REMARK: Mind the recommendations of your batterymanufacturer. We strongly recommend connecting a fuse directlyto the battery to protect any short circuit at the battery wiring.The fuse must take the charge controller nominal current:<strong>CML</strong>05: 20A, <strong>CML</strong>08: 20A, <strong>CML</strong>10: 30A,<strong>CML</strong>15: 30A, <strong>CML</strong>20: 40A3Connect the wires leading to the solararray with correct polarity. To avoidany voltage on the wires, first connectthe controller, then the solar array.Mind the recommended wire size:<strong>CML</strong>05: min 2.5 mm 2<strong>CML</strong>08: min 4 mm 2<strong>CML</strong>10: min 6 mm 2<strong>CML</strong>15, <strong>CML</strong>20: min 10 mm 2REMARK: Place positive and negative wire close to each otherto minimize electromagnetic effects.REMARK: Solar panels provide voltage as soon as exposed tosun light. Mind the solar panel manufacturer's recommendationsin any case.23