02-CATALOGO-Raychem
Raychem Termination Systems for Polymeric Insulated Cables 72 kVTechnical dataCable insulation diameter rangeMaximum voltage to groundBasic impulse level30 to 86 mm (5 sizes)1.18 to 3.39 inches40 kVoutdoor ± 350 kVindoor ± 350 kVMaximum continuous conductor 90 °Coperating temperatureMaximum conductor 130 °Cemergency temperature1 s conductor short circuit temperature 250 °CCreepage length*indoor >1450 mm (57.0 inches)outdoor >1900 mm (74.8 inches)* Longer creepage length on requestThe termination has been tested in accordance with international specifi cations(e.g., IEEE 48, IEC 60840).For 52 kV polymeric insulated cables similar termination systems are available.Stripping tool for XLPE cable:Raychem's stripping tool, designed toremove both semi-conductive screenand dielectric, will help professionaljointers to overcome this difficulty.All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct andreliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance ofany particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for theseproducts is set forth in our standard terms and conditions of sale. Raychem, TE Logo and Tyco Electronics are trademarks.Energy Division – innovative and economical solutions for the electrical power industry: cable accessories, connectors &fittings, insulators & insulation, surge arresters, switching equipment, lighting controls, power measurement and control.© Tyco Electronics EPP 0413 11/08Tyco Electronics Raychem GmbHEnergy DivisionFinsinger Feld 185521 Ottobrunn/Munich, GermanyPhone: +49-89-6089-0Fax: +49-89-6096345http://energy.tycoelectronics.com
Energy DivisionRaychem Link Boxes
- Page 39 and 40: ÍndiceHVBTCINTA TERMOCONTRACTIL CO
- Page 41 and 42: ÍndiceLVITTUBO TERMOCONTRACTIL PAR
- Page 43 and 44: ÍndiceBCICCUBIERTA AISLANTE PREMOL
- Page 45 and 46: ÍndiceBISGDISCO AISLADOR PARA PROT
- Page 47 and 48: ÍndiceHSHIAISLADOR HÍBRIDO 5-25 K
- Page 49 and 50: ÍndiceMVLCCUBIERTA PROTECTORA PARA
- Page 51 and 52: ÍndiceDAHAPARTARRAYOS DE DISTRIBUC
- Page 53 and 54: ÍndiceUDCCONECTOR DERIVADOR TIPO C
- Page 55 and 56: ÍndiceSGCCONECTORES PUESTA A TIERR
- Page 57 and 58: ÍndiceTGCConectores Puestas a Tier
- Page 59 and 60: ÍndiceUTILUXCONECTADOR RECTO DE CO
- Page 61 and 62: ÍndiceSHRINKMARKSISTEMA DE ETIQUET
- Page 63 and 64: ÍndiceROTA CRIMPINZAS DE COMPRESI
- Page 65 and 66: ÍndiceBANTAM-R-CHERRAMIENTAS DE CO
- Page 67 and 68: ÍndiceACCESORIOS PARA SOPLETEFH-AD
- Page 69 and 70: ÍndiceTFTTERMINALES TERMOCONTRÁCT
- Page 71 and 72: InicioBPTMTUBO TERMOCONTRÁCTIL PAR
- Page 73 and 74: InicioMVLCCUBIERTA PROTECTORA PARA
- Page 75 and 76: InicioHVCEEXTENSOR DE DISTANCIA DE
- Page 77 and 78: AnteriorSiguiente
- Page 79 and 80: AnteriorSiguiente
- Page 81 and 82: AnteriorSiguiente
- Page 83 and 84: AnteriorSiguiente
- Page 85 and 86: Energy DivisionRaychem Inline andSh
- Page 87 and 88: Energy DivisionRaychem Termination
- Page 89: Construction and designOutdoorContr
- Page 93 and 94: Most popular cable sheath grounding
- Page 95 and 96: Selection tables for Raychem Link B
- Page 97 and 98: Selection tables for Raychem Link B
- Page 99 and 100: Energy DivisionRaychem Outdoor Comp
Energy Division
Raychem Link Boxes