SECTION I: USER<br />
I.6.1<br />
SETTING THE CLOCK<br />
When the batteries are inserted in the remote control, the clock<br />
indicator flashes and displays 0:00.<br />
NOTE: do not point the remote control towards the air conditioning unit<br />
when setting the clock.<br />
We recommend regulating the clock on the remote control before<br />
starting up the air conditioning unit. Proceed as follows in order to<br />
regulate it (ref. Fig. 1):<br />
press the TIME ADJUST key until<br />
reaching the desired time<br />
press OK in order to confirm the<br />
selection (do not point the remote<br />
control at the unit)<br />
In order to regulate the clock again or programme again, proceed as<br />
follows (ref. Fig. 1):<br />
press the CLOCK key for more than<br />
three seconds<br />
With the selection of the automatic programme AUTO, the air<br />
conditioning unit can operating in COOLING mode, VENTILATION<br />
mode and in HEATING mode on the basis of the temperature difference<br />
between the ambient temperature and the temperature selected on the<br />
remote control.<br />
The fan is in constant operation, whatever the difference between the<br />
ambient temperature and the selected temperature.<br />
When the cooling programme COOL is selected, the air conditioning<br />
unit operates with free temperature settings, lowering the ambient<br />
temperature.<br />
When the drying programme DRY is selected, the air conditioning unit<br />
operates at 4-6 minute intervals, with free temperature settings, thus<br />
progressively lowering the temperature and humidity in the<br />
environment. In the drying programme DRY, the FAN SPEED key<br />
cannot be used.<br />
When the unit is running in heating mode HEAT, the air conditioning<br />
unit operates with free temperature settings, raising the ambient<br />
temperature. With low temperature and high relative humidity external<br />
air conditions, some frost may form on the external heat exchanger that<br />
must be eliminated; the microprocessor board provides for this<br />
operation on the basis of a defined cycle, blocking the heating phase for<br />
periods varying from 6 to 10 minutes. This operation is signalled by the<br />
PRE-DEF LED.<br />
When the ventilation programme FAN is selected, the air conditioning<br />
unit operates without temperature settings, ventilating the ambient air.<br />
press the TIME ADJUST key until<br />
reaching the desired time<br />
press OK in order to confirm the<br />
selection (do not point the remote<br />
control at the unit)<br />
I.6.4<br />
I.6.4.1<br />
ECONOMIC RUNNING FUNCTION<br />
By pressing this key in the AUTO, COOL and HEAT<br />
modes when the unit is running, the air conditioning<br />
unit varies the set temperature over the following<br />
two hours, in COOL mode +2°C, in HEAT mode –<br />
2°C, and then maintains it throughout the operating<br />
time, obtaining greater comfort and energy saving.<br />
EMERGENCY FUNCTION<br />
I.6.2<br />
SWITCHING THE UNIT ON AND OFF<br />
The unit may be switched on or off by pressing the<br />
ON/OFF key.<br />
In going from ON to OFF, any operating mode is interrupted, timer<br />
delays in progress are cancelled, and the operating mode of the<br />
appliance and the fan, the position of the deflector and the preset<br />
temperature are memorised.<br />
In going from OFF to ON, the machine automatically restores the<br />
operating modes memorised before shutdown.<br />
When the unit is on, the unit on indication appears on<br />
the display.<br />
The presence of this symbol on the display indicates<br />
that the remote control is communicating with the unit.<br />
Every time the external unit compressor stops, at least 3 seconds must<br />
pass before it is started up again. This period of time is necessary to<br />
safeguard the compressor and may not be modified.<br />
I.6.3<br />
SETTING THE OPERATING MODE<br />
By pressing the Mode key several times, it is possible to<br />
change the operating mode of the unit. The operating<br />
mode selected appears on the display.<br />
AUTO: Completely automatic operation<br />
COOL: cooling mode<br />
DRY: drying mode<br />
HEAT: heating mode<br />
FAN: Ventilation only mode<br />
The emergency function can be used when the remote control is not<br />
available or the batteries are flat. By pressing the emergency operation<br />
button, located on the internal unit, the air conditioning unit can run as<br />
usual.<br />
If the emergency operating button is pressed once, the unit runs in<br />
AUTO mode.<br />
If it is pressed a second time, the unit will run in cooling mode on the<br />
basis of this programme:<br />
• set temperature 24°C<br />
• AUTOMATIC fan speed<br />
By pressing the emergency button a third time, the air conditioning unit<br />
will come to a stop.<br />
I.6.5<br />
Emergency button<br />
SETTING THE DESIRED TEMPERATURE<br />
By pressing these keys in the AUTO, COOL, DRY<br />
and HEAT mode, it is possible to increase or reduce<br />
the desired temperature value from 17°C to 30°C.<br />
The display shows the value of the temperature<br />
selected.<br />
25