GESTRA Steam Systems<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong><br />

<strong>NRG</strong> <strong>17</strong>-<strong>12</strong><br />

<strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

FR<br />

Français<br />

Instructions de montage et de mise en service<br />

818893-00<br />

Electrode de niveau<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>


Contenu<br />

Remarques importantes<br />

Page<br />

Utilisation conforme................................................................................................................................4<br />

Consigne de sécurité...............................................................................................................................4<br />

Danger....................................................................................................................................................4<br />

Attention.................................................................................................................................................4<br />

ATEX (Atmosphère Explosible).................................................................................................................4<br />

Explications<br />

Conditionnement.....................................................................................................................................5<br />

Description du système...........................................................................................................................5<br />

Fonction..................................................................................................................................................6<br />

Composants du système.........................................................................................................................6<br />

Exécution................................................................................................................................................6<br />

Données techniques<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>........................................................................................................7<br />

Résistance à la corrosion.........................................................................................................................8<br />

Dimensionnement...................................................................................................................................8<br />

Plaque d’identification/Marquage............................................................................................................8<br />

Dimensions <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>........................................................................................................9<br />

Dimensions <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>.........................................................................................................................10<br />

Structure<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>......................................................................................................11<br />

Légende................................................................................................................................................14<br />

Eléments fonctionnels<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>......................................................................................................<strong>12</strong><br />

En option pour <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>...............................................................................13<br />

Légende................................................................................................................................................14<br />

Montage<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>, étape 1........................................................................................15<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>, étape 2........................................................................................15<br />

Attention...............................................................................................................................................15<br />

Remarque.............................................................................................................................................<strong>16</strong><br />

Outils....................................................................................................................................................<strong>16</strong><br />

<br />

Exemples de montage<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>......................................................................................................<strong>17</strong><br />

Légende................................................................................................................................................18


Contenu suite<br />

Raccordement électrique<br />

Page<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>......................................................................................................<strong>19</strong><br />

En option pour <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>...............................................................................<strong>19</strong><br />

Schéma de raccordement.....................................................................................................................20<br />

Tableau des tensions.............................................................................................................................21<br />

Remarque.............................................................................................................................................21<br />

Outils....................................................................................................................................................21<br />

Mise en service<br />

Contrôler le raccordement électrique.....................................................................................................21<br />

Etablir l’alimentation électrique ............................................................................................................21<br />

Service<br />

Sécurité de niveau d’eau élevé..............................................................................................................22<br />

Remarque.............................................................................................................................................22<br />

Dysfonctionnements en service<br />

Liste de contrôle des défauts pour dysfonctionnements en service........................................................22<br />

Mise hors service<br />

Danger..................................................................................................................................................23<br />

Elimination............................................................................................................................................23


Remarques importantes<br />

Utilisation conforme<br />

Utiliser les électrodes de niveau <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong> et <strong>NRG</strong> <strong>19</strong>-<strong>12</strong> uniquement avec l’indicateur<br />

de niveau NRS 1-8 comme sécurité de niveau d’eau élevé (limiteur NH). L’appareil ne doit pas être<br />

utilisé dans des zones présentant un risque d’explosion.<br />

Consigne de sécurité<br />

L’appareil ne peut être monté et mis en service que par des personnes aptes et initiées. Les travaux<br />

d’entretien et de conversion ne peuvent être effectués que par des employés autorisés ayant suivi une<br />

formation spécifique.<br />

Danger<br />

De la vapeur ou de l’eau très chaude peut sortir lorsque l’on dégage l’électrode !<br />

De graves brûlures sont possibles sur tout le corps !<br />

Démonter l’électrode de niveau uniquement lorsque la pression de la chaudière est de<br />

0 bar !<br />

L’électrode est brûlante pendant le service !<br />

De graves brûlures aux mains et aux bras sont possibles.<br />

Effectuer les travaux de montage ou d’entretien uniquement lorsque l’installation est<br />

froide !<br />

Attention<br />

La plaque d'identification indique les propriétés techniques de l’appareil.<br />

Un appareil sans plaque d’identification spécifique ne peut être mis en service ou<br />

exploité !<br />

ATEX ( Atmosphère Explosible)<br />

Suivant DIN EN 50020 par. 5.4, les appareils sont de simples matériels électriques. Conformément à la<br />

directive européenne 94/9/CE, les appareils doivent être utilisés dans les zones présentant un risque<br />

d’explosion uniquement avec des barrières Zéner.<br />

Utilisables en zones Ex 1, 2 (<strong>19</strong>99/92/CE).<br />

Les appareils ne reçoivent pas de marquage Ex.<br />

L’utilité des barrières Zéner est certifiée dans un avis d’expert séparé.


