7. Maintenance<br />

7.2 Compressor maintenance<br />

Caution: Before the start of any maintenance work, the<br />

mains plug must be unplugged.<br />

Note: Please note the details in the compressor operations<br />

diary<br />

Filter cleaning every three months<br />

1. Unscrew the attachment screw on the filter lid.<br />

2. Detach/undo the filter lid.<br />

3. Remove the filter. Release any dust by knocking the filter<br />

against something. If it is heavily soiled, clean the filter<br />

with a neutral detergent, afterwards rinse with water and<br />

allow to dry in the shade.<br />

4. Refit the cleaned filter such that the finer honeycomb<br />

structure is located on the bottom side! Press the filter lid<br />

back into place by exerting pressure from above as illustrated.<br />

5. Fasten the filter lid with the screw.<br />

Caution! Do not use any solvents to clean the filter, as<br />

this may lead to damage.<br />

In general, the following must be checked:<br />

- Is any air flowing from the air outlet?<br />

- Can any abnormal noises or vibrations be heard?<br />

- Is the compressor's temperature normal or possibly<br />

excessive?<br />

- Does the mains power supply cable exhibit any damage?<br />

7.3 Diagnosis and faults<br />

In case of complaints, please first of all refer to chapter 10<br />

"Malfunctions and Remedial Measures".<br />

If it is nevertheless not possible to eliminate a fault, separate<br />

the plant from the power supply and contact one of our<br />

dealers or after-sales service technicians. When doing so,<br />

communicate details of the components (rating plate) and<br />

faults as detailed as possible.<br />

Warning:<br />

Do not put the plant back into operation before a possible<br />

fault has been eliminated. Do not undertake any further attempts<br />

at repairing the plant yourself! Repairs must be carried<br />

out by qualified personnel. If you have any queries in respect<br />

of service work, please contact one of our dealers or<br />

after-sales service technicians.<br />

Spare parts<br />

Please use exclusively original parts.<br />

Failure to do so may lead to malfunctions or defects on the<br />

compressor.<br />

Observe the separate installation and operating instructions<br />

with regard to maintaining the normal service intervals for the<br />

compressor. You can obtain a spare parts list from the aftersales<br />

service of <strong>KESSEL</strong> GmbH.<br />