</strong>ir impérativem<strong>en</strong>t compte <strong>de</strong>s instructions <strong>de</strong> sécurité et<br />

d’utilisation spécifiques au produit cont<strong>en</strong>ues dans ce docum<strong>en</strong>t !<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 137


1<br />

Consignes <strong>de</strong> sécurité<br />

Machines à courant triphasé<br />

Instructions générales <strong>de</strong> sécurité et d’utilisation relatives aux<br />

moteurs L<strong>en</strong>ze<br />

(conformes à la directive Basse T<strong>en</strong>sion 73/23/CEE)<br />

Généralités<br />

Les machines BT comport<strong>en</strong>t <strong>de</strong>s parties dangereuses, sous t<strong>en</strong>sion et<br />

tournantes, ainsi que, le cas échéant, <strong>de</strong>s surfaces brûlantes. L’<strong>en</strong>semble<br />

<strong>de</strong>s opérations relatives au transport, au raccor<strong>de</strong>m<strong>en</strong>t, à la mise <strong>en</strong> service<br />

et à la maint<strong>en</strong>ance doit être exécuté par du personnel qualifié et<br />

responsable (voir EN 50110−1 (VDE 0105−100) ; CEI 60364). Tout<br />

comportem<strong>en</strong>t ou maniem<strong>en</strong>t inapproprié est susceptible <strong>de</strong> causer <strong>de</strong>s<br />

dommages corporels et matériels graves.<br />

Avec <strong>de</strong>s machines synchrones, <strong>de</strong>s t<strong>en</strong>sions induites sont prés<strong>en</strong>tes, lors<br />

<strong>de</strong> la rotation, sur <strong>de</strong>s bornes non protégées.<br />

Utilisation conforme à l’application<br />

Ces machines BT sont <strong>de</strong>stinées à être utilisées dans <strong>de</strong>s installations<br />

industrielles. Elles répon<strong>de</strong>nt aux normes harmonisées série EN 60034<br />

(VDE O53O). Leur utilisation dans <strong>de</strong>s atmosphères explosives est<br />

interdite, à moins qu’elles ne soi<strong>en</strong>t expressém<strong>en</strong>t prévues à cet effet<br />

(respecter les indications supplém<strong>en</strong>taires).<br />

Sans mesure <strong>de</strong> protection supplém<strong>en</strong>taire, les machines dotées d’un<br />

indice <strong>de</strong> protection IP23 ne doiv<strong>en</strong>t <strong>en</strong> aucun cas être utilisées <strong>en</strong><br />

<strong>en</strong>vironnem<strong>en</strong>t extérieur. Les machines à re<strong>fr</strong>oidissem<strong>en</strong>t par air sont<br />

conçues pour <strong>de</strong>s températures ambiantes <strong>de</strong> −15 °C ou −10 °C à +40 °C et<br />

<strong>de</strong>s altitu<strong>de</strong>s d’implantation <strong>de</strong> 1000 m au−<strong>de</strong>ssus du niveau <strong>de</strong> la mer, <strong>de</strong><br />

−20 °C à +40 °C sans <strong>fr</strong>ein ou avec <strong>fr</strong>ein à manque <strong>de</strong> courant, sans<br />

v<strong>en</strong>tilateur ou avec autov<strong>en</strong>tilation, <strong>de</strong> −15 °C à +40 °C avec <strong>fr</strong>ein à aimant<br />

perman<strong>en</strong>t et <strong>de</strong> −10 °C à +40 °C avec motov<strong>en</strong>tilateur. Respecter<br />

impérativem<strong>en</strong>t les indications év<strong>en</strong>tuellem<strong>en</strong>t diverg<strong>en</strong>tes figurant sur la<br />

plaque signalétique. Les conditions sur site doiv<strong>en</strong>t être <strong>en</strong>tièrem<strong>en</strong>t<br />

conformes aux indications figurant sur la plaque signalétique.<br />

Les machines BT sont <strong>de</strong>s composants <strong>de</strong>stinés à être incorporés dans <strong>de</strong>s<br />

machines au s<strong>en</strong>s <strong>de</strong> la directive sur les machines 98/37/CE. Leur mise <strong>en</strong><br />

service est interdite tant que la conformité du produit final avec cette<br />

directive n’a pas été établie (respecter <strong>en</strong>tre autres la norme EN 60204−1).<br />

Les <strong>fr</strong>eins installés ne sont pas <strong>de</strong>s <strong>fr</strong>eins <strong>de</strong> sécurité. On ne peut pas exclure<br />

une diminution du couple <strong>en</strong> raison <strong>de</strong> phénomènes dégradants non<br />

influ<strong>en</strong>çables. (exemple : pénétration d’huile à cause <strong>de</strong> la défaillance <strong>de</strong> la<br />

bague d’étanchéité d’arbre côté A).<br />

138<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Machines à courant triphasé<br />

Transport, stockage<br />

D’év<strong>en</strong>tuels dommages constatés après la livraison doiv<strong>en</strong>t être signalés<br />

immédiatem<strong>en</strong>t à l’<strong>en</strong>treprise <strong>de</strong> transport ; si nécessaire, la mise <strong>en</strong> service<br />

doit être annulée. Les dispositifs <strong>de</strong> transport vissés doiv<strong>en</strong>t être bi<strong>en</strong><br />

serrés. Ils sont dim<strong>en</strong>sionnés <strong>en</strong> fonction du poids <strong>de</strong> la machine BT ; par<br />

conséqu<strong>en</strong>t, aucune charge supplém<strong>en</strong>taire ne doit leur être appliquée. En<br />

cas <strong>de</strong> besoin, utiliser <strong>de</strong>s moy<strong>en</strong>s auxiliaires <strong>de</strong> transport appropriés <strong>de</strong><br />

dim<strong>en</strong>sions adéquates (par exemple chariot élévateur).<br />

Avant la mise <strong>en</strong> service, <strong>en</strong>lever les sécurités <strong>de</strong> transport. Les réutiliser<br />

pour d’autres opérations <strong>de</strong> transport. Lorsque <strong>de</strong>s machines BT sont<br />

<strong>en</strong>treposées, veiller à ce que l’<strong>en</strong>vironnem<strong>en</strong>t soit sec, exempt <strong>de</strong> poussière<br />

et, dans la mesure du possible, <strong>de</strong> vibrations (v eff 0,2 mm/s) (risque<br />

d’<strong>en</strong>dommagem<strong>en</strong>t <strong>de</strong>s roulem<strong>en</strong>ts suite à l’arrêt prolongé <strong>de</strong>s machines).<br />

Avant la mise <strong>en</strong> service, mesurer la résistance d’isolem<strong>en</strong>t. En cas <strong>de</strong><br />

valeurs mesurées 1 k par volt <strong>de</strong> t<strong>en</strong>sion nominale, sécher les<br />

<strong>en</strong>roulem<strong>en</strong>ts.<br />

Installation<br />

Veiller à une surface d’appui plane, une bonne fixation <strong>de</strong>s pattes, ou selon<br />

le cas, <strong>de</strong>s bri<strong>de</strong>s, et à un alignem<strong>en</strong>t précis <strong>en</strong> cas d’accouplem<strong>en</strong>t direct.<br />

Eviter que le montage ne provoque <strong>de</strong>s résonances dues à la <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong><br />

rotation et à la <strong>fr</strong>équ<strong>en</strong>ce d’alim<strong>en</strong>tation. Faire tourner le rotor manuellem<strong>en</strong>t<br />

pour détecter d’év<strong>en</strong>tuels bruits <strong>de</strong> fonctionnem<strong>en</strong>t anormaux. Vérifier le<br />

s<strong>en</strong>s <strong>de</strong> rotation à l’état désaccouplé (t<strong>en</strong>ir compte <strong>de</strong> ce qui est dit dans le<br />

paragraphe "Raccor<strong>de</strong>m<strong>en</strong>t électrique").<br />

Ne monter et démonter les poulies et accouplem<strong>en</strong>ts qu’à l’ai<strong>de</strong> <strong>de</strong><br />

dispositifs appropriés (chauffés !) et les protéger contre les chocs.<br />

Respecter les t<strong>en</strong>sions <strong>de</strong> courroie préconisées par les fabricants.<br />

Les machines sont équilibrées par <strong>de</strong>mi−clavette. L’équilibrage <strong>de</strong><br />

l’accouplem<strong>en</strong>t doit égalem<strong>en</strong>t se faire par <strong>de</strong>mi−clavette. Faire sortir la<br />

clavette <strong>de</strong> sa rainure.<br />

Le cas échéant, réaliser les raccords <strong>de</strong> conduits nécessaires aux ouies<br />

d’air. Les modèles avec bout d’arbre ori<strong>en</strong>té vers le bas doiv<strong>en</strong>t être<br />

recouverts, lors du montage, pour empêcher la chute <strong>de</strong> corps étrangers<br />

dans le v<strong>en</strong>tilateur. La v<strong>en</strong>tilation ne doit pas être <strong>en</strong>travée et l’air évacué −<br />

aussi par un <strong>en</strong>semble voisin − ne doit pas être immédiatem<strong>en</strong>t réutilisé.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 139


1<br />

Consignes <strong>de</strong> sécurité<br />

Machines à courant triphasé<br />

Raccor<strong>de</strong>m<strong>en</strong>t électrique<br />

Les travaux ne doiv<strong>en</strong>t être effectués que par du personnel qualifié et<br />

habilité, la machine étant au repos, alim<strong>en</strong>tation coupée et protégée contre<br />

tout ré<strong>en</strong>cl<strong>en</strong>chem<strong>en</strong>t intempestif. Ceci vaut égalem<strong>en</strong>t pour les circuits<br />

auxiliaires (exemples : <strong>fr</strong>ein, co<strong>de</strong>ur, motov<strong>en</strong>tilateur).<br />

Vérifier l’abs<strong>en</strong>ce <strong>de</strong> t<strong>en</strong>sion !<br />

Tout dépassem<strong>en</strong>t <strong>de</strong>s tolérances selon les normes EN 60034−1 ;<br />

CEI 34 (VDE 0530−1) (t<strong>en</strong>sion ±5 %, <strong>fr</strong>équ<strong>en</strong>ce ±2 %, forme et symétrie<br />

<strong>de</strong>s t<strong>en</strong>sions et courants) a pour effet une augm<strong>en</strong>tation <strong>de</strong><br />

l’échauffem<strong>en</strong>t et influe sur la compatibilité électromagnétique.<br />

Respecter les indications <strong>de</strong> couplage et les données <strong>de</strong> la plaque<br />

signalétique ainsi que le schéma <strong>de</strong> raccor<strong>de</strong>m<strong>en</strong>t dans la boîte à bornes.<br />

Le raccor<strong>de</strong>m<strong>en</strong>t doit être réalisé <strong>de</strong> manière à assurer une liaison électrique<br />

durable et sûre (pas <strong>de</strong> brins effilochés !) ; utiliser les embouts prévus à cet<br />

effet. Réaliser une connexion sécurisée du conducteur <strong>de</strong> protection. Serrer<br />

les prises à fond.<br />

Les distances dans l’air minimales <strong>en</strong>tre les parties nues sous t<strong>en</strong>sion et<br />

<strong>en</strong>tre celles−ci et la terre ne doiv<strong>en</strong>t pas être inférieures aux valeurs suivantes<br />

: 8 mm pour U N 550 V, 10 mm pour U N 725 V, 14 mm pour U N 1000 V.<br />

La boîte <strong>de</strong> connexion ne doit cont<strong>en</strong>ir ni corps étranger, ni poussière ni<br />

humidité. Les <strong>en</strong>trées <strong>de</strong> câbles non utilisées doiv<strong>en</strong>t être obturées, la boîte<br />

elle−même <strong>de</strong>vant être fermée <strong>de</strong> façon à être étanche à l’eau et à la<br />

poussière. Lors d’essai <strong>de</strong> fonctionnem<strong>en</strong>t sans élém<strong>en</strong>t d’<strong>en</strong>traînem<strong>en</strong>t,<br />

veiller à ce que la clavette soit immobilisée. Dans le cas <strong>de</strong>s machines BT<br />

munies <strong>de</strong> <strong>fr</strong>ein, vérifier le bon état <strong>de</strong> fonctionnem<strong>en</strong>t du <strong>fr</strong>ein avant la mise<br />

<strong>en</strong> service <strong>de</strong> la machine.<br />

140<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Machines à courant triphasé<br />

Fonctionnem<strong>en</strong>t<br />

Des vibrations <strong>de</strong> vitesse v eff 3,5 mm/s (P N 15 <strong>kW</strong>) ou 4,5 mm/s (P N > 15<br />

<strong>kW</strong>) <strong>en</strong> marche couplé sont sans conséqu<strong>en</strong>ce. En cas d’écart par rapport<br />

au fonctionnem<strong>en</strong>t normal − par exemple température élevée, bruit,<br />

vibrations − <strong>en</strong> rechercher l’origine. Le cas échéant, contacter le<br />

constructeur. En cas <strong>de</strong> doute, déconnecter la machine BT.<br />

En prés<strong>en</strong>ce <strong>de</strong> poussières abondantes, nettoyer régulièrem<strong>en</strong>t les ouies <strong>de</strong><br />

v<strong>en</strong>tilation.<br />

Les dispositifs <strong>de</strong> protection ne doiv<strong>en</strong>t pas être mis hors d’état <strong>de</strong> marche<br />

même lors <strong>de</strong> l’essai <strong>de</strong> fonctionnem<strong>en</strong>t.<br />

Une son<strong>de</strong> thermique installée ne constitue pas une protection totale <strong>de</strong> la<br />

machine, le cas échéant réduire le courant maximal. Réaliser une<br />

programmation via blocs fonction assurant une coupure après quelques<br />

secon<strong>de</strong>s <strong>de</strong> fonctionnem<strong>en</strong>t à I > In, surtout dans l’év<strong>en</strong>tualité d’un blocage<br />

du rotor.<br />

Les bagues d’etanchéité et les roulem<strong>en</strong>ts ont une durée <strong>de</strong> vie limitée.<br />

Les paliers à dispositif <strong>de</strong> regraissage doiv<strong>en</strong>t être regraissés lorsque la<br />

machine BT est <strong>en</strong> marche. Faire att<strong>en</strong>tion à la nature du lubrifiant ! Au cas<br />

où les trous <strong>de</strong> sortie <strong>de</strong> graisse serai<strong>en</strong>t obturés par <strong>de</strong>s bouchons (IP 54<br />

du côté d’<strong>en</strong>traînem<strong>en</strong>t, IP23 <strong>de</strong>s côtés <strong>en</strong>traînem<strong>en</strong>t et opposé à<br />

l’<strong>en</strong>traînem<strong>en</strong>t), <strong>en</strong>lever les bouchons avant la mise <strong>en</strong> service. Fermer les<br />

trous à l’ai<strong>de</strong> <strong>de</strong> graisse. Les roulem<strong>en</strong>ts à lubrification perman<strong>en</strong>te<br />

(roulem<strong>en</strong>t 2Z) doiv<strong>en</strong>t être changés après <strong>en</strong>viron 10 000 h à 20 000 h ou<br />

au plus tard après 3 à 4 années, ou <strong>en</strong>core suivant les indications du<br />

constructeur.<br />

1<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 141


1<br />

Consignes <strong>de</strong> sécurité<br />

Dangers résiduels, prés<strong>en</strong>tation <strong>de</strong>s consignes <strong>de</strong> sécurité<br />

Dangers résiduels<br />

Protection <strong>de</strong>s personnes<br />

Avant <strong>de</strong> procé<strong>de</strong>r aux travaux sur le variateur ou d’ouvrir l’appareil,<br />

couper le variateur du réseau. Les bornes <strong>de</strong> puissance U, V, W ; BR0,<br />

BR1, BR2 et les broches <strong>de</strong> l’interface FIF risquant d’être sous t<strong>en</strong>sion<br />

après coupure réseau, att<strong>en</strong>dre 3 minutes au minimum avant toute<br />

opération.<br />

– Après ouverture du <strong>motec</strong>, vérifier si les bornes <strong>de</strong> puissance L1, L2<br />

; U, V, W ; BR0, BR1, BR2, les sorties relais K11, K12, K14 et les<br />

broches <strong>de</strong> l’interface FIF sont hors t<strong>en</strong>sion.<br />

– Même le variateur coupé du réseau, les sorties relais K11, K12, K14<br />

peuv<strong>en</strong>t être sous t<strong>en</strong>sion.<br />

En utilisant la fonction (non protégée contre rupture <strong>de</strong> fil) Réglage du<br />

s<strong>en</strong>s <strong>de</strong> rotation" via le signal numérique CW/CCW (C0007 = −0− ...<br />

−13−, C0410/3 255) :<br />

– L’<strong>en</strong>traînem<strong>en</strong>t risque d’être inversé <strong>en</strong> cas <strong>de</strong> rupture <strong>de</strong> fil ou <strong>de</strong><br />

coupure <strong>de</strong> t<strong>en</strong>sion <strong>de</strong> comman<strong>de</strong>.<br />

En utilisant la fonction "redémarrage à la volée" (C0142 = −2−, −3−)<br />

avec <strong>de</strong>s machines à mom<strong>en</strong>t d’inertie et <strong>fr</strong>ottem<strong>en</strong>t faibles :<br />

– Après déblocage du variateur à l’arrêt, un démarrage ou une<br />

inversion du s<strong>en</strong>s inopinés peuv<strong>en</strong>t surv<strong>en</strong>ir.<br />

Le radiateur du <strong>motec</strong> peut atteindre une température >60 °C :<br />

– Ne pas toucher au radiateur sous risque <strong>de</strong> brûlures.<br />

Protection du moteur<br />

<br />

Certains réglages du variateur peuv<strong>en</strong>t induire une surchauffe du<br />

moteur connecté.<br />

– Exemples : fonctionnem<strong>en</strong>t prolongé du <strong>fr</strong>ein CC,<br />

– fonctionnem<strong>en</strong>t prolongé dans la plage <strong>de</strong>s basses vitesses pour<br />

<strong>de</strong>s moteurs autov<strong>en</strong>tilés.<br />

142<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Consignes <strong>de</strong> sécurité<br />

Dangers résiduels, prés<strong>en</strong>tation <strong>de</strong>s consignes <strong>de</strong> sécurité<br />

Protection <strong>de</strong> la machine/l’installation<br />

<br />

<br />

Les <strong>en</strong>traînem<strong>en</strong>ts peuv<strong>en</strong>t atteindre <strong>de</strong>s survitesses dangereuses<br />

