AirConServiceCenter ASC2500 - WAECO - AirCon Service
AirConServiceCenter ASC2500 - WAECO - AirCon Service AirConServiceCenter ASC2500 - WAECO - AirCon Service
_ASC2500_de_en_es_fr_ru.book Seite 94 Dienstag, 3. Mai 2011 10:24 10Service tasksAirCon Service Center“R134a to system” indicates how many grams of refrigerant have beenadded to the air conditioning systems using the menu item “Shortselection” or “Free selection” since the last reset (see date).“Vacuum time” indicates how long the vacuum pump has operated sincethe last reset (see date).“Service completed” displays the amount of service work performedusing the air conditioning service unit since the last reset (see date).9.4 Calibrating the pressure transducerINOTEThe pressure transducer has to be correctly calibrated in order to makeaccurate pressure measurements.Calibration is required:• Every four weeks• If the AirConServiceCenter has been subjected to heavy shaking• Every time the vacuum pump oil is changed• If the display shows implausible pressure readings1. In the basic menu, use the cursor keys or to select “Otherselections”:2. Press ENTER to confirm.3. Use the cursor keys or to select “Service”:4. Press ENTER to confirm.R134a to system07/09/10g. 1200STOP-EXITVacuum time07/09/10min. 79STOP-EXITService completed:08/09/10Number 4STOP-EXITShort selectionFree selectionOther selectionsENTER-OKInt. vessel fillingFlushingReset scales.Service.94EN
_ASC2500_de_en_es_fr_ru.book Seite 95 Dienstag, 3. Mai 2011 10:24 10AirCon Service CenterService tasksINOTE5. Enter the password “2224”.6. Confirm “Pressure transducer” by pressing ENTER.7. Then follow the instructions in the display.• Unscrew the service couplings (12) and (13) from the servicehoses (10) and (11).• Use the keypad (7) to enter the current local atmospheric pressureand press ENTER to confirm.You can look up the current atmospheric pressure for your region on theInternet, for example at http://www.meteo24.de/wetter/ under “air pressure”.8. When calibration has been completed, press ENTER to exit the menu.9. Press STOP twice to access the standby menu.10. Screw the service couplings (12) and (13) hand-tight onto the servicehoses (10) and (11), taking care not to mix up the red and bluemarkings on the couplings and hoses.EN 95
- Page 43 and 44: _ASC2500_de_en_es_fr_ru.book Seite
- Page 45: _ASC2500_de_en_es_fr_ru.book Seite
- Page 49 and 50: _ASC2500_de_en_es_fr_ru.book Seite
- Page 51 and 52: _ASC2500_de_en_es_fr_ru.book Seite
- Page 53 and 54: _ASC2500_de_en_es_fr_ru.book Seite
- Page 55 and 56: _ASC2500_de_en_es_fr_ru.book Seite
- Page 57 and 58: _ASC2500_de_en_es_fr_ru.book Seite
- Page 59 and 60: _ASC2500_de_en_es_fr_ru.book Seite
- Page 61 and 62: _ASC2500_de_en_es_fr_ru.book Seite
- Page 63 and 64: _ASC2500_de_en_es_fr_ru.book Seite
- Page 65 and 66: _ASC2500_de_en_es_fr_ru.book Seite
- Page 67 and 68: _ASC2500_de_en_es_fr_ru.book Seite
- Page 69 and 70: _ASC2500_de_en_es_fr_ru.book Seite
- Page 71 and 72: _ASC2500_de_en_es_fr_ru.book Seite
- Page 73 and 74: _ASC2500_de_en_es_fr_ru.book Seite
- Page 75 and 76: _ASC2500_de_en_es_fr_ru.book Seite
- Page 77 and 78: _ASC2500_de_en_es_fr_ru.book Seite
