4. Installation and assembly<br />

Assembly and connection<br />

The wall bracket must be fastened horizontally on the<br />

wall by means of the two dowels and screws included<br />

in the supply.<br />

<br />

<br />

<br />

<br />

Open the control unit by undoing the four cruciform<br />

head screws on the face side and fasten its rear wall<br />

at the predrilled points of the wall bracket (below the<br />

storage space for the compressor) using the four cruciform<br />

head screws included in the supply. Afterwards<br />

the control unit must be closed again. Caution:<br />

pay attention that the unit is de-energised (see safety<br />

information page 2)<br />

<br />

<br />

<br />

<br />

Place the compressor on the storage space of the<br />

wall bracket into the recesses provided for that purpose.<br />

Please pay attention that the pilot lamp must<br />

face to the front and that the device's electrical<br />

connection must be located on the right hand side of<br />

the device. The compressor's mains plug must be<br />

connected with the earthed connector on the control<br />

unit.<br />

Before the elbow for connecting the compressed air<br />

line to the compressor is connected with the device,<br />

the metal sleeve included in the supply must be pushed<br />

into the long leg of the elbow. Afterwards, the<br />

elbow is mounted on the compressor's connection<br />

and is fastened on the device using the spring terminal.<br />

Open the quick-action coupling by turning the end cap by 60° to the left and push in the long end of the<br />

elbow up to the stop. Close the end cap by turning it to the right.<br />

The transparent hose of the compressed air sensor must be connected with the control unit on the third<br />

socket from the left. To do so, undo the black cap nut and remove the clamping ring inside, then push the<br />

cap nut and the clamping ring onto the transparent hose, afterwards push on the hose. Finally, screw on<br />

black cap nut hand-tight.<br />

To connect the compressed air line from the tank, the grey aeration hose in the cable conduit must be shortened<br />

to the adequate length and fastened on the compressor without bends by means of the quick-action<br />

coupling. Caution: lay the aeration hose loosely, without tension.<br />

The connecting cable from the valve block must be plugged into the appropriate socket on the control unit<br />

and fastened by means of the screw connection.<br />