_<strong>ASC2500</strong>_de_en_es_fr_ru.book Seite 107 Dienstag, 3. Mai 2011 10:24 10<strong>AirCon</strong> <strong>Service</strong> CenterTroubleshootingProblem Cause RemedyThe display shows“Not enough UV. Add!”The display shows“Not enough oil. Add!”The display shows“Max. filling timeexceeded! Carry on?”The display shows“External tank empty orclosed valve. Check!”The display shows“Change the equipmentdrier filter! Carry on?”The display shows“Change the vacuumpump oil! Carry on?”The display shows“Printer not in line! Carryon?”The display shows“Error 01”The display shows“Error 02”The display shows“Error 09”This message appearsduring the filling process ifthere is not enough UVadditive in the container tofinish the process.Message that appears duringthe filling process if there isnot enough fresh oil in thecontainer to finish theprocess.Message that appears duringthe filling process if the setamount of refrigerant cannotbe filled.Message that appears at thestart or during the filling ofthe internal refrigerantcontainer if the set refrigerantquantity cannot be attained.This message appears whenyou switch on the<strong><strong>AirCon</strong><strong>Service</strong>Center</strong>.This message appears whenyou switch on the<strong><strong>AirCon</strong><strong>Service</strong>Center</strong>.Message indicates a printerfault.Refrigerant was addedbefore draining wascompleted.The air conditioning systemis leaking. There is stillrefrigerant in the airconditioning system.Low pressure connector notconnected to the flushcontainer during flushing.Fill the UV additive container.Top up the fresh oil containerwith a suitable oil type.Check that<strong><strong>AirCon</strong><strong>Service</strong>Center</strong>connections are not blocked.Check if the externalrefrigerant container stillcontains enough refrigerantor if the valves of the externalrefrigerant container areopen.Change the internal filter assoon as possible (seePage 92). To skip this, pressENTER for 3 seconds.Change the vacuum pump oilas soon as possible (seePage 96). To skip this, pressENTER for 3 seconds.Check if there is paper in theprinter.Check if the printer isswitched on (yellow LEDmust light up constantly).Check that the cover isclosed properly.Repeat the drainingprocedure; do not interrupt itthis time.Fix the leak.Connect low pressure hoseto the flush box and openvalve.EN 107

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!