Explications<br />

Conditionnement<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong><br />

1 électrode de niveau <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, PN 40<br />

1 joint D 27x32 DIN 7603-1.4301, recuit blanc<br />

1 rondelle avec vis sans tête (agrandissement de surface de mesure) (en option)<br />

1 rondelle d’arrêt (en option)<br />

1 exemplaire des instructions de montage et de mise en service<br />

<strong>NRG</strong> <strong>17</strong>-<strong>12</strong><br />

1 électrode de niveau <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, PN 63<br />

1 joint D 27x32 DIN 7603-1.4301, recuit blanc<br />

1 rondelle avec vis sans tête (agrandissement de surface de mesure) (en option)<br />

1 rondelle d’arrêt (en option)<br />

1 exemplaire des instructions de montage et de mise en service<br />

<strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

1 électrode de niveau <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>, PN <strong>16</strong>0<br />

1 joint D 27x32 DIN 7603-1.4301, recuit blanc<br />

1 rondelle avec vis sans tête (agrandissement de surface de mesure) (en option)<br />

1 rondelle d’arrêt (en option)<br />

1 exemplaire des instructions de montage et de mise en service<br />

Description du système<br />

Les électrodes de niveau <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong> et <strong>NRG</strong> <strong>19</strong>-<strong>12</strong> détectent le niveau de remplissage<br />

maximal (niveau haut) dans un générateur de vapeur selon la méthode de mesure conductive. La <strong>NRG</strong><br />

1...-<strong>12</strong> peut signaler au maximum un niveau de remplissage dans un fluide conducteur d’électricité :<br />

n Alarme niveau haut (alarme NH)<br />

La <strong>NRG</strong> 1...-<strong>12</strong> fonctionne en association avec l'indicateur de niveau NRS 1-8 comme sécurité de<br />

niveau d’eau élevé « de construction particulière » avec autotest périodique.<br />

Utilisation dans les installations à vapeur et à eau surchauffée suivant TRD 604, pages 1 et 2 (service<br />

24 h/72 h).<br />

L’installation électrique satisfait aux règles de la technique des circuits de sécurité EN 50156-1.


Explications suite<br />

Fonction<br />

La sécurité de niveau d’eau élevé est une combinaison d’appareils comprenant l’électrode de niveau<br />

<strong>NRG</strong> 1...-<strong>12</strong> et l’indicateur de niveau GESTRA NRS 1-8. L’électrode de niveau <strong>NRG</strong> 1...-<strong>12</strong> est une<br />

électrode de mesure assurant l’étanchéité. L’électrode est isolée au moyen d’une gaine en plastique.<br />

La sécurité de niveau d’eau élevé fonctionne selon le principe de mesure conductive. La conductibilité<br />

électrique de l’eau est une condition essentielle pour le fonctionnement. En service normal<br />

sans défaut, l’électrode de niveau n’est pas immergée dans l’eau de la chaudière, aucune alarme NH<br />

n’est signalée. L’alarme NH est signalée dès lors que la tige de l’électrode est immergée dans l’eau<br />

de chaudière pendant plus de 3 secondes. L’alarme NH est signalée lorsque l’électrode de niveau<br />

n’est pas étanche et l’eau pénètre à l’intérieur du corps. A chaque alarme NH, il convient de contrôler<br />

d’abord le niveau d’eau dans le verre de regard sur le générateur de vapeur. De par sa construction,<br />

la combinaison d’appareils <strong>NRG</strong> 1...-<strong>12</strong> et NRS 1-8 est selon TRD 604 « à sécurité intégrée ».<br />

Composants du système<br />

NRS 1-8<br />

Indicateur de niveau NRS 1-8. Limiteur à double redondance avec autotest périodique selon<br />

EN 50156-1.<br />

Exécution<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

Raccordement mécanique : filetage G ¾, ISO 228-1,<br />

Raccordement électrique : connecteur quatre pôles / tête de raccordement en aluminium (en option)


