-•CONEXIONES DETECTOR DE INCENDIO 4 HILOSNEGROROJOVERDEAMAR.OPCIONALPARA HASTA 40 ZONAS ADICIONALES(DESDE UNO O AMBOS GRUPOS)CONECTOR DE 8 PINESUSADO PARA LAS CONEXIONES DEL INTERFACEDE PORTADORA DE LINEA XM10E EN(ESPANA, CHILE, ARGENTINA, PARAGUAY, URAGUAY)4300 (EN OTRA PAÍSES Y PARA LAS SALIDASAUX. (TRIGGERS) EN PLACA VER INSTRUCCIONESFUSIBLE BATERIAAL REPONERUTILIZAR ELMISMO VALOR(Ej. ADEMCO No. 90-12)3ACAPACIDAD BATERIA PARA AUTONOMIA DEEMERGENCIA ROBO USAR POR LO MENOS 4 HRS++ROJOTERMINALESSALIDAALIMENT.AUXILIARMODULO RELESDE SUPERVISIONRFL A77-716B.USARCONTACTO N.A.,EL CUAL SECIERRA ALAPLICARTENSION.7 8 (USAR CABLESA4120XM-1)1 2 3 4 5 6_VIOLETA5ATRANS.4_+NGRSINCCOMDATOS_RELEPROGRAMARRELE COMOTIPO ZONA 54(RESTABLECL.ZONA FUEGO)N.C.CONTACTO SE ABREMOMENTANEAMENTE CONREST. ALARMA FUEGOCONECTORESBATERIABATERIANEGRO12V, 4AHMINIMO + ROJO+TENSION DE CARGA13.8VCC. MAXIMACORRIENTE DE CARGA650mA.RFL2000OHMS.Y/O+12 AUXGNDSALIDA 18(TRIG. 2)SALIDA 17(TRIG. 1)A ZONATERM. ( )DETECTORTEMPERATURA+A ZONA TERM. ( )_---N.A.OCONFIGURARMICRO-INTERRUPTORESDIP DELRECEPTORPARA DIRECCION“0”.VERINSTRUCCIONES.CONFIGURARMICRO-INTERRUPTORESDIP DE LAUNIDAD PARADIRECCIONES7 - 15VERINSTRUCCIONES.ADEMCO 6164CON 4 ZONAS MAS 1 RELE-O-ADEMCO 4219MODULO EXPANSOR CABLEADO(8 ZONAS CABLEADAS RFL)-O-ADEMCO 4229MODULO EXPANSOR/RELES(8 ZONAS RFL CABLEADASMAS 2 RELES DE SALIDA)-O-ADEMCO 4204 MODULO RELES(4 RELES)DETECTOR HUMODE 4 HILOS ODE COMBUSTIONA SALIDA 17PROGRAMAR SALIDA 17COMO "SAL NORM BAJA"= SI EN EL MODOMENU 79 Y COMOTIPO ZONA 54 ENEL MODO MENU 80RECEPTOR RFADEMCO SERIE 5800ZONAS VIA RADIONEGROROJOVERDEAMAR.NEGROROJOVERDAMARA TERM 4A TERM 5A TERM 6A TERM 7PUENTE ROJOCORTAR PARA SUPERVISION SIRENA.TAMBIEN CONECTAR RESISTENCIA2000 OHM. EN SIRENA. NO CORTARPARA SALIDA SIRENA DE ACTIVACIONAUTOMATICA (INVERTIDA''').LAS BATERIA DE TIPO SEALED LEAD-ACIDNORMALMENTE NO NECESITANREEMPLAZARSE HASTA TRANSCURRIDO 3 AÑOSPARA DETERMINAR LA CARGA TOTAL DE RESERVADE LA BATERIA AÑADA 100mA A LA SALIDA TOTAL DEALIMENTACION AUX. Y CONSUMOS DE LASCONSOLAS REMOTAS8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 253 76541 