30.07.2013 Views

DE Gebrauchsanleitung / Montageanleitung 2 FR ... - Hansgrohe

DE Gebrauchsanleitung / Montageanleitung 2 FR ... - Hansgrohe

DE Gebrauchsanleitung / Montageanleitung 2 FR ... - Hansgrohe

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Operation (see page 19)<br />

Cleaning<br />

see enclosed brochure<br />

Dimensions (see page 22)<br />

Flow diagram<br />

(see page 22)<br />

Fault Cause Remedy<br />

Insufficient water - Supply pressure inadequate - Check water pressure (If a pump<br />

has been installed check to see if<br />

the pump is working).<br />

- Filters are dirty - Clean filters<br />

Crossflow, hot water being forced<br />

into cold water pipe, or vice versa,<br />

when mixer is closed<br />

Spout temperature does not<br />

correspond with temperature set<br />

English<br />

- Shower filter seal dirty - Clean filter seal between shower<br />

and hose<br />

- Backflow preventers dirty or<br />

leaking<br />

Assembly see page 60<br />

- Clean backflow preventers,<br />

exchange if necessary<br />

- Thermostat has not been adjusted - Adjust thermostat<br />

Temperature regulation not possible - Temperature regulator dirty or<br />

calcified<br />

- For new installations: basic body<br />

incorrectly connected (should be:<br />

cold right, hot left) or installed with<br />

180º rotation<br />

Safety stop button not operating - Spring defective<br />

- Button calcified<br />

Spare parts (see page 21)<br />

Test certificate (see page 22)<br />

- Hot water temperature too low - Increase hot water temperature to<br />

42 ºC to 65 ºC<br />

- Clean temperature regulator,<br />

exchange if necessary<br />

- Install function block turned through<br />

180º<br />

- Clean spring and/or button,<br />

exchange if necessary<br />

7