Données techniques<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

Numéro d’homologation TÜV<br />

TÜV · 01-02 - 01<strong>12</strong><br />

Pression de service<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong> : 32 bar à 238 °C<br />

<strong>NRG</strong> <strong>17</strong>-<strong>12</strong> : 46 bar à 260 °C<br />

<strong>NRG</strong> <strong>19</strong>-<strong>12</strong> : 100 bar à 311 °C<br />

Raccordement mécanique<br />

Filetage G ¾, ISO 228-1<br />

Matières<br />

Tube d’habillage 1.0715, 11SMn30<br />

Corps à visser 1.4571, X6CrNiMoTi<strong>17</strong>-<strong>12</strong>-2<br />

Électrode de mesure 1.4401, X5CrNiMo<strong>17</strong>-<strong>12</strong>-2<br />

Isolation d’électrode PEEK<br />

Connecteur quatre pôles polyamide (PA)<br />

Tête de raccordement 3.2<strong>16</strong>1 G AlSi8Cu3 (en option)<br />

Longueurs fournies<br />

500 mm<br />

1 000 mm<br />

1 500 mm<br />

Constante de cellule C<br />

0,13 cm -1 avec agrandissement de la surface de mesure<br />

0,3 cm -1 sans agrandissement de la surface de mesure<br />

Sensibilité de réponse<br />

10 µS/cm à 25 °C, constante de cellule 0,3 cm -1<br />

0,5 µS/cm à 25 °C, constante de cellule 0,13 cm -1<br />

Raccordement électrique<br />

Connecteur quatre pôles, raccords vissés de câble M <strong>16</strong><br />

Tête de raccordement en aluminium, raccords vissés de câble M <strong>16</strong> (en option)<br />

Protection<br />

IP 65 selon EN 60529<br />

Température ambiante maxi<br />

admissible 70 °C<br />

Poids<br />

env. 1,1 kg


Données techniques suite<br />

Résistance à la corrosion<br />

Lorsque l’utilisation est conforme, la sécurité de l’appareil n’est pas mise en péril par la corrosion.<br />

Dimensionnement<br />

Le corps n’est pas conçu pour une charge ondulée. Les soudures et les brides sont calculées en ce qui<br />

concerne la résistance à la flexion/aux sollicitations cycliques. Le dimensionnement et les adjuvants<br />

contre la corrosion sont faits dans les règles de l'art.<br />

Plaque d’identification/ Marquage<br />

Marquage de l’appareil<br />

Fig. 1<br />

Fig. 2 Fig. 3


Données techniques suite<br />

Dimensions <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong><br />

85<br />

≤ 1500<br />

<strong>16</strong>5<br />

272<br />

G¾, ISO 228-1 G¾, ISO 228-1<br />

85<br />

30<br />

30<br />

8<br />

≤ 1500<br />

23<br />

Fig. 4<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong> avec<br />

agrandissement de la surface de mesure<br />

Fig. 5<br />

<strong>NRG</strong> <strong>17</strong>-<strong>12</strong> sans<br />

agrandissement de la surface de mesure


Données techniques suite<br />

Dimensions <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

283<br />

G¾, ISO 228-1<br />

<strong>12</strong>0<br />

30<br />

≤ 1500<br />

Fig. 6<br />

<strong>NRG</strong> <strong>19</strong>-<strong>12</strong> sans<br />

agrandissement de la surface de mesure<br />

10


Structure<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

1<br />

2<br />

a<br />

3<br />

4<br />

8<br />

9<br />

0<br />

5 6<br />

7<br />

Fig. 7 Fig. 8<br />

∅ 33<br />

G¾, ISO 228-1<br />

N 8<br />

N 10<br />

0,5<br />

Fig. 9 Fig. 10<br />

11


Eléments fonctionnels<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

b<br />

c<br />

h<br />

d<br />

i<br />

e<br />

f<br />

g<br />

Fig. 11<br />

<strong>12</strong>


Eléments fonctionnels suite<br />

En option pour <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

Fig. <strong>12</strong><br />

j k<br />

l k<br />

m<br />

n<br />

o<br />

Fig. 13<br />

13


Structure / Eléments fonctionnels suite<br />

Légende<br />

1 Pointe d’électrode<br />

2 Orifice<br />

3 Ressort de sécurité<br />

4 Tige d’électrode<br />

5 Vis sans tête<br />

6 Rondelle (agrandissement de la surface de mesure)<br />

7 Rondelle d’arrêt<br />

8 Joint 27 x 32, D, DIN 7603, 1.4301, recuit blanc<br />

9 Siège<br />

0 Filetage de l’électrode<br />

a Calorifugeage à fournir, d = 20 mm (à l’extérieur du calorifugeage du générateur de vapeur)<br />

