C O N T A C T E U R S E T R E L A I S T H E R M I Q U E S<br />

DÉMARREURS DIRECTS AVEC COFFRET ÉTANCHE ISOLANT IP65<br />

Pour la protection contre les surcharges des moteurs électriques.<br />

SIGLE F<br />

50-60Hz<br />

V<br />

CODE<br />

220<br />

÷<br />

230<br />

HS1710Y<br />

HS2510Y<br />

HS1710Y<br />

HS2510Y<br />

W<br />

380<br />

÷<br />

400<br />

P<br />

P<br />

COURANT<br />

NOMINAL<br />

THERMIQUE<br />

Ith<br />

COURANT<br />

NOMINAL<br />

IN AC3-380V<br />

Ie<br />

PUISSANCES À COMMANDER<br />

DES MOTEURS TRIPHASÉS EN<br />

CATÉGORIE AC2-AC3<br />

220-240V 380-415V 500V<br />

DÉMARREURS DIRECTS AVEC TOUCHE DE REMISE EN MARCHE<br />

40 A<br />

40 A<br />

17 A<br />

25 A<br />

4 kW<br />

6 kW<br />

7.5 kW<br />

11 kW<br />

10 kW<br />

15 kW<br />

5.5 HP<br />

8 HP<br />

10.5 HP<br />

15 HP<br />

14 HP<br />

20 HP<br />

HR1710+JA25+UH25Y<br />

HR2510+JA25+UH25Y<br />

DÉMARREURS DIRECTS AVEC TOUCHES MARCHE-ARRÊT / REMISE EN MARCHE<br />

40 A<br />

40 A<br />

SIGLE A B C D E F G H I L M N O P Q<br />

17 A<br />

25 A<br />

0.15<br />

÷<br />

0.25<br />

0.22<br />

÷<br />

0.33<br />

CONTACTEURS AUXILIAIRES<br />

Pour le circuits où plusieurs contacts NO<br />

ou NF sont nécessaires pour satisfaire les<br />

CODE<br />

HX1040E<br />

SIGLE<br />

50 HZ-V<br />

60 HZ-V<br />

F<br />

0. 3<br />

÷<br />

0.45<br />

FUSIBLES DE AM 0.5 0.5 1 1 2 2 2 4 6 8 10 12 16 25<br />

PROTECTION<br />

(A) gl - - 2 2 4 4 4 4 6 10 16 20 25 50<br />

24<br />

SCHÉMA<br />

CONTACTS<br />

NOMBRE<br />

CONTACTS<br />

NO NF<br />

4<br />

4 kW<br />

5.5 HP<br />

6 kW<br />

8 HP<br />

COURANT<br />

NOMINAL<br />

THERMIQUE<br />

Ith<br />

0.42<br />

÷<br />

0.63<br />

0.6<br />

÷<br />

0.9<br />

G D U X C W B Z<br />

48 220 366<br />

110 220 ÷ 380<br />

240<br />

÷ ÷ ÷<br />

58 115 230 440 400<br />

0<br />

0.85<br />

÷<br />

1 .27<br />

7.5 kW<br />

10.5 HP<br />

11 kW<br />

15 HP<br />

1.2 1.7<br />

÷ ÷<br />

1 .75 2.6<br />

2.5<br />

÷<br />

3.7<br />

10 kW<br />

14 HP<br />

15 kW<br />

20 HP<br />

3.6<br />

÷<br />

5.4<br />

5.3<br />

÷<br />

7.5<br />

7.3<br />

÷<br />

10.2<br />

10<br />

÷<br />

15.7<br />

COMPOSITION<br />

13.5<br />

÷<br />

20<br />

18<br />

÷26<br />

40<br />

63<br />

HR1710+JA25+UH25YP<br />

HR1710+JA25+UH25YP<br />

exigences de schemà électriques<br />

complexes.<br />

440<br />

528<br />

480<br />

÷<br />

500<br />

COMMANDE EN<br />

COURANT ALTERNATIF<br />

AC-15<br />

220-240V 380-415V 500V<br />

COMMANDE EN<br />

COURANT CONTINUE<br />

DC-13<br />

220-240V 380-415V 500V<br />

10 A 3 A 1,5 A 1 A 0,5 A 0,35 A 0,25 A<br />

HX1031E<br />

3<br />

1<br />

10 A<br />

3 A 1,5 A 1 A<br />

0,5 A 0,35 A 0,25 A<br />

HX1022E<br />

2<br />

2<br />

10 A<br />

3 A 1,5 A 1 A<br />

0,5 A 0,35 A 0,25 A<br />

PLOTS DE CONTACTS AUXILIAIRES ET BLOCS MÉCANIQUES<br />

PLOTS DE CONTACTS AUXILIAIRES ISTANTANÉS<br />

IR02<br />

IR13<br />

IR11<br />

IR31<br />

IR22<br />

PLOTS DE CONTACTS AUXILIAIRES TEMPORISÉS<br />

IT60D<br />

IT60I<br />

PLOTS DE CONTACTS AUXILIAIRES<br />

SIGLE<br />

F G D U<br />

IDC10<br />

IDC01<br />

Tension de bobine en c.a. 24V 48V 110V 230V<br />

MONTAGE SEPARÉ<br />

I82<br />

montage separé pour JA46<br />

I84<br />

montage separé pour JA25<br />

[32]<br />

BLOC MÉCANIQUE<br />

I85 bloc mécanique pour HR