ETTC'2003 - SEE
ETTC'2003 - SEE ETTC'2003 - SEE
4.2 COMPONENT DEGRADATION MEASUREMENT Another application of the bench is to test specific component such as filters, LNB, TWTA, etc. As example, the figure shows the performance and degradation due to specific payload filtering. In this example, the filter used doesn't introduce significant degradation and it could be possible to relax its specifications (in line with the link budget losses associated with this filter). As the input/output of each rack is standardised, it is very easy to integrate and test commercial equipment as well as breadboards or engineering models. 5 CONCLUSION 1,00E-02 1,00E-03 1,00E-04 1,00E-05 1,00E-06 1,00E-07 1,00E-08 1,00E-09 1,00E-10 Simulation SPW 3,2 3,3 3,4 3,5 3,6 3,7 3,8 3,9 4 4,1 Within the framework of ATF project, CNES is developing a bench called BST to study transmission satellite systems as well as degradation due to specific element of the transmission chain. This bench is principally devoted to the analysis of multimedia satellite systems and it could represent up to fifteen interferers taking into account adjacent and co-frequency beams. Specific components have been developed which are now available and could serve for many applications even in non-satellite systems. Version 0.0 Version 0.1 Version 1.0 Version 1.2 Version 1.3 6
BACK Robust control of a high speed test bench for mechanical structures Valérie POMMIER-BUDINGER ‡ , Xavier Carbonneau ‡ , Jean-Luc LATAILLADE* and Alain OUSTALOUP † ‡ ENSICA - 1, Place Blouin, 31056 Toulouse - France fax: +33 (0)561 618 686 e-mail: valerie.pommier@ensica.fr LAMEFIP – ENSAM – Esplanade des Arts et Métiers, 33405 Talence - France † LAP – Université de Bordeaux I, 351 cours de la Libération, 33405 Talence - France Abstract This paper presents a high speed test bench in project and the control system design that permits to use as well as possible this test device. The test bench is made of a hydraulic actuator whose cylinder is linked to a mechanical structure to be tested. The tested structure is to be compressed by the actuator whose cylinder position is controlled and follows a given trajectory. The control system must take into account the fact that the parameters of the tested structure are not well-known and change during the test. This paper also presents the different test devices available in two laboratories at ENSICA and ENSAM Introduction Tests are often to be achieved under specifications such as velocity, force or temperature. In order to guaranty these specifications, control system design is a precious tool. Control system design requires modelling all the devices: the test machine, the sensors and the tested structure. This is not so easy concerning the tested structure. ETTC2003 European Test and Telemetry Conference
- Page 364 and 365: Pression Ligne bifilaire non blind
- Page 366 and 367: 1.8 1,8 Tension continue V 1.6 1.4
- Page 368 and 369: 270 Ω I0 IL 2,7 kΩ (b) Alimenta
- Page 370 and 371: What is the budget of the statistic
- Page 372 and 373: Monte Carlo approach: This is a thr
- Page 374 and 375: 2 Etat de l’art des standards de
- Page 376 and 377: 2.1.6 Emissions standards 61967 par
- Page 378 and 379: - Limites pour l’immunité DPI (e
- Page 380 and 381: PRESENTATIONS POSTER / POSTER PRESE
- Page 382 and 383: BACK LA TELEMESURE SUR AIRBUS JC GH
- Page 384 and 385: Dans le cycle d ’essais en vol ,
- Page 386 and 387: CONCLUSION - NOS BESOINS FUTURS AIR
- Page 388 and 389: LOGICIELS DE MESURE ET DE TRAITEMEN
- Page 390 and 391: LOGICIELS DE MESURE ET DE TRAITEMEN
- Page 392 and 393: LOGICIELS DE MESURE ET DE TRAITEMEN
- Page 394 and 395: In order to optimize the phase nois
- Page 396 and 397: Photo-oscillator active device Opti
- Page 398 and 399: the inverse of N×N correlation mat
- Page 400 and 401: quasi-synchronous multiuser detecto
- Page 402 and 403: Multiuser Interference Canceler ”
- Page 404 and 405: the inverse of N×N correlation mat
- Page 406 and 407: quasi-synchronous multiuser detecto
- Page 408 and 409: Multiuser Interference Canceler ”
- Page 410 and 411: All these sub-systems can be easily
- Page 412 and 413: 3.5 ACPR RACK Gateway and satellite
- Page 416 and 417: Indeed, when the objective of the t
- Page 418 and 419: All the five points can be achieved
- Page 420 and 421: M r Mmax (0 dB, -180°) b = 0 a ωc
- Page 422 and 423: 2 - Test devices at ENSICA Souffler
- Page 424 and 425: Soufflerie à Densité Variable (SD
- Page 426 and 427: Capacité : - pour la charge axiale
- Page 428 and 429: Machine d’essai de fatigue en fle
- Page 430 and 431: torsion. - asservissement de chaque
- Page 432 and 433: KEY 1 WORD IENA PACKET format An IE
- Page 434 and 435: TD: “0” means that the paramete
- Page 436 and 437: PARAMETER DESCRIPTION This array de
- Page 438 and 439: BACK UTILISATION de CAMERAS NUMERIQ
- Page 440 and 441: TABLE DES MATIÈRES 1. INTRODUCTION
- Page 442 and 443: 2. CONTEXTE DES ESSAIS Le but des e
- Page 444 and 445: 3. LES BESOINS ET LES CONTRAINTES 3
- Page 446 and 447: 4. CHOIX DE LA CAMERA 4.1 Démarche
- Page 448 and 449: 5.1.4 Adaptations Les deux principa
- Page 450 and 451: Tir d'un missile AIR/AIR éjecté T
- Page 452 and 453: 6. CONCLUSION Cette évaluation mon
- Page 454 and 455: Capteur Intelligent IEEE 1451.4 Pri
- Page 456 and 457: pC/g Piezo Accelerometer mV/g Piezo
- Page 458 and 459: BACK F. Mailly et Al. ETTC 2003 MIC
- Page 460 and 461: 4.2. Sensitivity according to the h
- Page 462 and 463: BACK STUDY OF 3∆t PASSIVE LOCATIN
4.2 COMPONENT DEGRADATION MEASUREMENT<br />
Another application of the bench is to test specific<br />
component such as filters, LNB, TWTA, etc.<br />
As example, the figure shows the performance<br />
and degradation due to specific payload filtering.<br />
In this example, the filter used doesn't introduce<br />
significant degradation and it could be possible to<br />
relax its specifications (in line with the link<br />
budget losses associated with this filter).<br />
As the input/output of each rack is standardised, it<br />
is very easy to integrate and test commercial<br />
equipment as well as breadboards or engineering<br />
models.<br />
5 CONCLUSION<br />
1,00E-02<br />
1,00E-03<br />
1,00E-04<br />
1,00E-05<br />
1,00E-06<br />
1,00E-07<br />
1,00E-08<br />
1,00E-09<br />
1,00E-10<br />
Simulation SPW<br />
3,2 3,3 3,4 3,5 3,6 3,7 3,8 3,9 4 4,1<br />
Within the framework of ATF project, CNES is developing a bench called BST to study transmission<br />
satellite systems as well as degradation due to specific element of the transmission chain. This bench is<br />
principally devoted to the analysis of multimedia satellite systems and it could represent up to fifteen<br />
interferers taking into account adjacent and co-frequency beams. Specific components have been<br />
developed which are now available and could serve for many applications even in non-satellite systems.<br />
Version 0.0<br />
Version 0.1<br />
Version 1.0<br />
Version 1.2<br />
Version 1.3<br />
6