b Vis M 4<br />

c Couvercle<br />

d Partie supérieure du connecteur<br />

e Plaque de raccordement<br />

f Rondelle d'étanchéité<br />

g Plaque de contact de l’électrode de niveau<br />

h Serre-câble<br />

i Raccord vissé de câble M <strong>16</strong> (PG 9)<br />

j Vis de corps M 4<br />

k Entrées de câble M 20 x 1,5<br />

l Couvercle<br />

m Ecrou<br />

n Raccordement PE<br />

o Bornier<br />

14


Montage<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>, étape 1<br />

1. Visser la tige d’électrode 4 dans la pointe d’électrode 1. Fig. 7<br />

2. Déterminer la longueur de mesure nécessaire de l’électrode. Tenir compte de la longueur minimale.<br />

3. Repérer la dimension sur la tige d’électrode 4.<br />

4. Dévisser la tige d’électrode 4 de la pointe d'électrode 1 et la raccourcir.<br />

5. Après examen visuel, visser à fond la tige 4 dans la pointe d’électrode 1. Glisser le ressort de<br />

sécurité 3 sur la tige d’électrode 4 jusqu’à ce qu’il soit fixé dans l’orifice 2.<br />

6. Glisser la rondelle 6 sur la tige de sorte que la tige dépasse le dessous de la rondelle de 2 mm.<br />

Fixer la rondelle dans cette position avec la vis sans tête 5. Enfoncer la rondelle d’arrêt fournie 7<br />

par dessous sur la tige de l’électrode contre la rondelle 6.<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong>, étape 2<br />

1. Contrôler les surfaces d’étanchéité. Fig. 10<br />

2. Poser le joint fourni 8 sur le siège 9 de l’électrode. Fig. 8<br />

3. Enduire le filetage de l’électrode 0 d’un peu de graisse silicone (par. ex. WINIX ® 2150).<br />

4. Visser l’électrode de niveau dans le raccord fileté de la bouteille ou dans le couvercle et serrer à<br />

fond avec une clé plate de 36. Le couple de serrage à froid est de <strong>16</strong>0 Nm.<br />

Attention<br />

n Les surfaces d’étanchéité du couvercle doivent être parfaitement usinées du point de<br />

vue technique selon la Fig. 10 !<br />

n Pour l’utilisation dans des générateurs de vapeur haute pression, utiliser uniquement<br />

la bride à chapeau GESTRA-PN-<strong>16</strong>0 !<br />

n Ne pas déformer l’électrode de mesure lors du montage !<br />

n Seul le joint fourni D 27x32 DIN 7603-1.4301 doit être utilisé !<br />

n Ne pas inclure le corps de l’électrode dans le calorifugeage de la chaudière !<br />

n Ne pas étanchéifier le filetage de l’électrode avec du chanvre ou une bande en téflon !<br />

n Ne pas enduire le filetage de l’électrode de pâtes conductrices ni de graisses !<br />

n Le chemin de fuite électrique entre l’électrode et la masse (bride, paroi de la bouteille)<br />

ne doit pas être inférieur à 14 mm ! Fig. 14, Fig. 15<br />

n Les dégagements minimaux doivent être respectés pour le montage de l’électrode !<br />

WINIX est une marque déposée de WINIX GmbH, Norderstedt, Allemagne<br />

15


Montage suite<br />

Remarque<br />

n Le contrôle du raccord avec bride de la chaudière doit être effectué dans le cadre du<br />

contrôle préliminaire de la chaudière.<br />

n Quatre exemples de montage sont représentés à la page <strong>17</strong>.<br />

n L’angle d’inclinaison de l’électrode doit être de 45° au maximum, la longueur de la<br />

tige d’électrode est limitée à 1 000 mm. Fig. 15<br />

n En cas de montage à l’extérieur, l’électrode de niveau doit être équipée d’un capot<br />