(exemple : réglage <strong>de</strong> <strong>fr</strong>équ<strong>en</strong>ces <strong>de</strong> sortie élevées <strong>en</strong> utilisant <strong>de</strong>s<br />

moteurs et machines non adaptés).<br />

– Les convertisseurs <strong>de</strong> <strong>fr</strong>équ<strong>en</strong>ce <strong>82</strong>00 <strong>motec</strong> ne sont pas protégés<br />

contre <strong>de</strong> telles conditions <strong>de</strong> fonctionnem<strong>en</strong>t. Prévoir <strong>de</strong>s<br />

composants supplém<strong>en</strong>taires.<br />

Ne procé<strong>de</strong>r à la commutation <strong>de</strong>s contacteurs au niveau du câble<br />

moteur que variateur bloqué.<br />

En commutant les contacteurs au niveau du câble moteur avec le<br />

variateur débloqué,<br />

– les fonctions <strong>de</strong> surveillance du variateur risqu<strong>en</strong>t d’être activées,<br />

– le variateur risque d’être détruit si les conditions <strong>de</strong> fonctionnem<strong>en</strong>t<br />

sont défavorables.<br />

1<br />

Warnings!<br />

The <strong>de</strong>vice has no overspeed protection.<br />

Must be provi<strong>de</strong>d with external or remote overload protection.<br />

Suitable for use on a circuit capable of <strong>de</strong>livering not more<br />

than 5000 rms symmetrical amperes, 240 V maximum (240 V<br />

<strong>de</strong>vices) or 500 V maximum (400/500 V <strong>de</strong>vices) resp.<br />

Circuit breakers (either inverse−time or instantaneous trip<br />

types) may be used in lieu of above fuses wh<strong>en</strong> it is shown<br />

that the let−through <strong>en</strong>ergy (I 2 t) and peak let−through curr<strong>en</strong>t<br />

(Ip) of the inverse−time curr<strong>en</strong>t−limiting circuit breaker will be<br />

less than that of the non−semiconductor type K5 fuses with<br />

which the drive has be<strong>en</strong> tested. An inverse−time circuit<br />

breaker may be used, sized upon the input rating of the drive,<br />

multiplied by 300 %.<br />

Use 60/75 °C or 75 °C copper wire only.<br />

If mounted on a motor the <strong>en</strong>vironm<strong>en</strong>tal rating tests for<br />

Type 4 and Type 12 shall be performed.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 143


1<br />

Consignes <strong>de</strong> sécurité<br />

Dangers résiduels, prés<strong>en</strong>tation <strong>de</strong>s consignes <strong>de</strong> sécurité<br />

Prés<strong>en</strong>tation <strong>de</strong>s consignes <strong>de</strong> sécurité<br />

Toutes les consignes <strong>de</strong> sécurité sont prés<strong>en</strong>tées <strong>de</strong> façon i<strong>de</strong>ntique :<br />

Le pictogramme annonce le type <strong>de</strong> risque.<br />

Le mot associé au pictogramme indique l’int<strong>en</strong>sité du risque<br />

<strong>en</strong>couru.<br />

L’explication décrit la gravité <strong>de</strong> ce risque et les moy<strong>en</strong>s <strong>de</strong><br />

l’éviter.<br />

Pictogramme Mot associé au pictogramme Risques <strong>en</strong>courus<br />

Mot associé au<br />

Signification<br />

pictogramme<br />

<br />

T<strong>en</strong>sion électrique<br />

dangereuse<br />

<br />

Autre danger<br />

<br />

<br />

Danger !<br />

Avertissem<strong>en</strong>t !<br />

Att<strong>en</strong>tion !<br />

Danger immin<strong>en</strong>t m<strong>en</strong>açant<br />

les personnes<br />

Situation pot<strong>en</strong>tiellem<strong>en</strong>t très<br />

dangereuse m<strong>en</strong>açant les<br />

personnes<br />

Situation pot<strong>en</strong>tiellem<strong>en</strong>t<br />

dangereuse m<strong>en</strong>açant les<br />

personnes<br />

Mort ou blessures très<br />

graves<br />

Mort ou blessures très<br />

graves<br />

Blessures légères<br />

Stop ! Risques <strong>de</strong> dégâts matériels Endommagem<strong>en</strong>t <strong>de</strong><br />

l’appareil ou <strong>de</strong> son<br />

<strong>en</strong>vironnem<strong>en</strong>t<br />

Remarque<br />

importante !<br />

Conseil pratique<br />

permettant une manipulation<br />

plus facile du système<br />

d’<strong>en</strong>traînem<strong>en</strong>t<br />

144<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Spécifications techniques<br />

Normes et conditions ambiantes<br />

2<br />

Conformité CE Directive Basse T<strong>en</strong>sion (73/23/CEE)<br />

Homologations UL 508C Un<strong>de</strong>rwriter Laboratories (File−No. E132659)<br />

Power Conversion Equipm<strong>en</strong>t<br />

Résistance aux chocs Résistance à l’accélération jusqu’à 2g (Germanischer Lloyd, conditions<br />

générales)<br />

Conditions climatiques Classe 3K3 selon EN 50178 (sans con<strong>de</strong>nsation, humidité relative moy<strong>en</strong>ne<br />

85 %)<br />

Plages<br />

Transport −25 °C ... +70 °C<br />

<strong>de</strong> température autorisées<br />

Stockage −25 °C ... +60 °C<br />

Altitu<strong>de</strong> d’implantation<br />

admissible<br />

Positions <strong>de</strong> montage<br />

Espaces <strong>de</strong> montage<br />

Fonctionne−<br />

m<strong>en</strong>t<br />

−20 °C ... +60 °C<br />

> +40 °C : Réduire le courant nominal <strong>de</strong> sortie <strong>de</strong> 2,5 %/°C.<br />

0 ... 4000 m au−<strong>de</strong>ssus du niveau <strong>de</strong> la mer<br />

> 1000 m au−<strong>de</strong>ssus du niveau <strong>de</strong> la mer : Réduire le courant nominal <strong>de</strong><br />

sortie <strong>de</strong> 5 %/1000 m.<br />

Toutes les positions et les directions sont autorisées.<br />

Au−<strong>de</strong>ssus <strong>de</strong> 100 mm<br />

l’appareil<br />

Sur les côtés 100 mm<br />

<strong>de</strong> l’appareil<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 145


2<br />

Spécifications techniques<br />

Caractéristiques électriques générales<br />

Caractéristiques électriques générales<br />

CEM7.<br />

Perturbations<br />

radioélectriques : émission<br />

Respect <strong>de</strong>s exig<strong>en</strong>ces selon EN 61800−3/A11<br />

Montage sur le moteur Respect <strong>de</strong>s valeurs limites classe A et B selon<br />

EN 55011<br />

Montage au mur/sur le<br />

bâti <strong>de</strong> la machine<br />

Respect <strong>de</strong>s valeurs limites classe A selon<br />

EN 55011 (câble blindé jusqu’à 10 m)<br />

Respect <strong>de</strong>s valeurs limites classe B selon<br />

EN 55011 (câble blindé jusqu’à 1 m)<br />

Courant <strong>de</strong> fuite sur PE > 3,5 mA<br />

(selon EN 50178)<br />

Protection 8. IP 55<br />

Sans capot <strong>de</strong> protection sur l’interface AIF<br />

(NEMA 250 type 12)<br />

IP 65<br />

Avec capot <strong>de</strong> protection sur l’interface AIF<br />

(NEMA 250 type 4)<br />

Mesures <strong>de</strong> protection Contre court−circuit, mise à la terre (protection contre mise à la terre<br />

complète p<strong>en</strong>dant le fonctionnem<strong>en</strong>t, protection restreinte lors <strong>de</strong> la mise<br />

sous t<strong>en</strong>sion), surt<strong>en</strong>sion, décrochage moteur, surtempérature moteur<br />

(<strong>en</strong>trée PTC ou contact thermique à ouverture, surveillance I 2 t)<br />

Isolem<strong>en</strong>t <strong>de</strong> protection <strong>de</strong>s<br />

circuits <strong>de</strong> comman<strong>de</strong><br />

Fonctionnem<strong>en</strong>t sur réseaux<br />

publics (limitation <strong>de</strong>s<br />

harmoniques selon<br />

EN 61000−3−2)<br />

Coupure réseau<br />

Double isolation/isolation r<strong>en</strong>forcée selon EN 50178<br />

Puissance totale sur Exig<strong>en</strong>ces respectées 1)<br />

réseau<br />

0,25 <strong>kW</strong> ... 0,75 <strong>kW</strong> Avec self réseau<br />

> 1 <strong>kW</strong> Sans mesure supplém<strong>en</strong>taire<br />

1) Les mesures supplém<strong>en</strong>taires indiquées font que seul le variateur <strong>de</strong> vitesse répond aux<br />

exig<strong>en</strong>ces <strong>de</strong> la norme EN 61000−3−2. La responsabilité du respect <strong>de</strong> la norme applicable<br />

à la machine/l’installation incombe au constructeur <strong>de</strong> la machine/<strong>de</strong> l’installation !<br />

Fonctionnem<strong>en</strong>t avec puissance nominale<br />

Puissance moteur typique P N [KW] 0,55 0,75 1,5 2,2<br />

<strong>82</strong>00 <strong>motec</strong> Type E<strong>82</strong>MV551_4B E<strong>82</strong>MV751_4B E<strong>82</strong>MV152_4B E<strong>82</strong>MV222_4B<br />

T<strong>en</strong>sion d’alim<strong>en</strong>tation<br />

U N [V]<br />

3/PE CA ; 320 V − 0 % ... 550 V + 0 %<br />

(45 Hz − 0 % ... 65 Hz + 0 %)<br />

Spécifications pour<br />

fonctionnem<strong>en</strong>t sur un réseau<br />

400 V 400 V 400 V 400 V<br />

3 PE CA<br />

Courant nominal réseau I N [A] 1,8 2,4 3,8 5,5<br />

Courant <strong>de</strong> sortie 8 kHz * I N8 [A] 1,8 2,4 3,9 5,6<br />

Courant <strong>de</strong> sortie maxi<br />

p<strong>en</strong>dant 60s<br />

* Fréqu<strong>en</strong>ce <strong>de</strong> découpage<br />

8 kHz * I max8 [A] 2,7 3,6 5,8 8,4<br />

146<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Spécifications techniques<br />

Encombrem<strong>en</strong>ts, conception mécanique<br />

2<br />

Encombrem<strong>en</strong>ts<br />

c<br />

b<br />

a<br />

f<br />

d<br />

e<br />

<strong>82</strong>00mot001<br />

Type a [mm] b [mm] c [mm] d [mm] e [mm] f [mm]<br />

E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Conception mécanique<br />

156 151 135 202 15 26<br />

176 167 151 230 15 26<br />

Type Raccords vissés Poids<br />

E<strong>82</strong>MV551_4B 2 M25 (longueur filetée 10 mm, sans contre−écrou)<br />

E<strong>82</strong>MV751_4B 4 M16 (longueur filetée 10 mm, sans contre−écrou)<br />

1 M20 Pour câble moteur <strong>en</strong> cas <strong>de</strong> montage au mur/sur le bâti <strong>de</strong><br />

la machine (presse−étoupe CEM, longueur filetée 10 mm,<br />

avec contre−écrou)<br />

2,8 kg<br />

E<strong>82</strong>MV152_4B 1 M20 (longueur filetée 10 mm, sans contre−écrou)<br />

E<strong>82</strong>MV222_4B 2 M25 (longueur filetée 10 mm, sans contre−écrou)<br />

4 M16 (longueur filetée 10 mm, sans contre−écrou)<br />

4,1 kg<br />

1 M20 Pour câble moteur <strong>en</strong> cas <strong>de</strong> montage au mur/sur le bâti <strong>de</strong><br />

la machine (presse−étoupe CEM, longueur filetée 10 mm,<br />

avec contre−écrou)<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 147


3<br />

<strong>motec</strong> avec moteur ou motoréducteur<br />

Montage<br />

Danger !<br />

Après le raccor<strong>de</strong>m<strong>en</strong>t d’une son<strong>de</strong> thermique PTC ou d’un<br />

contact thermique, les bornes <strong>de</strong> comman<strong>de</strong> ne possè<strong>de</strong>nt<br />

plus qu’une isolation <strong>de</strong> base (espace interborne simple).<br />

Lorsque l’espace d’isolem<strong>en</strong>t prés<strong>en</strong>te un défaut, la<br />

protection contre les contacts acci<strong>de</strong>ntels n’est assurée qu’à<br />

l’ai<strong>de</strong> <strong>de</strong> mesures supplém<strong>en</strong>taires (exemple : double<br />

isolation).<br />

148<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


<strong>motec</strong> avec moteur ou motoréducteur<br />

Montage<br />

3<br />

1b<br />

1a<br />

1a<br />

Fig. 23<br />

X1<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

1a<br />

<strong>82</strong>00mot002<br />

162<br />

Activer la surveillance <strong>de</strong> température moteur <strong>en</strong> C0119 (exemple : C0119 = 1) !<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 149


3<br />

<strong>motec</strong> avec moteur ou motoréducteur<br />

Câblage conforme CEM<br />

Remplir les conditions suivantes pour assurer un fonctionnem<strong>en</strong>t<br />

sans problème :<br />

<br />

<br />

<br />

Tous les câbles (à l’exception du câble réseau) doiv<strong>en</strong>t être blindés<br />

impérativem<strong>en</strong>t.<br />

Relier soigneusem<strong>en</strong>t le blindage avec PE.<br />

Raccor<strong>de</strong>r les conducteurs <strong>de</strong> protection moteur et réseau à <strong>de</strong>s<br />

bornes PE différ<strong>en</strong>tes.<br />

Blindage :<br />

1. Préparer le câble.<br />

X1<br />

A<br />

B<br />

F<br />

2. Passer le câble <strong>en</strong><br />

travers <strong>de</strong> l’oeillet<br />

<strong>de</strong> la tôle <strong>de</strong><br />

blindage et replier<br />

l’oeillet.<br />

C<br />

D<br />

E<br />

<strong>82</strong>00mot101<br />

3. Visser l’oeillet avec<br />

la tôle <strong>de</strong> blindage.<br />

Le blindage doit être<br />

serré à fond avec la<br />

tôle <strong>de</strong> blindage.<br />

0.7 Nm<br />

6 lb-in<br />

<strong>82</strong>00mot<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

PES<br />

Câble réseau L1, L2, L3, PE<br />

Raccor<strong>de</strong>m<strong>en</strong>t du câble réseau avec PE (terre)<br />

Câble <strong>de</strong> comman<strong>de</strong> blindé<br />

Blindage du câble <strong>de</strong> comman<strong>de</strong> (Le blindage avec tôle <strong>de</strong> blindage doit être serré à fond.)<br />

Module <strong>de</strong> fonction<br />

Borne isolée galvaniquem<strong>en</strong>t (exemple : point neutre pour connexion étoile du moteur)<br />

Bornier raccor<strong>de</strong>m<strong>en</strong>t réseau<br />

Raccor<strong>de</strong>m<strong>en</strong>t HF via connexion avec PE par surface importante<br />

150<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Equipem<strong>en</strong>t livré<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Fig. 24<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Embase<br />

1b Module électronique<br />

2a Joint<br />

3 Entretoise/plaque <strong>de</strong> montage<br />

4a Capot <strong>de</strong> fermeture pour montage au mur/sur le bâti <strong>de</strong> la machine<br />

4b Vis pour montage au mur/sur le bâti <strong>de</strong> la machine<br />

5a Tôle <strong>de</strong> blindage<br />

5b Vis pour tôle <strong>de</strong> blindage (pour fixation du blindage sur la tôle <strong>de</strong> blindage)<br />

X1 Bornier raccor<strong>de</strong>m<strong>en</strong>t réseau, relais, résistance <strong>de</strong> <strong>fr</strong>einage<br />

X2 Bornier raccor<strong>de</strong>m<strong>en</strong>t moteur, son<strong>de</strong> thermique (PTC) ou contact thermique à ouverture<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 151


3<br />

Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Préparatifs<br />

a<br />

c<br />

b<br />

3<br />

4a<br />

2a<br />

d<br />

1 ×M20 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

2 ×M25<br />

4 ×M16<br />

Fig. 25<br />

5.3 mm<br />

3 3<br />

A<br />

1 ×M20<br />

1a<br />

1a<br />

e<br />

3<br />

2a<br />

5a<br />

<strong>82</strong>00mot004<br />

1a<br />

4b<br />

3.4Nm<br />

30 lb-in<br />

Presse−étoupe métallique pour câble moteur (exemple : presse−étoupe CEM)<br />

152<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Préparatifs<br />

Entretoise/plaque <strong>de</strong> montage Orifices <strong>de</strong> perçage Distance<br />

a [mm] b [mm] c [mm] d [mm] e [mm]<br />

85 152 61 120 26<br />

85 172 61 140 26<br />

3<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 153


3<br />

Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Raccor<strong>de</strong>m<strong>en</strong>t moteur<br />

Danger !<br />

Après le raccor<strong>de</strong>m<strong>en</strong>t d’une son<strong>de</strong> thermique PTC ou d’un<br />

contact thermique, les bornes <strong>de</strong> comman<strong>de</strong> ne possè<strong>de</strong>nt<br />

plus qu’une isolation <strong>de</strong> base (espace interborne simple).<br />

Lorsque l’espace d’isolem<strong>en</strong>t prés<strong>en</strong>te un défaut, la<br />

protection contre les contacts acci<strong>de</strong>ntels n’est assurée qu’à<br />

l’ai<strong>de</strong> <strong>de</strong> mesures supplém<strong>en</strong>taires (exemple : double<br />

isolation).<br />

X2 T1 T2 PE W V U<br />

X2<br />

T1 T2<br />

PE<br />

W V U<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

T1<br />

T2<br />

<br />

PE<br />

5.5 mm<br />

2.5 mm<br />

2<br />

AWG 12<br />

6mm<br />

X2<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

1a<br />

B<br />

A<br />

3.4 Nm<br />

30 lb-in<br />

Fig. 26<br />

3.4 Nm<br />

30 lb-in<br />

<br />

<strong>82</strong>00mot006<br />

1a<br />

Utiliser un câble moteur <strong>de</strong> faible capacité (brin/brin 75 pF/m, brin/blindage 150 pF/m).<br />

