9. Malfunctions and remedial measure faults<br />

Faults Causes Elimination<br />

- Solenoid valve defective.<br />

- A backup occurs at the point of<br />

discharge. The water conveyed<br />

with the clear water syphon flows<br />

back again.<br />

- If during the manual operation of<br />

the clear water extraction no distinct<br />

opening noise can be<br />

heard, please call the after-sales<br />

service. The point of discharge<br />

must be cleared again.<br />

The clearing capacity of the facility<br />

is disappointing<br />

Most of the above-mentioned faults<br />

can lead to a reduction of the purification<br />

performance. In addition,<br />

there may be all kinds of reasons for<br />

inadequate drain values such as insufficient<br />

entry of air.<br />

- Discharge of larger amounts of<br />

detergents or disinfectants or<br />

other forbidden substances<br />

(paints, solvents, etc.) into the<br />

plant.<br />

- Sludge disposal not performed.<br />

- Faulty settings for the population<br />

values.<br />

- Plant has been separated from the<br />

power grid for a longer period of<br />

time.<br />

- In the interest of the environment,<br />

you should contact your aftersales<br />

service to achieve an improvement<br />

of the drain values.<br />