de protection contre les intempéries GESTRA. Comme alternative, il est possible de<br />

doter l’électrode de niveau d’une tête de raccordement en aluminium.<br />

Outils<br />

n Clé plate de 13, DIN 3110, ISO 3318<br />

n Clé plate de 36, DIN 3110, ISO 3318<br />

n Pointe à tracer<br />

n Scie à métaux<br />

n Lime plate, taille 2 , DIN 7261, A<br />

<strong>16</strong>


Exemples de montage<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

G ¾<br />

DN 50<br />

p<br />

q<br />

45°<br />

w<br />

s<br />

∅ 20<br />

20<br />

r<br />

Fig. 14<br />

≤ 90°<br />

∅ 20<br />

t<br />

u<br />

x<br />

y<br />

Fig. 15<br />

≥14<br />

20<br />

G ¾<br />

maxi 1 000<br />

p<br />

G ¾<br />

G ¾<br />

p<br />

q<br />

≥ DN 20<br />

≤ 20<br />

s<br />

r<br />

20<br />

∅ 20<br />

≤ 90°<br />

DN 100<br />

24,5 24,5<br />

s<br />

≤ 3000<br />

t<br />

v<br />

w<br />

s<br />

x<br />

y<br />

≥ DN 20<br />

Distance centre à centre<br />

≥ 10<br />

t<br />

x<br />

∅ 20<br />

Fig. <strong>16</strong><br />

Fig. <strong>17</strong><br />

≥ DN 20<br />

<strong>17</strong>


Exemples de montage suite<br />

Légende<br />

p Brides PN 40, PN 63, PN <strong>16</strong>0, DN 50, DIN 2501-1 (électrode unique)<br />

brides PN 40, PN 63, PN <strong>16</strong>0, DN 100, DIN 2501-1 (combinaison d’électrodes)<br />

q Effectuer le contrôle préliminaire du raccord avec bride dans le cadre du contrôle de la chaudière.<br />

r Orifice d’équilibrage Placer l’orifice aussi près que possible de la paroi de la chaudière !<br />

s Niveau d’eau haut NH<br />

t Tige d’électrode d = 8 mm<br />

u Tube de protection anti-turbulence DN 80, ≥ DN 100 selon l’association de normalisation française<br />

v Tube de protection anti-turbulence DN 100<br />

w Ecartement des électrodes ≥ 14 mm (distances d’isolation)<br />

x Niveau d’eau bas NB<br />

y Pièce de réduction DIN 26<strong>16</strong>-2, K-88,9 x 3,2- 42,4 x 2,6 W<br />

18


Raccordement électrique<br />

<strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

Raccordement électrique avec connecteur quatre pôles.<br />

L’alimentation de l’électrode requiert un câble blindé à quatre fils (par ex. I-Y(St)Y 2 x 2 x 0,8 ou<br />

LIYCY 4 x 0,5 mm 2 .<br />

Longueur maximale de 100 m avec une conductibilité à partir de 10 µS/cm.<br />

Longueur maximale de 30 m avec une conductibilité à partir de 0,5 µS/cm.<br />

Longueur maximale de 15 m avec une conductibilité à partir de 0,5 µS/cm et utilisation de l’appareil<br />

supplémentaire URN 1 (24 V DC).<br />

1. Desserrer la vis b. Fig. 11<br />

2. Retirer la tête de raccordement de l’électrode de niveau, laisser la rondelle caoutchouc f sur la<br />

plaque de contact g.<br />

3. Enlever le couvercle c.<br />

4. Faire sortir la plaque de raccordement e de la partie supérieure du connecteur d en appuyant.<br />

La partie supérieure du connecteur peut être tournée par étapes de 90°.<br />

5. Démonter le raccord vissé de câble i et le serre-câble h de la partie supérieure du connecteur<br />

d.<br />

6. Guider le câble dans le raccord vissé de câble i et la partie supérieure du connecteur d et affecter<br />

les bornes de la plaque de raccordement e suivant le schéma de raccordement.<br />

7. Faire entrer la plaque de raccordement e dans la partie supérieure du connecteur en appuyant,<br />

aligner le câble.<br />

8. Fixer le câble avec le serre-câble h et le raccord vissé de câble i.<br />

9. Mettre le couvercle c en place et introduire la vis b dans celui-ci.<br />

10. Placer la partie supérieure du connecteur sur l’électrode de niveau et la fixer avec la vis b.<br />

En option pour <strong>NRG</strong> <strong>16</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>17</strong>-<strong>12</strong>, <strong>NRG</strong> <strong>19</strong>-<strong>12</strong><br />