En utilisant un câble moteur aussi court que possible les caractéristiques d’<strong>en</strong>traînem<strong>en</strong>t se trouv<strong>en</strong>t<br />

améliorées !<br />

Sections <strong>de</strong> câbles U, V, W, PE:<br />

E<strong>82</strong>MV551_4B, E<strong>82</strong>MV751_4B 1 mm 2 (AWG 18), câble blindé<br />

E<strong>82</strong>MV222_4B, E<strong>82</strong>MV152_4B 1,5 mm 2 (AWG 16), câble blindé<br />

<br />

Pour la surveillance <strong>de</strong> température moteur, poser séparém<strong>en</strong>t un câble blindé et le relier avec X2/T1<br />

et X2/T2.<br />

154<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


V<br />

Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Raccor<strong>de</strong>m<strong>en</strong>t moteur<br />

Veiller à ce que les câbles <strong>de</strong> comman<strong>de</strong> et les câbles réseau ne pass<strong>en</strong>t pas dans les mêmes<br />

canalisations que les câbles puissance.<br />

3<br />

X2<br />

T1<br />

T2 PE W<br />

U<br />

PES<br />

PES<br />

PES<br />

PE<br />

<br />

M<br />

3~<br />

PES<br />

PTC<br />

M<br />

3~<br />

162<br />

<strong>82</strong>00mot168<br />

PES Raccor<strong>de</strong>m<strong>en</strong>t HF via connexion avec PE par blindage ( 156 ) ou raccord vissé moteur CEM<br />

X2/T1, Borniers <strong>de</strong> raccor<strong>de</strong>m<strong>en</strong>t pour surveillance <strong>de</strong> température moteur par son<strong>de</strong> thermique PTC ou<br />

X2/T2 contact thermique à ouverture<br />

Activer la surveillance <strong>de</strong> température moteur <strong>en</strong> C0119 (exemple : C0119 = 1) !<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 155


3<br />

Montage au mur/sur le bâti <strong>de</strong> la machine<br />

Câblage conforme CEM<br />

Remplir les conditions suivantes pour assurer un fonctionnem<strong>en</strong>t<br />

sans problème :<br />

Tous les câbles (à l’exception du câble réseau) doiv<strong>en</strong>t être blindés<br />

impérativem<strong>en</strong>t.<br />

Relier soigneusem<strong>en</strong>t le blindage avec PE.<br />

Veiller à ce que les câbles <strong>de</strong> comman<strong>de</strong> et les câbles réseau ne<br />

pass<strong>en</strong>t pas dans les mêmes canalisations que les câbles puissance.<br />

Raccor<strong>de</strong>r les conducteurs <strong>de</strong> protection moteur et réseau à <strong>de</strong>s<br />

bornes PE différ<strong>en</strong>tes.<br />

A<br />

C<br />

F<br />

D<br />

B<br />

E<br />

G<br />

X1<br />

J<br />

X2<br />

H<br />

I<br />

Blindage :<br />

1. Préparer le câble.<br />

2. Passer le câble <strong>en</strong><br />

travers <strong>de</strong> l’oeillet <strong>de</strong> la<br />

tôle <strong>de</strong> blindage et<br />

replier l’oeillet.<br />

3. Visser l’oeillet avec la<br />

tôle <strong>de</strong> blindage. Le<br />

blindage doit être serré<br />

à fond avec la tôle <strong>de</strong><br />

blindage.<br />

0.7 Nm<br />

6 lb-in<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

X1<br />

X2<br />

PES<br />

156<br />

Fig. 27<br />

<strong>82</strong>00mot100<br />

Câble réseau L1, L2, L3, PE<br />

Raccor<strong>de</strong>m<strong>en</strong>t du câble réseau avec PE (terre)<br />

Câble moteur blindé (Utiliser <strong>de</strong>s câbles moteur <strong>de</strong> faible capacité.)<br />

Presse−étoupe CEM pour câble moteur<br />

Raccor<strong>de</strong>m<strong>en</strong>t du câble moteur avec PE (terre)<br />

Câble <strong>de</strong> comman<strong>de</strong> blindé<br />

Blindage du câble <strong>de</strong> comman<strong>de</strong> (Le blindage avec tôle <strong>de</strong> blindage doit être serré à fond.)<br />

Raccor<strong>de</strong>m<strong>en</strong>t PE bornier X2<br />

Borne isolée galvaniquem<strong>en</strong>t (exemple : point neutre pour connexion étoile du moteur)<br />

Module <strong>de</strong> fonction<br />

Bornier raccor<strong>de</strong>m<strong>en</strong>t réseau<br />

Bornier raccor<strong>de</strong>m<strong>en</strong>t moteur<br />

Raccor<strong>de</strong>m<strong>en</strong>t HF via connexion avec PE par surface importante<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

PES<br />

L


Montage sur le moteur<br />

Equipem<strong>en</strong>t livré<br />

3<br />

2a 3<br />

2x<br />

1b<br />

Fig. 28<br />

1a<br />

X1<br />

X2<br />

4a<br />

4b<br />

M4×25<br />

4×<br />

5a<br />

5b<br />

M3×16<br />

4×<br />

<strong>82</strong>00mot003<br />

1a Embase<br />

1b Module électronique<br />

2a Joint<br />

3 Entretoise/plaque <strong>de</strong> montage<br />

4a Capot <strong>de</strong> fermeture pour montage au mur/sur le bâti <strong>de</strong> la machine<br />

4b Vis pour montage au mur/sur le bâti <strong>de</strong> la machine<br />

5a Tôle <strong>de</strong> blindage<br />

5b Vis pour tôle <strong>de</strong> blindage (pour fixation du blindage sur la tôle <strong>de</strong> blindage)<br />

X1 Bornier raccor<strong>de</strong>m<strong>en</strong>t réseau, relais, résistance <strong>de</strong> <strong>fr</strong>einage<br />

X2 Bornier raccor<strong>de</strong>m<strong>en</strong>t moteur, son<strong>de</strong> thermique (PTC) ou contact thermique à ouverture<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 157


3<br />

Montage sur le moteur<br />

Préparatifs<br />

<br />

68-73mm<br />

68-73mm<br />

3.4 Nm<br />

30 lb-in<br />

5mm<br />

<br />

<br />

5a<br />

1a<br />

Fig. 29<br />

2a<br />

<br />

3<br />

1a<br />

1 × M20 (E<strong>82</strong>MV152/<br />

E<strong>82</strong>MV222)<br />

2 × M25<br />

4 × M16<br />

2a<br />

1a<br />

<strong>82</strong>00mot007<br />

Préparatifs sur le moteur<br />

Retirer le joint <strong>de</strong> la boîte à bornes et le bornier moteur.<br />

Ev<strong>en</strong>tuellem<strong>en</strong>t, prolonger le câble moteur.<br />

Monter la base sur le moteur :<br />

La fixation utilisée doit assurer <strong>en</strong> perman<strong>en</strong>ce la liaison mécanique (év<strong>en</strong>tuellem<strong>en</strong>t, utiliser <strong>de</strong>s ron<strong>de</strong>lles à<br />

<strong>de</strong>nts chevauchantes) (DIN 6798).<br />

Si une distance s’impose, utiliser (2a), (3) et vis 35 mm (DIN 7985) (sans : seulem<strong>en</strong>t vis 20 mm (DIN<br />

7985))<br />

La protection IP65 n’est garantie que si le joint a été positionné soigneusem<strong>en</strong>t.<br />

158<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


5.5 mm<br />

Montage sur le moteur<br />

Raccor<strong>de</strong>m<strong>en</strong>t moteur<br />

3<br />

Danger !<br />

Après le raccor<strong>de</strong>m<strong>en</strong>t d’une son<strong>de</strong> thermique PTC ou d’un<br />

contact thermique, les bornes <strong>de</strong> comman<strong>de</strong> ne possè<strong>de</strong>nt<br />

plus qu’une isolation <strong>de</strong> base (espace interborne simple).<br />

Lorsque l’espace d’isolem<strong>en</strong>t prés<strong>en</strong>te un défaut, la<br />

protection contre les contacts acci<strong>de</strong>ntels n’est assurée qu’à<br />

l’ai<strong>de</strong> <strong>de</strong> mesures supplém<strong>en</strong>taires (exemple : double<br />

isolation).<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

W2 U2 V2<br />

2.5 mm<br />

2<br />

AWG 12<br />

X2<br />

T1<br />

T1 T2 PE W<br />

T2<br />

V<br />

U<br />

U1 V1 W1 PE<br />

6mm<br />

PE<br />

<br />

0.5...0.6 Nm<br />

4.4…5.3 lb-in<br />

X2<br />

Fig. 30<br />

3.4 Nm<br />

30 lb-in<br />

3.4 Nm<br />

30 lb-in<br />

1a<br />

T1 T2 PE W V U<br />

<strong>82</strong>00mot008<br />

1a<br />

X2/T1,<br />

X2/T2<br />

L<br />

Borniers <strong>de</strong> raccor<strong>de</strong>m<strong>en</strong>t pour surveillance <strong>de</strong> température moteur par son<strong>de</strong> thermique PTC ou<br />

contact thermique à ouverture<br />

Activer la surveillance <strong>de</strong> température moteur <strong>en</strong> C0119 (exemple : C0119 = 1) !<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 159


3<br />

Montage sur le moteur<br />

Câblage conforme CEM<br />

Remplir les conditions suivantes pour assurer un fonctionnem<strong>en</strong>t<br />

sans problème :<br />

<br />

<br />

<br />

Tous les câbles (à l’exception du câble réseau) doiv<strong>en</strong>t être blindés<br />

impérativem<strong>en</strong>t.<br />

Relier soigneusem<strong>en</strong>t le blindage avec PE.<br />

Raccor<strong>de</strong>r les conducteurs <strong>de</strong> protection moteur et réseau à <strong>de</strong>s<br />

bornes PE différ<strong>en</strong>tes.<br />

Blindage :<br />

1. Préparer le câble.<br />

A<br />

B<br />

C<br />

X1<br />

X2<br />

F<br />

G<br />

2. Passer le câble <strong>en</strong><br />

travers <strong>de</strong> l’oeillet<br />

<strong>de</strong> la tôle <strong>de</strong><br />

blindage et replier<br />

l’oeillet.<br />

D<br />

E<br />

H<br />

3. Visser l’oeillet avec<br />

la tôle <strong>de</strong> blindage.<br />

Le blindage doit être<br />

serré à fond avec la<br />

tôle <strong>de</strong> blindage.<br />

0.7 Nm<br />

6 lb-in<br />

Fig. 31<br />

<strong>82</strong>00mot101<br />

PES<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

160<br />

Câble réseau L1, L2, L3, PE<br />

Raccor<strong>de</strong>m<strong>en</strong>t du câble réseau avec PE (terre)<br />

Raccor<strong>de</strong>m<strong>en</strong>t du moteur avec PE (terre)<br />

Câble <strong>de</strong> comman<strong>de</strong> blindé<br />

Blindage du câble <strong>de</strong> comman<strong>de</strong> (Le blindage avec tôle <strong>de</strong> blindage doit être serré à fond.)<br />

Raccor<strong>de</strong>m<strong>en</strong>t PE bornier X2<br />

Borne isolée galvaniquem<strong>en</strong>t (exemple : point neutre pour connexion étoile du moteur)<br />

Module <strong>de</strong> fonction<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


X1<br />

X2<br />

PES<br />

Bornier raccor<strong>de</strong>m<strong>en</strong>t réseau<br />

Bornier raccor<strong>de</strong>m<strong>en</strong>t moteur<br />

Raccor<strong>de</strong>m<strong>en</strong>t HF via connexion avec PE par surface importante<br />

Montage sur le moteur<br />

Câblage conforme CEM<br />

3<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 161


4<br />

Installation électrique<br />

Raccor<strong>de</strong>m<strong>en</strong>t réseau/résistance <strong>de</strong> <strong>fr</strong>einage<br />

Stop!<br />

Le courant <strong>de</strong> fuite vers la terre est 3,5 mA. D’après la norme<br />

EN 50178 une installation fixe est nécessaire. Assurer<br />

impérativem<strong>en</strong>t une connexion PE selon EN 50178.<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X1<br />

5.5 mm<br />

PE<br />

L3 L2 L1 BR2 BR1 BR0 K14 K12 K11<br />

2.5 mm 2<br />

AWG 12<br />

6 mm<br />

K14 K12 K11<br />

164<br />

Fig. 32<br />

A<br />

BR2 BR1 BR0<br />

R B<br />

1a<br />

3.4 Nm<br />

30 lb-in<br />

3/PE AC 320...550V 45...65Hz<br />

L1<br />

L2<br />

L3<br />

PE<br />

F1<br />

K1<br />

<strong>82</strong>00mot009<br />

X1<br />

L3 L2<br />

L1<br />

<br />

R B = résistance <strong>de</strong> <strong>fr</strong>einage (accessoires)<br />

R B 450 (E<strong>82</strong>MV551/E<strong>82</strong>MV751)<br />

R B 200 (E<strong>82</strong>MV152/E<strong>82</strong>MV222)<br />

162<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Installation électrique<br />

Raccor<strong>de</strong>m<strong>en</strong>t réseau/résistance <strong>de</strong> <strong>fr</strong>einage<br />

Fusibles et sections <strong>de</strong> câbles<br />

4<br />

Type Réseau Installation selon EN 60204−1 Installation selon UL 1) FI 2)<br />

Fusible Disjoncteur L1, L2, L3, PE<br />

[mm 2 ]<br />

Fusible<br />

L1, L2, L3, PE<br />

[AWG]<br />

E<strong>82</strong>MV551_4B<br />

M6 A B6 A 1 5 A 18<br />

E<strong>82</strong>MV751_4B 3/PE CA M6 A B6 A 1 5 A 18<br />

320 ... 550 V ;<br />

E<strong>82</strong>MV152_4B M6 A B6 A 1 5 A 18<br />

45 ... 65 Hz<br />

E<strong>82</strong>MV222_4B M10 A B10 A 1,5 10 A 16<br />

30 mA<br />

1) N’utiliser que <strong>de</strong>s câbles, fusibles et supports fusibles homologués UL !<br />

Fusible UL : t<strong>en</strong>sion 500 − 600 V, caractéristique <strong>de</strong> décl<strong>en</strong>chem<strong>en</strong>t "H", "K5" ou "CC"<br />

2) Disjoncteur différ<strong>en</strong>tiel s<strong>en</strong>sitif courant impulsionnel ou disjoncteur différ<strong>en</strong>tiel s<strong>en</strong>sitif tout<br />

courant<br />

Respecter les réglem<strong>en</strong>tations nationales et régionales.<br />

Remarque sur l’utilisation <strong>de</strong> disjoncteurs différ<strong>en</strong>tiels :<br />

Le disjoncteur différ<strong>en</strong>tiel ne doit être installé qu’<strong>en</strong>tre le réseau<br />

d’alim<strong>en</strong>tation et le variateur.<br />

Des décl<strong>en</strong>chem<strong>en</strong>ts inopinés du disjoncteur différ<strong>en</strong>tiel peuv<strong>en</strong>t se<br />

produire <strong>en</strong> raison<br />

– <strong>de</strong>s courants <strong>de</strong> fuite capacitifs <strong>de</strong> blindages <strong>de</strong> câbles (notamm<strong>en</strong>t<br />

pour <strong>de</strong>s câbles blindés longs),<br />

– <strong>de</strong> la connexion réseau simultanée <strong>de</strong> plusieurs variateurs.<br />

<strong>82</strong>00 <strong>motec</strong> <strong>en</strong> connexion parallèle<br />

Type<br />

E<strong>82</strong>MV551_4B<br />

E<strong>82</strong>MV751_4B<br />

E<strong>82</strong>MV152_4B<br />

E<strong>82</strong>MV222_4B<br />

IMPORTANT<br />

Courant<br />

réseau<br />

1,8 A<br />

2,4 A<br />

3,8 A<br />

5,5 A<br />

Contacteur réseau nécessaire pour connexion <strong>de</strong> :<br />

1 <strong>motec</strong> 2 <strong>motec</strong> 3 <strong>motec</strong> 4 <strong>motec</strong> 5 <strong>motec</strong> 6 <strong>motec</strong><br />

4 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 15 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1) 22 <strong>kW</strong> 1)<br />

4 <strong>kW</strong> 2) 5,5 <strong>kW</strong> 2) 7,5 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2) 11 <strong>kW</strong> 2)<br />

Le total <strong>de</strong>s courants réseau ne doit pas dépasser 24 A !<br />

1) Contacteur réseau déterminé par courant <strong>de</strong> démarrage<br />

2) Contacteur réseau <strong>en</strong> fonctionnem<strong>en</strong>t avec self réseau 1,5 mH/24 A (réf. <strong>de</strong><br />

comman<strong>de</strong> ELN3−0150H024) ou module <strong>de</strong> limitation <strong>de</strong> courant E<strong>82</strong>ZJ004 (20 A<br />

maxi/phase).<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 163


4<br />

Installation électrique<br />

Raccor<strong>de</strong>m<strong>en</strong>t sortie relais<br />

<strong>82</strong>00 <strong>motec</strong><br />

X1<br />

K14 K12 K11 X1<br />

Fig. 33<br />

PES<br />

1a<br />

PES<br />

<strong>82</strong>00mot148<br />

X1/K11<br />

X1/K12<br />

X1/K14<br />

PES<br />

Fonction<br />

Sortie relais (contact à<br />

ouverture)<br />

Contact c<strong>en</strong>tral relais<br />

Sortie relais (contact à<br />

fermeture)<br />

Position relais<br />

commutée<br />

Ouvert<br />

Fermé<br />

Message<br />

(réglage L<strong>en</strong>ze)<br />

Défaut TRIP<br />

Défaut TRIP<br />

Raccor<strong>de</strong>m<strong>en</strong>t HF via connexion avec PE par surface importante<br />

Spécifications techniques<br />

250 V/3 A CA<br />

24 V/2 A CC ... 240 V/0,22 A CC<br />

Nota !<br />

Utiliser <strong>de</strong>s câbles blindés pour la transmission <strong>de</strong>s signaux<br />

<strong>de</strong> comman<strong>de</strong> et prévoir un raccor<strong>de</strong>m<strong>en</strong>t HF via connexion<br />

par PE.<br />

Pour la commutation du réseau, <strong>de</strong>s câbles non blindés sont<br />

suffisants.<br />

En cas <strong>de</strong> charge inductive ou capacitive, prévoir<br />

impérativem<strong>en</strong>t <strong>de</strong>s mesures <strong>de</strong> protection afin <strong>de</strong> protéger<br />

les contacts relais.<br />

La durée <strong>de</strong> vie du relais dép<strong>en</strong>d du type <strong>de</strong> la charge<br />

