4. Installation and assembly<br />

The sealing lips could point downwards on<br />

the inside of the ring.<br />

Grease the bottom part of the telescopic <strong>KESSEL</strong> attachment<br />

piece with lubricant and place into the tank opening,<br />

bring into the desired position and fasten by means of a<br />

clamping ring. Alternatively, it is also possible to apply lubricant<br />

to the sealing ring. With the aid of the existing clamping<br />

ring it is now possible to fasten the attachment piece in the<br />

desired position (alignment with the top ground surface). The<br />

fine adjustment to the final height is then effected with the<br />

adjusting screws. A ground slope can be compensated for<br />

with the continuously height-adjustable and up to 5° inclinable<br />

attachment piece. The "Innofant" labels included in the<br />

supply must be attached to the cleaned and dry surface on<br />

the attachment piece (see illustration).<br />

Important: The green "Innofant" must be placed on the inlet<br />

side and the red one on the drain side!<br />

The attachment piece must afterwards be sufficiently backfilled<br />

and compacted.<br />

Inlet<br />

➔<br />

➔<br />

Outlet<br />

4.10 Concluding filling of the tank.<br />

Before starting to backfill, check once again the inlet and drain line as well as the ventilation line and the cable conduit.<br />

Align the attachment piece with the top ground surface.<br />