Instructions for use (English)<br />

<strong>ORALLOY</strong> <strong>MAGICAP</strong> S<br />

Definition<br />

Coltène® <strong>ORALLOY</strong> <strong>MAGICAP</strong> S is distributed in predosed<br />

capsules which contain mercury in the foil bag<br />

and a ternary, microcrystalline, spheroidale alloy powder<br />

for the fabrication of NON-GAMMA-2 amalgams.<br />

Mixing alloy powder with mercury produces a sculptable<br />

paste that sets within a short period of time.<br />

Its effectiveness lies in its ability to durably replace<br />

lost tooth structure and restore masticatory function.<br />

Composition<br />

1 capsule contains: 1 spill 2 spills 3 spills<br />

(green) (blue) (red)<br />

Ag elementary 0.24 g 0.36 g 0.48 g<br />

Sn elementary 0.11 g 0.16 g 0.21 g<br />

Cu elementary 0.05 g 0.08 g 0.11 g<br />

Alloy 0.40 g 0.60g 0.80 g<br />

Hg elementary 0.34 g 0.51 g 0.70 g<br />

Amalgam 0.74 g 1.11g 1.50 g<br />

Mixing ratio: 1 : 0.9 1 : 0.9 1 : 0.9<br />

Field of application<br />

Occlusion-bearing restorations in the posterior area<br />

(class I and II), if no other plastic restorative materials<br />

or techniques may be applied.<br />

Contraindications<br />

Amalgam should not be used:<br />

– In case of allergic reaction to the components of<br />

Coltène® <strong>ORALLOY</strong> Tablets or materials of amalgam<br />

of similar composition.<br />

– No new amalgam restorations should be placed in<br />

patients suffering from severe kidney disfunction.<br />

– For retrograde root canal fillings.<br />

We recommend not to carry out extensive amalgam<br />

therapy (placement and, in particular, removal of<br />

amalgam fillings) during pregnancy.<br />

Small children exhibit increased sensitivity to mercury<br />

and it should be evaluated with utmost care, it amalgam<br />

restorations are necessary.<br />

Side effects<br />

Allergic reactions of type IV and/or electro-chemical<br />

reactions (e.g. taste sensations and irritations of the<br />

mucous membrane) have been researched to occur<br />

only in individual cases.<br />

Electro-chemical processes may provoke the lichen<br />

planus of the oral mucosa.<br />

After the placement or removal of amalgam fillings, a<br />

slight increase of the mercury concentration in the<br />

blood or the urine can be observed for a limited period<br />

of time.<br />

Interactions<br />

Amalgamation and subsequent electro-chemical reaction<br />

may occur when unset silver amalgam or, in<br />

particular, mercury pressed out during condensation<br />

comes into contact with gold or other precious metal<br />

(restorations or dentures).<br />

Contact of the occlusal or any lateral surface with adjacent<br />

crowns, bridges, inlays or fillings made of different<br />

alloys may lead to galvanic effects (caused by<br />

corrosion).<br />

If local missensations (e.g. taste sensations) due to<br />

electro-chemical reactions upon contact of the amalgam<br />

filling with other alloys should occur and continue<br />

for a certain time, the amalgam filling should be<br />

replaced using a different material.<br />

Application<br />

Dosing<br />

The mixing ratio predetermined by the amount of alloy<br />

and mercury contained in the capsules should be<br />

observed. Predosed capsules are available.<br />

Mixing/trituraton<br />

Coltène® <strong>ORALLOY</strong> <strong>MAGICAP</strong> S are self-activating.<br />