(ohmique, inductive, capacitive) et <strong>de</strong> la capacité <strong>de</strong><br />

commutation.<br />

Le message affiché peut être modifié <strong>en</strong> C0008 ou C0415/1.<br />

164<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Montage module <strong>de</strong> fonction (option) 5<br />

Stop!<br />

Blin<strong>de</strong>r impérativem<strong>en</strong>t les câbles <strong>de</strong> comman<strong>de</strong> afin d’éviter<br />

toute perturbation radioélectrique.<br />

Retirer le capot <strong>de</strong> protection FIF sur le module électronique<br />

et le capot <strong>de</strong> protection du module <strong>de</strong> fonction. Autrem<strong>en</strong>t,<br />

le <strong>motec</strong> ou le module <strong>de</strong> fonction risqu<strong>en</strong>t d’être<br />

<strong>en</strong>dommagés.<br />

1<br />

klick<br />

2<br />

<br />

1a<br />

X3<br />

3<br />

<br />

4<br />

1a<br />

0.5...0.6 Nm<br />

4.4...5.3 lb-in<br />

X3<br />

PES<br />

PES<br />

2<br />

1 mm<br />

AWG 18<br />

6mm<br />

<strong>82</strong>00mot147<br />

1b<br />

1. Encliqueter le module <strong>de</strong> fonction.<br />

2. Enlever le capot <strong>de</strong> protection du module <strong>de</strong> fonction (ne pas le<br />

jeter).<br />

3. Enlever le capot <strong>de</strong> protection FIF (ne pas les jeter).<br />

4. Câblage : Voir instructions <strong>de</strong> montage du module <strong>de</strong> fonction.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 165


6<br />

Assemblage du <strong>motec</strong><br />

<strong>motec</strong> avec module <strong>de</strong> fonction<br />

Stop!<br />

Avant l’assemblage, retirer impérativem<strong>en</strong>t le capot <strong>de</strong><br />

protection du module <strong>de</strong> fonction et retirer le capot <strong>de</strong><br />

protection FIF ! (Ne pas les jeter). Autrem<strong>en</strong>t, le <strong>motec</strong><br />

risque d’être détruit !<br />

Compléter la plaque signalétique <strong>motec</strong> à l’ai<strong>de</strong> <strong>de</strong><br />

l’autocollant joint au module <strong>de</strong> fonction.<br />

<br />

<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

Standard-I/O<br />

S<br />

<strong>82</strong>00mot059<br />

166<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Assemblage du <strong>motec</strong> 6<br />

<strong>motec</strong> sans module <strong>de</strong> fonction<br />

Stop!<br />

Le capot <strong>de</strong> protection doit être <strong>en</strong>fiché. Autrem<strong>en</strong>t, la<br />

fonctionnalité du <strong>motec</strong> n’est pas assurée !<br />

2.4 Nm<br />

21 lb-in<br />

IP65<br />

AIF<br />

<br />

<strong>82</strong>00mot138<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 167


7<br />

Mise <strong>en</strong> service<br />

Avant la première mise <strong>en</strong> service<br />

Remarque importante !<br />

Respecter l’ordre <strong>de</strong>s opérations !<br />

En cas <strong>de</strong> problèmes lors <strong>de</strong> la mise <strong>en</strong> service, consulter le<br />

chapitre "Détection et élimination <strong>de</strong>s défauts".<br />

Afin d’éviter <strong>de</strong>s dommages corporels et matériels, vérifier ...<br />

... avant la mise sous t<strong>en</strong>sion<br />

le câblage dans son intégralité pour éviter un court−circuit ou un<br />

défaut terre.<br />

la fonction d’arrêt d’urg<strong>en</strong>ce <strong>de</strong> l’installation.<br />

si le type <strong>de</strong> couplage (étoile/triangle) du moteur est adapté à la<br />

t<strong>en</strong>sion <strong>de</strong> sortie du variateur <strong>de</strong> vitesse.<br />

si aucun module <strong>de</strong> fonction n’est utilisé : le capot <strong>de</strong> protection FIF<br />

est−il <strong>en</strong>fiché (état à la livraison) ?<br />

si la source interne X3/20 (exemple : E/S standard) est utilisée : les<br />

bornes X3/7 et X3/39 sont−elles pontées ?<br />

... les principaux paramètres d’<strong>en</strong>traînem<strong>en</strong>t avant d’activer le<br />

déblocage variateur :<br />

les principaux paramètres d’<strong>en</strong>traînem<strong>en</strong>t sont−ils adaptés à votre<br />

application ?<br />

– Exemple : configuration <strong>de</strong>s <strong>en</strong>trées et sorties analogiques et<br />

numériques<br />

168<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Mise <strong>en</strong> service<br />

Sélection du mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t adapté<br />

En sélectionnant le mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t, vous pouvez déterminer le<br />

mo<strong>de</strong> <strong>de</strong> comman<strong>de</strong> ou le mo<strong>de</strong> <strong>de</strong> régulation du variateur. Plusieurs mo<strong>de</strong>s<br />

<strong>de</strong> fonctionnem<strong>en</strong>t sont possibles :<br />

fonctionnem<strong>en</strong>t <strong>en</strong> U/f,<br />

contrôle vectoriel,<br />

régulation <strong>de</strong> couple sans capteur.<br />

Choisir le mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t optimal<br />

Le fonctionnem<strong>en</strong>t <strong>en</strong> U/f est le mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t classique pour les<br />

applications standard.<br />

En comparaison avec le fonctionnem<strong>en</strong>t <strong>en</strong> U/f, le contrôle vectoriel vous<br />

permet d’obt<strong>en</strong>ir <strong>de</strong>s caractéristiques d’<strong>en</strong>traînem<strong>en</strong>t améliorées grâce<br />

à l’augm<strong>en</strong>tation du couple dans toute la plage <strong>de</strong> vitesse,<br />

à la précision <strong>de</strong> vitesse accrue et la rotation améliorée,<br />

au r<strong>en</strong><strong>de</strong>m<strong>en</strong>t plus élevé.<br />

M<br />

<br />

<br />

7<br />

M N<br />

n N<br />

n<br />

<strong>82</strong>00vec524<br />

<br />

<br />

Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong> U/f<br />

Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t contrôle vectoriel<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 169


7<br />

Mise <strong>en</strong> service<br />

Sélection du mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t adapté<br />

Mo<strong>de</strong>s <strong>de</strong> fonctionnem<strong>en</strong>t recommandés pour les applications<br />

standard<br />

Le tableau suivant vous permet <strong>de</strong> sélectionner le mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t<br />

approprié pour votre application standard.<br />

Applications<br />

Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t<br />

Réglage <strong>en</strong> C0014<br />

Entraînem<strong>en</strong>ts individuels<br />

Recommandation Au choix<br />

Avec charges variables <strong>fr</strong>équ<strong>en</strong>tes 4 2<br />

Avec démarrage dans <strong>de</strong>s conditions sévères 4 2<br />

Avec régulation <strong>de</strong> vitesse (bouclage <strong>de</strong> vitesse) 2 4<br />

Avec dynamique élevée (exemple : <strong>en</strong>traînem<strong>en</strong>ts <strong>de</strong> positionnem<strong>en</strong>t et 2 −<br />

d’approche)<br />

Avec consigne <strong>de</strong> couple 5 −<br />

Avec limitation <strong>de</strong> couple (régulation <strong>de</strong> puissance) 2 4<br />

Moteurs triphasés à reluctance 2 −<br />

Moteurs triphasés à glissem<strong>en</strong>t 2 −<br />

Moteurs triphasés avec courbe <strong>fr</strong>équ<strong>en</strong>ce/t<strong>en</strong>sion fixe 2 −<br />

Entraînem<strong>en</strong>ts <strong>de</strong> pompes et <strong>de</strong> v<strong>en</strong>tilateurs avec courbe <strong>de</strong> charge<br />

quadratique<br />

3 2 ou 4<br />

Entraînem<strong>en</strong>ts multiples<br />

(plusieurs moteurs connectés sur un seul variateur)<br />

Moteurs i<strong>de</strong>ntiques avec charges i<strong>de</strong>ntiques 2 −<br />

Moteurs différ<strong>en</strong>ts et/ou charges variables 2 −<br />

C0014 = 2 : mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe linéaire<br />

C0014 = 3 : mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe quadratique<br />

C0014 = 4 : mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t contrôle vectoriel<br />

C0014 = 5 : régulation <strong>de</strong> couple sans capteur<br />

170<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Mise <strong>en</strong> service<br />

Paramétrage à l’ai<strong>de</strong> du clavier <strong>de</strong> comman<strong>de</strong> E<strong>82</strong>ZBB<br />

7<br />

Description<br />

Disponible <strong>en</strong> option, le clavier <strong>de</strong> comman<strong>de</strong> E<strong>82</strong>ZBC est installé dans un<br />

support <strong>en</strong> caoutchouc. Le raccor<strong>de</strong>m<strong>en</strong>t au variateur s’effectue à l’ai<strong>de</strong> du<br />

câble <strong>de</strong> liaison séparé type E<strong>82</strong>ZWL. Pour la <strong>de</strong>scription complète du<br />

clavier, se reporter aux instructions <strong>de</strong> mise <strong>en</strong> service du clavier (comprises<br />

dans l’emballage).<br />

Raccor<strong>de</strong>m<strong>en</strong>t du clavier<br />

Le clavier peut égalem<strong>en</strong>t être <strong>en</strong>fiché ou retiré à l’emplacem<strong>en</strong>t AIF du<br />

variateur p<strong>en</strong>dant le fonctionnem<strong>en</strong>t du variateur.<br />

Lorsque le clavier est mis sous t<strong>en</strong>sion, un auto−test est effectué. Le clavier<br />

est prêt à fonctionner lorsque le mo<strong>de</strong> Service (niveau fonctionnem<strong>en</strong>t) est<br />

affiché.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 171


7<br />

Mise <strong>en</strong> service<br />

Fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe linéaire<br />

La <strong>de</strong>scription ci−<strong>de</strong>ssous est valable pour les variateurs <strong>de</strong> vitesse dotés<br />

d’un module <strong>de</strong> fonction E/S standard et d’un moteur triphasé asynchrone<br />

<strong>de</strong> puissance correspondante.<br />

1. Raccor<strong>de</strong>r le clavier <strong>de</strong><br />

comman<strong>de</strong>.<br />

2. S’assurer que le blocage<br />

variateur est activé après la mise<br />

sous t<strong>en</strong>sion.<br />

3. Mettre sous t<strong>en</strong>sion.<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Borne X3/28 = BAS<br />

4. Au bout <strong>de</strong> 2 s <strong>en</strong>v., le clavier <strong>de</strong><br />

comman<strong>de</strong> se trouve <strong>en</strong> mo<strong>de</strong><br />

d’affichage Disp" et indique la<br />

<br />

PS 1<br />

<br />

<strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie (C0050).<br />

000 000<br />

<br />

Hi<br />

Hz<br />

Lo<br />

0050<br />

misc002<br />

Le m<strong>en</strong>u USEr est<br />

activé.<br />

5. Passer au mo<strong>de</strong> pour<br />

<br />

<br />

<br />

<br />

pouvoir procé<strong>de</strong>r aux réglages <strong>de</strong><br />

<br />

base <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t. 000 000<br />

PS<br />

1 La m<strong>en</strong>tion 0050<br />

<br />

0050 clignote.<br />

Hi<br />

Hz<br />

Lo<br />

6. Adapter la plage <strong>de</strong><br />

t<strong>en</strong>sion/courant pour le réglage<br />

<strong>de</strong> la consigne analogique<br />

(C0034).<br />

Réglage L<strong>en</strong>ze : −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

Positionner correctem<strong>en</strong>t<br />

les interrupteurs DIP sur<br />

le module E/S standard<br />

(voir les instructions <strong>de</strong><br />

montage du module E/S<br />

standard).<br />

7. Adapter la configuration <strong>de</strong>s<br />

bornes au câblage (C0007).<br />

Réglage L<strong>en</strong>ze : −0−, c’est−à−dire<br />

E1 : JOG1/3 sélection <strong>de</strong><br />

consignes fixes<br />

E2 : JOG2/3<br />

E3 : <strong>fr</strong>einage courant continu<br />

<strong>fr</strong>ein CC<br />

E4 : s<strong>en</strong>s horaire/antihoraire<br />

CW/CCW<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

8. Régler la <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie<br />

minimale (C0010).<br />

Réglage L<strong>en</strong>ze : 0,00 Hz<br />

[f]<br />

C0011<br />

9. Régler la <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie<br />

maximale (C0011).<br />

Réglage L<strong>en</strong>ze : 50,00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

172<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


10. Régler le temps d’accélération T ir<br />

(C0012).<br />

Réglage L<strong>en</strong>ze : 5,00 s<br />

11. Régler le temps <strong>de</strong> décélération<br />

T if (C0013).<br />

Réglage L<strong>en</strong>ze : 5,00 s<br />

12. Régler la <strong>fr</strong>équ<strong>en</strong>ce nominale U/f<br />

(C0015).<br />

Réglage L<strong>en</strong>ze : 50,00 Hz<br />

13. Régler l’accroissem<strong>en</strong>t U min<br />

(C0016).<br />

Réglage L<strong>en</strong>ze : selon le type <strong>de</strong><br />

variateur.<br />

14. Pour procé<strong>de</strong>r à d’autres<br />

réglages, passer au m<strong>en</strong>u ALL.<br />

Mise <strong>en</strong> service<br />

Fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe linéaire<br />

B0 <br />

+ <br />

B<br />

B <br />

<br />

U out<br />

100%<br />

U min<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

0<br />

0 C0015<br />

Par exemple, activer les <strong>fr</strong>équ<strong>en</strong>ces<br />

fixes (JOG) (C0037, C0038, C0039)<br />

ou la surveillance <strong>de</strong> la température<br />

du moteur (C0119).<br />

15. Passer au m<strong>en</strong>u ALL.<br />

A Vérifier le réglage pour la<br />

surveillance du v<strong>en</strong>tilateur <strong>en</strong><br />

C0608 :<br />

– pour les convertisseurs<br />

<strong>82</strong>00 <strong>motec</strong> 0,25...0,37 <strong>kW</strong><br />

et 0,55...2,2 <strong>kW</strong> :<br />

C0608 = 0 ! (réglage usine)<br />

– pour les convertisseurs<br />

<strong>82</strong>00 <strong>motec</strong> 3...7,5 <strong>kW</strong> :<br />

C0608 =1 ou C0608 = 2 !<br />

Stop ! Activer<br />

impérativem<strong>en</strong>t la<br />

fonction lors <strong>de</strong> la mise<br />

<strong>en</strong> service ! A défaut, le<br />

variateur <strong>de</strong> vitesse<br />

risque <strong>de</strong> surchauffer et<br />

d’être détruit.<br />

– tous les autres variateurs<br />

<strong>de</strong> vitesse :<br />

C0608 = 0 ! (réglage usine)<br />

B Régler év<strong>en</strong>tuellem<strong>en</strong>t<br />

d’autres fonctions via <strong>de</strong>s<br />

co<strong>de</strong>s.<br />

Une fois tous les réglages effectués :<br />

16. Entrer la consigne. Par exemple, via un pot<strong>en</strong>tiomètre<br />

sur les bornes 7, 8, 9<br />

f<br />

7<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = temps d’accélération<br />

souhaité<br />

T if<br />

Н Н t if<br />

C0011<br />

f 2<br />

f 1<br />

t if = temps <strong>de</strong> décélération<br />

souhaité<br />

Le réglage L<strong>en</strong>ze<br />

convi<strong>en</strong>t pour toutes les<br />

applications courantes.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 173


7<br />

Mise <strong>en</strong> service<br />

Fonctionnem<strong>en</strong>t <strong>en</strong> U/f avec courbe linéaire<br />

17. Débloquer le variateur.<br />

X3<br />

20 28<br />

misc002<br />

Borne X3/28 = HAUT<br />

18. L’<strong>en</strong>traînem<strong>en</strong>t tourne. Si l’<strong>en</strong>traînem<strong>en</strong>t ne<br />

démarre pas, appuyer <strong>en</strong><br />

plus sur .<br />

174<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Mise <strong>en</strong> service<br />

Contrôle vectoriel<br />

La <strong>de</strong>scription ci−<strong>de</strong>ssous est valable pour les variateurs <strong>de</strong> vitesse dotés<br />

d’un module <strong>de</strong> fonction E/S standard et d’un moteur triphasé asynchrone<br />

