Technical SpecificationsProductFX06 Field ControllerPower Requirement 24 VAC/VDC ±15% 50/60Hz SELV (Europe) - Class 2 North AmericaPower Consumption 7 VA maximumAmbient OperatingConditionsAmbient StorageConditionsPower SupplyOutputsAnalog Inputs andAccuracyat 20 °C (68 °F)Ambient (sensorerror not included)Display Range andResolutionDigital InputsAnalog InputsAnalog OutputsContinued on next page...-20 to 50 °C (-4 to +122 °F)10 to 95% RH (non condensing)-40 to 70 °C (-40 to +158 °F)10 to 95% RH (non condensing)• 24VAC/DC for panel mount MUI (from controller power supply input)• 15 VDC 20 mA power supply for active sensors• 5 VDC 15 mA power supply for ratio-metric sensors16 bit resolutionSensor Type Range AccuracyA99 -40 to 100 °C (-40 to 212 °F) ±0.5 °C (±1 °F)NTC K10 -20 to 70 °C (-4 to 158 °F) ±0.5 °C (±1 °F)PT1000-40 to 160 °C (-40 to 320 °F) ±1 °C (±1.8 °F)ExtendedNi1000 -40 to 120°C (-40 to 248 °F) ±1 °C (±1.8 °F)Active 0 - 10 V 0..10 VDC ±0.1Active0.5...4.5 VDC ±0.05 VDCRatiometric-999 to 999 or -99.9 to 99.9Voltage free contacts.Transition counter function on DI1 at 50 Hz (minimum 10 ms ON andminimum 10 ms OFF)See above for input types.Not isolated. 0 - 10 VDC ±1%, 3 mA (13 bit resolution), for actuating andcontrol devices.Pulse Width Modulation (PWM) Signal at 100Hz cycle frequency.FX06 Field Controller - Installation Guide5

Digital Outputs forSelected Models Model Channel TypeFX06P0x / P1x DO1 - DO6 SPST 3(1)A,250 VACrelayFX06P2x / P3x DO1, DO2 0.5A / 24VAC triacsRelay OutputsConnectionsDimensions(H x W x D)DO3 - DO6SPST 3(1)A,250 VACrelayRemark/ApplicationEach relay contact isindependent with itsown common terminal.3-point incrementalactuators, thermalactuators, etcOn the FX06P2xmodels, each relaycontact is independentwith its own commonterminal. On theFX06P3x model, DO4,DO5 and DO6 relaysare physicallyinterlocked, i.e. only oneoutput can be closed atone time. Application:3-speed fan motors.The DO3 relay isindependent.Dielectric test voltage on open relay contact: 1,000 VAC RMSMaximum relay switching rate at nominal load: 6 operations/minAverage relay contact life: 30,000 operations at maximum load.Molex ® connectors. Mating connectors and cables provided withcontroller or available to order. (See “Ordering Codes”).See Figure 1, 2 and 3Protection Class Front Plate (when mounted in panel): IP55Rear Enclosure:IP20Housing Material ABS + polycarbonate, self-extinguishing: UL94 5V0 flammability ratingCompliance Europe Directive• 89/336/EEC EMC EN 61000-6-2, EN 61000-6-3• 72/23/EEC, LV EN 60730Canada• UL Listed (PAZX7), CAN/CSA C22.2 No. 205, Signal Equipment• UL Recognized (XAPX8), CAN/CSA C22.2 No. 24,Temperature Indicating and Regulating Equipment• Industry Canada, ICES-003United States• UL Listed (PAZX), UL 916, Energy Management Equipment• UL Recognized (XAPX2), UL 873,Temperature Indicating and Regulating Equipment• FCC compliant to CFR 47, Part 15, Subpart B, Class A6 FX06 Field Controller - Installation Guide

Digital Outputs forSelected Models Model Channel Type<strong>FX06</strong>P0x / P1x DO1 - DO6 SPST 3(1)A,250 VACrelay<strong>FX06</strong>P2x / P3x DO1, DO2 0.5A / 24VAC triacsRelay OutputsConnectionsDimensions(H x W x D)DO3 - DO6SPST 3(1)A,250 VACrelayRemark/ApplicationEach relay contact isindependent with itsown common terminal.3-point incrementalactuators, thermalactuators, etcOn the <strong>FX06</strong>P2xmodels, each relaycontact is independentwith its own commonterminal. On the<strong>FX06</strong>P3x model, DO4,DO5 and DO6 relaysare physicallyinterlocked, i.e. only oneoutput can be closed atone time. Application:3-speed fan motors.The DO3 relay isindependent.Dielectric test voltage on open relay contact: 1,000 VAC RMSMaximum relay switching rate at nominal load: 6 operations/minAverage relay contact life: 30,000 operations at maximum load.Molex ® connectors. Mating connectors and cables provided withcontroller or available to order. (See “Ordering Codes”).See Figure 1, 2 and 3Protection Class Front Plate (when mounted in panel): IP55Rear Enclosure:IP20Housing Material ABS + polycarbonate, self-extinguishing: UL94 5V0 flammability ratingCompliance Europe Directive• 89/336/EEC EMC EN 61000-6-2, EN 61000-6-3• 72/23/EEC, LV EN 60730Canada• UL Listed (PAZX7), CAN/CSA C22.2 No. 205, Signal Equipment• UL Recognized (XAPX8), CAN/CSA C22.2 No. 24,Temperature Indicating and Regulating Equipment• Industry Canada, ICES-003United States• UL Listed (PAZX), UL 916, Energy Management Equipment• UL Recognized (XAPX2), UL 873,Temperature Indicating and Regulating Equipment• FCC compliant to CFR 47, Part 15, Subpart B, Class A6 <strong>FX06</strong> <strong>Field</strong> <strong>Controller</strong> - Installation Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!