1.4 teCHnICAl InForMAtIon<br />
English<br />
open <strong>Circuit</strong> <strong>Breaker</strong><br />
<strong>ABW</strong>16 <strong>ABW</strong>20 <strong>ABW</strong>25 <strong>ABW</strong>32 <strong>ABW</strong>40 <strong>ABW</strong>50<br />
Maximum nominal current<br />
(40°C) - In max. (A)<br />
1600 2000 2500 3200 4000 5000<br />
Nominal operation voltage - Ue<br />
(V)<br />
690<br />
Nominal insulation voltage - Ui<br />
(V)<br />
1000<br />
Inpulse voltage - Uimp (kV) 8<br />
Frequency (Hz) 50 / 60<br />
Number of poles 3<br />
Versions Fixed – Removable<br />
Protection units Electronic<br />
Short circuit 220/380/415V 65 85 100<br />
interruption<br />
capacity - Icu<br />
(kA)<br />
440V<br />
500V<br />
600V<br />
690V<br />
65<br />
65<br />
50<br />
50<br />
85<br />
85<br />
65<br />
50<br />
100<br />
100<br />
85<br />
50<br />
Short circuit 220/380/415V 65 85 100<br />
interrution<br />
capacity - Ics<br />
(kA)<br />
440V<br />
500V<br />
600V<br />
690V<br />
65<br />
65<br />
50<br />
50<br />
85<br />
85<br />
65<br />
50<br />
100<br />
100<br />
85<br />
50<br />
Supportability 1s 65 65 85<br />
to short circuit - 2s 60 60 65<br />
Icw (kA)<br />
3s 50 60 65<br />
Capacity of 220/380/415V 143 187 220<br />
establishment 440V 143 187 220<br />
of short circuit 500V 143 187 220<br />
(peak value) - 600V 105 143 187<br />
Icm (kA)<br />
690V 105 105 105<br />
Category of use B<br />
Time of<br />
Opening ≤ 40<br />
operation (ms) Closing ≤ 80<br />
Mechanical life (no. of operations) 12000 10000<br />
Electrical life (no. of operations) 3000<br />
Altitude (m) ≤ 2000 (1)<br />
Ambient Operation -5...40°C<br />
temperature<br />
(2)<br />
Storage -20...60°C<br />
Thermal dissipation at<br />
nominal current (W)<br />
52 160 250 410 960 1500<br />
Weight (kg)<br />
Removable (3) Fixed<br />
64<br />
41<br />
92<br />
60<br />
93<br />
61<br />
95<br />
63<br />
240<br />
115<br />
240<br />
115<br />
Power<br />
Removable Horizontal<br />
terminals<br />
(4) Vertical<br />
Fixed Horizontal (4) Horizontal (4)<br />
Dimensions - Removable 339 x 435 x 379 474x435x379 961x459x379<br />
LxHxD (mm)<br />
Notes:<br />
Fixed 315 x 410 x 295 450x410x295 840x410x295<br />
(1) For installation above 2000m, apply correction factors for nominal voltage and current, in accordance with the<br />
table on page 9.<br />
(2) For ambient temperature above 40°C, check maximum values of the nominal currents on the table on page 9.<br />
(3) Includes removal carriage.<br />
(4) Vertical terminals available as accessories. See page 62.<br />
<strong>ABW</strong> | 13