20<br />

troubleshooting<br />

PROBLEM CAuSE SOLuTION<br />

The pump<br />

is noisy<br />

The pump<br />

does not start<br />

Should you fail to eliminate the cause of the malfunction, refer to the nearest Service Center.<br />

unlocKing ProceDure<br />

• A red light in the LED indicates a locking.<br />

• Turn the selector to the position MAX to start the automatic release process – the<br />

warning light (LED) blinks.<br />

• Reiterate previous operation several times.<br />

• If the locking is not removed through the automatic release process (the warning<br />

light returns to be red), it is necessary to perform the manual proceeding described<br />

in the next steps.<br />

• Disconnect power supply - the warning light switches off.<br />

• Close the interception organs upstream and downstream of the pump and let it<br />

cool. Disassemble the motor and clean the impeller.<br />

• Set the selector on the wished position.<br />

• Connect power supply<br />

• If the pump doesn’t run see troubleshooting chart.<br />

5. SPare PartS<br />

Suction pressure is insufficient<br />

- cavitation<br />

Increase the static pressure<br />

of the system<br />

Loud noises of water circulation Reduce the rotation speed<br />

Presence of foreign bodies<br />

in the impeller<br />

Lack of power supply<br />

(the warning light is off)<br />

Presence of foreign bodies in<br />

the impeller (the warning light is red)<br />

Disassemble the motor and<br />

clean the impeller<br />

Verify voltage value of the<br />

electric plant<br />

Verify the connection of the motor<br />

Verify the fuses of the plant<br />

Disassemble the motor and clean the<br />

impeller if the unlocKing<br />

ProceDure (see below) doesn’t<br />

succeed<br />

With high fluid temperatures and pressures there is the risk of burnings.<br />

hazard of scalding by simple contact.<br />

Should you need to order any spare parts, always provide all rating data of the pump.<br />

reserved right of modification.