Fault Description of fault Action<br />
code<br />
U1 Descaler, low level Fill descaler<br />
U3 Rinse-aid, low level Fill rinse-aid<br />
U4 Process agent, low level Fill process agent<br />
U6 Inspection request Contact authorised service personnel<br />
U7 Warning of high item Let the items cool down<br />
temperature<br />
U8 External communication<br />
H6 Start attempt with door open Close the door (the machine makes a<br />
new start attempt). Contact authorised<br />
service personnel if the fault persists.<br />
H7 Battery fault Contact authorised service personnel<br />
F1 Faulty temperature sensor Contact authorised service personnel<br />
F2 Level sensor fault, tank Contact authorised service personnel<br />
F3 Level sensor fault, detergent Contact authorised service personnel<br />
F4 Logic error in door, door locked Contact authorised service personnel<br />
but not closed.<br />
F5 Logic error in machine configuration Contact authorised service personnel<br />
F6 Inspection request Contact authorised service personnel<br />
F7 Disinfection temperature not Contact authorised service personnel<br />
reached<br />
F8 Door open/unlocked during Contact authorised service personnel<br />
process<br />
F9 Fault, settings (E2 fault) Contact authorised service personnel<br />
F10 Could not fill/empty tank Contact authorised service personnel<br />
F11 Leakage Contact authorised service personnel<br />
F12 Door cannot be locked Contact authorised service personnel<br />
F14 Operating time, door Contact authorised service personnel<br />
F18 Wrong machine type Contact authorised service personnel<br />
Instruction manual 5014905-00 Rev A Edition 2005-06-25 9