2TRANSFORMADOR ENCHUFABLETIERRA- (RING)(ROJO)+ (TIP)(VERDE)+--++-++--++-+- (RING)(GRIS)+ (TIP)(MARRON)-▲+}}ENTRADALINEA TELEF.SALIDALINEA TELEF.TRANSFORMADOR CABLEADO16.5VCA, 25VA (MINIMO)de 220VCA110VCACONEXIONESTELEFONICAS(CON CLAVIJA RJ31X Y CABLE DECONEXION DIRECTA)AMARILLO: SALIDA DATOS DESDECONSOLA▲VERDE: ENTRADA DATOS DESDECONSOLAROJO: ALIMENT. CONSOLA ( + )NEGRO: TIERRA CONSOLA (- )5.}SALIDA DE CORRIENTEAUXILIAR10.5-13.8VCC600mA MAX.TODAS LASSALIDAS SONDE TENSIONLIMITADA.NOTA:DEBE INCLUIR ENLOS CALCULOSDE CONSUMO DECORRIENTE AUX.EL CONSUMO DELA CONSOLA(S)(DE TODAS LASPARTICIONES)Y DE TODOS LOSDISPOSITIVOSQUE SEALIMENTAN DELOS TERMINALES4 YCONECTAR A220VCA110VCAZONA 8ZONA 7ZONA 6ZONA 5ZONA 4ZONA 3ZONA 2ZONA 1–+AVISO:PARA PREVENIR DESCARGASELECTRICAS DESCONECTE LA LINEATELEFONICA ANTES DE ALIMENTARLA UNIDAD.RFL2000OHMSRFL2000OHMSRFL2000OHMSRFL2000OHMSRFL2000OHMSRFL2000OHMSRFL2000OHMSRFL2000OHMSPUEDE USARSE PARA DETECTORESDE INCENDIO DE 2 HILOS• RESISTENCIA MAXIMA DE LAZO: (CADA ZONA) 300 OHMS. (MAS RFL)• RESPUESTA, ZONAS 1-8: 10, 350, O 700 MSG (PROGRAMABLE)EL NUMERO MAXIMO DE DETECTORES DE INCENDIO DE 2 HILOS EN ZONA 1 ES 1612 13 14SALIDA DE ALARMA10.5–13.8VCC, 2A MAX.SONIDO ININTERRUMPIDOPARA ROBO/PANICOPULSADO TEMPORALPARA FUEGOPUEDE USAR SIRENA 702DE ADEMCO, O SIRENA DE 12VVER INSTRUCCIONES.NOTA ALIMENTACION:EL SISTEMA DETIENE EL PROCESAMIENTODE DETECCION DE LOS SENSORES SIEL VOLTAJE DEL PANEL DE CONTROLBAJA POR DEBAJO DE 9.6V.CONSOLASREMOTAS Y OTROSDISPOSITIVOSDIRECCIONABLES(Ej.. 7845C, 4204,4219, 4229,RECEPTORESSERIE 5800, 7845i)PARESZONAS2 / 103 / 114 / 125 / 136 / 147 / 158 / 162kCONTACTOSTAMPER2k10 11ZONA 22kCONTACTOSTAMPER2k3kPARA INFORMACIONDETALLADA VERINSTRUCCIONESZONA 106.2k2kZONA 42kZONA 3CONSOLAS REMOTASPUEDE USAR CONSOLAS6128RF, 6148 O 6164.(DEBE CONFIGURARPRIMERA CONSOLACOMO DIRECCION 16.)CONEXIONADO TIPICOPARA DOBLAR ZONAS (SOLO PUEDEUSARSE EN ZONAS 2-8)CONEXIONADO PARA ZONASDE DOBLE BALANCEO (SOLO PUEDEUSARSE EN ZONAS 2-8)VISTA-48D-SP-SOC-V0VISTA-48DDIAGRAMA DE CONEXIONESFigura 17. Diagrama de Conexiones9-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!