<strong>de</strong> puissance correspondante.<br />

7<br />

1. Raccor<strong>de</strong>r le clavier <strong>de</strong><br />

comman<strong>de</strong>.<br />

2. S’assurer que le blocage<br />

variateur est activé après la mise<br />

sous t<strong>en</strong>sion.<br />

3. Mettre sous t<strong>en</strong>sion.<br />

<br />

ON<br />

X3<br />

20 28<br />

misc001<br />

Borne X3/28 = BAS<br />

4. Au bout <strong>de</strong> 2 s <strong>en</strong>v., le clavier <strong>de</strong><br />

comman<strong>de</strong> se trouve <strong>en</strong> mo<strong>de</strong><br />

d’affichage Disp" et indique la<br />

<br />

PS 1<br />

<br />

<strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie (C0050).<br />

000 000<br />

<br />

Hi<br />

Hz<br />

Lo<br />

0050<br />

misc002<br />

Le m<strong>en</strong>u USEr est<br />

activé.<br />

5. Passer au m<strong>en</strong>u ALL.<br />

6. Passer au mo<strong>de</strong> pour<br />

<br />

<br />

<br />

<br />

<br />

pouvoir procé<strong>de</strong>r aux réglages <strong>de</strong><br />

<br />

base <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t.<br />

000 000<br />

PS 1 La m<strong>en</strong>tion 0050<br />

<br />

0050 clignote.<br />

Hi<br />

Hz<br />

Lo<br />

7. Adapter la configuration <strong>de</strong>s<br />

bornes au câblage (C0007).<br />

Réglage L<strong>en</strong>ze : −0−, c’est−à−dire<br />

E1 : JOG1/3 sélection <strong>de</strong><br />

consignes fixes<br />

E2 : JOG2/3<br />

E3 : <strong>fr</strong>einage courant continu<br />

<strong>fr</strong>ein CC<br />

E4 : s<strong>en</strong>s horaire/antihoraire<br />

CW/CCW<br />

<br />

<br />

<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0007<br />

0 000<br />

8. Régler la <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie<br />

minimale (C0010).<br />

Réglage L<strong>en</strong>ze : 0,00 Hz<br />

[f]<br />

C0011<br />

9. Régler la <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie<br />

maximale (C0011).<br />

Réglage L<strong>en</strong>ze : 50,00 Hz<br />

C0010<br />

0 %<br />

100 %<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 175


7<br />

Mise <strong>en</strong> service<br />

Contrôle vectoriel<br />

10. Régler le temps d’accélération T ir<br />

(C0012).<br />

Réglage L<strong>en</strong>ze : 5,00 s<br />

11. Régler le temps <strong>de</strong> décélération<br />

T if (C0013).<br />

Réglage L<strong>en</strong>ze : 5,00 s<br />

12. Régler le mo<strong>de</strong> <strong>de</strong><br />

fonctionnem<strong>en</strong>t "contrôle<br />

vectoriel" (C0014 = 4).<br />

Réglage L<strong>en</strong>ze : fonctionnem<strong>en</strong>t<br />

<strong>en</strong> U/f linéaire (C0014 = 2)<br />

13. Adapter la plage <strong>de</strong><br />

t<strong>en</strong>sion/courant pour le réglage<br />

<strong>de</strong> la consigne analogique<br />

(C0034).<br />

Réglage L<strong>en</strong>ze : −0−,<br />

(0 ... 5 V/0 ... 10 V/0 ... 20 mA)<br />

B0 <br />

+ <br />

B<br />

B <br />

<br />

<br />

<br />

<br />

J EH<br />

JEB<br />

J<br />

6 EH 6 EB<br />

<br />

SHPRG M<strong>en</strong>u<br />

Co<strong>de</strong><br />

001400<br />

Para<br />

Vector-Ctrl<br />

4<br />

9371BC008<br />

<br />

PS 1<br />

<br />

<br />

<br />

Hi<br />

Lo<br />

0034<br />

0 000<br />

T ir<br />

Н Н t ir<br />

C0011<br />

f 2<br />

f 1<br />

t ir = temps d’accélération<br />

souhaité<br />

T if<br />

Н Н t if<br />

C0011<br />

f 2<br />

f 1<br />

t if = temps <strong>de</strong> décélération<br />

souhaité<br />

Positionner correctem<strong>en</strong>t<br />

les interrupteurs DIP sur<br />

le module E/S standard<br />

(voir les instructions <strong>de</strong><br />

montage du module E/S<br />

standard).<br />

14. Entrer les données du moteur. Voir la plaque<br />

signalétique du moteur.<br />

A Vitesse nominale du moteur<br />

(C0087)<br />

Réglage L<strong>en</strong>ze : 1390 min−1<br />

B<br />

C<br />

D<br />

E<br />

Courant nominal du moteur<br />

(C0088)<br />

Réglage L<strong>en</strong>ze : <strong>en</strong> fonction <strong>de</strong><br />

l’appareil<br />

Fréqu<strong>en</strong>ce nominale du moteur<br />

(C0089)<br />

Réglage L<strong>en</strong>ze : 50 Hz<br />

T<strong>en</strong>sion nominale du moteur<br />

(C0090)<br />

Réglage L<strong>en</strong>ze : <strong>en</strong> fonction <strong>de</strong><br />

l’appareil<br />

Cos du moteur (C0091)<br />

Réglage L<strong>en</strong>ze : <strong>en</strong> fonction <strong>de</strong><br />

l’appareil<br />

Entrer la valeur pour le<br />

type <strong>de</strong> couplage moteur<br />

(étoile/triangle) choisi !<br />

Entrer la valeur pour le<br />

type <strong>de</strong> couplage moteur<br />

(étoile/triangle) choisi !<br />

176<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


15. Lancer l’i<strong>de</strong>ntification <strong>de</strong>s<br />

paramètres moteur (C0148).<br />

A<br />

S’assurer que le variateur est<br />

bloqué.<br />

<br />

B Régler C0148 = 1. Appuyer sur .<br />

C<br />

D<br />

Débloquer le variateur.<br />

Si au bout <strong>de</strong> 30 s <strong>en</strong>v., le<br />

segm<strong>en</strong>t est <strong>de</strong> nouveau<br />

activé, rebloquer le variateur.<br />

Mise <strong>en</strong> service<br />

X3<br />

20 28<br />

Contrôle vectoriel<br />

misc001<br />

7<br />

Ne procé<strong>de</strong>r à<br />

l’i<strong>de</strong>ntification que<br />

lorsque le moteur est<br />

<strong>fr</strong>oid !<br />

Borne X3/28 = BAS<br />

X3 Borne X3/28 = HAUT<br />

20 28 misc002 L’i<strong>de</strong>ntification<br />

démarre :<br />

– Le segm<strong>en</strong>t <br />

s’éteint.<br />

– Le moteur est<br />

alim<strong>en</strong>té et "siffle"<br />

doucem<strong>en</strong>t.<br />

– Le moteur ne<br />

tourne pas !<br />

X3<br />

Borne X3/28 = BAS<br />

20 28<br />

misc001 L’i<strong>de</strong>ntification est<br />

terminée.<br />

Les données<br />

suivantes ont été<br />

calculées et<br />

sauvegardées :<br />

– <strong>fr</strong>équ<strong>en</strong>ce nominale<br />

U/f (C0015)<br />

– comp<strong>en</strong>sation <strong>de</strong><br />

glissem<strong>en</strong>t (C0021)<br />

– inductance<br />

statorique du<br />

moteur (C0092)<br />

Les données<br />

suivantes ont été<br />

mesurées et<br />

sauvegardées :<br />

– résistance<br />

statorique du<br />

moteur (C0084) =<br />

résistance totale du<br />

câble moteur et du<br />

moteur<br />

<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 177


7<br />

Mise <strong>en</strong> service<br />

Contrôle vectoriel<br />

16. Régler év<strong>en</strong>tuellem<strong>en</strong>t d’autres<br />

paramètres.<br />

Par exemple, activer les <strong>fr</strong>équ<strong>en</strong>ces<br />

fixes (JOG) (C0037, C0038, C0039)<br />

ou la surveillance <strong>de</strong> la température<br />

du moteur (C0119).<br />

17. Passer au m<strong>en</strong>u ALL.<br />

A Vérifier le réglage pour la<br />

surveillance du v<strong>en</strong>tilateur <strong>en</strong><br />

C0608 :<br />

– pour les convertisseurs<br />

<strong>82</strong>00 <strong>motec</strong> 0,25...0,37 <strong>kW</strong><br />

et 0,55...2,2 <strong>kW</strong> :<br />

C0608 = 0 ! (réglage usine)<br />

– pour les convertisseurs<br />

<strong>82</strong>00 <strong>motec</strong> 3...7,5 <strong>kW</strong> :<br />

C0608 =1 ou C0608 = 2 !<br />

Stop ! Activer<br />

impérativem<strong>en</strong>t la<br />

fonction lors <strong>de</strong> la mise<br />

<strong>en</strong> service ! A défaut, le<br />

variateur <strong>de</strong> vitesse<br />

risque <strong>de</strong> surchauffer et<br />

d’être détruit.<br />

– tous les autres variateurs<br />

<strong>de</strong> vitesse :<br />

C0608 = 0 ! (réglage usine)<br />

B Régler év<strong>en</strong>tuellem<strong>en</strong>t<br />

d’autres fonctions via <strong>de</strong>s<br />

co<strong>de</strong>s.<br />

Une fois tous les réglages effectués :<br />

18. Entrer la consigne. Par exemple, via un pot<strong>en</strong>tiomètre<br />

sur les bornes 7, 8, 9<br />

19. Débloquer le variateur.<br />

X3<br />

Borne X3/28 = HAUT<br />

20 28 misc002<br />

20. L’<strong>en</strong>traînem<strong>en</strong>t tourne. Si l’<strong>en</strong>traînem<strong>en</strong>t ne<br />

démarre pas, appuyer <strong>en</strong><br />

plus sur .<br />

178<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Mise <strong>en</strong> service<br />

Contrôle vectoriel<br />

Optimisation du contrôle vectoriel<br />

Après l’i<strong>de</strong>ntification <strong>de</strong>s paramètres moteur, le contrôle vectoriel peut être<br />

appliqué, <strong>en</strong> général, sans mesure supplém<strong>en</strong>taire. L’optimisation du<br />

contrôle vectoriel s’impose uniquem<strong>en</strong>t pour les cas suivants : −15−<br />

Comportem<strong>en</strong>t <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t<br />

Le moteur force et courant moteur (C0054) > 60 % du<br />

courant nominal moteur <strong>en</strong> marche à vi<strong>de</strong><br />

(fonctionnem<strong>en</strong>t stationnaire)<br />

Couple trop faible avec <strong>de</strong>s <strong>fr</strong>équ<strong>en</strong>ces f < 5 Hz<br />

(couple <strong>de</strong> démarrage)<br />

Constance <strong>de</strong> vitesse insuffisante avec charge accrue<br />

(la consigne et la vitesse moteur ne sont plus<br />

proportionnelles)<br />

Affichages défauts OC1, OC3, OC4 ou OC5 pour les<br />

temps d’accélération (C0012) < 1 s (le variateur ne<br />

peut plus suivre les processus dynamiques)<br />

Remè<strong>de</strong><br />

7<br />

1. Réduire l’inductance moteur (C0092) <strong>de</strong> 10 %.<br />

2. Vérifier le courant moteur <strong>en</strong> C0054.<br />

3. Avec un courant moteur (C0054) > 50 % du<br />

courant nominal moteur<br />

– réduire C0092 jusqu’à ce qu’<strong>en</strong>v. 50 % du<br />

courant nominal moteur soi<strong>en</strong>t atteints.<br />

– Réduire C0092 <strong>de</strong> 20 % au maximum !<br />

– Remarque : la réduction <strong>de</strong> C0092 <strong>en</strong>traîne une<br />

réduction du couple !<br />

Augm<strong>en</strong>ter la résistance moteur (C0084) ou<br />

augm<strong>en</strong>ter l’inductance moteur (C0092).<br />

Augm<strong>en</strong>ter la comp<strong>en</strong>sation <strong>de</strong> glissem<strong>en</strong>t (C0021).<br />

Toute surcomp<strong>en</strong>sation provoque une instabilité <strong>de</strong><br />

l’<strong>en</strong>traînem<strong>en</strong>t !<br />

Modifier le temps d’intégration du régulateur I max<br />

(C0078).<br />

Réduire C0078 = Le régulateur I max <strong>de</strong>vi<strong>en</strong>t plus<br />

rapi<strong>de</strong> (plus dynamique).<br />

Augm<strong>en</strong>ter C0078 = Le régulateur I max <strong>de</strong>vi<strong>en</strong>t plus<br />

l<strong>en</strong>t ("plus doux").<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 179


7<br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Nota !<br />

Le tableau ci−après décrit <strong>en</strong> détail les co<strong>de</strong>s utilisés dans les<br />

exemples <strong>de</strong> mise <strong>en</strong> service !<br />

Ne pas modifier les co<strong>de</strong>s dont vous ne connaissez pas la<br />

signification ! Tous les co<strong>de</strong>s sont décrits <strong>en</strong> détail dans le<br />

manuel système.<br />

Lecture d’un tableau <strong>de</strong>s co<strong>de</strong>s<br />

Colonne Abréviation Signification<br />

Co<strong>de</strong> Cxxxx Co<strong>de</strong> Cxxxx Le co<strong>de</strong> peut avoir <strong>de</strong>s valeurs différ<strong>en</strong>tes<br />

1 Sous−co<strong>de</strong> 1 <strong>de</strong> pour chaque jeu <strong>de</strong> paramètres.<br />

Cxxxx<br />

Le nouveau paramètre est immédiatem<strong>en</strong>t<br />

2 Sous−co<strong>de</strong> 2 <strong>de</strong><br />

Cxxxx<br />

pris <strong>en</strong> compte (<strong>en</strong> ligne).<br />

* Le paramètre est i<strong>de</strong>ntique pour tous les jeux <strong>de</strong> paramètres.<br />

<br />

<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong> type<br />

E<strong>82</strong>ZBC<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong> type XT<br />

EMZ9371BC<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong> type<br />

E<strong>82</strong>ZBC<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong> type XT<br />

EMZ9371BC<br />

Prise <strong>en</strong> compte du paramètre modifié du<br />

co<strong>de</strong> ou du sous−co<strong>de</strong> <strong>en</strong> appuyant sur <br />

Prise <strong>en</strong> compte du paramètre modifié du<br />

co<strong>de</strong> ou du sous−co<strong>de</strong> <strong>en</strong> appuyant sur <br />

<br />

Prise <strong>en</strong> compte du paramètre modifié du<br />

co<strong>de</strong> ou du sous−co<strong>de</strong> <strong>en</strong> appuyant sur à<br />

condition que le variateur soit bloqué<br />

Prise <strong>en</strong> compte du paramètre modifié du<br />

co<strong>de</strong> ou du sous−co<strong>de</strong> <strong>en</strong> appuyant sur <br />

à condition que le variateur soit bloqué<br />

(A)<br />

Co<strong>de</strong>, sous−co<strong>de</strong> ou sélection possible uniquem<strong>en</strong>t <strong>en</strong><br />

fonctionnem<strong>en</strong>t avec un module <strong>de</strong> fonction E/S application<br />

uSEr<br />

M<strong>en</strong>u utilisateur, avec les réglages L<strong>en</strong>ze<br />

Désignation<br />

Désignation du co<strong>de</strong><br />

L<strong>en</strong>ze<br />

Réglage L<strong>en</strong>ze (réglage usine à la livraison ou après retour au<br />

réglage usine par C0002)<br />

<br />

La colonne "IMPORTANT" conti<strong>en</strong>t <strong>de</strong>s informations supplém<strong>en</strong>taires.<br />

Choix 1 {%} 99 Valeur mini {unité} Valeur maxi<br />

IMPORTANT − Explications supplém<strong>en</strong>taires, importantes et courtes<br />

180<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Co<strong>de</strong> Réglages possibles IMPORTANT<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0002 Gestion <strong>de</strong>s 0 0 Prêt PAR1 ... PAR4 :<br />

*<br />

<br />

jeux <strong>de</strong><br />

paramètres<br />

jeux <strong>de</strong> paramètres du<br />

variateur<br />

uSEr −16−<br />

PAR1 ... PAR4 compr<strong>en</strong>n<strong>en</strong>t<br />

égalem<strong>en</strong>t les paramètres<br />

pour les modules <strong>de</strong><br />

fonction E/S standard, E/S<br />

application, interface AS−i,<br />

bus système (CAN).<br />

FPAR1 :<br />

jeu <strong>de</strong> paramètres<br />

spécifique aux modules <strong>de</strong><br />

fonction bus INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

FPAR1 est sauvegardé dans<br />

le module <strong>de</strong> fonction.<br />

Retour au<br />

1 Réglage L<strong>en</strong>ze PAR1 Retour au réglage usine du jeu<br />

réglage usine<br />

<strong>de</strong> paramètres sélectionné<br />

2<br />

(état à la<br />

Réglage L<strong>en</strong>ze PAR2<br />

livraison)<br />

3 Réglage L<strong>en</strong>ze PAR3<br />

4 Réglage L<strong>en</strong>ze PAR4<br />

31 Réglage L<strong>en</strong>ze FPAR1 Retour au réglage usine du<br />

module <strong>de</strong> fonction bus <strong>de</strong><br />

terrain<br />

61 Réglage L<strong>en</strong>ze PAR1 + FPAR1 Retour au réglage usine du jeu<br />

62 Réglage L<strong>en</strong>ze PAR2 + FPAR1<br />

<strong>de</strong> paramètres sélectionné et<br />

du module <strong>de</strong> fonction bus <strong>de</strong><br />

63 Réglage L<strong>en</strong>ze PAR3 + FPAR1 terrain<br />

64 Réglage L<strong>en</strong>ze PAR4 + FPAR1<br />

C0002<br />

*<br />

<br />

uSEr<br />

(suite)<br />

Transfert <strong>de</strong><br />

jeux <strong>de</strong><br />

paramètres<br />

via clavier<br />

Clavier <strong>de</strong> comman<strong>de</strong> variateur<br />

70 Avec les modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

10 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

7<br />

Le transfert <strong>de</strong>s jeux <strong>de</strong><br />

paramètres vers d’autres<br />

variateurs est réalisé via<br />

clavier.<br />

P<strong>en</strong>dant le transfert, l’accès<br />

aux paramètres via d’autres<br />

canaux est bloqué !<br />

Tous les jeux <strong>de</strong> paramètres<br />

(PAR1 ... PAR4, le cas échéant,<br />

FPAR1) sont remplacés par les<br />

données correspondantes du<br />

clavier.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 181


7<br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Co<strong>de</strong><br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0002<br />

*<br />

<br />

uSEr<br />

(suite)<br />

Transfert <strong>de</strong><br />

jeux <strong>de</strong><br />

paramètres<br />

via clavier<br />

Clavier <strong>de</strong> comman<strong>de</strong> PAR1 (+<br />

FPAR1)<br />

71 Avec les modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

11 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

Clavier <strong>de</strong> comman<strong>de</strong> PAR2 (+<br />

FPAR1)<br />

72 Avec les modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

12 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

Clavier <strong>de</strong> comman<strong>de</strong> PAR3 (+<br />

FPAR1)<br />

73 Avec modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

13 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

Clavier <strong>de</strong> comman<strong>de</strong> PAR4 (+<br />

FPAR1)<br />

74 Avec modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

14 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

Variateur clavier <strong>de</strong> comman<strong>de</strong><br />

80 Avec les modules <strong>de</strong> fonction E/S<br />

application, INTERBUS,<br />

PROFIBUS−DP, LECOM−B,<br />

DeviceNet/CANop<strong>en</strong><br />

20 Avec tous les autres modules <strong>de</strong><br />

fonction<br />

Clavier <strong>de</strong> comman<strong>de</strong> module<br />

<strong>de</strong> fonction<br />

40 Uniquem<strong>en</strong>t avec les modules <strong>de</strong><br />

fonction INTERBUS, PROFIBUS−DP,<br />

LECOM−B, DeviceNet/CANop<strong>en</strong><br />

IMPORTANT<br />

Substituer le jeu <strong>de</strong> paramètres<br />

sélectionné et le cas échéant<br />

FPAR1 par les données<br />

correspondantes du clavier.<br />

Tous les jeux <strong>de</strong> paramètres<br />

(PAR1 ... PAR4, le cas échéant<br />

FPAR1) sont copiés dans le<br />

clavier.<br />

Seul le jeu <strong>de</strong> paramètres<br />

spécifique au module FPAR1<br />

est remplacé par les données<br />

correspondantes du clavier.<br />

1<strong>82</strong><br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0002<br />

