28.10.2013 Views

3707 - 3707/10 3907 - 3907W - 3907/18 - Nilfisk PARTS

3707 - 3707/10 3907 - 3907W - 3907/18 - Nilfisk PARTS

3707 - 3707/10 3907 - 3907W - 3907/18 - Nilfisk PARTS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mod. <strong>3707</strong> - <strong>3707</strong>/<strong>10</strong> - <strong>3907</strong> - <strong>3907</strong>W - <strong>3907</strong>/<strong>18</strong><br />

9 Troubleshooting<br />

Fault Causes<br />

1- The vacuum suddenly stops<br />

2- The efficiency of the vacuum<br />

has dropped<br />

3- Dust leaks from the vacuum<br />

silencer<br />

4- The vacuum blows instead<br />

of sucking<br />

5- Electrostatic current on the<br />

vacuum<br />

1- Thermic protection tripped<br />

(red warning light)<br />

2- Clogged primary filter<br />

2- Clogged suction pipe<br />

3- The filter is torn<br />

3- Inadequate filter<br />

4- Incorrect connection to the<br />

electricity main<br />

5- Non existent or inefficient<br />

earthing<br />

-88-<br />

© C.F.M. S.p.A.<br />

Tutti i diritti riservati / All rights reserved<br />

Tous droits réservés / Alle Rechte vorbehalten<br />

Remedies<br />

1- Check the setting of the<br />

thermic protector<br />

Check the motor power<br />

draw. Contact an authorized<br />

after-sales center if<br />

necessary<br />

1- Reset the thermic<br />

protector<br />

2- Shake the filter. Replace<br />

it if this is not sufficient<br />

2- Check the suction pipe<br />

and clean it<br />

3- Change it for another of<br />

identical category<br />

3- Change it for another of<br />

suitable category and<br />

check<br />

4- Modify the phase inverter<br />

5- Check all earth connections.<br />

Particularly<br />

check the suction inlet<br />

fitting<br />

Lastly, the pipe must be<br />

strictly antistatic