8. Control of the septic system<br />

8.3.3 Maintenance deadline<br />

Input of the next maintenance deadline by the maintenance<br />

partner.<br />

8.4 Setting menu<br />

Systeminfo<br />

Informationen<br />

Maintenance<br />

Wartung<br />

Positions Einstellungen<br />

Parameter<br />

Parameterspeicher storage<br />

Date/time Datum / Uhrzeit<br />

Float Schwimmer<br />

Pressure Drucksensor<br />

HW Modul<br />

UW Modul<br />

Pressure Drucküberwachung<br />

monitor<br />

Communication<br />

Kommunikation<br />

Classes Klassen<br />

Nominal Nenngrößen size<br />

Language Sprache<br />

Reset<br />

Electricity Stromüberwachung control<br />

8.4.1 Parameters<br />

Change of parameters stored at the factory.<br />

Note: Every change is immediately accepted when<br />

the OK key is pressed. In addition, on quitting this<br />

menu it is possible to save these values in the parameter<br />

memory (see point 8.4.2) under a separate<br />

name.<br />

8.4.2 Parameter memory<br />

Loading of the values accepted on initialisation and<br />

of the values added under a new name (see 8.4.1).<br />

8.4.3 Date / time<br />

Setting the current date and time.<br />

8.4.4 Floater<br />

Switching the two floaters on and off (second floater<br />

is an optional accessory). The status is displayed in<br />

the system information menu.<br />

8.4.5 Pressure sensor<br />

Activation / deactivation of the pressure sensor. Deactivation<br />

deactivates the high water and low water<br />

module and the pressure monitoring system.<br />

8.4.6 High water module<br />

Switching on and off the high water alarm. The height<br />

for the alarm signal preset at the factory is 150 cm.<br />

8.4.7 Low water module Switching on and off the low water alarm. The height for the alarm signal preset at the<br />

factory is 80 cm.<br />

8.4.8 Pressure monitoring Continuous pressure measurement (monitoring) of the <strong>INNO</strong>-<strong>CLEAN®</strong> system. The<br />

preset values should not be changed. The pressure monitoring system is deactivated<br />

by deactivating the pressure sensor (see 8.4.5)<br />

8.4.9 Communication Input / change of the station name, the device number, the modem type, the PINS and<br />

the number of the mobile phone to which possible malfunctions can be sent via SMS<br />

(for a detailed description see separate operating instructions).<br />

8.4.10 Classes Display / change of purification class.<br />

8.4.11 Nominal sizes Display / change of nominal size.<br />

8.4.12 Language Display / change of language<br />

8.4.13 Reset Resetting the control unit to the factory setting (operating hours are not reset).<br />

8.4.14 Current monitoring Continuous current measurement (monitoring) of the <strong>INNO</strong>-CLEAN ® system. The preset<br />

values should not be changed. Current monitoring is deactivated by setting the bottom<br />

current limit to 0.0 A.<br />

118