15. Technical specifications<br />

Control unit<br />

• Mains connection fuse 10 A slow-blow; fault current circuit breaker 30 mA<br />

• Device-internal glass tube microfuse 5x20mm 3.15AT only for the inputs and outputs<br />

(The electronic system has an independent power supply and battery buffer)<br />

• Mains voltage / mains frequency 230 VAC / 50 Hz<br />

• Control unit with 1.4 m mains power supply cable and angled earthed connector<br />

• Mains current standby (ready for operation) 17 mA (display background lighting is switched off).<br />

• Mains current in operation 0.8 A to 1.4 A (depending on compressor size)<br />

• Working temperature 0°C to + 40°C<br />

• Type of protection IP 42 (IP44 when compressor is plugged in)<br />

• Protection class 1<br />

• Switching capacity of the relay outputs 230 V AC, 16 A, cos phi = 1<br />

• Switching capacity of the floating contact (changeover contact) 230 Vac, 5 A ; 42 VDC 0.5 A<br />

• Connection for serial interface COM1 via 5-pole connector (optional)<br />

• Connection for second floating switch 230 VAC via 3 terminals (optional)<br />

• Connection for remote signal generator 20 m line 2 x 0.75 qmm (<strong>KESSEL</strong>-No. 20162) (optional)<br />

• Connection for compressor via earthed coupling<br />

• Connection for valve block via Amphenol socket 6 + PE<br />

• Dimensions [mm] = 180 x 200 x 65<br />

• Weight control unit 1.2 kg (without packaging)<br />

Compressor<br />

Diaphragm compressor model EL 100<br />

Mains voltage / mains frequency 230 VAC - 50 Hz<br />

Connection to control unit via 1 m mains power supply<br />

cable with straight earthed connector<br />

Performance P = 120 W at 200 mbar<br />

Protection class 1<br />

Type of protection IP 44<br />

Q = 93 l/min at 200 mbar<br />

Working temperature 0° C up to + 40° C<br />

Dimensions [mm] = 270 x 200 x 220<br />

Hose connection d = 19 mm<br />

Weight = 8.5 kg<br />

Valve block with floating switch<br />

Mains voltage / mains frequency 230 VAC - 50 Hz<br />

Connection on the control unit via 15 m connecting line<br />

with Amphenol connector 6 + PE<br />

Performance P = 7W<br />

Protection class 1<br />

Type of protection IP 68<br />

Working temperature 0° C up to + 40° C<br />

Dimensions [mm] = 200 x 140 x 140<br />

Hose connections da = 25 mm & da = 20 mm<br />

Weight: 3,5 kg<br />

Diaphragm compressor model EL 150<br />

Mains voltage / mains frequency 230 VAC - 50 Hz<br />

Connection to control unit via 1 m mains power supply<br />

cable with straight earthed connector<br />

Performance P = 170 W at 200 mbar<br />

Protection class 1<br />

Type of protection IP 44<br />

Q = 205 l/min at 200 mbar<br />

Working temperature 0° C up to + 40° C<br />

Dimensions[mm] = 360 x 270 x 230<br />

Hose connection da = 27 mm<br />

Weight = 16 kg<br />

127