INSTALLATION AND OPERATION MANUAL<br />
<strong>Whale</strong> <strong>Fresh</strong> <strong>IC</strong> freshwater pump<br />
INSTALLATION & USER INSTRUCTIONS<br />
Thank you for purchasing this <strong>Whale</strong>® product.<br />
For over 40 years, <strong>Whale</strong>® has led the way in the design and manufacture of freshwater<br />
and waste systems including: pumps, plumbing, faucets and showers for low voltage<br />
applications. The company and its products have built a reputation for quality, reliability<br />
and in<strong>no</strong>vation backed up by excellent customer service.<br />
For information on our full range of products visit www.whalepumps.com<br />
1. SPECIF<strong>IC</strong>ATION<br />
Product Code FW5082(B) FW5084(B)<br />
Voltage 12 V d.c. 24 V d.c.<br />
Open Flow Rate 13 Ltrs (3.4 US gals)/min 13 Ltrs (3.4 US gals)/min<br />
Ingress Protection Rating IP65 IP65<br />
Recommended Fuse Size 12 Amp 6 Amp<br />
Minimum Wire Size 2.5mm² (13 AWG) 2.5mm² (13 AWG)<br />
Weight 2.95kg (6.5 lbs) 2.95kg (6.5 lbs)<br />
Static System Pressure 2.2 bar (32psi)<br />
Maximum Running Pressure 4.3 bar (62 psi)<br />
Hose Connections<br />
<strong>Whale</strong>® Quick Connect 15mm female<br />
Materials<br />
Model Number Description<br />
Materials in Contact with Fluid<br />
FW5082 <strong>Fresh</strong> <strong>IC</strong> <strong>Fresh</strong>water Pump - 12 V d.c. Retail<br />
FW5082B <strong>Fresh</strong> <strong>IC</strong> <strong>Fresh</strong>water Pump - 12 V d.c. Bulk<br />
FW5084 <strong>Fresh</strong> <strong>IC</strong> <strong>Fresh</strong>water Pump - 24 V d.c. Retail<br />
FW5084B <strong>Fresh</strong> <strong>IC</strong> <strong>Fresh</strong>water Pump - 24 V d.c. Bulk<br />
2. LIST OF CONTENTS<br />
1. SPECIF<strong>IC</strong>ATION 10. INSTRUCTIONS FOR USE<br />
2. CONTENTS AND LIST OF DIAGRAMS 11. MAINTENANCE<br />
3. PRINCIPLES OF OPERATION 12. TROUBLE SHOOTING<br />
4. TO THE USER 13. WINTERIZING<br />
5. TO THE FITTER 14. SERV<strong>IC</strong>E SUPPORT DETAILS<br />
6. APPL<strong>IC</strong>ATION 15. PATENTS/ TRADEMARKS<br />
7. WARNINGS 16. WARRANTY STATEMENT<br />
8. PARTS LIST 17. EU DECLARATION OF<br />
9. INSTALLATION CONFORMITY, APPROVALS<br />
List of Diagrams - Fig. 1 Typical Installation<br />
For ½" (12.5mm) flexible hose use WX1584 (<strong>no</strong>t supplied with pump)<br />
Pump Body: Glass-filled polypropylene<br />
Motor Casting: Powder coated steel<br />
Feet, diaphragm & valves: Mo<strong>no</strong>prene®, Santoprene®<br />
Seals: Nitrile Fasteners: Stainless Steel<br />
Glass-filled polypropylene, Mo<strong>no</strong>prene®, Santoprene®, Nitrile,<br />
Stainless Steel<br />
Service Kits AK1319 - Replacement Strainer<br />
ENG