Raccordement électrique avec tête de raccordement en aluminium.<br />

L’alimentation de l’électrode requiert un câble blindé à quatre fils (par ex. I-Y(St)Y 2 x 2 x 0,8 ou<br />

LIYCY 4 x 0,5 mm 2 .<br />

Longueur maximale de 30 m avec une conductibilité à partir de 0,5 µS/cm.<br />

Longueur maximale de 15 m avec une conductibilité à partir de 0,5 µS/cm et utilisation de l’appareil<br />

supplémentaire URN 1 (24 V DC).<br />

1. Desserrer les vis j et les retirer, enlever le couvercle l. Fig. <strong>12</strong><br />

2. Desserrer les écrous de raccord-union de l’entrée de câble k et dévisser.<br />

3. Desserrer l’écrou m avec une clé plate de 18. Ne pas dévisser ! Fig. 13<br />

La tête d’électrode peut être pivotée de +/– 180°.<br />

4. Tourner la tête d’électrode dans la direction souhaitée (+/– 180°).<br />

5. Serrer légèrement l’écrou m.<br />

6. Retirer le bornier o de la carte.<br />

7. Affecter le bornier conformément au schéma de raccordement.<br />

8. Enficher le bornier.<br />

9. Placer le couvercle l et le monter avec les vis j.<br />

<strong>19</strong>


Raccordement électrique suite<br />

Schéma de raccordement<br />

L N<br />

Chaîne de sécurité<br />

Fig. 18<br />

Fig. <strong>19</strong><br />

L N<br />

Chaîne de sécurité<br />

Fig. 20<br />

Ce schéma de raccordement ne concerne que la France !<br />

20


Raccordement électrique suite<br />

Tableau des tensions<br />

A l’aide du tableau des tensions, vous pouvez contrôler si l’électrode de niveau est immergée ou s’il y a<br />

un défaut. Veuillez tenir compte du schéma de raccordement NRS 1-8. Fig. 18, Fig. 20<br />

U 1-2<br />

U 1-2<br />

10 µS/cm 0,5 µS/cm<br />

2 V eff<br />

C = 0,3 cm -1<br />

10 V eff<br />

C = 0,13 cm -1<br />

Remarque<br />

n L’autotest de l’amplificateur de commutation NRS 1-8 réduit U 1-2 à 0 V toutes les 40<br />

secondes !<br />

Outils<br />

n Tournevis cruciforme, taille 1<br />

n Tournevis à fente, taille 2,5, entièrement isolé suivant DIN VDE 0680-1<br />

n Clé plate de 18 (<strong>19</strong>)<br />

Mise en service<br />

Contrôler le raccordement électrique<br />

Contrôler si la <strong>NRG</strong> 1...-<strong>12</strong> est câblée avec l’appareil de commande NRS 1-8 conformément au schéma<br />

de raccordement. Fig. 18, Fig. 20<br />

Etablir l’alimentation électrique<br />

Etablir l’alimentation électrique de l’indicateur de niveau NRS 1-8.<br />

21


Service<br />

Sécurité de niveau d’eau élevé<br />

Utilisation avec l’appareil de commande NRS 1-8 dans les installations à eau surchauffée et à vapeur<br />

suivant TRD 401, TRD 602, TRD 604, EN <strong>12</strong>952, EN <strong>12</strong>953 ou suivant les directives nationales.<br />

Remarque<br />

n Les dysfonctionnements à la mise en service peuvent être analysés et éliminés à l’aide<br />

du chapitre « Dysfonctionnements en service » de la page 22 !<br />

Dysfonctionnements en service<br />

Liste de contrôle des défauts pour dysfonctionnements en service<br />

Electrode de niveau pas immergée – Alarme niveau haut<br />

Défaut 027 : L’isolation interne de la tige d’électrode est endommagée.<br />

Remède : Remplacer l’électrode de niveau.<br />

Défaut 029 : Absence d’alimentation électrique pour l’appareil de commande.<br />

