4. Installation and assembly<br />
<br />
<br />
Mains connection<br />
<br />
<br />
Compressor<br />
Wall bracket<br />
<br />
<br />
<br />
Control unit<br />
Mains connection compressor<br />
<br />
<br />
<br />
Connecting socket for floating contact<br />
Connection valve block (incl. floating switch)<br />
Connection external signal generator<br />
Compressed air connection valve block<br />
<br />
Connection compressed air sensor<br />
<br />
Elbow for connection compressed air hose<br />
Quick-action coupling<br />
4. 11 Installation control unit and compressor<br />
Please note that an empty conduit (DN 100) must be laid to<br />
accommodate the connecting lines between tank and control<br />
unit (see 4.7).<br />
General notes<br />
CAUTION: <strong>KESSEL</strong> recommends to commission a specialist<br />
electrical firm to execute the electrical connections.<br />
Only put the plant into operation after it has been<br />
completely assembled. The plant may not be connected<br />
to the mains while connection work is ongoing.<br />
Control unit and compressor must be assembled in a frostprotected,<br />
flood-proof and dry room. Pay attention to a<br />
backwater-protected assembly!<br />
Pay attention that the room in which the compressor will be<br />
installed is well-ventilated. An adequate air circulation must<br />
be ensured, in particular for equipment that is to be accommodated<br />
inside an external control cabinet so as to protect<br />
the compressor against overheating.<br />
A cool ambient temperature ensures a long service life for<br />
diaphragms and valves.<br />
The compressor should not be operated in a dusty environment.<br />
Overheating caused by clogged filters shortens the<br />
service life of diaphragms and filters.<br />
The compressor is to be protected against direct solar radiation,<br />
snow and frost. The aspirated ambient air must be<br />
free of flammable or aggressive gases or fumes.<br />
The hose line must be laid as short and as straight as possible<br />
between control unit and tank. Changes in direction<br />
must be implemented via long curves instead of narrow<br />
bends.<br />
The compressor must be placed upstream of the control unit<br />
on a suitable pedestal or bracket to avoid any possible damage.<br />
Assembly on an instable basis may give rise to bothersome<br />
noises due to vibrations.<br />
The compressor must be assembled horizontally to prevent<br />
a one-sided load on the diaphragms and thus a shortened<br />
service life of the components.<br />
The compressor should fully rest on all 4 rubber feet and may<br />
not wobble.<br />
105