4. Installation and assembly<br />
cable conduit between valve block and control unit (see-<br />
Procedure)<br />
Air hose to the compressor<br />
Concrete sealing<br />
Cable conduit<br />
seal Item No.<br />
97 711<br />
Basement<br />
wall<br />
KG-pipe DN 100<br />
Seal item<br />
No. 860 116<br />
Seal for pipe duct<br />
Quick-action coupling<br />
Valve block<br />
Locking bracket<br />
Ventil Valve<br />
Inno-Clean<br />
Wall duct customary<br />
in trade e.g.<br />
by Steelter or<br />
DOYMA DN 100<br />
Gradient at least<br />
2° sloping towards<br />
the tank<br />
Tank wall<br />
<strong>INNO</strong>-<strong>CLEAN®</strong><br />
Adapter plate<br />
Lug to hook<br />
in the control line<br />
Changes in direction should be carried out by means of curved<br />
fittings with a maximum bend of 30°.<br />
Caution: Up to their final connection, all pipes should be<br />
temporarily sealed with adhesive tape to prevent the ingress<br />
of dirt while the pipes are pushed through.<br />
Remark:<br />
The tanks may be drilled open in the area of the domes to<br />
produce additional connecting and ventilation lines. For this,<br />
original drill bits and pipe duct seals by <strong>KESSEL</strong> must be<br />
used (<strong>KESSEL</strong> drill bits DN 50 - DN 150, item No. 50100,<br />
<strong>KESSEL</strong> pipe duct seals:<br />
DN 50 item No. 850114<br />
DN 70 item No. 850116<br />
DN 100 item No. 850117<br />
DN 125 item No. 850118<br />
DN 150 item No. 850119<br />
Drilling should be carried out on surfaces that are as plane<br />
as possible.<br />
To provide an optimum seal for the drilled hole, the clearance<br />
between the edge of the drilled hole and uneven contour<br />
should amount to at least 15 mm so that the seal circumferentially<br />
butts evenly against the drill hole.<br />
Control line<br />
Air hoses to the compressed air syphons<br />
Procedure:<br />
- Open the locking bracket on the valve block inside the tank<br />
- Remove the valve block from the adapter plate<br />
- Pull the grey ventilation hose and control line through the<br />
cable conduit<br />
- Connect the ventilation hose on the valve block using a<br />
quick-action coupling (see 4.11 Point 5)<br />
- Insert valve block on adapter plate<br />
- Caution: Control line must be clipped into the lug provided<br />
for that purpose (see illustration) to ensure a correct locking<br />
with the adapter plate.<br />
- Check valve block for correct seat and close the locking<br />
lever<br />
4.9 Assembly of the attachment pieces<br />
First of all, place the seal (see drawing 4.9) into the bead provided<br />
inside the dome.<br />
Telescopic attachment piece<br />
• Ventilation<br />
Plants with closed cover are aerated and ventilated via the<br />
penstock of the drainage plant. An additional ventilation line<br />
in DN 100 can be connected to the dome. For this purpose,<br />
the appropriate drill bit and pipe duct seal by <strong>KESSEL</strong> must<br />
be used (see illustration page 5). <strong>KESSEL</strong> recommends the<br />
use of an activated carbon filter to avoid any unpleasant<br />
odours.<br />
4.8 Laying the connecting lines to the control unit<br />
(ventilation hose and control line)<br />
The control line and the ventilation hose must be laid in the<br />
Lip seal DN 600<br />
Clamping ring<br />
Tank dome<br />
Minimum insertion<br />
depth 100 mm<br />
103