*<br />

<br />

uSEr<br />

(suite)<br />

C0002<br />

*<br />

<br />

uSEr<br />

(suite)<br />

C0003<br />

*<br />

<br />

Sauvegar<strong>de</strong>r<br />

le réglage<br />

utilisateur<br />

Charger/copie<br />

r le réglage<br />

utilisateur<br />

Sauvegar<strong>de</strong>r<br />

les<br />

paramètres<br />

<strong>en</strong> mémoire<br />

non volatile<br />

Module <strong>de</strong> fonction clavier <strong>de</strong><br />

comman<strong>de</strong><br />

50 Uniquem<strong>en</strong>t avec les modules <strong>de</strong><br />

fonction INTERBUS, PROFIBUS−DP,<br />

LECOM−B, DeviceNet/CANop<strong>en</strong><br />

IMPORTANT<br />

7<br />

Seul le jeu <strong>de</strong> paramètres<br />

spécifique au module FPAR1<br />

est copié dans le clavier.<br />

9 PAR1 réglage utilisateur Il est possible <strong>de</strong> sauvegar<strong>de</strong>r<br />

le réglage utilisateur <strong>de</strong>s<br />

paramètres du variateur<br />

(exemple : état à la livraison <strong>de</strong><br />

votre machine).<br />

1. S’assurer que le jeu <strong>de</strong><br />

paramètres 1 soit activé.<br />

2. Bloquer le variateur.<br />

3. Régler C0003 = 3, puis<br />

vali<strong>de</strong>r par .<br />

4. Régler C0002 = 9, puis<br />

vali<strong>de</strong>r par . Le réglage<br />

utilisateur est sauvegardé.<br />

5. Régler C0003 = 1, puis<br />

vali<strong>de</strong>r par .<br />

6. Débloquer le variateur.<br />

Cette fonction vous permet <strong>de</strong><br />

copier PAR1 dans les jeux <strong>de</strong><br />

paramètres PAR2 ... PAR4.<br />

5 Réglage utilisateur PAR1 Retour au réglage utilisateur du<br />

6 Réglage utilisateur PAR2<br />

jeu <strong>de</strong> paramètres sélectionné<br />

7 Réglage utilisateur PAR3<br />

8 Réglage utilisateur PAR4<br />

1 0 Ne pas sauvegar<strong>de</strong>r le paramètre<br />

dans l’EEPROM<br />

1 Toujours sauvegar<strong>de</strong>r le paramètre<br />

dans l’EEPROM<br />

3 Sauvegar<strong>de</strong>r le réglage utilisateur<br />

dans l’EEPROM<br />

Pertes <strong>de</strong> données à la coupure<br />

réseau<br />

Actif à chaque mise sous<br />

t<strong>en</strong>sion<br />

Modification cyclique <strong>de</strong><br />

paramètres via module bus<br />

<strong>de</strong> terrain non admise<br />

Ensuite, sauvegar<strong>de</strong>r le jeu <strong>de</strong><br />

paramètres 1 comme votre<br />

propre réglage <strong>de</strong> base par<br />

C0002 = 9.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 183


7<br />

Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0007<br />

<br />

uSEr<br />

C0007<br />

<br />

uSEr<br />

(suite)<br />

Configuration<br />

fixe <strong>de</strong>s<br />

<strong>en</strong>trées<br />

numériques<br />

IMPORTANT<br />

La modification <strong>de</strong> C0007<br />

sera copiée dans le<br />

sous−co<strong>de</strong> correspondant <strong>de</strong><br />

C0410. Configuration réglée<br />

<strong>en</strong> C0410 décl<strong>en</strong>che C0007 =<br />

255 !<br />

0 E4 E3 E2 E1 H/AH = s<strong>en</strong>s<br />

0 H/AH FreinCC JOG2/3 JOG1/3 horaire/antihoraire<br />

FreinCC = <strong>fr</strong>einage courant<br />

1 H/AH PAR JOG2/3 JOG1/3<br />

continu<br />

2 H/AH AR JOG2/3 JOG1/3<br />

AR = arrêt rapi<strong>de</strong><br />

3 H/AH PAR FreinCC JOG1/3<br />

4 H/AH AR PAR JOG1/3<br />

5 H/AH FreinCC TRIP−Se<br />

t<br />

JOG1/3<br />

6 H/AH PAR TRIP−Se JOG1/3<br />

t<br />

7 H/AH PAR FreinCC TRIP−Se<br />

t<br />

8 H/AH AR PAR TRIP−Se<br />

t<br />

9 H/AH AR TRIP−Se JOG1/3<br />

t<br />

10 H/AH TRIP−Se<br />

t<br />

+vite −vite<br />

PAR = commutation jeu <strong>de</strong><br />

paramètres (PAR1 <br />

PAR2)<br />

– PAR1 = BAS, PAR2 =<br />

HAUT<br />

– La borne doit être<br />

affectée <strong>de</strong> la fonction<br />

"PAR" dans les <strong>de</strong>ux jeux<br />

<strong>de</strong> paramètres PAR1 et<br />

PAR2.<br />

– N’utiliser les<br />

configurations avec "PAR"<br />

qu’avec C0988 = 0.<br />

TRIP−Set = défaut externe<br />

E4 E3 E2 E1 Sélection<br />

11 H/AH FreinCC +vite −vite <strong>fr</strong>équ<strong>en</strong>ces<br />

fixes<br />

12 H/AH PAR +vite −vite<br />

JOG1/3 JOG2/3<br />

13 H/AH AR +vite −vite BAS BAS<br />

14 AH/AR H/AR FreinCC JOG1/3 HAUT BAS<br />

15 AH/AR H/AR PAR JOG1/3 BAS HAUT<br />

16 AH/AR H/AR JOG2/3 JOG1/3<br />

HAUT HAUT<br />

17 AH/AR H/AR PAR FreinCC<br />

18 AH/AR H/AR PAR TRIP−Se<br />

t<br />

19 AH/AR H/AR FreinCC TRIP−Se<br />

t<br />

Actif<br />

C0046<br />

JOG1<br />

JOG2<br />

JOG3<br />

184<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0007<br />

<br />

uSEr<br />

(suite)<br />

C0007<br />

<br />

uSEr<br />

(suite)<br />

IMPORTANT<br />

7<br />

E4 E3 E2 E1 +vite/−vite = fonctions<br />

20 AH/AR H/AR TRIP−Se JOG1/3 pot<strong>en</strong>tiomètre motorisé<br />

t<br />

m/autom = commutation<br />

21 AH/AR H/AR +vite −vite mo<strong>de</strong> manuel/automatique<br />

(à distance)<br />

22 AH/AR H/AR +vite JOG1/3<br />

PCTRL1−I−OFF =<br />

23 m/auto H/AH +vite −vite<br />

suppression <strong>de</strong> la<br />

24 m/auto PAR +vite −vite composante intégrale<br />

25 m/auto FreinCC +vite −vite régulateur PID<br />

DFIN1−ON = <strong>en</strong>trée<br />

26 m/auto JOG1/3 +vite −vite<br />

<strong>fr</strong>équ<strong>en</strong>ce numérique 0 ...<br />

27 m/auto TRIP−Se +vite −vite 10 kHz<br />

t<br />

PCTRL1−OFF = désactiver le<br />

régulateur PID<br />

28 JOG2/3 JOG1/3 PCTRL1<br />

−I−OFF<br />

29 JOG2/3 FreinCC PCTRL1<br />

−I−OFF<br />

30 JOG2/3 AR PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

E4 E3 E2 E1<br />

31 FreinCC AR PCTRL1<br />

−I−OFF<br />

32 TRIP−Se<br />

t<br />

AR<br />

PCTRL1<br />

−I−OFF<br />

33 AR PAR PCTRL1<br />

−I−OFF<br />

34 H/AR AH/AR PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

35 JOG2/3 JOG1/3 PAR DFIN1−O<br />

N<br />

36 FreinCC AR PAR DFIN1−O<br />

N<br />

37 JOG1/3 AR PAR DFIN1−O<br />

N<br />

38 JOG1/3 PAR TRIP−Se<br />

t<br />

39 JOG2/3 JOG1/3 TRIP−Se<br />

t<br />

40 JOG1/3 AR TRIP−Se<br />

t<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 185


7<br />

Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0007<br />

<br />

uSEr<br />

(suite)<br />

C0010<br />

uSEr<br />

C0011<br />

uSEr<br />

C0012<br />

uSEr<br />

Fréqu<strong>en</strong>ce <strong>de</strong><br />

sortie mini<br />

Fréqu<strong>en</strong>ce <strong>de</strong><br />

sortie maxi<br />

Temps<br />

d’accélération<br />

pour<br />

consigne<br />

principale<br />

E4 E3 E2 E1<br />

41 JOG1/3 FreinCC TRIP−Se<br />

t<br />

42 AR FreinCC TRIP−Se<br />

t<br />

43 H/AH AR TRIP−Se<br />

t<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

44 +vite −vite PAR DFIN1−O<br />

N<br />

45 H/AH AR PAR DFIN1−O<br />

N<br />

46 m/auto PAR AR JOG1/3<br />

47 H/AR AH/AR m/auto JOG1/3<br />

48 PCTRL1<br />

− OFF<br />

49 PCTRL1<br />

− OFF<br />

50 PCTRL1<br />

− OFF<br />

FreinCC<br />

PCTRL1<br />

−I−OFF<br />

DFIN1−O<br />

N<br />

JOG1/3 AR DFIN1−O<br />

N<br />

JOG1/3<br />

PCTRL1<br />

−I−OFF<br />

51 FreinCC PAR PCTRL1<br />

−I−OFF<br />

255 Configuration a été réglée <strong>en</strong><br />

C0410<br />

0.00 0.00<br />

14.5 Hz<br />

50.00 7.50<br />

87 Hz<br />

{0.02<br />

Hz}<br />

{0.02<br />

Hz}<br />

5.00 0.00 {0.02<br />

s}<br />

DFIN1−O<br />

N<br />

DFIN1−O<br />

N<br />

IMPORTANT<br />

Seulem<strong>en</strong>t <strong>en</strong> affichage<br />

Ne pas modifier C0007 sous<br />

risque <strong>de</strong> perdre les réglages<br />

<strong>en</strong> C0410.<br />

650.00 C0010 n’est pas actif avec<br />

consigne d’<strong>en</strong>trée bipolaire<br />

(−10 V ... + 10 V).<br />

C0010 agit uniquem<strong>en</strong>t sur<br />

l’<strong>en</strong>trée analogique 1.<br />

650.00<br />

Plage <strong>de</strong> réglage <strong>de</strong><br />

vitesse 1 : 6 pour<br />

motoréducteurs L<strong>en</strong>ze<br />

Réglage impératif pour<br />

fonctionnem<strong>en</strong>t avec<br />

motoréducteurs L<strong>en</strong>ze<br />

1300.00 Concerne : modification <strong>de</strong> la<br />

<strong>fr</strong>équ<strong>en</strong>ce 0 Hz ... C0011<br />

Consigne supplém<strong>en</strong>taire<br />

C0220<br />

Rampes d’accélération<br />

pouvant être activées via<br />

signaux numériques <br />

C0101<br />

186<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0013<br />

uSEr<br />

C0014<br />

<br />

C0015<br />

uSEr<br />

C0016<br />

uSEr<br />

Temps <strong>de</strong><br />

décélération<br />

pour<br />

consigne<br />

principale<br />

Mo<strong>de</strong> <strong>de</strong><br />

fonctionne−<br />

m<strong>en</strong>t<br />

Fréqu<strong>en</strong>ce<br />

nominale U/f<br />

5.00 0.00 {0.02<br />

s}<br />

2 2 Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong> U/f U ~<br />

f<br />

(courbe linéaire avec accroissem<strong>en</strong>t<br />

constant U min )<br />

3 Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong> U/f U ~<br />

f 2<br />

(courbe quadratique avec<br />

accroissem<strong>en</strong>t<br />

constant U min )<br />

4 Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t contrôle<br />

vectoriel<br />

5 Régulation <strong>de</strong> couple sans capteur<br />

avec limitation <strong>de</strong> vitesse<br />

Consigne <strong>de</strong> couple via C0412/6<br />

50.00 7.50 {0.02<br />

Hz}<br />

Accroissem<strong>en</strong> 0.00 {0.01<br />

t U min %}<br />

<br />

Limitation <strong>de</strong> vitesse via<br />

consigne 1 (NSET1−N1), si<br />

C0412/1 utilisé, autrem<strong>en</strong>t via<br />

<strong>fr</strong>équ<strong>en</strong>ce maxi (C0011)<br />

IMPORTANT<br />

7<br />

1300.00 Concerne : modification <strong>de</strong> la<br />

<strong>fr</strong>équ<strong>en</strong>ce C0011 ... 0 Hz<br />

Consigne supplém<strong>en</strong>taire<br />

C0221<br />

Rampes <strong>de</strong> décélération<br />

pouvant être activées via<br />

signaux numériques <br />

C0103<br />

<br />

<br />

Mise <strong>en</strong> service possible<br />

sans i<strong>de</strong>ntification <strong>de</strong>s<br />

paramètres moteur<br />

Avantages <strong>de</strong> l’i<strong>de</strong>ntification<br />

<strong>en</strong> C0148 :<br />

– stabilité améliorée pour<br />

les faibles vitesses,<br />

– la <strong>fr</strong>équ<strong>en</strong>ce nominale U/f<br />

(C0015) et le glissem<strong>en</strong>t<br />

(C0021) sont calculés et<br />

sauvegardés, et ne<br />

doiv<strong>en</strong>t pas être réglés.<br />

Lorsque ce mo<strong>de</strong> <strong>de</strong><br />

fonctionnem<strong>en</strong>t est<br />

sélectionné pour la première<br />

fois, <strong>en</strong>trer les données<br />

moteur et i<strong>de</strong>ntifier les<br />

paramètres moteur par<br />

C0148.<br />

Autrem<strong>en</strong>t, la mise <strong>en</strong><br />

service est impossible !<br />

960.00 Lors <strong>de</strong> l’i<strong>de</strong>ntification <strong>de</strong>s<br />

paramètres moteur par<br />

C0148, le paramètre C0015<br />

est calculé et sauvegardé.<br />

Le réglage s’applique pour<br />

toutes les t<strong>en</strong>sions<br />

d’alim<strong>en</strong>tation admises.<br />

40.00 En fonction <strong>de</strong> l’appareil<br />

Le réglage s’applique pour<br />

toutes les t<strong>en</strong>sions<br />

d’alim<strong>en</strong>tation admises.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 187


7<br />

Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0034<br />

*<br />

<br />

uSEr<br />

C0034<br />

*<br />

<br />

(A)<br />

uSEr<br />

Plage<br />

consigne<br />

analogique<br />

E/S standard<br />

(X3/8)<br />

−17−<br />

Plage<br />

consigne<br />

analogique<br />

E/S<br />

application<br />

IMPORTANT<br />

T<strong>en</strong>ir compte <strong>de</strong> la position <strong>de</strong>s<br />

interrupteurs DIP du module <strong>de</strong><br />

fonction !<br />

0 0 T<strong>en</strong>sion unipolaire 0 ... 5 V / 0 ... 10<br />

V<br />

Courant 0 ... 20 mA<br />

1 Courant 4 ... 20 mA Inversion du s<strong>en</strong>s <strong>de</strong> rotation<br />

uniquem<strong>en</strong>t possible avec<br />

<strong>en</strong>trée numérique<br />

2 T<strong>en</strong>sion bipolaire −10 V ... +10 V La <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie mini<br />

(C0010) est inactive.<br />

Régler l’offset et le gain.<br />

3 Courant 4 ... 20 mA avec protection<br />

contre rupture <strong>de</strong> fil<br />

TRIP Sd5, avec I < 4 mA<br />

Inversion du s<strong>en</strong>s <strong>de</strong> rotation<br />

uniquem<strong>en</strong>t possible avec<br />

<strong>en</strong>trée numérique<br />

T<strong>en</strong>ir compte <strong>de</strong> la position <strong>de</strong>s<br />

cavaliers du module <strong>de</strong><br />

fonction !<br />

1 X3/1U, X3/1I 0 0 T<strong>en</strong>sion unipolaire 0 ... 5 V / 0 ... 10<br />

V<br />

2 X3/2U, X3/2I 1 T<strong>en</strong>sion bipolaire −10 V ... +10 V La <strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie mini<br />

(C0010) est inactive.<br />

2 Courant 0 ... 20 mA<br />

3 Courant 4 ... 20 mA Inversion du s<strong>en</strong>s <strong>de</strong> rotation<br />

uniquem<strong>en</strong>t possible avec<br />

<strong>en</strong>trée numérique<br />

4 Courant 4 ... 20 mA avec protection<br />

contre rupture <strong>de</strong> fil<br />

C0037 JOG1 20.00 −650.00 {0.02<br />

Hz}<br />

C0038 JOG2 30.00 −650.00 {0.02<br />

Hz}<br />

C0039 JOG3 40.00 −650.00 {0.02<br />

Hz}<br />

C0050<br />

*<br />

uSEr<br />

Fréqu<strong>en</strong>ce <strong>de</strong><br />

sortie<br />

(MCTRL1−NO<br />

UT)<br />

Inversion du s<strong>en</strong>s <strong>de</strong> rotation<br />

uniquem<strong>en</strong>t possible avec<br />

<strong>en</strong>trée numérique<br />

TRIP Sd5 avec I < 4 mA<br />

650.00 JOG = <strong>fr</strong>équ<strong>en</strong>ce fixe<br />

Consignes fixes<br />

650.00 supplém<strong>en</strong>taires C0440<br />

650.00<br />

−650.00 {Hz} 650.00 Affichage uniquem<strong>en</strong>t :<br />

<strong>fr</strong>équ<strong>en</strong>ce <strong>de</strong> sortie sans<br />

comp<strong>en</strong>sation <strong>de</strong> glissem<strong>en</strong>t<br />

