4.7 Connecting the communications module<br />

(<strong>StecaGrid</strong> Connect)<br />

If the <strong>StecaGrid</strong> Connect option is used with an external communications connection,<br />

the connection plug is located on the above left of the daughterboard.<br />

An aperture can be cut out in the lower part of the control unit for the cable<br />

feed. After inserting the cable hole can be sealed with the supplied blan plug.<br />

Further information regarding connection of the daughterboard can be found in<br />

the manual supplied with the daughterboard.<br />

The SubD9 plug connector (above right) is only used for maintenance purposes.<br />

Improper use can damage the inverter and will invalidate the warranty.<br />

4.8 Switching the grid voltage on for the first time<br />

When energy is being supplied the inverter continuously checks the quality of<br />

the electricity grid. If the grid quality is poor the inverter will automatically disconnect<br />

itself. The criteria according to which the inverter disconnects itself vary<br />

from country to country and are listed in the table in the appendix. This is the<br />

so-called "table of countries". The specific criteria according to which the inverter<br />

disconnects itself are fixed by law.<br />

When commissioning the inverter, first the language then the country should<br />

be set. Select the country in which the inverter is installed; the inverter thereby<br />

fulfils the national requirements. The setting is made using the display and arrow<br />

buttons.<br />

The country setting can only be carried out once. Following selection, a normal<br />

user can only choose between the standard setting and the chosen country<br />

setting. The enclosure contains a table with countries and the relevant country<br />

setting.<br />

If the wrong country setting is still selected this country setting can be changed<br />

by an installer who has the necessary service software.<br />

After connecting the AC side with the grid the inverter autonomously synchronises<br />

with the mains.<br />

7 6.439 | 10.04<br />

39