16 Installation and Service Instructions J1 Figure 4 Location of jumper J3 on PCB R16 C16 R14 C15 + D6 C19 U3 C14 R13 L2 C17 L3 J3 + CX1 2005416A 2005416A-01 + STEADY FLASH CR1 F1 VR1 R12 D5 C9 Cleaning the Fixture C8 R11 Q1 R10 C10 J2 1 J3 JUMPER LOCATION U2 C11 R15 R9 SPADE + Model 191XL Series LED Beacon C13 C4 + CY1 T1 D1 HS2 R1 C1 R3 D2 D7 D3 C2 C12 U1 C7 OPTO R6 (120-240 VAC MODEL SHOWN) 290A6286B EXPLOSION HAZARD—Never use an abrasive material or file to remove corrosive materials from threaded surfaces. In extremely corrosive locations, equipment should be periodically inspected to guard against unusual deterioration and possible porosity, since this may weaken the enclosure structurally. Maintenance procedures sometimes require fixtures to be hosed down for good housekeeping. The circuit should be turned off prior to hosing down the fixture. The fixture should be cleaned periodically to maintain maximum light output. Only mild, non-abrasive cleaning agents should be used. The glass dome should be regularly inspected for scratches and chips, and if damaged, MUST be replaced. HS1 C18 + D4 + R5 - o
Installation and Service Instructions Lubricating the Threaded Joint The threaded joint on the cover should be kept well lubricated with a corrosion inhibiting grease such a petrolatum or soapthickened mineral oil. If corrosive materials have accumulated on the threaded joints and cannot be removed with solvents, the parts should be discarded and replaced. Ordering Replacement Parts EXPLOSION HAZARD—Substitution of components may impair suitability for Class I, Division 2. Typical spare parts are listed Table 4. Due to certification, certain component parts are not available for field replacement. Units with this type of damage must be either replaced entirely or returned to Federal Signal for service. To order replacement parts, please call Federal Signal Customer Support at 708-534-4756 or 877-289- 3246. Table 4 Replacement parts Description Part Number Dome Assy., Amber K8449078-01 Dome Assy., Blue K8449078-06 Dome Assy., Clear K8449078-04 Dome Assy., Green K8449078-07 Dome Assy., Red K8449078 Gasket K8449080 Grease, 8 oz Tube KR81-05-01 Dome Guard K8449090 LED Emitter, Amber K14700030-A LED Emitter, Blue K14700030-B LED Emitter, Green K14700030-G LED Emitter, Red K14700030-R LED Emitter, White K14700030-W Model 191XL Series LED Beacon 17
- Page 1 and 2: 2561421G REV. G 513 Printed in U.S.
- Page 3 and 4: Contents Safety Messages to Install
- Page 5 and 6: Safety Messages to Installers Insta
- Page 7 and 8: Installation and Service Instructio
- Page 9 and 10: Installation and Service Instructio
- Page 11 and 12: Wiring the Beacon Installation and
- Page 13 and 14: Installation and Service Instructio
- Page 15: Installation and Service Instructio
- Page 19 and 20: © 2013 Federal Signal Corporation.
- Page 21 and 22: 2561421G REV. G 513 Imprimé aux É
- Page 23 and 24: Contenu Messages de sécurité dest
- Page 25 and 26: Instructions d’installation et d
- Page 27 and 28: Instructions d’installation et d
- Page 29 and 30: Instructions d’installation et d
- Page 31 and 32: Câblage de la lumière AVERTISSEME
- Page 33 and 34: Instructions d’installation et d
- Page 35 and 36: Instructions d’installation et d
- Page 37 and 38: Instructions d’installation et d
- Page 39 and 40: Instructions d’installation et d
- Page 41 and 42: 2561421G REV. G 513 Impreso en los
- Page 43 and 44: Contenido Mensajes de seguridad par
- Page 45 and 46: Instrucciones de instalación y man
- Page 47 and 48: Instrucciones de instalación y man
- Page 49 and 50: Instrucciones de instalación y man
- Page 51 and 52: Cableado de la baliza ADVERTENCIA I
- Page 53 and 54: Instrucciones de instalación y man
- Page 55 and 56: EMISOR LED Instrucciones de instala
- Page 57 and 58: Limpieza del artefacto ADVERTENCIA
- Page 59 and 60: Instrucciones de instalación y man
16<br />
<strong>Installation</strong> <strong>and</strong> Service Instructions<br />
J1<br />
Figure 4 Location of jumper J3 on PCB<br />
R16 C16<br />
R14<br />
C15 + D6<br />
C19<br />
U3<br />
C14<br />
R13<br />
L2<br />
C17<br />
L3<br />
J3<br />
+<br />
CX1<br />
2005416A<br />
2005416A-01<br />
+<br />
STEADY<br />
FLASH<br />
CR1<br />
F1<br />
VR1<br />
R12<br />
D5 C9<br />
Cleaning the Fixture<br />
C8<br />
R11<br />
Q1<br />
R10<br />
C10<br />
J2<br />
1<br />
J3 JUMPER LOCATION<br />
U2 C11<br />
R15<br />
R9<br />
SPADE<br />
+<br />
Model 191XL Series LED Beacon<br />
C13<br />
C4<br />
+<br />
CY1<br />
T1<br />
D1<br />
HS2<br />
R1<br />
C1<br />
R3<br />
D2<br />
D7<br />
D3<br />
C2 C12<br />
U1<br />
C7 OPTO<br />
R6<br />
(120-240 VAC MODEL SHOWN) 290A6286B<br />
EXPLOSION HAZARD—Never use an abrasive material or file to<br />
remove corrosive materials from threaded surfaces. In extremely<br />
corrosive locations, equipment should be periodically inspected<br />
to guard against unusual deterioration <strong>and</strong> possible porosity,<br />
since this may weaken the enclosure structurally.<br />
<strong>Maintenance</strong> procedures sometimes require fixtures to be hosed<br />
down for good housekeeping. The circuit should be turned off<br />
prior to hosing down the fixture.<br />
The fixture should be cleaned periodically to maintain maximum<br />
light output. Only mild, non-abrasive cleaning agents should be<br />
used. The glass dome should be regularly inspected for scratches<br />
<strong>and</strong> chips, <strong>and</strong> if damaged, MUST be replaced.<br />
HS1<br />
C18 +<br />
D4<br />
+<br />
R5<br />
-<br />
o