_<strong>ASC2500</strong>_de_en_es_fr_ru.book Seite 86 Dienstag, 3. Mai 2011 10:24 10Operation<strong>AirCon</strong> <strong>Service</strong> Center8.6.3 Filling process1. Enter the preferred settings and press ENTER to confirm.Fillingphase?YesNoINOTE2. If “Filling phase” has been selected, enter the required value,otherwise continue with “Select connections”.3. Enter the refrigerant oil quantity.4. Press the cursor key .5. Enter the additive quantity.6. Press the cursor key .7. Enter the refrigerant quantity.8. Press ENTER to confirm all settings.• If extraction is taking place in the same process sequence, the quantity offresh oil is counted as an additional filling quantity, and is added to thedrained oil quantity extracted beforehand. If this value is set to 0, exactlythe quantity of oil which was extracted will be filled again.• To add fresh oil or UV additive, a vacuum process must be performed inthe same process sequence. If no vacuum process has been selected,only refrigerant can be selected in the filling menu.8.6.4 Selecting connectionsENTER-OK STOP-EXITPAG oil ml. 1UV tracer ml. 7Refrigerant g. 500ENTER-OK STOP-EXIT1. Select the parameters in accordance with the air conditioning systemconnections:• Air conditioning system has a high pressure and a low pressureconnection: Select LP / HP.• Air conditioning system only has a high pressure connection:Select HP.• Air conditioning system only has a low pressure connection:Select LP.86EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!