_<strong>ASC2500</strong>_de_en_es_fr_ru.book Seite 106 Dienstag, 3. Mai 2011 10:24 10Troubleshooting<strong>AirCon</strong> <strong>Service</strong> Center11 TroubleshootingProblem Cause RemedyThe display shows“Warning!Internal vesseloverpressure!”The display shows“Warning!Internal vessel full!”The display shows“Warning!Pressure inside the A/Csystem.Recovery start!”The display shows“Warning!Pressure inside the A/Csystem!”The display shows“Not enough vacuum!Carry on?”The display shows“A/C system leakage!Carry on?”The display shows“Drained oil glassemptying!”The display shows“Warning!Not enough vacuum forinjection!”The display shows“Quantity too large.Fill internal vessel!”Normal message thatappears during the recyclingprocess.The internal refrigerantcontainer is too full to holdthe quantity to be extracted.Normal message thatappears at the start of thevacuum process. There isstill pressure present in theair conditioning system.Message during the vacuumprocess. There is pressure inthe air conditioning system.Message that appears duringthe vacuum process if thepressure in the airconditioning system after8 minutes is still more than50 mbar.Message at the end of thevacuum process. The airconditioning system shows avacuum loss of more than120 mbar during thechecking time.This message appearsduring the extraction orrecycling process if there ismore than 150 ml of used oilin the container.Message that appears duringthe filling phase if thevacuum in the airconditioning system isinsufficient to end theprocess.Message that appears duringthe process input if there isnot enough refrigerant in theinternal container tocomplete the process.To continue, press ENTERfor three seconds.If this message appearsrepeatedly, notify customerservices.Drain the internal refrigerantcontainer in the propermanner.No action is required. Theprocess continuesautomatically.No action is required. Theprocess continuesautomatically.Check the air conditioningsystem or the connectionsbetween it and the<strong><strong>AirCon</strong><strong>Service</strong>Center</strong> forleaks.Check the air conditioningsystem or the connectionsbetween it and the<strong><strong>AirCon</strong><strong>Service</strong>Center</strong> forleaks.Dispose of the content of theused oil container in anenvironmentally responsiblemanner.Check the air conditioningsystem or the connectionsbetween it and the<strong><strong>AirCon</strong><strong>Service</strong>Center</strong> forleaks.Fill the refrigerant container.106EN

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!