This means that the capsules are inserted into an appropriate<br />

mixing device. Before initiating the trituration<br />

process, check the fit of the capsule. The trituration<br />

time has to be set individually for each device<br />

(deviations in time, frequency and amplitude can be<br />

observed even in devices of the same type). The result<br />

of an ideal trituration time is an amalgam bead with a<br />

silvery gloss which comes off the capsule cleanly. Too<br />

long trituration times result in sticky amalgam (especially<br />

on the foil of the mercury pillow) and reduced<br />

working time. Too short trituration may lead to a dull<br />

appearance and insufficiently mixed material.<br />

Trituration time for the predosed capsules<br />

Coltène® <strong>ORALLOY</strong> <strong>MAGICAP</strong> S in seconds.<br />

Instrument Speed 1 Port. 2 Port. 3 Port.<br />

Capmix fixed 5 – 7 5 – 7 5 – 7<br />

Silamat fixed 5 – 7 5 – 7 5 – 7<br />

Silamat Plus Programm P2 5 – 7 5 – 7 5 – 7<br />

(slow) (fast) (slow)<br />

Vari-Mix Mll M2 8 – 12 8 – 12 8 – 12<br />

Dentomat 4’000 – 4’500 5 – 7 5 – 7 5 – 7<br />

Duomat 4’000 – 4’500 5 – 7 5 – 7 5 – 7<br />

Automix Tytin reg. 400 mg 600 mg 800 mg<br />

Dry oral environment<br />

Before applying the amalgam, take the necessary precautions<br />

to ensure a dry environment (e.g. use Hygenic®<br />

Dental Dam).<br />

Cavity lining<br />

Dentin and pulp should be protected against infiltration<br />

using appropriate materials.<br />

Matrix<br />

In order to be able to adequately condense the amalgam<br />

in approximal cavity areas, the use of a suitable<br />

matrix system is strictly necessary.<br />

Condensing characteristics<br />

Apply small portions to fill the cavity in an optimal<br />

way. Start with small, flat and smooth condensers.<br />

Progressively use bigger condensing instruments the<br />

closer you get to the occlusal surface and overfill the<br />

cavity generously. By burnishing the restoration before<br />

carving, the amalgam is condensed and homogenized.<br />

The use of mechanical and pneumatic condensing<br />

instruments is recommended.<br />

Working time: 2´00´´ – 2´30´´<br />

Setting Time: 2´30´´ – 5´30´´<br />

Carving<br />

Carving can be done immediately after the removal of<br />

the matrix. You may use any suitable, sharp carving instrument.<br />

The cuttings that result must be aspirated<br />

immediately. By burnishing the restoration before<br />

carving, the amalgam is condensed and homogenized.<br />

Polishing<br />

Every amalgam filling must be polished. This should<br />

be done at the earliest 24 hours after placement. Polishing<br />

of amalgam fillings should always be done under<br />

profuse water cooling. To avoid generation of<br />

heat during polishing, the rotating instrument should<br />

be run at the lowest possible speed.<br />

Appropriate precautionary measures when removing<br />

amalgam restorations, such as using aspirator, rubber<br />

dam, water spray, keeping the operatory ventilated,<br />

disposing of amalgam residues according to prescriptions<br />

etc, will reduce any danger to the health of<br />

patient and surgery staff due to possible exposure to<br />

mercury.<br />

Note<br />

Keep out of the reach of children!<br />

Should not be used after expiry date.<br />

Only supplied to dentists and dental laboratories or<br />

upon their instructions.<br />

Storage<br />

15–23 °C / 59–73 °F.<br />

Special storage recommendations<br />

Any danger to the health of dentist and surgery staff<br />

by mercury vapours can be avoided by handling mercury<br />

and amalgam correctly during mixing, by storing<br />

the amalgam residues immersed in fixing solution in<br />

firmly sealed containers and by keeping the operatory<br />

ventilated.<br />

Local waste management prescriptions should be followed.<br />

Shelf life and marking<br />

Storage<br />

Coltène® <strong>ORALLOY</strong> <strong>MAGICAP</strong> S fulfills the intended<br />

purpose until the expiration date, which is displayed<br />

on the product or packaging.<br />

Marking<br />

The number is visible on the package.<br />

Technical data<br />

Compressive strength<br />

After 1 hour 200 MPa<br />

After 24 hours 470 MPa<br />

Dimensional stability + 0.03 %<br />

Creep<br />

after 7 days: 0.15 %<br />

Caution<br />

Federal law restricts this devise to sale by or on the order<br />

of a dentist.<br />

Date of issue<br />

April 2010<br />

Coltène/Whaledent AG<br />

Feldwiesenstrasse 20<br />

9450 Altstätten/Switzerland<br />

Tel. +41 (0)71 757 53 00<br />

Fax +41 (0)71 757 53 01<br />

info@coltenewhaledent.ch<br />

For MSDS see<br />

www.coltenewhaledent.com