188<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0087<br />

C0088<br />

C0089<br />

C0090<br />

Vitesse<br />

nominale<br />

moteur<br />

Courant<br />

nominal<br />

moteur<br />

Fréqu<strong>en</strong>ce<br />

nominale<br />

moteur<br />

T<strong>en</strong>sion<br />

nominale<br />

moteur<br />

300 {1 rpm}<br />

(min −1 )<br />

IMPORTANT<br />

16000 En fonction <strong>de</strong> l’appareil<br />

7<br />

0.0 {0.1 A} 650.0 En fonction <strong>de</strong> l’appareil<br />

0,0 ... 2,0 x courant nominal <strong>de</strong><br />

sortie du variateur<br />

50 10 {1 Hz} 960<br />

50 {1 V} 500 230 V pour variateurs 230 V<br />

400 V pour variateurs 400 V<br />

C0091 Cos ϕ moteur 0.40 {0.1} 1.0 En fonction <strong>de</strong> l’appareil<br />

C0119<br />

<br />

−18−<br />

C0140<br />

*<br />

Configuration<br />

<strong>de</strong> la<br />

surveillance<br />

<strong>de</strong><br />

température<br />

du moteur<br />

(<strong>en</strong>trée<br />

PTC)/détectio<br />

n <strong>de</strong> mise à<br />

la terre<br />

Consigne <strong>de</strong><br />

<strong>fr</strong>équ<strong>en</strong>ce<br />

additive<br />

(NSET1−NADD<br />

)<br />

0 0 Entrée PTC<br />

désactivée<br />

1 Entrée PTC<br />

activée,<br />

mise <strong>en</strong> défaut<br />

TRIP<br />

2 Entrée PTC<br />

activée,<br />

avertissem<strong>en</strong>t<br />

activé<br />

3 Entrée PTC<br />

désactivée<br />

4 Entrée PTC<br />

activée,<br />

mise <strong>en</strong> défaut<br />

TRIP<br />

5 Entrée PTC<br />

activée,<br />

avertissem<strong>en</strong>t<br />

activé<br />

0.00 −650.00 {0.02<br />

Hz}<br />

Détection <strong>de</strong><br />

mise à la terre<br />

activée<br />

Détection <strong>de</strong><br />

mise à la terre<br />

désactivée<br />

Configuration/sélection <strong>de</strong>s<br />

signaux <strong>en</strong> C0415<br />

En utilisant plusieurs jeux<br />

<strong>de</strong> paramètres, la<br />

surveillance pour chaque<br />

jeu <strong>de</strong> paramètres doit être<br />

réglé séparém<strong>en</strong>t.<br />

Désactiver la fonction<br />

"détection <strong>de</strong> mise à la<br />

terre" si une détection <strong>de</strong><br />

mise à la terre inopinée a<br />

été provoquée.<br />

La fonction "détection <strong>de</strong><br />

mise à la terre" activée, le<br />

démarrage moteur est<br />

retardé d’<strong>en</strong>v. 40 ms après<br />

déblocage variateur.<br />

650.00 Entrée via fonction du<br />

clavier ou canal <strong>de</strong> données<br />

paramètres<br />

La valeur s’ajoute à la<br />

consigne principale.<br />

La valeur est sauvegardée<br />

<strong>en</strong> mémoire non volatile.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 189


7<br />

Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0148<br />

*<br />

<br />

C0517<br />

*<br />

<br />

I<strong>de</strong>ntification<br />

paramètres<br />

moteur<br />

M<strong>en</strong>u<br />

utilisateur<br />

IMPORTANT<br />

0 0 Prêt Ne procé<strong>de</strong>r à l’i<strong>de</strong>ntification<br />

que sur un moteur <strong>fr</strong>oid !<br />

1. Bloquer le variateur,<br />

att<strong>en</strong>dre que l’<strong>en</strong>traînem<strong>en</strong>t<br />

s’arrête.<br />

1 Démarrer l’i<strong>de</strong>ntification<br />

La <strong>fr</strong>équ<strong>en</strong>ce nominale U/f<br />

(C0015), la comp<strong>en</strong>sation <strong>de</strong><br />

glissem<strong>en</strong>t (C0021) et<br />

l’inductance statorique moteur<br />

(C0092) sont calculées et<br />

sauvegardées.<br />

La résistance statorique moteur<br />

(C0084) = résistance totale du<br />

câble moteur et du moteur est<br />

mesurée et sauvegardée.<br />

1 Mémoire 1 50 C0050 Fréqu<strong>en</strong>ce <strong>de</strong> sortie<br />

(MCTRL1−NOUT)<br />

2 Mémoire 2 34 C0034 Plage consigne analogique<br />

3 Mémoire 3 7 C0007 Configuration fixe <strong>de</strong>s signaux<br />

d’<strong>en</strong>trée numériques<br />

4 Mémoire 4 10 C0010 Fréqu<strong>en</strong>ce <strong>de</strong> sortie mini<br />

5 Mémoire 5 11 C0011 Fréqu<strong>en</strong>ce <strong>de</strong> sortie maxi<br />

6 Mémoire 6 12 C0012 Temps d’accélération pour consigne<br />

principale<br />

7 Mémoire 7 13 C0013 Temps <strong>de</strong> décélération pour<br />

consigne principale<br />

8 Mémoire 8 15 C0015 Fréqu<strong>en</strong>ce nominale U/f<br />

9 Mémoire 9 16 C0016 Accroissem<strong>en</strong>t U min<br />

10 Mémoire 10 2 C0002 Transfert <strong>de</strong> jeux <strong>de</strong> paramètres<br />

2. En C0087, C0088, C0089,<br />

C0090, C0091, régler les<br />

valeurs exactes <strong>de</strong> la plaque<br />

signalétique moteur.<br />

3. Régler C0148 = 1, vali<strong>de</strong>r<br />

avec .<br />

4. Débloquer le variateur :<br />

l’i<strong>de</strong>ntification<br />

– démarre, est éteint.<br />

– le moteur "siffle<br />

doucem<strong>en</strong>t", mais ne<br />

tourne pas !<br />

– dure <strong>en</strong>v. 30 s,<br />

– est achevée dès que <br />

est allumé.<br />

5. Bloquer le variateur.<br />

Après la mise sous t<strong>en</strong>sion<br />

ou avec la fonction <br />

activée, le co<strong>de</strong> C0517/1<br />

est affiché.<br />

Le m<strong>en</strong>u utilisateur<br />

compr<strong>en</strong>d les principaux<br />

co<strong>de</strong>s (<strong>en</strong> réglage L<strong>en</strong>ze)<br />

pour la mise <strong>en</strong> service du<br />

mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t <strong>en</strong><br />

U/f − courbe linéaire.<br />

Avec la protection par mot<br />

<strong>de</strong> passe activée, seuls les<br />

co<strong>de</strong>s programmés <strong>en</strong><br />

C0517 sont libres d’accès.<br />

Entrer les numéros <strong>de</strong>s<br />

co<strong>de</strong>s souhaités dans les<br />

sous−co<strong>de</strong>s.<br />

Il n’est pas possible d’<strong>en</strong>trer<br />

<strong>en</strong> mémoire <strong>de</strong>s co<strong>de</strong>s qui<br />

sont disponibles uniquem<strong>en</strong>t<br />

avec un module <strong>de</strong> fonction<br />

E/S application !<br />

190<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Co<strong>de</strong><br />

Mise <strong>en</strong> service<br />

Co<strong>de</strong>s principaux pour la mise <strong>en</strong> service<br />

Réglages possibles<br />

N° Désignation L<strong>en</strong>ze Choix<br />

C0608<br />

*<br />

Surveillance<br />

du v<strong>en</strong>tilateur<br />

IMPORTANT<br />

7<br />

0 0<br />

1<br />

Désactivée<br />

Message <strong>de</strong> défaut TRIP<br />

<strong>82</strong>00 <strong>motec</strong> 3 ... 7,5 <strong>kW</strong> :<br />

activer impérativem<strong>en</strong>t la<br />

fonction lors <strong>de</strong> la mise <strong>en</strong><br />

service ! A défaut, le variateur<br />

<strong>de</strong> vitesse risque <strong>de</strong><br />

2 Avertissem<strong>en</strong>t<br />

surchauffer et d’être détruit.<br />

Tous les autres variateurs <strong>de</strong><br />

vitesse :<br />

régler impérativem<strong>en</strong>t<br />

C0608 = 0.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 191


8<br />

Détection et élimination <strong>de</strong>s défauts<br />

Anomalie <strong>de</strong> fonctionnem<strong>en</strong>t <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t<br />

Anomalie <strong>de</strong> fonctionnem<strong>en</strong>t Cause Solution<br />

Le moteur ne tourne pas. T<strong>en</strong>sion du circuit intermédiaire trop<br />

faible<br />

(la LED rouge clignote (cycle <strong>de</strong> 0,4 s),<br />

affichage clavier : LU).<br />

Vérifier la t<strong>en</strong>sion réseau.<br />

Variateur bloqué.<br />

(LED verte clignote, affichage clavier :<br />

)<br />

Démarrage automatique bloqué (C0142<br />

= 0 ou 2).<br />

Freinage CC (<strong>fr</strong>ein CC) activé<br />

Frein mécanique du moteur non<br />

<strong>de</strong>sserré<br />

Arrêt rapi<strong>de</strong> (AR) activé (affichage<br />

clavier : )<br />

Consigne = 0<br />

Consigne JOG activée et <strong>fr</strong>équ<strong>en</strong>ce JOG<br />

= 0<br />

Erreur signalée<br />

Jeu <strong>de</strong> paramètres incorrect signalé<br />

Mo<strong>de</strong> <strong>de</strong> fonctionnem<strong>en</strong>t C0014 = −4−,<br />

−5− réglé, mais i<strong>de</strong>ntification <strong>de</strong>s<br />

paramètres moteur non effectuée<br />

Affectation <strong>de</strong> plusieurs fonctions<br />

s’excluant l’une l’autre d’une source <strong>de</strong><br />

signaux <strong>en</strong> C0410<br />

Source <strong>de</strong> t<strong>en</strong>sion interne X3/20 utilisée<br />

pour les modules <strong>de</strong> fonction E/S<br />

standard, INTERBUS, PROFIBUS−DP ou<br />

LECOM−B (RS485) :<br />

pont <strong>en</strong>tre X3/7 et X3/39 interrompu.<br />

Le moteur tourne irrégulièrem<strong>en</strong>t. Câble moteur défectueux<br />

Courant maxi réglé trop faible (C0022,<br />

C0023)<br />

Moteur surexcité ou sous−excité<br />

C0084, C0087, C0088, C0089, C0090,<br />

C0091 et/ou C0092 ne sont pas<br />

adaptés aux données moteur.<br />

Annuler le blocage variateur ;<br />

le blocage peut être activé par<br />

plusieurs sources.<br />

Impulsion BAS−HAUT sur X3/28<br />

:<br />

corriger év<strong>en</strong>tuellem<strong>en</strong>t la<br />

condition <strong>de</strong> démarrage<br />

(C0142).<br />

Désactiver le <strong>fr</strong>einage CC.<br />

Desserrer manuellem<strong>en</strong>t ou<br />

électriquem<strong>en</strong>t le <strong>fr</strong>ein<br />

mécanique du moteur.<br />

Annuler l’arrêt rapi<strong>de</strong>.<br />

Entrer la consigne.<br />

Entrer la consigne JOG<br />

(C0037 ... C0039).<br />

Corriger l’erreur.<br />

Commuter le jeu <strong>de</strong> paramètres<br />

correct via bornier.<br />

I<strong>de</strong>ntifier les paramètres<br />

moteur (C0148).<br />

Corriger la configuration <strong>en</strong><br />

C0410.<br />

Ponter les bornes.<br />

Vérifier le câble moteur.<br />

Adapter les réglages à<br />

l’application.<br />

Vérifier le réglage (C0015,<br />

C0016, C0014).<br />

Procé<strong>de</strong>r à une adaptation<br />

manuelle ou à une<br />

i<strong>de</strong>ntification <strong>de</strong>s paramètres<br />

moteur (C0148).<br />

192<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Détection et élimination <strong>de</strong>s défauts<br />

Anomalie <strong>de</strong> fonctionnem<strong>en</strong>t <strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t<br />

Anomalie <strong>de</strong> fonctionnem<strong>en</strong>t Cause<br />

Le courant absorbé par le moteur Réglage <strong>de</strong> C0016 trop important<br />

est trop important.<br />

Réglage <strong>de</strong> C0015 trop faible<br />

C0084, C0087, C0088, C0089, C0090,<br />

C0091 et/ou C0092 ne sont pas<br />

adaptés aux données moteur.<br />

Le moteur tourne, les consignes<br />

sont à 0".<br />

L’i<strong>de</strong>ntification <strong>de</strong>s paramètres<br />

moteur a été interrompue,<br />

l’erreur LP1 est signalée.<br />

Les caractéristiques<br />

d’<strong>en</strong>traînem<strong>en</strong>t avec contrôle<br />

vectoriel ne sont pas<br />

satisfaisantes.<br />

Réduction du couple dans la<br />

zone <strong>en</strong> puissance constante<br />

Décrochage du moteur <strong>en</strong> cas <strong>de</strong><br />

fonctionnem<strong>en</strong>t dans la zone <strong>en</strong><br />

puissance constante<br />

Une consigne a été <strong>en</strong>trée à l’ai<strong>de</strong> <strong>de</strong> la<br />

fonction du clavier.<br />

Le moteur est trop petit par rapport à la<br />

puissance nominale appareil.<br />

Le <strong>fr</strong>einage CC est activé via bornier.<br />

Divers<br />

Divers<br />

8<br />

Solution<br />

Rectifier le réglage.<br />

Rectifier le réglage.<br />

Procé<strong>de</strong>r à une adaptation<br />

manuelle ou à une<br />

i<strong>de</strong>ntification <strong>de</strong>s paramètres<br />

moteur (C0148).<br />

Mettre la consigne à "0" par<br />

C0140 = 0.<br />

Optimiser le contrôle vectoriel<br />

( 179)<br />

Contacter votre c<strong>en</strong>tre S.A.V.<br />

L<strong>en</strong>ze.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 193


PS<br />

<br />

<br />

<br />

m<br />

Hi<br />

Hz V A<br />

Lo<br />

%sh<br />

rpm Ω°C<br />

8<br />

Détection et élimination <strong>de</strong>s défauts<br />

Messages <strong>de</strong> défaut<br />

LEDs sur le variateur (affichage d’état)<br />

LED −19−<br />

rouge <br />

verte <br />

Etat <strong>de</strong> fonctionnem<strong>en</strong>t<br />

ETEINTE ALLUMEE Variateur débloqué<br />

ALLUMEE ALLUMEE Mise sous t<strong>en</strong>sion et blocage<br />

démarrage automatique<br />

ETEINTE CLIGNOTE<br />

l<strong>en</strong>tem<strong>en</strong>t<br />

Variateur bloqué<br />

ETEINTE<br />

CLIGNOTE<br />

rapi<strong>de</strong>m<strong>en</strong>t<br />

CLIGNOTE<br />

l<strong>en</strong>tem<strong>en</strong>t<br />

CLIGNOTE<br />

rapi<strong>de</strong>m<strong>en</strong>t<br />

ETEINTE<br />

ETEINTE<br />

I<strong>de</strong>ntification paramètres moteur<br />

achevée<br />

Mise hors t<strong>en</strong>sion (sous−t<strong>en</strong>sion)<br />

Défaut actif, contrôle <strong>en</strong> C0161<br />

<br />

<br />

1<br />

8888888 8<br />

88888<br />

<br />

<br />

<br />

<br />

<br />

<br />

2<br />

<br />

<br />

<br />

01 61 000 1<br />

880Hr<br />

<br />

<br />

<br />

PS<br />

Hi<br />

Lo<br />

<br />

m<br />

Hz V A<br />

%sh<br />

rpm Ω°C<br />

3<br />

X3<br />

20 28<br />

5<br />

OFF<br />

4 6 ON<br />

<strong>82</strong>mot355<br />

Pour réinitialiser le variateur <strong>en</strong> cas <strong>de</strong> panne (réarmem<strong>en</strong>t défaut), procé<strong>de</strong>r<br />

comme suit :<br />

1. <strong>en</strong>ficher le clavier <strong>de</strong> comman<strong>de</strong> sur l’interface AIF p<strong>en</strong>dant le<br />

fonctionnem<strong>en</strong>t.<br />

2. Lire et noter le message <strong>de</strong> défaut qui s’affiche.<br />

3. Bloquer le variateur <strong>de</strong> vitesse.<br />

4. Découpler le variateur du réseau.<br />

5. Procé<strong>de</strong>r à une analyse d’erreur et corriger les erreurs détectées.<br />

6. Remettre le variateur <strong>de</strong> vitesse <strong>en</strong> marche.<br />

194<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Détection et élimination <strong>de</strong>s défauts<br />

Messages <strong>de</strong> défaut<br />

Messages <strong>de</strong> défauts sur le clavier ou dans le programme <strong>de</strong><br />

paramétrage Global Drive Control<br />

8<br />

Clavier <strong>de</strong> PC 1) Défaut Origine Remè<strong>de</strong><br />

comman<strong>de</strong><br />

noer 0 Sans défaut − −<br />

ccr<br />

<br />

ce0<br />

<br />

ce1<br />

<br />

ce2<br />

<br />

ce3<br />

<br />

ce4<br />

<br />

71 Erreur système Interfér<strong>en</strong>ces importantes sur<br />

les câbles <strong>de</strong> comman<strong>de</strong><br />

Boucles <strong>de</strong> masse ou <strong>de</strong> terre<br />

dans le câblage<br />

61 Erreur <strong>de</strong><br />

communication<br />

(AIF)<br />

(configurable <strong>en</strong><br />

C0126)<br />

62 Erreur <strong>de</strong><br />

communication<br />

sur CAN−IN1<br />

(comman<strong>de</strong> Sync)<br />

63 Erreur <strong>de</strong><br />

communication<br />

sur CAN−IN2<br />

64 Erreur <strong>de</strong><br />

communication<br />

sur CAN−IN1<br />

(comman<strong>de</strong><br />

événem<strong>en</strong>tielle/c<br />

omman<strong>de</strong><br />

temporelle)<br />

65 BUS−OFF<br />

(nombreuses<br />

erreurs <strong>de</strong><br />

communication)<br />

Transmission perturbée sur<br />

AIF<br />

L’objet CAN_IN_1 reçoit <strong>de</strong>s<br />

données erronées ou la<br />

communication est<br />

interrompue.<br />

L’objet CAN_IN_2 reçoit <strong>de</strong>s<br />

données erronées ou la<br />

communication est<br />

interrompue.<br />

L’objet CAN_IN_1 reçoit <strong>de</strong>s<br />

données erronées ou la<br />

communication est<br />

interrompue.<br />

Le nombre <strong>de</strong> télégrammes<br />

défectueux reçu par le<br />

variateur via le Bus Système<br />

est trop élevé ; le variateur<br />

s’est déconnecté du bus.<br />

Blin<strong>de</strong>r les câbles <strong>de</strong> comman<strong>de</strong>.<br />

