SECTION I: USER<br />

I.6.6<br />

SETTING THE DEFLECTOR<br />

In order to obtain optimal air distribution, regulate the position of the<br />

motor-driven deflector and the vertical fins, making sure that the air flow<br />

is not directly pointed at persons.<br />

The vertical fins must be manually oriented before starting the air<br />

conditioning unit, while you should proceed as follows for the motordriven<br />

deflector:<br />

The deflector position can be modified by pressing<br />

the AIR DIRECTION key several times.<br />

Press the SWING key to activate continuous<br />

deflector oscillation.<br />

ATTENTION:<br />

In order to transmit the timer settings automatically at the set time,<br />

position the remote control near the internal unit. The TIMER function is<br />

not repetitive and must be set every time it is used.<br />

When the Timer ON-OFF is selected , there can be a small delay for the<br />

start up of the unit with respect to the hour programmed in the timer.<br />

This is to be considered completely normal operation of the unit.<br />

I.6.9<br />

KEYPAD LOCK<br />

By pressing the LOCK key with a sharp<br />

object, it is possible to completely inhibit the<br />

remote control keypad, preventing<br />

undesired use (by children etc.). The<br />

display will show the symbol alongside. To<br />

remove the lock, press the LOCK key again<br />

with a sharp object.<br />

I.6.10<br />

RESETTING THE REMOTE CONTROL<br />

By pressing the RESET key with a sharp object, it<br />

is possible to take the remote control back to its<br />

original factory settings.<br />

I.7 DESCRIPTION OF INDICATORS<br />

The indicators on the right-hand side of the unit are for indicating the<br />

operational status of the machine.<br />

I.6.7<br />

DANGER!<br />

Moving the motor-driven deflector manually when<br />

the air conditioning unit is one could cause<br />

operating problems or damage the regulation<br />

system.<br />

FAN SETTINGS<br />

By pressing the FAN SPEED key several times, it is<br />

possible to set the speed of the fan between the<br />

three available, or activate the AUTO function.<br />

The display shows the operating mode.<br />

Indicators<br />

Meaning<br />

indicates that the unit is running, flashes after<br />

temporary interruption of the power supply<br />

indicates that the unit is running in ECONOMIC<br />

RUNNING mode<br />

indicates that the timer has been activated<br />

AUTO: Completely automatic operation<br />

LOW: minimum speed operation<br />

MED: medium speed operation<br />

HIGH: maximum speed operation<br />

indicates that the unit is in defrost or Anti Cold Air<br />

phase<br />

I.6.8<br />

SETTING THE TIMER<br />

By pressing these keys, it is possible to programme<br />

the start-up and/or the shutdown time of the unit.<br />

The display shows the TIMER ON and/or TIMER<br />

OFF indications, with part of the clock flashing.<br />

indicates that the unit is running in AUTO mode<br />

indicates the set temperature<br />

TIME ADJUST<br />

Start-up time<br />

Shutdown time<br />

By pressing this key, it is possible to programme the<br />

start-up or the shutdown time. With every press of<br />

the key, the time moves forwards or backwards by<br />

ten minutes.<br />

When the desired start-up or shutdown time is<br />

reached, the setting must be confirmed by pressing<br />

the OK key.<br />

The CANCEL key makes it possible to deactivate<br />

the TIMER ON and/or TIMER OFF functions.<br />

Once the start-up and shutdown times have<br />

been set, the display shows the current time<br />

and the messages TIMER ON and/or TIMER<br />

OFF with the relative times.<br />

I.8 PERIODS OUT OF USE<br />

DANGER!<br />

Always turn off the automatic main switch (IG) for<br />

the protection of the entire system. Make sure that<br />

no one accidentally supplies power to the machine<br />

– lock the automatic main switch in the off position.<br />

If the machine is going to be out of use for long periods of time, it is<br />

necessary to disconnect the unit from the mains by opening the main<br />

switch, fitted by the installer.<br />

I.9 START-UP AFTER PROLONGED SHUTDOWN<br />

Before starting up the unit again:<br />

• Clean or change the air filter.<br />

• Clean the heat-exchanger.<br />

• Clean the condensation collector tray drain tube or make sure it is<br />

clear.<br />

It is advisable to run the unit at maximum speed for several hours.<br />

26