Remède : Etablir l’alimentation électrique. Câbler les appareils conformément au<br />

schéma de raccordement.<br />

Défaut 033 : Les tiges d’électrode sont en contact avec la masse.<br />

Remède : Contrôler et modifier la position de montage.<br />

Niveau haut atteint – Aucune fonction<br />

Défaut 0<strong>19</strong> : L’orifice d’équilibrage dans le tube de protection manque, est obstrué ou noyé.<br />

Remède : Contrôler le tube de protection et le pourvoir d’un orifice d’équilibrage.<br />

Défaut 020 : Les robinets d’arrêt de la bouteille de mesure située à l’extérieur sont fermés.<br />

Remède : Ouvrir les robinets d’arrêt.<br />

Défaut 022 : Le corps de l’électrode n’est pas relié à la masse sur la bouteille.<br />

Remède : Nettoyer les surfaces d’étanchéité et les pourvoir d’un joint métallique<br />

conformément au dessin.<br />

Ne pas étanchéifier l’électrode avec du chanvre ou une bande en téflon !<br />

Si des défaillances ou des défauts apparaissent qui ne peuvent être éliminés avec ces instructions de<br />

montage et de mise en service, veuillez vous adresser à notre service technique.<br />

22


Mise hors service<br />

Danger<br />

De graves brûlures sont possibles sur tout le corps !<br />

Avant de démonter l’électrode de niveau, le réservoir ou la bouteille de mesure doit<br />

être hors pression (0 bar) et à température ambiante (20 °C) !<br />

Elimination<br />

Démonter l’appareil et trier les déchets suivant les matières indiquées.<br />

Pour éliminer l’appareil, il convient de respecter les prescriptions légales en matière d'élimination des<br />

déchets.<br />

23


GESTRA<br />

Vous trouverez nos filiales dans le monde entier sous :<br />

www.gestra.de<br />

España<br />

GESTRA ESPAÑOLA S.A.<br />

Luis Cabrera, 86-88<br />

E-28002 Madrid<br />

Tel. 0034 91 / 5 15 20 32<br />

Fax 0034 91 / 4 13 67 47; 5 15 20 36<br />

E-mail : aromero@flowserve.com<br />

Great Britain<br />

Flowserve GB Limited<br />

Abex Road<br />

Newbury, Berkshire RG14 5EY<br />

Tel. 0044 <strong>16</strong> 35 / 46 99 90<br />

Fax 0044 <strong>16</strong> 35 / 3 60 34<br />

E-mail : gestraukinfo@flowserve.com<br />

Polska<br />

GESTRA Polonia Spolka z.o.o.<br />

Ul. Schuberta 104<br />

PL - 80-<strong>17</strong>2 Gdansk<br />

Tel. 0048 58 / 3 06 10 - 02<br />

0048 58 / 3 06 10 - 10<br />

Fax 0048 58 / 3 06 33 00<br />

E-mail : gestra@gestra.pl<br />

Portugal<br />

Flowserve Portuguesa, Lda.<br />

Av. Dr. Antunes Guimarães, 1159<br />

Porto 4100-082<br />

Tel. 00351 22 / 6 <strong>19</strong> 87 70<br />

Fax 00351 22 / 6 10 75 75<br />

E-mail : jtavares@flowserve.com<br />

Italia<br />

Flowserve S.p.A.<br />

Flow Control Division<br />

Via Prealpi, 30<br />

l-20032 Cormano (MI)<br />

Tel. 0039 02 / 66 32 51<br />

Fax 0039 02 / 66 32 55 60<br />

E-mail : infoitaly@flowserve.com<br />

USA<br />

Flowserve GESTRA U.S.<br />

2341 Ampere Drive<br />

Louisville, KY 40299<br />

Tel. 001 502 / 267-2205<br />

Fax 001 502 / 266-5397<br />

E-mail : FCD-Gestra-USA@flowserve.com<br />

GESTRA <strong>AG</strong><br />

Postfach 10 54 60, D-28054 Bremen<br />

Münchener Str. 77, D-28215 Bremen<br />

Téléphone 0049 (0) 421 / 35 03 - 0<br />

Fax 0049 (0) 421 / 35 03 - 393<br />

E-Mail gestra.ag@flowserve.com<br />

Internet www.gestra.de<br />

818893-00/309cm · 2003 GESTRA <strong>AG</strong> · Bremen · Printed in Germany<br />

24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!