Error Display Reason RemedyBattery isnot beingchargedduring thedayBatterywrongpolarityPermanentsoundSolar arrayfaulty orwrong polarity(Green LEDoff)Battery isconnected withreverse polarityRemove faultyconnection /reverse polarityRemove reversepolarityGeneral Safety and Usage RecommendationsIntended UseThe charge controller is intended exclusively for use in photovoltaicsystems with 12 V or 24 V nominal voltage and in conjunction withvented or sealed (VRLA) lead acid batteries only.Safety RecommendationsBatteries store a large amount of energy. Never short circuit abattery under all circumstances. We recommend connecting a fuse(slow acting type, according to the nominal controller current)directly to the battery terminal.Batteries can produce flammable gases. Avoid making sparks, usingfire or any naked flame. Make sure that the battery room isventilated.Avoid touching or short circuiting wires or terminals. Be awarethat the voltages on specific terminals or wires can be up to double34