13.07.2015 Views

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

limitazioni riferimenti alla en1809-scopo-def - Frogkick.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tighten and secure the tank strap (Fig. 6).Take out the second stage and, pressing its purge button, slowlyturn the tank valve to the fully open position, then back one half turn. WARNINGDuring this procedure, press the manual purge buttonof the second stage to reduce the impact on the valve.Do not perform this maneuver in environments wherethe temperature is below 10° C. CAUTIONThe B/C of your HUB was designed to be used with airtanks having the following minimum and maximumcharacteristics:Diameter:min. 14.1 cm (5.5 in) - max. 21.5 cm (8.5 in)Volume: single tank: min. 5 l (35 cu. ft.) -max. 20 l (140 cu. ft.)double tank: min 2 x 5 l (2 x 35 cu. ft.) -max 2 x 10 l (2 x 70 cu. ft.)As with traditional BCs, it is recommended to wet the straps beforeattaching the HUB to the tank.To check that the tank is securely attached, proceed as follows:a) open the buckle of the positioning strap.b) turn and re-close the buckle so as to be able to grip the strap,and lift the HUB-tank group (Fig. 7).- 6After checking that the primary second stage is in perfect workingorder, it is necessary to also check the alternative second stage.To access the alternative second stage, open its specialcompartment by pulling upward on the yellow knob in the lowerright-hand pocket.After checking the operation of the alternative second stage, replaceit inside its compartment, taking care to coil the hose correctly.After completing the check of both regulators, check the tankpressure using the submersible pressure gauge or the console inthe left pocket.Next, check the operation of the pneumatic inflation and <strong>def</strong>lationsystem by pressing the IN and OUT buttons.Finally, check the oral inflation system using the silicone tubeinside the left pocket.Fully extract the tube and blow into it to inflate the BC.Replace its cap and correctly reposition the tube inside the pocket. WARNINGRemember to fully extract the oral inflation tube beforeblowing inside.DONNING THE HUBBefore donning the HUB, check that all the components of theintegrated system are positioned correctly. WARNINGRemember to stow the carrying handle of the HUBinside its compartment when HUB is in use.This maneuver is essential for ensuring that the tank will not slipout of the retaining straps.c) re-open the buckle and reconnect the positioning strap asshown in Fig. 5.Take the first stage out of its compartment and, after removing thedust/moisture cap, assemble it on the tank valve after havingchecked that the O-ring seal is in perfect condition.- 7PERFORMING THE BUDDY-CHECKAlthough the working principle of the HUB is the same as that of aconventional scuba gear, it is necessary to have a properunderstanding of its operation, which is slightly different.Before entering the water, ask your buddy to familiarize his orherself with how the HUB works by going through a normal predivecheck particularly sharing air procedures.Always practice this essential procedure, which enhances yourown safety and that of your buddy.The fundamental check points are listed below:1) Check that the tank strap is secure.2) To check that the tank is open, take the primary second stagefrom the right pocket and the console from the left pocket;breathe through the regulator a few times while checking theconsole.The reading of the pressure gauge should not change.3) Press the "IN" button of the inflator unit to inflate the BC by asmall amount.Then check the <strong>def</strong>lation by pressing the "OUT" button.Alternatively, it is possible to use the oral inflation tube stowedinside the left pocket.4) Check the operation of the quick air dump valves.ENTRY PROCEDUREAfter having completed the pre-dive check, take the primarysecond stage from the right pocket, inflate the BC with the thumbof your left hand and check that the mask is correctly positioned onyour face: you are now ready to go into the water.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!