04.11.2014 Views

AXW smart - Biral

AXW smart - Biral

AXW smart - Biral

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

58<br />

english<br />

9. Summary of malfunctions<br />

All poles of the supply voltage must be switched off<br />

and secured against reconnection without fail<br />

before removing the terminal box cover and before<br />

dismantling the pump at any time.<br />

Fault Cause Remedy<br />

Pump does not run No motor voltage Check switch and fuses,<br />

(no LED indication)<br />

check supply voltage<br />

Motor defective<br />

Change pump<br />

Short-circuit<br />

when pump switched on Mains wrongly connected Connect correctly<br />

Motor defective<br />

Change pump<br />

E1 lit red Sensor error forward flow (Pump changes<br />

Connection to forward<br />

to continuous operation.)<br />

flow sensor interrupted<br />

Check fitting of temperature<br />

sensor and connection<br />

of blue plug (4.6)<br />

E2 lit red Overheating (Pump switched off.<br />

The temperature<br />

It switches on again<br />

at the return flow sensor automatically after cooling.)<br />

above 85°C<br />

=> check system<br />

E3 lit red No heating of forward flow (Pump switched off)<br />

takes place with pump running: Acknowledge error message:<br />

dry running, boiler cold<br />

press control button,<br />

or non-return valve blocked possibly vent pump (6.2)<br />

E4 lit red Defective non-return valve (Pump runs in normal operation.)<br />

Error message can be reset<br />

by pressing control button.<br />

Check/replace non-return valve.<br />

Subject to technical modifications