Enfoncer le module <strong>de</strong><br />

communication dans le boîtier<br />

déporté.<br />

Vérifier le connecteur<br />

<strong>en</strong>fichable module bus FIF.<br />

Vérifier l’émetteur.<br />

Ev<strong>en</strong>tuellem<strong>en</strong>t, augm<strong>en</strong>ter le<br />

temps <strong>de</strong> surveillance <strong>en</strong><br />

C0357/1.<br />

Vérifier le connecteur<br />

<strong>en</strong>fichable module bus FIF.<br />

Vérifier l’émetteur.<br />

Ev<strong>en</strong>tuellem<strong>en</strong>t, augm<strong>en</strong>ter le<br />

temps <strong>de</strong> surveillance <strong>en</strong><br />

C0357/2.<br />

Vérifier le connecteur<br />

<strong>en</strong>fichable module bus FIF.<br />

Vérifier l’émetteur.<br />

Ev<strong>en</strong>tuellem<strong>en</strong>t, augm<strong>en</strong>ter le<br />

temps <strong>de</strong> surveillance <strong>en</strong><br />

C0357/3.<br />

Vérifier la terminaison du bus.<br />

Vérifier le blindage <strong>de</strong>s câbles.<br />

Vérifier le câblage PE.<br />

Vérifier le coeffici<strong>en</strong>t<br />

d’utilisation bus ;<br />

év<strong>en</strong>tuellem<strong>en</strong>t, réduire le<br />

taux <strong>de</strong> transmission.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 195


8<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong><br />

ce5<br />

<br />

ce6<br />

<br />

ce7<br />

<br />

EEr<br />

<br />

ErP0<br />

...<br />

ErP19<br />

<br />

Détection et élimination <strong>de</strong>s défauts<br />

Messages <strong>de</strong> défaut<br />

PC 1)<br />

Défaut<br />

66 CAN Time−Out<br />

(configurable <strong>en</strong><br />

C0126)<br />

67 Le module <strong>de</strong><br />

fonction Bus<br />

Système CAN sur<br />

FIF est à l’état<br />

"Avertissem<strong>en</strong>t"<br />

ou "BUS−OFF"<br />

(configurable <strong>en</strong><br />

C0126).<br />

68 Erreur <strong>de</strong><br />

communication<br />

lors du<br />

paramétrage à<br />

distance via Bus<br />

Système (C0370)<br />

(configurable <strong>en</strong><br />

C0126)<br />

91 Défaut externe<br />

(TRIP−SET)<br />

−<br />

Interruption <strong>de</strong><br />

communication<br />

<strong>en</strong>tre le clavier et<br />

l’appareil <strong>de</strong> base<br />

Origine<br />

Paramétrage à distance via<br />

Bus Système (C0370) :<br />

l’esclave ne répond pas.<br />

Temps <strong>de</strong> surveillance<br />

communication dépassé<br />

En fonctionnem<strong>en</strong>t avec E/S<br />

application :<br />

paramétrage incorrect du<br />

changem<strong>en</strong>t <strong>de</strong> jeu <strong>de</strong><br />

paramètres<br />

En fonctionnem<strong>en</strong>t avec<br />

module sur FIF : défaut<br />

interne<br />

Le régulateur CAN affiche<br />

l’état "Avertissem<strong>en</strong>t" ou<br />

"BUS−OFF".<br />

Le participant ne répond pas<br />

ou n’est pas connecté.<br />

En fonctionnem<strong>en</strong>t avec E/S<br />

application :<br />

paramétrage incorrect du<br />

changem<strong>en</strong>t <strong>de</strong> jeu <strong>de</strong><br />

paramètres<br />

Un signal numérique affecté<br />

<strong>de</strong> la fonction "mise <strong>en</strong><br />

défaut" (TRIP−Set) a été<br />

activé.<br />

Divers<br />

Remè<strong>de</strong><br />

Vérifier le câblage du Bus<br />

Système.<br />

Vérifier la configuration du<br />

Bus Système.<br />

Pour tous les jeux <strong>de</strong> paramètres,<br />

le signal "changem<strong>en</strong>t <strong>de</strong> jeu <strong>de</strong><br />

paramètres" (C0410/13,<br />

C0410/14) doit être affecté à la<br />

même source !<br />

Contacter votre service L<strong>en</strong>ze.<br />

Vérifier la terminaison du bus.<br />

Vérifier le blindage <strong>de</strong>s câbles.<br />

Vérifier le câblage PE.<br />

Vérifier le coeffici<strong>en</strong>t<br />

d’utilisation bus ;<br />

év<strong>en</strong>tuellem<strong>en</strong>t, réduire le<br />

taux <strong>de</strong> transmission.<br />

Vérifier la terminaison du bus.<br />

Vérifier le blindage <strong>de</strong>s câbles.<br />

Vérifier le câblage PE.<br />

Vérifier le coeffici<strong>en</strong>t<br />

d’utilisation ; év<strong>en</strong>tuellem<strong>en</strong>t,<br />

réduire le taux <strong>de</strong><br />

transmission.<br />

Pour tous les jeux <strong>de</strong> paramètres,<br />

le signal "changem<strong>en</strong>t <strong>de</strong> jeu <strong>de</strong><br />

paramètres" (C0410/13,<br />

C0410/14) doit être affecté à la<br />

même source !<br />

Vérifier le co<strong>de</strong>ur externe.<br />

Contacter votre service L<strong>en</strong>ze.<br />

196<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

L


Clavier <strong>de</strong><br />

comman<strong>de</strong><br />

FAn1<br />

<br />

PC 1)<br />

Détection et élimination <strong>de</strong>s défauts<br />

Défaut<br />

95 Module<br />

v<strong>en</strong>tilateur<br />

E<strong>82</strong>ZMV<br />

(<strong>82</strong>00 <strong>motec</strong><br />

3 ... 7,5 <strong>kW</strong><br />

Origine<br />

Module v<strong>en</strong>tilateur<br />

<strong>en</strong>dommagé<br />

FAn1 − uniquem<strong>en</strong>t) : Module v<strong>en</strong>tilateur non ou<br />

défaut TRIP ou mal connecté<br />

avertissem<strong>en</strong>t<br />

configurable <strong>en</strong><br />

C0608<br />

H05<br />

<br />

id1<br />

<br />

LP1<br />

<br />

Messages <strong>de</strong> défaut<br />

Remè<strong>de</strong><br />

8<br />

Remplacer le module v<strong>en</strong>tilateur.<br />

Raccor<strong>de</strong>r le module v<strong>en</strong>tilateur.<br />

Vérifier le câblage.<br />

105 Défaut interne Contacter votre service L<strong>en</strong>ze.<br />

140 I<strong>de</strong>ntification <strong>de</strong><br />

paramètres<br />

erronée<br />

32 Défaut <strong>de</strong> phase<br />

moteur<br />

(affichage si<br />

C0597 = 1)<br />

LP1 1<strong>82</strong> Défaut <strong>de</strong> phase<br />

moteur<br />

(affichage si<br />

C0597 = 2)<br />

LU<br />

<br />

OC1<br />

<br />

OC2<br />

<br />

−<br />

Sous−t<strong>en</strong>sion du<br />

bus CC<br />

Moteur non connecté<br />

Raccor<strong>de</strong>r le moteur.<br />

Défaillance d’une ou <strong>de</strong> Vérifier les câbles moteur.<br />

plusieurs phases moteur Vérifier l’accroissem<strong>en</strong>t U min .<br />

Courant moteur trop faible Raccor<strong>de</strong>r un moteur à<br />

puissance adéquate ou<br />

adapter le moteur <strong>en</strong> C0599.<br />

T<strong>en</strong>sion réseau trop faible<br />

T<strong>en</strong>sion du réseau CC trop<br />

faible<br />

Variateur 400 V connecté sur<br />

réseau 240 V<br />

Vérifier la t<strong>en</strong>sion réseau.<br />

Vérifier le module d’alim<strong>en</strong>tation.<br />

Connecter le variateur à<br />

l’alim<strong>en</strong>tation adéquate.<br />

11 Court−circuit Court−circuit Chercher la cause du<br />

court−circuit ; vérifier le câble<br />

moteur.<br />

Vérifier la résistance <strong>de</strong><br />

<strong>fr</strong>einage et le câble <strong>de</strong><br />

résistance <strong>de</strong> <strong>fr</strong>einage.<br />

Courant <strong>de</strong> charge capacitif<br />

du câble moteur trop élevé<br />

12 Mise à la terre Court−circuit à la masse<br />

d’une phase moteur<br />

Courant <strong>de</strong> charge capacitif<br />

du câble moteur trop élevé<br />

Utiliser <strong>de</strong>s câbles moteurs plus<br />

courts ou avec une capacité <strong>de</strong><br />

charge plus faible.<br />

Vérifier le moteur ; vérifier le<br />

câble moteur.<br />

Utiliser <strong>de</strong>s câbles moteurs plus<br />

courts ou avec une capacité <strong>de</strong><br />

charge plus faible.<br />

Désactiver la détection <strong>de</strong> mise à<br />

la terre à <strong>de</strong>s fins <strong>de</strong> contrôle.<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 197


8<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong><br />

OC3<br />

<br />

OC4<br />

<br />

OC5<br />

<br />

OC6<br />

<br />

OH<br />

<br />

OH<br />

<br />

OH3<br />

<br />

OH4<br />

<br />

198<br />

Détection et élimination <strong>de</strong>s défauts<br />

Messages <strong>de</strong> défaut<br />

PC 1)<br />

Défaut<br />

13 Surint<strong>en</strong>sité <strong>en</strong><br />

phase<br />

d’accélération ou<br />

court−circuit<br />

14 Surint<strong>en</strong>sité <strong>en</strong><br />

phase <strong>de</strong><br />

décélération<br />

15 Surcharge<br />

variateur <strong>en</strong><br />

fonctionnem<strong>en</strong>t<br />

stationnaire<br />

16 Surcharge moteur<br />

(surcharge I 2 x t)<br />

50 Température<br />

radiateur<br />

> +85 °C<br />

− Température<br />

radiateur<br />

> +80 °C<br />

53 Surveillance PTC<br />

(TRIP)<br />

(affichage si<br />

C0119 = 1 ou 4)<br />

54 Surtempérature<br />

variateur<br />

OH51 203 Surveillance PTC<br />

(affichage si<br />

C0119 = 2 ou 5)<br />

Origine<br />

Temps d’accélération (C0012)<br />

trop court<br />

Câble moteur défectueux<br />

Court−circuit <strong>en</strong>tre spires<br />

moteur<br />

Temps <strong>de</strong> décélération<br />

(C0013) réglé trop court<br />

Surcharge courante et trop<br />

longue<br />

Surcharge thermique du<br />

moteur. Causes possibles :<br />

courant perman<strong>en</strong>t<br />

inadmissible,<br />

accélérations nombreuses<br />

ou trop longues avec<br />

surint<strong>en</strong>sité<br />

T<strong>en</strong>sion ambiante trop élevée<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />

Remè<strong>de</strong><br />

Augm<strong>en</strong>ter le temps<br />

d’accélération.<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t<br />

<strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t.<br />

Vérifier le câblage.<br />

Vérifier le moteur.<br />

Augm<strong>en</strong>ter le temps <strong>de</strong><br />

décélération.<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t<br />

<strong>de</strong> la résistance <strong>de</strong> <strong>fr</strong>einage<br />

externe.<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t <strong>de</strong><br />

l’<strong>en</strong>traînem<strong>en</strong>t.<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t<br />

<strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t.<br />

Vérifier le réglage <strong>de</strong> C0120.<br />

Laisser re<strong>fr</strong>oidir l’appareil et<br />

assurer une meilleure v<strong>en</strong>tilation.<br />

Radiateur poussiéreux Nettoyer le radiateur.<br />

Courants trop élevés et<br />

accélérations nombreuses et<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t<br />

<strong>de</strong> l’<strong>en</strong>traînem<strong>en</strong>t.<br />

trop longues<br />

Vérifier la charge, remplacer<br />

<strong>de</strong>s roulem<strong>en</strong>ts durs et<br />

défectueux.<br />

Moteur trop chaud <strong>en</strong> raison<br />

<strong>de</strong>s courants trop élevés et<br />

<strong>de</strong>s accélérations<br />

nombreuses et trop longues<br />

PTC non ou mal connectée<br />

Surtempérature à l’intérieur<br />

du variateur<br />

Moteur trop chaud <strong>en</strong> raison<br />

<strong>de</strong>s courants trop élevés et<br />

<strong>de</strong>s accélérations<br />

nombreuses et trop longues<br />

PTC non ou mal connectée<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t <strong>de</strong><br />

l’<strong>en</strong>traînem<strong>en</strong>t.<br />

Raccor<strong>de</strong>r la son<strong>de</strong> PTC ou<br />

déconnecter la surveillance.<br />

Réduire la charge du variateur.<br />

Améliorer le re<strong>fr</strong>oidissem<strong>en</strong>t.<br />

Vérifier le v<strong>en</strong>tilateur sur le<br />

variateur.<br />

Vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t <strong>de</strong><br />

l’<strong>en</strong>traînem<strong>en</strong>t.<br />

Raccor<strong>de</strong>r la son<strong>de</strong> PTC ou<br />

déconnecter la surveillance.<br />

L


Clavier <strong>de</strong><br />

comman<strong>de</strong><br />

OU<br />

<br />

OUE<br />

<br />

Pr<br />

<br />

Pr1<br />

<br />

Pr2<br />

<br />

Pr3<br />

<br />

Pr4<br />

<br />

Pr5<br />

<br />

Pt5<br />

<br />

rSt<br />

<br />

PC 1)<br />

Détection et élimination <strong>de</strong>s défauts<br />

Défaut<br />

Origine<br />

Messages <strong>de</strong> défaut<br />

Remè<strong>de</strong><br />

− Surt<strong>en</strong>sion du bus T<strong>en</strong>sion réseau trop élevée Vérifier la t<strong>en</strong>sion réseau.<br />

CC<br />

22 (message ou Fonctionnem<strong>en</strong>t <strong>en</strong> <strong>fr</strong>einage Augm<strong>en</strong>ter les temps <strong>de</strong><br />

défaut TRIP<br />

décélération.<br />

configurable <strong>en</strong><br />

En fonctionnem<strong>en</strong>t avec<br />

C0310)<br />

résistance <strong>de</strong> <strong>fr</strong>einage externe<br />

:<br />

– vérifier le dim<strong>en</strong>sionnem<strong>en</strong>t,<br />

le raccor<strong>de</strong>m<strong>en</strong>t et le câble<br />

<strong>de</strong> la résistance <strong>de</strong> <strong>fr</strong>einage,<br />

– augm<strong>en</strong>ter les temps <strong>de</strong><br />

décélération.<br />

75 Transfert <strong>de</strong><br />

paramètres via<br />

clavier erroné<br />

72 Transfert via<br />

clavier <strong>de</strong><br />

comman<strong>de</strong> <strong>de</strong><br />

PAR1 erroné<br />

73 Transfert via<br />

clavier <strong>de</strong><br />

comman<strong>de</strong> <strong>de</strong><br />

PAR2 erroné<br />

77 Transfert via<br />

clavier <strong>de</strong><br />

comman<strong>de</strong> <strong>de</strong><br />

PAR3 erroné<br />

78 Transfert via<br />

clavier <strong>de</strong><br />

comman<strong>de</strong> <strong>de</strong><br />

PAR4 erroné<br />

Mise à la terre rampante du<br />

côté moteur<br />

Tous les jeux <strong>de</strong> paramètres<br />

sont défectueux.<br />

PAR1 défectueux<br />

PAR2 défectueux<br />

PAR3 défectueux<br />

PAR4 défectueux<br />

8<br />

Vérifier s’il y a mise à la terre du<br />

câble moteur et du moteur<br />

(déconnecter le moteur du<br />

variateur).<br />

Avant <strong>de</strong> débloquer le variateur,<br />

r<strong>en</strong>ouveler impérativem<strong>en</strong>t le<br />

transfert <strong>de</strong> données ou charger<br />

le réglage L<strong>en</strong>ze.<br />

79 Défaut interne Contacter votre service L<strong>en</strong>ze.<br />

81 Défaut <strong>de</strong> temps<br />

lors du transfert<br />

<strong>de</strong>s paramètres<br />

76 Erreur<br />

réarmem<strong>en</strong>t<br />

automatique du<br />

défaut<br />

(Auto−TRIP−Reset)<br />

Le transfert <strong>de</strong>s données <strong>en</strong><br />

prov<strong>en</strong>ance du clavier ou du<br />

PC a été interrompu (exemple<br />

: le clavier <strong>de</strong> comman<strong>de</strong> a<br />

été retiré p<strong>en</strong>dant le<br />

transfert).<br />

Plus <strong>de</strong> 8 messages <strong>de</strong><br />

défaut <strong>en</strong> 10 minutes<br />

Avant <strong>de</strong> débloquer le variateur,<br />

r<strong>en</strong>ouveler impérativem<strong>en</strong>t le<br />

transfert <strong>de</strong> données ou charger<br />

le réglage L<strong>en</strong>ze.<br />

En fonction du message <strong>de</strong><br />

défaut<br />

L<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0 199


8<br />

Clavier <strong>de</strong><br />

comman<strong>de</strong><br />

sd5<br />

<br />

Détection et élimination <strong>de</strong>s défauts<br />

Messages <strong>de</strong> défaut<br />

PC 1)<br />

Défaut<br />

85 Rupture <strong>de</strong> fil sur<br />

<strong>en</strong>trée analogique<br />

1<br />

Origine<br />

Courant sur <strong>en</strong>trée<br />

analogique < 4 mA pour<br />

plage <strong>de</strong> consigne<br />

4 ... 20 mA<br />

Remè<strong>de</strong><br />

Fermer le circuit à l’<strong>en</strong>trée<br />

analogique.<br />

sd7<br />

<br />

87 Rupture <strong>de</strong> fil sur<br />

<strong>en</strong>trée analogique<br />

2<br />

1) N° défaut LECOM, affichage dans le programme <strong>de</strong> paramétrage Global Drive Control<br />

(GDC)<br />

200<br />

EDK<strong>82</strong>MV222 DE/EN/FR 8.0<br />