_<strong>ASC2500</strong>_de_en_es_fr_ru.book Seite 69 Dienstag, 3. Mai 2011 10:24 10<strong>AirCon</strong> <strong>Service</strong> CenterInitial start-up7.6 Editing default valuesThe <strong><strong>AirCon</strong><strong>Service</strong>Center</strong> has preset values for the most importantservice tasks. The default values appear automatically when you selectthe respective menu.You can alter the following default values if necessary:Parameter:Default value:Pressure increase test time min. 1Vacuum time min. 20Leak test min. 4PAG oil ml. (additional quantity) 0UV tracer ml. 7Filling Qt. g. 500Print recovery value?1. In the basic menu, use the cursor keys or to select “Otherselections”:Short selectionFree selectionOther selectionsENTER-OK2. Press ENTER to confirm.3. Use the cursor key to select “<strong>Service</strong>”.4. Press ENTER to confirm.5. Enter the password “7388”.6. Use the keypad and the cursor keys to enter the information.7. Press ENTER to confirm.8. Press STOP to access the standby menu.YesEN 69