- Page 79 and 80: _ASC2500_de_en_es_fr_ru.book Seite
- Page 81 and 82: _ASC2500_de_en_es_fr_ru.book Seite
- Page 83 and 84: _ASC2500_de_en_es_fr_ru.book Seite
- Page 85 and 86: _ASC2500_de_en_es_fr_ru.book Seite
- Page 87 and 88: _ASC2500_de_en_es_fr_ru.book Seite
- Page 89 and 90: _ASC2500_de_en_es_fr_ru.book Seite
- Page 91 and 92: _ASC2500_de_en_es_fr_ru.book Seite
- Page 93: _ASC2500_de_en_es_fr_ru.book Seite
- Page 97 and 98: _ASC2500_de_en_es_fr_ru.book Seite
- Page 99 and 100: _ASC2500_de_en_es_fr_ru.book Seite
- Page 101 and 102: _ASC2500_de_en_es_fr_ru.book Seite
- Page 103 and 104: _ASC2500_de_en_es_fr_ru.book Seite
- Page 105 and 106: _ASC2500_de_en_es_fr_ru.book Seite
- Page 107 and 108: _ASC2500_de_en_es_fr_ru.book Seite
- Page 109 and 110: _ASC2500_de_en_es_fr_ru.book Seite
- Page 111 and 112: _ASC2500_de_en_es_fr_ru.book Seite
- Page 113 and 114: _ASC2500_de_en_es_fr_ru.book Seite
- Page 115 and 116: _ASC2500_de_en_es_fr_ru.book Seite
- Page 117 and 118: _ASC2500_de_en_es_fr_ru.book Seite
- Page 119 and 120: _ASC2500_de_en_es_fr_ru.book Seite
- Page 121 and 122: _ASC2500_de_en_es_fr_ru.book Seite
- Page 123 and 124: _ASC2500_de_en_es_fr_ru.book Seite
- Page 125 and 126: _ASC2500_de_en_es_fr_ru.book Seite
- Page 127 and 128: _ASC2500_de_en_es_fr_ru.book Seite
- Page 129 and 130: _ASC2500_de_en_es_fr_ru.book Seite
- Page 131 and 132: _ASC2500_de_en_es_fr_ru.book Seite
- Page 133 and 134: _ASC2500_de_en_es_fr_ru.book Seite
- Page 135 and 136: _ASC2500_de_en_es_fr_ru.book Seite
- Page 137 and 138: _ASC2500_de_en_es_fr_ru.book Seite
- Page 139 and 140: _ASC2500_de_en_es_fr_ru.book Seite
- Page 141 and 142: _ASC2500_de_en_es_fr_ru.book Seite
- Page 143 and 144: _ASC2500_de_en_es_fr_ru.book Seite
_<strong>ASC2500</strong>_de_en_es_fr_ru.book Seite 94 Dienstag, 3. Mai 2011 10:24 10<strong>Service</strong> tasks<strong>AirCon</strong> <strong>Service</strong> Center“R134a to system” indicates how many grams of refrigerant have beenadded to the air conditioning systems using the menu item “Shortselection” or “Free selection” since the last reset (see date).“Vacuum time” indicates how long the vacuum pump has operated sincethe last reset (see date).“<strong>Service</strong> completed” displays the amount of service work performedusing the air conditioning service unit since the last reset (see date).9.4 Calibrating the pressure transducerINOTEThe pressure transducer has to be correctly calibrated in order to makeaccurate pressure measurements.Calibration is required:• Every four weeks• If the <strong><strong>AirCon</strong><strong>Service</strong>Center</strong> has been subjected to heavy shaking• Every time the vacuum pump oil is changed• If the display shows implausible pressure readings1. In the basic menu, use the cursor keys or to select “Otherselections”:2. Press ENTER to confirm.3. Use the cursor keys or to select “<strong>Service</strong>”:4. Press ENTER to confirm.R134a to system07/09/10g. 1200STOP-EXITVacuum time07/09/10min. 79STOP-EXIT<strong>Service</strong> completed:08/09/10Number 4STOP-EXITShort selectionFree selectionOther selectionsENTER-OKInt. vessel fillingFlushingReset scales.<strong>Service</strong>.94EN