12.07.2015 Views

Altivar 11

Altivar 11

Altivar 11

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Code Description Factory setting:;% Preset speedsIf LIA and LIb = 0: speed = reference on AI1If LIA = 1 and LIb = 0: speed = SP2If LIA = 0 and LIb = 1: speed = SP3If LIA = 1 and LIb = 1: speed = SP475- Assignment of input LIA if tCC = 2C: LI3if tCC = 3C: LI4-nO: function inactive- LI1 to LI4: choice of the input assigned to LIA75> Assignment of input LIb if tCC = 2C: LI4if tCC = 3C: nO-nO: function inactive- LI1 to LI4: choice of the input assigned to LIb;:%;:&;:'SP2 is only accessible if LIA is assigned, SP3 and SP4 if LIA and LIb are assigned.2nd preset speed, adjustable from 0.0 Hz to HSP (1)3rd preset speed, adjustable from 0.0 Hz to HSP (1)4th preset speed, adjustable from 0.0 Hz to HSP (1)(1) The settings can also be accessed in the 1st level adjustment parameters.4;: High speeds (version V1.2 IE u 21)If LIA and LIb = 0: HSPIf LIA = 1 and LIb = 0: HS2If LIA = 0 and LIb = 1: HS3If LIA = 1 and LIb = 1: HS475- Assignment of input LIA- nO: Function inactive- LI1 to LI4: Selection of input assigned to LIA75> Assignment of input LIb- nO: Function inactive- LI1 to LI4: Selection of input assigned to LIb4;:4;%4;&4;'HS2 can only be accessed if LIA is assigned; HS3 and HS4 can only beaccessed if LIA and Lib are assigned.1st high speed, adjustable between LSP and 200 Hz2nd high speed, adjustable between LSP and 200 Hz3rd high speed, adjustable between LSP and 200 Hz4th high speed, adjustable between LSP and 200 Hz79/ Overload threshold (version V1.2 IE u 21)90%LOC can be adjusted between 70 and 150% of the nominal drive current.I97 Time delay for the overload function (version V1.2 IE u 21) 5 stOL can be adjusted between 0 and 100 s.This function can be used to stop the motor in the event of an overload. If themotor current exceeds the overload threshold LOC, a time delay tOL isactivated. Once this time delay tOL has elapsed, if the current is still greater thanthe overload threshold LOC -10%, the drive will lock with an overload fault.Motor currentDrive stop on OLC faultLOCLOC - 10 %(hysteresis)102550nOnObFrbFrbFrbFrENGLISH< tOLtOLOverload detection is only active when the system is in steady state(speed reference reached).A value of 0 will deactivate overload detection.t27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!