18<br />

The warning light (LED), if lighted, indicates that the power supply is present.<br />

3.3 Start<br />

CAuTION!<br />

Absolutely avoid dry operation. Start the pump only after having<br />

completely filled the plant.<br />

The pump can be noisy at start due to the presence of air. Such noise should stop<br />

after few minutes of operation. usually air is drained from the pump after short<br />

time.<br />

CAuTION!<br />

Do not touch the fluid or the pump when the temperature is greater<br />

than 60 °C. hazard of scalding by simple contact.<br />

the plant cannot be drained by using the pump.<br />

Settings concerning pump performance<br />

With the help of the selector potentiometer (fig. M), set the performance of the<br />

pump (head) according to the needs.<br />

The selector is set by the manufacturer on the position marked by a dot and<br />

the letter R. This setting is suitable for 80% of all one-family houses. Should this<br />

performance be insufficient, progressively increase the set value. Should this<br />

performance be excessive or should noise arise due to the speed of the pumped<br />

fluid, progressively reduce the calibration.<br />

Modify the performance of the pump (head) by rotating the selector potentiometer<br />

using a flat screwdriver, as given in the following table:<br />

adjustment Performance<br />

factory Setting<br />

Proportional pressure control<br />

The performance of the pump are suitable for most of heating<br />

plants in domestic buildings (approximately 80% of systems).<br />

The pump head is reduced at falling water demand and increased<br />

at rising water demand.<br />

The warning light (LED) is green.