13.07.2015 Views

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ON THE SURFACEAfter returning to the surface, inflate the BC to become positivelybuoyant.BACKPACKUsing a hose, flush fresh water through the inside of the backpack(photo 11). WARNINGThe B/C of your HUB is not a safety jacket or personalfloatation device it is not designed to keep the diver onthe surface in a head up position should he/shebecome unconscious.END OF DIVEAt the end of the dive, close the air valve and purge the residual airfrom the HUB system.Disconnect the first stage, and after rinsing with fresh water andreplace it inside its compartment. WARNINGMake sure that all the residual air in the HUB systemhas been completely discharged before unscrewing theyoke knob.Loosen the tank strap and remove the HUB.Completely discharge the air contained in the BC, by pulling one ofthe mechanical quick air dump valves completely rinse the HUB withfresh water, ensuring that the first stage protection cap is secure.To stow the HUB, fold it over on itself and close the cummerbund.Cross over the quick-release shoulder straps to obtain a morecompact size, (photo 10).HIGH PRESSURE INSTRUMENTTake the pressure gauge/console from the pocket and rinse.- 11BCCheck that there is no water inside the BC.Discharge any water as follows:- fully inflate the BC- position it as shown in photo 12, to allow the water to flow intothe front bag- 10Replace HUB in its bag.MAINTENANCEIn the case of repetitive dives, between one dive and the nextsimply rinse the HUB in fresh water by submerging its bag.To carry out a more thorough maintenance, rinse all thecomponents in fresh water.REGULATOR AND ALTERNATIVE SECOND STAGEIdeally, the equipment should be rinsed in fresh water while it isstill pressurized, as this makes it possible to thoroughly wash thesecond stage without introducing any impurities.If the regulator is not pressurized, do not press the purge buttonduring rinsing.Take particular care, after disassembling the group from the tank,to replace the dust/moisture cap on the first stage prior to rinsing.- 12- turn the BC over so that the mechanical quick air dump valve isfacing downward and discharge the water by pulling the valvecord (photo 13).15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!