4. Installation and assembly<br />
Assembly and connection<br />
The wall bracket must be fastened horizontally on the<br />
wall by means of the two dowels and screws included<br />
in the supply.<br />
<br />
<br />
<br />
<br />
Open the control unit by undoing the four cruciform<br />
head screws on the face side and fasten its rear wall<br />
at the predrilled points of the wall bracket (below the<br />
storage space for the compressor) using the four cruciform<br />
head screws included in the supply. Afterwards<br />
the control unit must be closed again. Caution:<br />
pay attention that the unit is de-energised (see safety<br />
information page 2)<br />
<br />
<br />
<br />
<br />
Place the compressor on the storage space of the<br />
wall bracket into the recesses provided for that purpose.<br />
Please pay attention that the pilot lamp must<br />
face to the front and that the device's electrical<br />
connection must be located on the right hand side of<br />
the device. The compressor's mains plug must be<br />
connected with the earthed connector on the control<br />
unit.<br />
Before the elbow for connecting the compressed air<br />
line to the compressor is connected with the device,<br />
the metal sleeve included in the supply must be pushed<br />
into the long leg of the elbow. Afterwards, the<br />
elbow is mounted on the compressor's connection<br />
and is fastened on the device using the spring terminal.<br />
Open the quick-action coupling by turning the end cap by 60° to the left and push in the long end of the<br />
elbow up to the stop. Close the end cap by turning it to the right.<br />
The transparent hose of the compressed air sensor must be connected with the control unit on the third<br />
socket from the left. To do so, undo the black cap nut and remove the clamping ring inside, then push the<br />
cap nut and the clamping ring onto the transparent hose, afterwards push on the hose. Finally, screw on<br />
black cap nut hand-tight.<br />
To connect the compressed air line from the tank, the grey aeration hose in the cable conduit must be shortened<br />
to the adequate length and fastened on the compressor without bends by means of the quick-action<br />
coupling. Caution: lay the aeration hose loosely, without tension.<br />
The connecting cable from the valve block must be plugged into the appropriate socket on the control unit<br />
and fastened by means of the screw connection.<br />
106