7. Operation in explosive areas<br />

The explosion-proof encoder 7014SIL complies with the design requirements of Equipment Group II,<br />

Category 2G (Ex atmosphere Gas) and 2D (Ex atmosphere Dust).<br />

Compliance with the directives according to 94/9/EC CE marking:<br />

Explosion protection:<br />

EC Type Examination<br />

Category (Gas)<br />

Category (Dust)<br />

PTB09 ATEX 1106X<br />

II 2G Ex d II C T6<br />

II 2D Ex tD A21 IP6X T85ºC<br />

Directive 94/9/EC EN 60079-0:2006; DIN EN 60079-1:2007<br />

EN 61241-0:2006; DIN EN 61241-1:2004<br />

Use in other explosive areas is not allowed.<br />

The installation and assembly of electrical devices may be carried out exclusively by a qualified electrician!<br />

Repair work and mounting of spare parts or attachments may be carried out exclusively by<br />

the Kübler Company.<br />

The devices may be operated only within the limit values as they are stated in the technical data.<br />

The maximum operating voltages must not be exceeded!<br />

english<br />

The encoders of the 7014SIL model series have been designed, developed and manufactured in<br />

compliance with the relevant safety requirements of the following industrial standards:<br />

Protection class: DIN EN 60529 IP6X: 2000<br />

Climate testing: DIN EN 60068-2-3: 1986<br />

Emission of interferences: DIN EN 61000-6-3 and DIN EN 61000-6-4: 2003<br />

Shock resistance: DIN EN 60068-2-27: 1995<br />

Vibration resistance: DIN EN 60068-2-6: 1996<br />

Manufactured according to: DIN EN 61010-1 protection class III: 2002<br />

To prevent dangerous structure-borne currents, the encoders must be operated with safety extra-low<br />

voltages (SELV) and be located in an area with equipotential bonding.<br />

Use an external fuse for protection (see the electrical data).<br />

Fields of application: industrial processes and controls.<br />

Over-voltages at the terminals of the device must be kept within the limits of overvoltage category II.<br />

Avoid shocks to the housing – especially to the encoder shaft – and axial and radial overload to the<br />

encoder shaft. Maximum accuracy and durability of the encoders are only granted when using à suitable<br />

coupling.<br />

The high-level EMC characteristics are only valid in connection with cables and connectors supplied<br />

as a standard. When using shielded cables, the shield must be connected to gro<strong>und</strong> over a large<br />

area. Also the voltage supply cables should be entirely shielded. If this is not possible, appropriate filtering<br />

measures must be taken. The installation environment and the wiring have a significant influence<br />

on the EMC of the encoder. Therefore, the installer must secure the EMC of the whole plant<br />

(device).<br />

Voltage peaks on the supply cable are to be limited to max. 1000 V by the upstream power supply. In<br />

electrostatically critical areas, a good ESD protection is to be provided during installation work for the<br />

connectors and the cable to be connected.<br />

The connection cable is suitable only for fixed installation (no mobile operation). The choice of the<br />

cable, in compliance with the Ex regulations, is the responsibility of the plant builder. The flameproof<br />

encoder housing may in no case be opened.<br />

The encoders of the 7014SIL model series are manufactured in compliance with Directive 94/9/EC.<br />

The product is intended exclusively for integration in or mounting on suitable plants.<br />

7