20<br />
troubleshooting<br />
PROBLEM CAuSE SOLuTION<br />
The pump<br />
is noisy<br />
The pump<br />
does not start<br />
Should you fail to eliminate the cause of the malfunction, refer to the nearest Service Center.<br />
unlocKing ProceDure<br />
• A red light in the LED indicates a locking.<br />
• Turn the selector to the position MAX to start the automatic release process – the<br />
warning light (LED) blinks.<br />
• Reiterate previous operation several times.<br />
• If the locking is not removed through the automatic release process (the warning<br />
light returns to be red), it is necessary to perform the manual proceeding described<br />
in the next steps.<br />
• Disconnect power supply - the warning light switches off.<br />
• Close the interception organs upstream and downstream of the pump and let it<br />
cool. Disassemble the motor and clean the impeller.<br />
• Set the selector on the wished position.<br />
• Connect power supply<br />
• If the pump doesn’t run see troubleshooting chart.<br />
5. SPare PartS<br />
Suction pressure is insufficient<br />
- cavitation<br />
Increase the static pressure<br />
of the system<br />
Loud noises of water circulation Reduce the rotation speed<br />
Presence of foreign bodies<br />
in the impeller<br />
Lack of power supply<br />
(the warning light is off)<br />
Presence of foreign bodies in<br />
the impeller (the warning light is red)<br />
Disassemble the motor and<br />
clean the impeller<br />
Verify voltage value of the<br />
electric plant<br />
Verify the connection of the motor<br />
Verify the fuses of the plant<br />
Disassemble the motor and clean the<br />
impeller if the unlocKing<br />
ProceDure (see below) doesn’t<br />
succeed<br />
With high fluid temperatures and pressures there is the risk of burnings.<br />
hazard of scalding by simple contact.<br />
Should you need to order any spare parts, always provide all rating data of the pump.<br />